SAR report part 2

FCC ID: 2AJZP-D450B

RF Exposure Info

Download: PDF
FCCID_4041833

                                Appendix A:SAR Test Data Plots


Test Laboratory: Huatongwei International Inspection Co., Ltd.,SAR Lab        Date: 9/18/2018

GSM 850-Head

Communication System: UID 0, Generic GPRS(TDMA, GMSK, TN 0-1-2) (0); Frequency: 836.6
MHz;Duty Cycle: 1:2.66993
Medium parameters used (interpolated): f = 836.6 MHz; σ = 0.933 S/m; εr = 42.599; ρ = 1000 kg/m3
Phantom section: Left Section
Ambient Temperature:22.7℃;Liquid Temperature:22.3℃;

DASY Configuration:

   l   Probe: EX3DV4 - SN7494; ConvF(10.73, 10.73, 10.73) @ 836.6 MHz; Calibrated: 2/26/2018
   l   Sensor-Surface: 1.4mm (Mechanical Surface Detection)
   l   Electronics: DAE4 Sn1549; Calibrated: 4/25/2018
   l   Phantom: Twin-SAM V8.0 ; Type: QD 000 P41 AA; Serial: 1974
   l   DASY52 52.10.1(1476); SEMCAD X 14.6.11(7439)


Left Touch Cheek/CH 190/Area Scan (61x121x1): Interpolated grid: dx=1.500 mm,
dy=1.500 mm
Maximum value of SAR (interpolated) = 0.196 W/kg

Left Touch Cheek/CH 190/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm,
dy=8mm, dz=5mm
Reference Value = 4.485 V/m; Power Drift = -0.11 dB
Peak SAR (extrapolated) = 0.208 W/kg
SAR(1 g) = 0.157 W/kg; SAR(10 g) = 0.117 W/kg
Maximum value of SAR (measured) = 0.189 W/kg




              0 dB = 0.189 W/kg = -7.24 dBW/kg




                                                                                             Plot No.1


                                Appendix A:SAR Test Data Plots


Test Laboratory: Huatongwei International Inspection Co., Ltd.,SAR Lab        Date: 9/19/2018

GSM 850-Body

Communication System: UID 0, Generic GPRS(TDMA, GMSK, TN 0-1-2) (0); Frequency: 836.6
MHz;Duty Cycle: 1:2.66993
Medium parameters used (interpolated): f = 836.6 MHz; σ = 0.967 S/m; εr = 55.399; ρ = 1000 kg/m3
Phantom section: Flat Section
Ambient Temperature:22.8℃;Liquid Temperature:22.4℃;

DASY Configuration:

   l   Probe: EX3DV4 - SN7494; ConvF(10.5, 10.5, 10.5) @ 836.6 MHz; Calibrated: 2/26/2018
   l   Sensor-Surface: 1.4mm (Mechanical Surface Detection)
   l   Electronics: DAE4 Sn1549; Calibrated: 4/25/2018
   l   Phantom: ELI V8.0 ; Type: QD OVA 004 AA ; Serial: 2078
   l   DASY52 52.10.1(1476); SEMCAD X 14.6.11(7439)


Rear/CH 190/Area Scan (61x121x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm
Maximum value of SAR (interpolated) = 0.220 W/kg

Rear/CH 190/Zoom Scan (6x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value = 14.99 V/m; Power Drift = 0.12 dB
Peak SAR (extrapolated) = 0.253 W/kg
SAR(1 g) = 0.168 W/kg; SAR(10 g) = 0.128 W/kg
Maximum value of SAR (measured) = 0.217 W/kg




              0 dB = 0.217 W/kg = -6.64 dBW/kg




                                                                                             Plot No.2


                                Appendix A:SAR Test Data Plots


Test Laboratory: Huatongwei International Inspection Co., Ltd.,SAR Lab      Date: 9/20/2018

GSM 1900-Head

Communication System: UID 0, Generic GPRS(TDMA, GMSK, TN 0-1-2) (0); Frequency: 1880
MHz;Duty Cycle: 1:2.66993
Medium parameters used: f = 1880 MHz; σ = 1.455 S/m; εr = 41.738; ρ = 1000 kg/m3
Phantom section: Left Section
Ambient Temperature:22.6℃;Liquid Temperature:22.2℃;

