Report_15.247-C2PC_Rev 1

FCC ID: 2AJVQ-ZD7638GU

Test Report

Download: PDF
FCCID_4466542

Qingdao Intelligent&Precise Electronics Co., Ltd

C2PC RF TEST REPORT
Report Type:
FCC Part 15.247 & ISED RSS-247 RF report


Model:
ZDGFMT7638GU-F


REPORT NUMBER:
190900239SHA-001


ISSUE DATE:
September 25, 2019



DOCUMENT CONTROL NUMBER:
TTRF15.247-01_V1 © 2018 Intertek


                                                                                                                 Intertek Testing Services Shanghai
                                                                                                       Building No.86, 1198 Qinzhou Road (North)
                                                                                                                      Caohejing Development Zone
                                                                                                                           Shanghai 200233, China

                                                                                                                      Telephone: 86 21 6127 8200
TEST REPORT                                                                                                                   www.intertek.com

                                                                                                          Report no.: 190900239SHA-001


Applicant:                               Qingdao Intelligent&Precise Electronics Co., Ltd
                                         No.218, Qianwangang Road, Qingdao Economic&Technological
                                         Development Zone, Shandong, China.


Manufacturer:                            Qingdao Intelligent&Precise Electronics Co., Ltd
                                         No.218, Qianwangang Road, Qingdao Economic&Technological
                                         Development Zone, Shandong, China.


Factory:                                 Qingdao Intelligent&Precise Electronics Co., Ltd
                                         No.218, Qianwangang Road, Qingdao Economic&Technological
                                         Development Zone, Shandong, China.


FCC ID:                                  2AJVQ-ZD7638GU
IC:                                      22470-ZD7638GU


SUMMARY:
 The equipment complies with the requirements according to the following standard(s) or Specification:
 47CFR Part 15 (2018): Radio Frequency Devices (Subpart C)

 ANSI C63.10 (2013): American National Standard of Procedures for Compliance Testing of Unlicensed
 Wireless Devices

 RSS-247 Issue 2 (February 2017): Digital Transmission Systems (DTSs), Frequency Hopping Systems
 (FHSs) and Licence-Exempt Local Area Network (LE-LAN) Devices

 RSS-Gen Issue 5 (March 2019): General Requirements for Compliance of Radio Apparatus




PREPARED BY:                                                                REVIEWED BY:




Project Engineer                                                            Reviewer
Nemo Li                                                                     Daniel Zhao



This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's
responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the
Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to
permit copying or distribution of this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or
advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this
report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been
under an Intertek certification program.

TTRF15.247-01_V1 © 2017 Intertek                                   Page 2 of 21


                                                                                                                              Report No.: 190900239SHA-001



TEST REPORT

                                                                            Content
REVISION HISTORY................................................................................................................................................ 4
MEASUREMENT RESULT SUMMARY...................................................................................................................... 5
1       GENERAL INFORMATION ............................................................................................................................. 6
    1.1     DESCRIPTION OF EQUIPMENT UNDER TEST (EUT) ..................................................................................................... 6
    1.2     TECHNICAL SPECIFICATION .................................................................................................................................... 7
    1.3     DESCRIPTION OF TEST FACILITY .............................................................................................................................. 8
2       TEST SPECIFICATIONS................................................................................................................................... 9
    2.1     STANDARDS OR SPECIFICATION ............................................................................................................................... 9
    2.2     MODE OF OPERATION DURING THE TEST................................................................................................................... 9
    2.3     TEST SOFTWARE LIST ............................................................................................................................................ 9
    2.4     TEST PERIPHERALS LIST ......................................................................................................................................... 9
    2.5     TEST ENVIRONMENT CONDITION:............................................................................................................................ 9
    2.6     INSTRUMENT LIST .............................................................................................................................................. 10
    2.7     MEASUREMENT UNCERTAINTY ............................................................................................................................. 12
3       RADIATED EMISSIONS ............................................................................................................................... 13
    3.1     LIMIT .............................................................................................................................................................. 13
    3.2     MEASUREMENT PROCEDURE ............................................................................................................................... 13
    3.3     TEST CONFIGURATION ........................................................................................................................................ 15
    3.4     TEST RESULTS OF RADIATED EMISSIONS ................................................................................................................. 17
4       POWER LINE CONDUCTED EMISSION ......................................................................................................... 18
    4.1     LIMIT .............................................................................................................................................................. 18
    4.2     TEST CONFIGURATION ........................................................................................................................................ 18
    4.3     MEASUREMENT PROCEDURE ............................................................................................................................... 19
    4.4     TEST RESULTS OF POWER LINE CONDUCTED EMISSION............................................................................................... 20




