                                Maximum Permissible Exposure Calculations

                                For Kinestral Technologies Inc M/N: GW100

                                          802.15.4 Zigbee Transceiver


EUT Device Category = General Population/Uncontrolled Exposure

EUT consists of one ISM band radio transmitting operating over a range of:
2405 MHz to 2475 MHz



MPE Summary:

According subpart 1.1307 (b)(1) and 2.1091 systems operating under the provisions of this section shall be
operated in a manner that ensures the public is not exposed to RF energy level in excess of the communication
guidelines.

Limits for General Population/Uncontrolled Exposure

    Limits for General Population/Uncontrolled Exposure
    Frequency Range Electric       Field Magnetic       Field Power Density Averaging                               Time
    (MHz)           Strength (V/m)       Strength (A/m)       (mW/cm2)      (Minutes)
    0.3-1.34             614                    1.63                  *(100)                   30
    1.34-30                       824/f         2.19/f                *(180/f2)                30
    30-300               27.5                   0.073                 0.2                      30
    300-1500             /                      /                     f/1500                   30
    1500-100,000         /                      /                     1.0                      30
                      f = frequency in MHz;     * = Plane-wave equivalent power density




Gateway MPE                                                                                                        Page 1 of 2
                                               PROPRIETARY


                                                                    313 West 12800 South, Suite 311, Draper, UT 84020 • (801) 260-4040


Calculated Formulary:

Predication of MPE limit at a given distance




S = power density (in appropriate units, e.g. mW/cm2)
R = distance to the center of radiation of the antenna (appropriate units, e.g., cm)
PG = EIRP

MPE and Limit are calculated as follows:

                Output      Antenna
                                     EIRP            EIRP       Power Density                Limit
   f (MHz)      Power        Gain                                                                                       ∆
                                    (dBm)           (mW)         (mW/cm^2)                 (mW/cm^2)
                (dBm)        (dBi)
    2405         15.41        2.0   17.41           55.08            0.011                      1000                999.98
    2440         14.65        2.0   16.65           46.24            0.009                      1000                999.99
    2475         14.67        2.0   16.67           46.45            0.009                      1000                999.99


Result: The device meets FCC MPE limit at 20 cm for General Population/Uncontrolled Exposure as specified in