DASY Configuration:

   l   Probe: EX3DV4 - SN7494; ConvF(8.83, 8.83, 8.83) @ 1880 MHz; Calibrated: 2/26/2018
   l   Sensor-Surface: 1.4mm (Mechanical Surface Detection)
   l   Electronics: DAE4 Sn1549; Calibrated: 4/25/2018
   l   Phantom: Twin-SAM V8.0 ; Type: QD 000 P41 AA; Serial: 1974
   l   DASY52 52.10.1(1476); SEMCAD X 14.6.11(7439)


Left Touch Cheek/CH 661/Area Scan (61x121x1): Interpolated grid: dx=1.500 mm,
dy=1.500 mm
Maximum value of SAR (interpolated) = 0.124 W/kg

Left Touch Cheek/CH 661/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm,
dy=8mm, dz=5mm
Reference Value = 2.440 V/m; Power Drift = -0.18 dB
Peak SAR (extrapolated) = 0.129 W/kg
SAR(1 g) = 0.082 W/kg; SAR(10 g) = 0.053 W/kg
Maximum value of SAR (measured) = 0.112 W/kg




              0 dB = 0.112 W/kg = -9.51 dBW/kg




                                                                                           Plot No.3


                                Appendix A:SAR Test Data Plots


Test Laboratory: Huatongwei International Inspection Co., Ltd.,SAR Lab      Date: 9/21/2018

GSM 1900-Body

Communication System: UID 0, Generic GPRS(TDMA, GMSK, TN 0-1-2) (0); Frequency: 1880
MHz;Duty Cycle: 1:2.66993
Medium parameters used: f = 1880 MHz; σ = 1.539 S/m; εr = 53.741; ρ = 1000 kg/m3
Phantom section: Flat Section
Ambient Temperature:22.7℃;Liquid Temperature:22.4℃;

DASY Configuration:

   l   Probe: EX3DV4 - SN7494; ConvF(8.42, 8.42, 8.42) @ 1880 MHz; Calibrated: 2/26/2018
   l   Sensor-Surface: 1.4mm (Mechanical Surface Detection)
   l   Electronics: DAE4 Sn1549; Calibrated: 4/25/2018
   l   Phantom: ELI V8.0 ; Type: QD OVA 004 AA ; Serial: 2078
   l   DASY52 52.10.1(1476); SEMCAD X 14.6.11(7439)


Rear/CH 661/Area Scan (61x121x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm
Maximum value of SAR (interpolated) = 0.332 W/kg

Rear/CH 661/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value = 7.711 V/m; Power Drift = -0.19 dB
Peak SAR (extrapolated) = 0.426 W/kg
SAR(1 g) = 0.217 W/kg; SAR(10 g) = 0.117 W/kg
Maximum value of SAR (measured) = 0.313 W/kg




              0 dB = 0.313 W/kg = -5.04 dBW/kg




                                                                                           Plot No.4


                                Appendix A:SAR Test Data Plots


Test Laboratory: Huatongwei International Inspection Co., Ltd.,SAR Lab      Date: 9/20/2018

WCDMA Band II-Head

Communication System: UID 0, Generic UMTS (0); Frequency: 1880 MHz;Duty Cycle: 1:1
Medium parameters used: f = 1880 MHz; σ = 1.455 S/m; εr = 41.738; ρ = 1000 kg/m3
Phantom section: Left Section
Ambient Temperature:22.7℃;Liquid Temperature:22.4℃;

DASY Configuration:

   l   Probe: EX3DV4 - SN7494; ConvF(8.83, 8.83, 8.83) @ 1880 MHz; Calibrated: 2/26/2018
   l   Sensor-Surface: 1.4mm (Mechanical Surface Detection)
   l   Electronics: DAE4 Sn1549; Calibrated: 4/25/2018
   l   Phantom: Twin-SAM V8.0 ; Type: QD 000 P41 AA; Serial: 1974
   l   DASY52 52.10.1(1476); SEMCAD X 14.6.11(7439)


Left Touch Cheek/CH 9400/Area Scan (61x121x1): Interpolated grid: dx=1.500 mm,
dy=1.500 mm
Maximum value of SAR (interpolated) = 0.288 W/kg

Left Touch Cheek/CH 9400/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm,
dy=8mm, dz=5mm
Reference Value = 3.732 V/m; Power Drift = -0.18 dB
Peak SAR (extrapolated) = 0.311 W/kg
SAR(1 g) = 0.197 W/kg; SAR(10 g) = 0.124 W/kg
Maximum value of SAR (measured) = 0.266 W/kg




