RF Exposure Report

FCC ID: 2AK26-199000

RF Exposure Info

Download: PDF
FCCID_4266962

                       Test Report No.: FM190103N045



                                       RF EXPOSURE REPORT
Applicant                        World of Watersports Limited

Address                          Unit B, 3/F Eton Building, 288 Des Voeux Road, Central, Hong Kong


Manufacturer or
                                 Top Loyal Electronics Co.,Ltd
Supplier
                                 NO.22 GuangMing Ave, Dongcheng district, DongGuan city, GuangDong Province
Address
                                 523126

Product                          WOW SOUND BUOY

Brand Name                       WORLD OF WATERSPORTS

Model                            199000

Additional Model &
                                 199010
Model Difference

Date of tests                    Jan. 03, 2019~ Jan. 30, 2019

     FCC Part 2 (Section 2.1093)
     KDB 447498 D01
     IEEE C95.1

CONCLUSION: The submitted sample was found to COMPLY with the test requirement

                    Tested by Breeze Jiang                                                              Approved by Chris Chen
              Project Engineer / EMC Department                                                        Manager / EMC Department




                                                                                                               Date: Mar. 07, 2019
This report is governed by, and incorporates by reference, CPS Conditions of Service as posted at the date of issuance of this report at
http://www.bureauveritas.com/home/about-us/our-business/cps/about-us/terms-conditions/and is intended for your exclusive use. Any copying or replication
of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This report sets forth our
findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or representative of the quality or
characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report includes all
of the tests requested by you and the results thereof based upon the information that you provided to us. Measurement uncertainty is only provided upon
request for accredited tests. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence or if
you require measurement uncertainty; provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A
failure to raise such issue within the prescribed time shall constitute you unqualified acceptance of the completeness of this report, the tests conducted and
the correctness of the report contents.


                                                        No. 34, Chenwulu Section, Guantai Rd., Houjie                Tel: +86 769 8998 2098
 Bureau Veritas Shenzhen Co., Ltd.
                                                        Town, Dongguan City,                                         Fax: +86 769 8593 1080
 Dongguan Branch
                                                        Guangdong 523942, China                                      Email: customerservice.dg@cn.bureauveritas.com
                                                                              Page 1 of 6                                                               Report Version 1


                Test Report No.: FM190103N045




                                          Table of Contents
   RELEASE CONTROL RECORD ................................................................................ 3
   1.       CERTIFICATION .............................................................................................. 4
   2.       RF EXPOSURE DEFINE ................................................................................. 5
   3.       CLASSIFICATION ........................................................................................... 5
   4.       SAR TEST EXCLUSION THRESHOLDS ........................................................ 6




                                         No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                         Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch
                                         Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                           Page 2 of 6                                                   Report Version 1


                Test Report No.: FM190103N045


                               RELEASE CONTROL RECORD

    ISSUE NO.                REASON FOR CHANGE                                                      DATE ISSUED
    FM190103N045             Original release                                                         Mar. 07, 2019




                                       No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                       Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch
                                       Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                        Page 3 of 6                                                    Report Version 1


                Test Report No.: FM190103N045



   1. CERTIFICATION


                       FCC ID:      2AK26-199000

                  PRODUCT:          WOW SOUND BUOY

             BRAND NAME:            WORLD OF WATERSPORTS

                MODEL NO.:          199000

        ADDITIONAL NO.:             199010

            TEST SAMPLE:            Engineering Sample

                APPLICANT:          World of Watersports Limited

              STANDARDS:            FCC Part 2 (Section 2.1093)

                                    KDB 447498 D01

                                    IEEE C95.1

   Remarks: Additional model 199010 is identical with the test model 199000 except the model number
   for marketing purpose.




                                     No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                     Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch
                                     Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                      Page 4 of 6                                                    Report Version 1


                Test Report No.: FM190103N045

   2. RF EXPOSURE DEFINE
   The corresponding SAR Exclusion Threshold condition, listed below:

   1) The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances
     ≤ 50 mm are determined by:
     [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance,
     mm)] ·[√f(GHz)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR,16 where
          f(GHz) is the RF channel transmit frequency in GHz
        Power and distance are rounded to the nearest mW and mm before calculation
          The result is rounded to one decimal place for comparison
     The test exclusions are applicable only when the minimum test separation distance is ≤ 50 mm and
     for transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation
     distance is < 5 mm, a distance of 5 mm is applied to determine SAR test exclusion.
   2) At 100 MHz to 6 GHz and for test separation distances > 50 mm, the SAR test exclusion threshold
     is determined according to the following:
     a) [Threshold at 50 mm in step 1) + (test separation distance - 50 mm)·( f(MHz)/150)] mW, at
       100MHz to 1500 MHz
     b) [Threshold at 50 mm in step 1) + (test separation distance - 50 mm)·10] mW at > 1500 MHz and ≤
       6 GHz
   3) At frequencies below 100 MHz, the following may be considered for SAR test exclusion.
     a) The threshold at the corresponding test separation distance at 100 MHz in step 2) is multiplied by
       [1 + log(100/f(MHz))] for test separation distances > 50 mm and < 200 mm.
     b) The threshold determined by the equation in a) for 50 mm and 100 MHz is multiplied by ½ for test
       separation distances ≤ 50 mm.
     c) SAR measurement procedures are not established below 100 MHz. When SAR test exclusion
       cannot be applied, a KDB inquiry is required to determine SAR evaluation requirements for any
       test results to be acceptable.


   3. CLASSIFICATION
   The antenna of this product, under normal use condition, is at less than 20cm away
   from the body of the user. So, this device is classified as Portable Device.




                                     No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                     Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch
                                     Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                      Page 5 of 6                                                    Report Version 1


                Test Report No.: FM190103N045

   4. SAR TEST EXCLUSION THRESHOLDS

   The tuned conducted Average Power (declared by client)

                                            Target                                   Lower                   Upper
                        Frequency                             Tolerance
      Mode                                  Power                                  Tolerance               Tolerance
                          (MHz)                                 (dBm)
                                            (dBm)                                    (dBm)                   (dBm)
      GFSK              2402-2480              -1                 +-2                   -3                       1
     8DPSK              2402-2480              -1                 +-2                   -3                       1


   The measured conducted Average Power

                                                Frequency                               Averaged Power
                Mode
                                                  (MHz)                                      (dBm)

               GFSK                                 2402                                        0.98
               8DPSK                                2402                                        -0.77



   SAR Test Exclusion Thresholds


                          Maximum
                       source-based          Minimum                                           Limit for
    Frequency          time averaged        separation         Result of       Limit for         10-g
                                                                                                                 Verdict
      (MHz)              conducted           distance           Eq. 1          1-g SAR         extremity
                        output power           (mm)                                              SAR
                           (dBm)
                                                                                                                  Exempt
     2402-2480                 1                    5             0.39            3.0               7.5            from
                                                                                                                   SAR

   Conclusion

   Therefore this device complies with FCC’s RF radiation exposure limits for general population without
   SAR evaluation.




                                       No. 34, Chenwulu Section, Guantai Rd., Houjie    Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                       Town, Dongguan City,                             Fax: +86 769 8593 1080
Dongguan Branch
                                       Guangdong 523942, China                          Email: customerservice.dg@cn.bureauveritas.com
                                                        Page 6 of 6                                                     Report Version 1



Document Created: 2019-04-10 11:41:24
Document Modified: 2019-04-10 11:41:24

© 2024 FCC.report