TTRF15.247-01_V1 © 2018 Intertek                                                Page 3 of 21


                                                                             Report No.: 190900239SHA-001



TEST REPORT

                                             Revision History
       Report No.                  Version               Description                    Issued Date
  190900239SHA-001                 Rev. 01         Initial issue of report           September 25, 2019




TTRF15.247-01_V1 © 2018 Intertek                Page 4 of 21


                                                                   Report No.: 190900239SHA-001



TEST REPORT

                                   Measurement result summary

                   TEST ITEM               FCC REFERANCE     IC REFERANCE           RESULT

                                                             RSS-Gen Issue 5
      Radiated Emissions below 1GHz        15.205 & 15.209                           Pass
                                                             Clause 8.9&8.10

                                                             RSS-Gen Issue 5
      Power line conducted emission             15.207                               Pass
                                                               Clause 8.8


Notes: 1: NA =Not Applicable




TTRF15.247-01_V1 © 2018 Intertek             Page 5 of 21


                                                                             Report No.: 190900239SHA-001



TEST REPORT

1 GENERAL INFORMATION
1.1 Description of Equipment Under Test (EUT)

 Product name:                     Wireless Module

 Type/Model:                       ZDGFMT7638GU-F
                                   Add a new model ZDGFMT7638GU-F. For the new model, the connector
                                   of the module is changed from ZJ.XFE(HX1.25-10P-W-K) to C&T(F05049-
                                   16P-T). By technical analysis and evaluation, only the conducted
 Description of EUT:               emission and radiated emission below 1GHz was retested.
 Rating:                           DC 5V
 EUT type:                             Table top     Floor standing
 Software Version:                 /
 Hardware Version:                 /
 Sample received date:             September 9, 2019
 Date of test:                     September 9, 2019 ~ September 20, 2019




TTRF15.247-01_V1 © 2018 Intertek                       Page 6 of 21


                                                                              Report No.: 190900239SHA-001



TEST REPORT

1.2 Technical Specification

 Frequency Range:                  2400MHz ~ 2483.5MHz
 Support Standards:                Bluetooth BR+EDR
 Operating Frequency:              2402MHz to 2480MHz
 Modulation Technique:             Frequency Hopping Spread Spectrum(FHSS)
 Type of Modulation:               GFSK, π/4-DQPSK, 8DPSK
 Channel Number:                   79 (0 - 78)
 Channel Separation:               1 MHz
 Antenna:                          PIFA Antenna, 2,3dBi


 Frequency Range:                  2400MHz to 2483.5MHz
 Support Standards:                Bluetooth Low Energy
 Operating Frequency:              2402MHz to 2480MHz
 Type of Modulation:               GFSK
 Channel Number:                   40
 Channel Separation:               2MHz
 Antenna Information:              PIFA Antenna, 2.3dBi


 Frequency Range:                  2400MHz ~ 2483.5MHz
 Support Standards:                IEEE 802.11b, IEEE 802.11g, IEEE 802.11n(HT20), IEEE 802.11n(HT40)
                                   IEEE 802.11b: DSSS (CCK, DQPSK, DBPSK)
                                   IEEE 802.11g: OFDM (64-QAM, 16-QAM, QPSK, BPSK)
                                   IEEE 802.11n(HT20): OFDM (64-QAM, 16-QAM, QPSK, BPSK)
 Type of Modulation:               IEEE 802.11n(HT40): OFDM (64-QAM, 16-QAM, QPSK, BPSK)
                                   11 Channels for 802.11b, 802.11g and 802.11n(HT20)
 Channel Number:                   7 Channels for 802.11n(HT40)
 Channel Separation:               5 MHz




TTRF15.247-01_V1 © 2018 Intertek                      Page 7 of 21


                                                                             Report No.: 190900239SHA-001



TEST REPORT

1.3 Description of Test Facility

 Name:                    Intertek Testing Services Shanghai

 Address:                 Building 86, No. 1198 Qinzhou Road(North), Shanghai 200233, P.R. China