              0 dB = 0.266 W/kg = -5.75 dBW/kg




                                                                                           Plot No.5


                                Appendix A:SAR Test Data Plots


Test Laboratory: Huatongwei International Inspection Co., Ltd.,SAR Lab      Date: 9/21/2018

WCDMA Band II-Body

Communication System: UID 0, Generic UMTS (0); Frequency: 1880 MHz;Duty Cycle: 1:1
Medium parameters used: f = 1880 MHz; σ = 1.539 S/m; εr = 53.741; ρ = 1000 kg/m3
Phantom section: Flat Section
Ambient Temperature:22.7℃;Liquid Temperature:22.4℃;

DASY Configuration:

   l   Probe: EX3DV4 - SN7494; ConvF(8.42, 8.42, 8.42) @ 1880 MHz; Calibrated: 2/26/2018
   l   Sensor-Surface: 1.4mm (Mechanical Surface Detection)
   l   Electronics: DAE4 Sn1549; Calibrated: 4/25/2018
   l   Phantom: ELI V8.0 ; Type: QD OVA 004 AA ; Serial: 2078
   l   DASY52 52.10.1(1476); SEMCAD X 14.6.11(7439)


Rear/CH 9400/Area Scan (61x121x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm
Maximum value of SAR (interpolated) = 1.00 W/kg

Rear/CH 9400/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value = 11.13 V/m; Power Drift = 0.20 dB
Peak SAR (extrapolated) = 1.30 W/kg
SAR(1 g) = 0.635 W/kg; SAR(10 g) = 0.332 W/kg
Maximum value of SAR (measured) = 0.985 W/kg




              0 dB = 0.985 W/kg = -0.07 dBW/kg




                                                                                           Plot No.6


                                Appendix A:SAR Test Data Plots


Test Laboratory: Huatongwei International Inspection Co., Ltd.,SAR Lab        Date: 9/25/2018

WCDMA Band IV-Head

Communication System: UID 0, Generic UMTS (0); Frequency: 1732.6 MHz;Duty Cycle: 1:1
Medium parameters used (interpolated): f = 1732.6 MHz; σ = 1.364 S/m; εr = 41.972; ρ = 1000 kg/m3

Phantom section: Left Section
Ambient Temperature:22.7℃;Liquid Temperature:22.3℃;

DASY Configuration:

   l   Probe: EX3DV4 - SN7494; ConvF(9.23, 9.23, 9.23) @ 1732.6 MHz; Calibrated: 2/26/2018
   l   Sensor-Surface: 1.4mm (Mechanical Surface Detection)
   l   Electronics: DAE4 Sn1549; Calibrated: 4/25/2018
   l   Phantom: Twin-SAM V8.0 ; Type: QD 000 P41 AA; Serial: 1974
   l   DASY52 52.10.1(1476); SEMCAD X 14.6.11(7439)


Left Touch Cheek/CH 1413/Area Scan (61x121x1): Interpolated grid: dx=1.500 mm,
dy=1.500 mm
Maximum value of SAR (interpolated) = 0.0392 W/kg

Left Touch Cheek/CH 1413/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm,
dy=8mm, dz=5mm
Reference Value = 2.228 V/m; Power Drift = -0.12 dB
Peak SAR (extrapolated) = 0.0400 W/kg
SAR(1 g) = 0.026 W/kg; SAR(10 g) = 0.018 W/kg
Maximum value of SAR (measured) = 0.0340 W/kg




              0 dB = 0.0340 W/kg = -14.69 dBW/kg




                                                                                             Plot No.7


                                Appendix A:SAR Test Data Plots


Test Laboratory: Huatongwei International Inspection Co., Ltd.,SAR Lab        Date: 9/26/2018

WCDMA Band IV-Body

Communication System: UID 0, Generic UMTS (0); Frequency: 1732.6 MHz;Duty Cycle: 1:1
Medium parameters used (interpolated): f = 1732.6 MHz; σ = 1.43 S/m; εr = 53.891; ρ = 1000 kg/m3
Phantom section: Flat Section
Ambient Temperature:22.7℃;Liquid Temperature:22.4℃;

