RF Exposure

FCC ID: 2AK2S-BCA

RF Exposure Info

Download: PDF
FCCID_4086451

Mtertek                                                                    Test report No. 1713667ST0—003, Ed. 2
                                                                                                      Page 1 (2)
Total Quality. Assured.



                          RF EXPOSURE ANALYSIS

EQUIPMENT

Equipment:                   Sander

Type/Model:                  AROS—B 150NV

Additional type/model:       AOS—B 130NV

Manufacturer:                Mirka Ltd.

Tested by request of:        Mirka Ltd.


Reference test report: Intertek Test report No. 1713667STO—002, Ed. 2

Operating frequencies: 2402 — 2480 MHz


REQUIREMENT

EN 50663:2017
CFR 47 §1.1310
RSS—102 issue 5 (2015)
Radiocommunications (Electromagnetic Radiation — Human Exposure)
NZS 2772.1:1999


CALCULATIONS

Highest measured conducted output power is 1.4 dBm peak.
Antenna gain is 2 dBi. EIRP is then 3.4 dBm equal to 2.2 mW




                                              Intertek Semko AB
                               Torshamnsgatan 43, Box 1103, SE—164 22 Kista, Sweden
                                                  www.intertek.se


mtertek                                                            Test report No. 1713667ST0—003, Ed. 2
                                                                                                 Page 2 (2)

LIMITS & EVALUATIONS:

         Standard                 Reference for limit                  Limit          Unit   Values    Result



     EN 50663:2017                       EN62479"                       20            mW      2.2      PASS



    CFR 47 §1.1310               KDB 447498 DO12                        3.0           N/A     0.3      PASS



    RSS—102 issue 5               RSS—102 issue 5
           (2015)                          (2015)                        4            mW      2.2      PASS


                                Radiation Protection
 Radiocommunications               Standard for
   (Electromagnetic             Maximum Exposure
  Radiation — Human                  Levels to                           20           mW      2.2      PASE
      Exposure)                Radiofrequency Fields
                                — 3 kHz to 300 GHz*


    NZS 2772.1:1999              NZS 2772.1:1999"                        20           mW      2.2      PASS


‘From Table A.1 for general public and head and trunk

21—g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances < 50 mm are determined
by: [(max. power of channel, including tune—up tolerance, mW)/(min. test separation distance, mm)] +[Vf(GHz)] <
3.0. Test separation distance is taken as 5 mm and maximum power is 2 mW at 2.4 GHz.

SSection 2.5.1, table 1, based on a separation distance of 5 mm and frequency of 2450 MHz.

4Table S$1, General public exposure

5 Section 3.7.3: In some circumstances an RF exposure evaluation may not be required. This is the case with
low—power devices whose nominal average RF radiated power does not exceed 20 mW and which do not
produce exceptionally high instantaneous fields.


Summary:

All requirements are fulfilled


Date of issue: 2018—11—16


21«xn
Issued by: Robert Hictala

Intertek Semko AB, Radio & EMC

                                                     Intertek Semko AB
                                      Torshamnsgatan 43, Box 1103, SE—164 22 Kista, Sweden
                                                        www.intertek.se
                                                                                                        Version 1.00



Document Created: 2018-11-16 16:52:14
Document Modified: 2018-11-16 16:52:14

© 2024 FCC.report