 Telephone:               86 21 61278200

 Telefax:                 86 21 54262353


 The test facility is      CNAS Accreditation Lab
 recognized,               Registration No. CNAS L0139
 certified, or
                           FCC Accredited Lab
 accredited by these
                           Designation Number: CN1175
 organizations:
                           IC Registration Lab
                           Registration code No.: 2042B-1
                           VCCI Registration Lab
                           Registration No.: R-4243, G-845, C-4723, T-2252
                           NVLAP Accreditation Lab
                           NVLAP LAB CODE: 200849-0
                           A2LA Accreditation Lab
                           Certificate Number: 3309.02




TTRF15.247-01_V1 © 2018 Intertek                    Page 8 of 21


                                                                                  Report No.: 190900239SHA-001



TEST REPORT

2 TEST SPECIFICATIONS
2.1 Standards or specification
47CFR Part 15 (2018)
ANSI C63.10 (2013)
RSS-247 Issue 2 (February 2017)
RSS-Gen Issue 5 (March 2019)


2.2 Mode of operation during the test
While testing the transmitter mode of the EUT, the internal modulation is applied.
All the Bluetooth and WiFi mode was pre-tested and the worst mode of WiFi mode was chosen to
perform the test and the result was listed in the report.


2.3 Test software list

      Test Items                      Software                Manufacturer                   Version

Conducted emission                     ESxS-K1                      R&S                      V2.1.0

 Radiated emission                      ES-K1                       R&S                      V1.71



2.4 Test peripherals list

       Item No.                        Name                 Band and Model                 Description

            1                      Laptop computer              DELL 5480                       -



2.5 Test environment condition:

                          Test items                                Temperature               Humidity
                    Radiated Emissions                                 24C                   56% RH

             Power line conducted emission                             24C                   56% RH




TTRF15.247-01_V1 © 2018 Intertek                     Page 9 of 21


                                                                            Report No.: 190900239SHA-001



TEST REPORT

2.6 Instrument list

Conducted Emission
  Used             Equipment        Manufacturer                   Type     Internal no.      Due date
                  Test Receiver         R&S                       ESCS 30    EC 2107        2020-07-14
                      A.M.N.            R&S                       ESH2-Z5    EC 3119        2019-11-29
                      A.M.N.            R&S                       ENV 216    EC 3393        2020-07-14
                      A.M.N.            R&S                   ENV4200        EC 3558        2020-06-11
Radiated Emission
  Used             Equipment        Manufacturer                   Type     Internal no.      Due date
                  Test Receiver         R&S                       ESIB 26    EC 3045        2020-09-12
                 Bilog Antenna         TESEQ                 CBL 6112D       EC 4206        2019-12-10
                                                              AFS42-
                  Pre-amplifier         R&S               00101800-25-S-      EC5262        2020-06-11
                                                                42
                 Horn antenna           R&S                       HF 906     EC 3049        2019-11-16
                 Horn antenna           ETS                        3117     EC 4792-1       2020-02-25
                 Horn antenna          TOYO                 HAP18-26W       EC 4792-3       2020-07-09
                   Active loop
                                    Schwarzbeck              FMZB1519        EC 5345        2020-03-14
                    antenna
RF test
  Used             Equipment        Manufacturer                   Type     Internal no.      Due date
              PXA Signal Analyzer     Keysight                    N9030A     EC 5338        2020-03-04
                  Power sensor        Agilent                 U2021XA       EC 5338-1       2020-03-04
                Vector Signal
                                      Agilent                     N5182B     EC 5175        2020-03-04
                 Generator
               Universal Radio
               Communication            R&S                   CMW500          EC5944        2019-12-22
                   Tester
              MXG Analog Signal
                                      Agilent                     N5181A    EC 5338-2       2020-03-04
                 Generator
              Mobile Test System      Litepoint                    Iqxel     EC 5176        2020-01-08
                  Test Receiver         R&S                       ESCI 7     EC 4501        2020-09-12
               Climate chamber          GWS                       MT3065     EC 6021        2020-07-04
              Spectrum Analyzer       Keysight                    N9030B     EC 6078        2020-06-11
Tet Site
  Used             Equipment        Manufacturer                   Type     Internal no.      Due date
                 Shielded room        Zhongyu                        -       EC 2838        2020-01-13