DASY Configuration:

   l   Probe: EX3DV4 - SN7494; ConvF(8.77, 8.77, 8.77) @ 1732.6 MHz; Calibrated: 2/26/2018
   l   Sensor-Surface: 1.4mm (Mechanical Surface Detection)
   l   Electronics: DAE4 Sn1549; Calibrated: 4/25/2018
   l   Phantom: ELI V8.0 ; Type: QD OVA 004 AA ; Serial: 2078
   l   DASY52 52.10.1(1476); SEMCAD X 14.6.11(7439)


Rear/CH 1413/Area Scan (61x131x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm
Maximum value of SAR (interpolated) = 1.04 W/kg

Rear/CH 1413/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value = 4.618 V/m; Power Drift = 0.07 dB
Peak SAR (extrapolated) = 1.19 W/kg
SAR(1 g) = 0.632 W/kg; SAR(10 g) = 0.329 W/kg
Maximum value of SAR (measured) = 0.956 W/kg




              0 dB = 0.956 W/kg = -0.20 dBW/kg




                                                                                             Plot No.8


                                Appendix A:SAR Test Data Plots


Test Laboratory: Huatongwei International Inspection Co., Ltd.,SAR Lab        Date: 9/18/2018

WCDMA Band V-Head

Communication System: UID 0, Generic UMTS (0); Frequency: 836.6 MHz;Duty Cycle: 1:1
Medium parameters used (interpolated): f = 836.6 MHz; σ = 0.933 S/m; εr = 42.599; ρ = 1000 kg/m3
Phantom section: Left Section
Ambient Temperature:22.8℃;Liquid Temperature:22.4℃;

DASY Configuration:

   l   Probe: EX3DV4 - SN7494; ConvF(10.73, 10.73, 10.73) @ 836.6 MHz; Calibrated: 2/26/2018
   l   Sensor-Surface: 1.4mm (Mechanical Surface Detection)
   l   Electronics: DAE4 Sn1549; Calibrated: 4/25/2018
   l   Phantom: Twin-SAM V8.0 ; Type: QD 000 P41 AA; Serial: 1974
   l   DASY52 52.10.1(1476); SEMCAD X 14.6.11(7439)


Left Touch Cheek/CH 4183/Area Scan (61x121x1): Interpolated grid: dx=1.500 mm,
dy=1.500 mm
Maximum value of SAR (interpolated) = 0.176 W/kg

Left Touch Cheek/CH 4183/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm,
dy=8mm, dz=5mm
Reference Value = 4.415 V/m; Power Drift = 0.20 dB
Peak SAR (extrapolated) = 0.193 W/kg
SAR(1 g) = 0.143 W/kg; SAR(10 g) = 0.106 W/kg
Maximum value of SAR (measured) = 0.173 W/kg




              0 dB = 0.173 W/kg = -7.62 dBW/kg




                                                                                             Plot No.9


                                Appendix A:SAR Test Data Plots


Test Laboratory: Huatongwei International Inspection Co., Ltd.,SAR Lab        Date: 9/19/2018

WCDMA Band V-Body

Communication System: UID 0, Generic UMTS (0); Frequency: 836.6 MHz;Duty Cycle: 1:1
Medium parameters used (interpolated): f = 836.6 MHz; σ = 0.967 S/m; εr = 55.399; ρ = 1000 kg/m3
Phantom section: Flat Section
Ambient Temperature:22.4℃;Liquid Temperature:22.2℃;

DASY Configuration:

   l   Probe: EX3DV4 - SN7494; ConvF(10.5, 10.5, 10.5) @ 836.6 MHz; Calibrated: 2/26/2018
   l   Sensor-Surface: 1.4mm (Mechanical Surface Detection)
   l   Electronics: DAE4 Sn1549; Calibrated: 4/25/2018
   l   Phantom: ELI V8.0 ; Type: QD OVA 004 AA ; Serial: 2078
   l   DASY52 52.10.1(1476); SEMCAD X 14.6.11(7439)


Rear/CH 4183/Area Scan (61x121x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm
Maximum value of SAR (interpolated) = 0.588 W/kg

Rear/CH 4183/Zoom Scan (6x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value = 24.93 V/m; Power Drift = 0.08 dB
Peak SAR (extrapolated) = 0.683 W/kg
SAR(1 g) = 0.461 W/kg; SAR(10 g) = 0.344 W/kg
Maximum value of SAR (measured) = 0.590 W/kg




