RF expo info

FCC ID: 2AKCY-RL460WHZ

RF Exposure Info

Download: PDF
FCCID_4450432

                                                                              FCC ID: 2AKCY-RL460WHZ
RF Exposure Evaluation
Limits
The criteria listed in the following table shall be used to evaluate the environment impact of human exposure
to radio frequency (RF) radiation as specified in 1.1307(b)
Limits for Maximum Permissible Exposure (MPE)
                        Electric field
Frequency range                            Magnetic field strength      Power density        Averaging time
                          strength                                                       2
      (MHz)                                             (A/m)             (mW/cm )              (minutes)
                           (V/m)
                              (A) Limits for Occupational/Controlled Exposures
     0.3–3.0                614                         1.63                *(100)                  6
                                                                                     2
      3.0–30               1842/f                       4.89/f             *(900/f )                6
     30–300                 61.4                        0.163                1.0                    6
    300–1500                                                                 f/300                  6
  1500–100,000                                                                5                     6
                          (B) Limits for General Population/Uncontrolled Exposure
     0.3–1.34               614                         1.63                *(100)                  30
                                                                                     2
     1.34–30                824/f                       2.19/f             *(180/f )                30
     30–300                 27.5                        0.073                0.2                    30
    300–1500                                                                f/1500                  30
  1500–100,000                                                               1.0                    30
f = frequency in MHz
                                                    2
Friis transmission formula: Pd = (Pout*G)/(4*pi*r )


Where
                               2
Pd = power density in mW/cm , Pout = output power to antenna in mW;
G = gain of antenna in linear scale, Pi = 3.1416;
R = distance between observation point and center of the radiator in cm

                                   2
Pd id the limit of MPE, 1 mW/cm . If we know the maximum gain of the antenna and the total power input to
the antenna, through the calculation, we will know the distance r where the MPE limit is reached.
Test Procedure
Software provided by client enabled the EUT to transmit and receive data at lowest, middle and highest
channel individually.


Test Result of RF Exposure Evaluation
                                        Power Density at
                     Output power to                                   2
   Frequency                                R=20cm         Limit (mW/cm )   Result
                      antenna (mW)                   2
                                           (mW/cm )
    2405MHz                6.78             0.0018              1.0         PASS

    2440MHz                6.81             0.0018              1.0         PASS

    2475MHz                6.03             0.0016              1.0         PASS

    2480MHz                1.44             0.00038             1.0         PASS


Remark: antenna gain=1.24dBi



Document Created: 2019-09-19 20:23:12