TTRF15.247-01_V1 © 2018 Intertek                  Page 10 of 21


                                                                           Report No.: 190900239SHA-001



TEST REPORT
                 Shielded room       Zhongyu                       -        EC 2839        2020-01-13
                 Semi-anechoic      Albatross
                                                                   -        EC 3048        2020-07-31
                    chamber          project
                 Fully-anechoic     Albatross
                                                                   -        EC 3047        2020-07-31
                    chamber          project
Additional instrument
  Used             Equipment       Manufacturer                  Type      Internal no.      Due date
                    Therom-           ZJ1-2A                    S.M.I.F.    EC 3783
                                                                                           2020-03-10
                   Hygrograph
                    Therom-           ZJ1-2A                    S.M.I.F.    EC 3481
                                                                                           2019-12-23
                   Hygrograph
                    Therom-           ZJ1-2A                    S.M.I.F.
                                                                            EC 5198         2020-02-27
                   Hygrograph
                    Therom-           ZJ1-2A                    S.M.I.F.
                                                                            EC 3325        2020-04-07
                   Hygrograph




TTRF15.247-01_V1 © 2018 Intertek                Page 11 of 21


                                                                       Report No.: 190900239SHA-001



TEST REPORT

2.7 Measurement uncertainty

The measurement uncertainty represents an expanded uncertainty expressed at approximately
the 95% confidence level using a coverage factor of k=2.


                          Test item                            Measurement uncertainty


             Maximum peak output power                                 0.74dB


 Radiated Emissions in restricted frequency bands
                                                                       4.90dB
                  below 1GHz

 Radiated Emissions in restricted frequency bands
                                                                       5.02dB
                  above 1GHz

         Emission outside the frequency band                           2.89dB


            Power line conducted emission                              3.19dB




TTRF15.247-01_V1 © 2018 Intertek               Page 12 of 21


                                                                          Report No.: 190900239SHA-001



TEST REPORT

3 Radiated Emissions
      Test result:            Pass


3.1 Limit
The radiated emissions which fall in the restricted bands, must also comply with the radiated emission
limits specified showed as below:

                   Frequencies                   Field Strength             Measurement Distance
                      (MHz)                    (microvolts/meter)                 (meters)
                  0.009 ~ 0.490                   2400/F(kHz)                       300
                  0.490 ~ 1.705                    24000/F(kHz)                       30
                   1.705 ~ 30.0                           30                          30
                      30 ~ 88                            100                           3
                     88 ~ 216                            150                           3
                     216 ~ 960                           200                           3
                     Above 960                           500                           3



3.2 Measurement Procedure
For Radiated emission below 30MHz:

     a) The EUT was placed on the top of a rotating table 0.8 meters above the ground at a 3 meters
        chamber room. The table was rotated 360 degrees to determine the position of the highest
        radiation.
     b) The EUT was set 3 meters away from the interference-receiving antenna, which was mounted
        on the top of a variable-height antenna tower.
     c) Both X and Y axes of the antenna are set to make the measurement.
     d) For each suspected emission, the EUT was arranged to its worst case and the rotatable table was
        turned from 0 degrees to 360 degrees to find the maximum reading.
     e) The test-receiver system was set to Quasi-Peak Detect Function and Specified Bandwidth with
        Maximum Hold Mode.
NOTE:
 1. The resolution bandwidth and video bandwidth of test receiver/spectrum analyzer is 9kHz at
    frequency below 30MHz.




TTRF15.247-01_V1 © 2018 Intertek               Page 13 of 21


                                                                           Report No.: 190900239SHA-001



TEST REPORT
For Radiated emission above 30MHz:

     a) The EUT was placed on the top of a rotating table 0.8 meters (for 30MHz ~ 1GHz) / 1.5 meters
        (for above 1GHz) above the ground at 3 meters chamber room for test. The table was rotated
        360 degrees to determine the position of the highest radiation.
     b) The EUT was set 3 meters away from the interference-receiving antenna, which was mounted
        on the top of a variable-height antenna tower.
     c) The height of antenna is varied from one meter to four meters above the ground to determine
        the maximum value of the field strength. Both horizontal and vertical polarizations of the
        antenna are set to make the measurement.
     d) For each suspected emission, the EUT was arranged to its worst case and then the antenna was
        tuned to heights from 1 meter to 4 meters and the rotatable table was turned from 0 degrees to
        360 degrees to find the maximum reading.
     e) The test-receiver system was set to quasi-peak detect function and specified bandwidth with
        maximum hold mode when the test frequency is below 1 GHz.
     f)   The test-receiver system was set to peak and average detector function and specified bandwidth
          with maximum hold mode when the test frequency is above 1 GHz. If the peak reading value
          also meets average limit, measurement with the average detector is unnecessary.