              0 dB = 0.590 W/kg = -2.29 dBW/kg




                                                                                             Plot No.10


                                Appendix A:SAR Test Data Plots


Test Laboratory: Huatongwei International Inspection Co., Ltd.,SAR Lab      Date: 9/20/2018

LTE Band 2-Head

Communication System: UID 0, Generic LTE-FDD (0); Frequency: 1880 MHz;Duty Cycle: 1:1
Medium parameters used: f = 1880 MHz; σ = 1.455 S/m; εr = 41.738; ρ = 1000 kg/m3
Phantom section: Left Section
Ambient Temperature:22.7℃;Liquid Temperature:22.4℃;

DASY Configuration:

   l   Probe: EX3DV4 - SN7494; ConvF(8.83, 8.83, 8.83) @ 1880 MHz; Calibrated: 2/26/2018
   l   Sensor-Surface: 1.4mm (Mechanical Surface Detection)
   l   Electronics: DAE4 Sn1549; Calibrated: 4/25/2018
   l   Phantom: Twin-SAM V8.0 ; Type: QD 000 P41 AA; Serial: 1974
   l   DASY52 52.10.1(1476); SEMCAD X 14.6.11(7439)


Left Touch Cheek/CH 18900/Area Scan (61x121x1): Interpolated grid: dx=1.500 mm,
dy=1.500 mm
Maximum value of SAR (interpolated) = 0.350 W/kg

Left Touch Cheek/CH 18900/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm,
dy=8mm, dz=5mm
Reference Value = 3.938 V/m; Power Drift = -0.13 dB
Peak SAR (extrapolated) = 0.411 W/kg
SAR(1 g) = 0.262 W/kg; SAR(10 g) = 0.164 W/kg
Maximum value of SAR (measured) = 0.355 W/kg




              0 dB = 0.355 W/kg = -4.50 dBW/kg




                                                                                           Plot No.11


                                Appendix A:SAR Test Data Plots


Test Laboratory: Huatongwei International Inspection Co., Ltd.,SAR Lab      Date: 9/21/2018

LTE Band 2-Body

Communication System: UID 0, Generic LTE-FDD (0); Frequency: 1880 MHz;Duty Cycle: 1:1
Medium parameters used: f = 1880 MHz; σ = 1.539 S/m; εr = 53.741; ρ = 1000 kg/m3
Phantom section: Flat Section
Ambient Temperature:22.7℃;Liquid Temperature:22.4℃;

DASY Configuration:

   l   Probe: EX3DV4 - SN7494; ConvF(8.42, 8.42, 8.42) @ 1880 MHz; Calibrated: 2/26/2018
   l   Sensor-Surface: 1.4mm (Mechanical Surface Detection)
   l   Electronics: DAE4 Sn1549; Calibrated: 4/25/2018
   l   Phantom: ELI V8.0 ; Type: QD OVA 004 AA ; Serial: 2078
   l   DASY52 52.10.1(1476); SEMCAD X 14.6.11(7439)


Rear/CH 18900/Area Scan (61x121x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm
Maximum value of SAR (interpolated) = 1.19 W/kg

Rear/CH 18900/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm,
dz=5mm
Reference Value = 14.85 V/m; Power Drift = -0.16 dB
Peak SAR (extrapolated) = 1.39 W/kg
SAR(1 g) = 0.684 W/kg; SAR(10 g) = 0.361 W/kg
Maximum value of SAR (measured) = 1.11 W/kg




              0 dB = 1.11 W/kg = 0.45 dBW/kg




                                                                                           Plot No.12


                                Appendix A:SAR Test Data Plots


Test Laboratory: Huatongwei International Inspection Co., Ltd.,SAR Lab        Date: 9/25/2018

LTE Band 4-Head

Communication System: UID 0, Generic LTE-FDD (0); Frequency: 1732.5 MHz;Duty Cycle: 1:1
Medium parameters used (interpolated): f = 1732.5 MHz; σ = 1.363 S/m; εr = 41.972; ρ = 1000 kg/m3

Phantom section: Left Section
Ambient Temperature:22.7℃;Liquid Temperature:22.4℃;

DASY Configuration:

   l   Probe: EX3DV4 - SN7494; ConvF(9.23, 9.23, 9.23) @ 1732.5 MHz; Calibrated: 2/26/2018
   l   Sensor-Surface: 1.4mm (Mechanical Surface Detection)
   l   Electronics: DAE4 Sn1549; Calibrated: 4/25/2018
   l   Phantom: Twin-SAM V8.0 ; Type: QD 000 P41 AA; Serial: 1974
   l   DASY52 52.10.1(1476); SEMCAD X 14.6.11(7439)


Left Touch Cheek/CH 20175/Area Scan (61x121x1): Interpolated grid: dx=1.500 mm,
dy=1.500 mm
Maximum value of SAR (interpolated) = 0.0492 W/kg

Left Touch Cheek/CH 20175/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm,
dy=8mm, dz=5mm
Reference Value = 2.883 V/m; Power Drift = -0.12 dB
Peak SAR (extrapolated) = 0.0510 W/kg
SAR(1 g) = 0.033 W/kg; SAR(10 g) = 0.023 W/kg
Maximum value of SAR (measured) = 0.0445 W/kg




              0 dB = 0.0445 W/kg = -13.52 dBW/kg




                                                                                             Plot No.13


                                Appendix A:SAR Test Data Plots


Test Laboratory: Huatongwei International Inspection Co., Ltd.,SAR Lab        Date: 9/26/2018

LTE Band 4-Body

Communication System: UID 0, Generic LTE-FDD (0); Frequency: 1732.5 MHz;Duty Cycle: 1:1
Medium parameters used (interpolated): f = 1732.5 MHz; σ = 1.43 S/m; εr = 53.892; ρ = 1000 kg/m3
Phantom section: Flat Section
Ambient Temperature:22.7℃;Liquid Temperature:22.4℃;

DASY Configuration:

   l   Probe: EX3DV4 - SN7494; ConvF(8.77, 8.77, 8.77) @ 1732.5 MHz; Calibrated: 2/26/2018
   l   Sensor-Surface: 1.4mm (Mechanical Surface Detection)
   l   Electronics: DAE4 Sn1549; Calibrated: 4/25/2018
   l   Phantom: ELI V8.0 ; Type: QD OVA 004 AA ; Serial: 2078
   l   DASY52 52.10.1(1476); SEMCAD X 14.6.11(7439)


Rear/CH 20175/Area Scan (61x121x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm
Maximum value of SAR (interpolated) = 1.75 W/kg

Rear/CH 20175/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm,
dz=5mm
Reference Value = 6.442 V/m; Power Drift = 0.18 dB
Peak SAR (extrapolated) = 2.06 W/kg
SAR(1 g) = 1.02 W/kg; SAR(10 g) = 0.569 W/kg
Maximum value of SAR (measured) = 1.67 W/kg




              0 dB = 1.67 W/kg = 2.23 dBW/kg




                                                                                             Plot No.14


                                Appendix A:SAR Test Data Plots


Test Laboratory: Huatongwei International Inspection Co., Ltd.,SAR Lab        Date: 9/18/2018

LTE Band 5-Head

Communication System: UID 0, Generic LTE-FDD (0); Frequency: 836.5 MHz;Duty Cycle: 1:1
Medium parameters used (interpolated): f = 836.5 MHz; σ = 0.933 S/m; εr = 43.899; ρ = 1000 kg/m3
Phantom section: Left Section
Ambient Temperature:22.7℃;Liquid Temperature:22.3℃;

DASY Configuration:

   l   Probe: EX3DV4 - SN7494; ConvF(10.73, 10.73, 10.73) @ 836.5 MHz; Calibrated: 2/26/2018
   l   Sensor-Surface: 1.4mm (Mechanical Surface Detection)
   l   Electronics: DAE4 Sn1549; Calibrated: 4/25/2018
   l   Phantom: Twin-SAM V8.0 ; Type: QD 000 P41 AA; Serial: 1974
   l   DASY52 52.10.1(1476); SEMCAD X 14.6.11(7439)


Left Touch Cheek/CH 20525/Area Scan (61x121x1): Interpolated grid: dx=1.500 mm,
dy=1.500 mm
Maximum value of SAR (interpolated) = 0.170 W/kg

Left Touch Cheek/CH 20525/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm,
dy=8mm, dz=5mm
Reference Value = 4.437 V/m; Power Drift = -0.02 dB
Peak SAR (extrapolated) = 0.194 W/kg
SAR(1 g) = 0.143 W/kg; SAR(10 g) = 0.106 W/kg
Maximum value of SAR (measured) = 0.175 W/kg




              0 dB = 0.175 W/kg = -7.57 dBW/kg




                                                                                             Plot No.15