Note:
    1.     The resolution bandwidth and video bandwidth of test receiver/spectrum analyzer is 120kHz
           for Quasi-peak detection (QP) at frequency below 1GHz.
     2.    The resolution bandwidth of test receiver/spectrum analyzer is 1 MHz and the video
           bandwidth is 3 MHz for Peak detection (PK) at frequency above 1GHz.
     3.    The resolution bandwidth of test receiver/spectrum analyzer is 1 MHz and the video
           bandwidth is ≥ 1/T (Duty cycle < 98%) or 3 x RBW (Duty cycle ≥ 98%) for Average detection (AV)
           at frequency above 1GHz.
     4.    All modes of operation were evaluated and the worst-case emissions were reported




TTRF15.247-01_V1 © 2018 Intertek                Page 14 of 21


                                                                             Report No.: 190900239SHA-001



TEST REPORT


3.3 Test Configuration
 For Radiated emission below 30MHz:




               EUT&                         3m
               Support Units
                                   Turn Table

                  80cm



                                         Test Receiver




  For Radiated emission 30MHz to 1GHz:


                                                                Ant. Tower         1-4m
                                                                                   Variable
                EUT&                            3m
                Support Units
                                   Turn Table

                   80cm



                                          Test Receiver




TTRF15.247-01_V1 © 2018 Intertek                Page 15 of 21


                                                                         Report No.: 190900239SHA-001



TEST REPORT


  For Radiated emission above 1GHz:


                                                            Ant. Tower         1-4m
                                                                               Variable
                EUT&                        3m
                Support Units
                                   Turn Table
                                                 Absorber
                   150cm



                                         Test Receiver




TTRF15.247-01_V1 © 2018 Intertek            Page 16 of 21


                                                                            Report No.: 190900239SHA-001



TEST REPORT


3.4 Test Results of Radiated Emissions
The low frequency, which started from 9 kHz to 30MHz, was pre-scanned and the result which was 20dB
lower than the limit line per 15.31(o) was not reported.

EUT was tested with WiFi on and off, and the worst data was listed in the report.

Test data below 1GHz:
                                   Corrected
                     Frequency                   Correct Factor      Limit          Margin
   Antenna                          Reading                                                   Detector
                       (MHz)                        (dB/m)         (dBuV/m)          (dB)
                                   (dBuV/m)
       H                31.94        24.90            20.40           40            15.10        PK

       H                86.37        19.60            10.10           40            20.40        PK

       H                156.35       38.50            10.10          43.5            5.00        PK

       H                187.45       41.00            11.10          43.5            2.50        PK

       H                479.04       37.50            18.50           46             8.50        PK

       H                933.91       33.50            25.40           46            12.50        PK

       V                30.00        25.60            21.30           40            14.40        PK

       V                134.97       28.90            11.00          43.5           14.60        PK

       V                193.29       29.10            11.20          43.5           14.40        PK

       V                199.12       30.10            11.20          43.5           13.40        PK

       V                477.09       35.30            18.50           46            10.70        PK

       V                959.18       33.40            25.30           46            12.60        PK

Remark: 1. Correct Factor = Antenna Factor + Cable Loss (+ Amplifier, for higher than 1GHz), the value
           was added to Original Receiver Reading by the software automatically.
        2. Corrected Reading = Original Receiver Reading + Correct Factor
        3. Margin = Limit - Corrected Reading
        4. If the PK Corrected Reading is lower than AV limit, the AV test can be elided.

Example: Assuming Antenna Factor = 30.20dB/m, Cable Loss = 2.00dB,
         Gain of Preamplifier = 32.00dB, Original Receiver Reading = 10.00dBuV,
         Limit = 40.00dBuV/m.
         Then Correct Factor = 30.20 + 2.00 – 32.00 = 0.20dB/m;
         Corrected Reading = 10dBuV + 0.20dB/m = 10.20dBuV/m;
         Margin = 40.00dBuV/m - 10.20dBuV/m = 29.80dB.




TTRF15.247-01_V1 © 2018 Intertek               Page 17 of 21


                                                                              Report No.: 190900239SHA-001



TEST REPORT


4 Power line conducted emission
      Test result:             Pass

4.1 Limit

                                                                   Conducted Limit (dBuV)
       Frequency of Emission (MHz)
                                                              QP                            AV

                     0.15-0.5                         66 to 56*                          56 to 46 *
                       0.5-5                                  56                            46
                       5-30                                   60                            50
* Decreases with the logarithm of the frequency.



4.2 Test Configuration




                                              EUT
                            Peripheral
                             devices




                                   LISN      LISN                         EMI receiver




TTRF15.247-01_V1 © 2018 Intertek              Page 18 of 21


                                                                          Report No.: 190900239SHA-001



TEST REPORT

4.3 Measurement Procedure
   Measured levels of ac power-line conducted emission shall be the emission voltages from the voltage
   probe, where permitted, or across the 50 Ω LISN port (to which the EUT is connected), where
   permitted, terminated into a 50 Ω measuring instrument. All emission voltage and current
   measurements shall be made on each current-carrying conductor at the plug end of the EUT power
   cord by the use of mating plugs and receptacles on the LISN, if used. Equipment shall be tested with
   power cords that are normally supplied or recommended by the manufacturer and that have
   electrical and shielding characteristics that are the same as those cords normally supplied or
   recommended by the manufacturer. For those measurements using a LISN, the 50 Ω measuring port
   is terminated by a measuring instrument having 50 Ω input impedance. All other ports are
   terminated in 50 Ω loads.

   Tabletop devices shall be placed on a platform of nominal size 1 m by 1.5 m, raised 80 cm above the
   reference ground plane. The vertical conducting plane or wall of an RF-shielded (screened) room shall
   be located 40 cm to the rear of the EUT. Floor-standing devices shall be placed either directly on the
   reference ground-plane or on insulating material as described in ANSI C63.4. All other surfaces of
   tabletop or floor-standing EUTs shall be at least 80 cm from any other grounded conducting surface,
   including the case or cases of one or more LISNs.

   The bandwidth of the test receiver is set at 9 kHz.




TTRF15.247-01_V1 © 2018 Intertek                Page 19 of 21


                                                                          Report No.: 190900239SHA-001



TEST REPORT

4.4 Test Results of Power line conducted emission
Test Curve:
                                                   L Line




Test Data:
                                    Quasi-peak                                Average
    Frequency
      (MHz)                 level      Limit         Margin       level         limit       Margin
                           dB(V)     dB(V)          (dB)       dB(V)        dB(V)        (dB)
        0.15                47.33      65.80         18.47        33.67         55.80       22.13
        0.17                45.13     64.94           19.81      33.81         54.94         21.13
        0.51                39.91     56.00           16.09      30.54         46.00         15.46
        0.98                26.09     56.00           29.91      18.90         46.00         27.10
        4.17                34.11     56.00           21.89      24.82         46.00         21.18
       12.60                30.63     60.00           29.37      21.62         50.00         28.38




TTRF15.247-01_V1 © 2018 Intertek                 Page 20 of 21


                                                                          Report No.: 190900239SHA-001



TEST REPORT


Test Curve:
                                                   N Line




Test Data:
                                    Quasi-peak                                Average
    Frequency
      (MHz)                 level      Limit         Margin       level         limit        Margin
                           dB(V)     dB(V)          (dB)       dB(V)        dB(V)         (dB)
        0.16                49.75      65.57         15.82        33.67         55.57        21.90
        0.49                34.11     56.12           22.01       27.27         46.12         18.85
        1.00                27.61     56.00           28.39       18.09         46.00         27.91
        3.50                33.83     56.00           22.17       23.75         46.00         22.25
        3.96                35.09     56.00           20.91       25.27         46.00         20.73
     12.60             25.39         60.00          34.61          18.77          50.00         31.23
Remark: 1. Correct Factor = LISN Factor + Cable Loss, the value was added to Original Receiver Reading
           by the software automatically.
        2. Corrected Reading = Original Receiver Reading + Correct Factor
        3. Margin = Limit - Corrected Reading
        4. If the PK Corrected Reading is lower than AV limit, the AV test can be elided.

 ***************************************** END **************************************


TTRF15.247-01_V1 © 2018 Intertek                 Page 21 of 21



Document Created: 2019-09-29 18:02:02
Document Modified: 2019-09-29 18:02:02

© 2024 FCC.report