LCS190509078AEC_PMR

FCC ID: 2AJTU-S6

Test Report

Download: PDF
FCCID_4353442

SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                          FCC ID: 2AJTU-S6              Report No.: LCS190509078AEC




                                                  FCC TEST REPORT
                                                                For
                         South Surveying & Mapping Technology Co., Ltd.
                                                         Digital radio
                                                        Test Model: S6
                                   List Model No.: Please refer to page 6




   Prepared for                               :     South Surveying & Mapping Technology Co., Ltd.
   Address                                    :     No.39, Sicheng Road, Tianhe District, Guangzhou, China

   Prepared by                                :     Shenzhen LCS Compliance Testing Laboratory Ltd.
   Address                                    :     1/F., Xingyuan Industrial Park, Tongda Road, Bao’an Avenue,
                                                    Bao’an District, Shenzhen, Guangdong, China
   Tel                                        :     (+86)755-82591330
   Fax                                        :     (+86)755-82591332
   Web                                        :     www.LCS-cert.com
   Mail                                       :     webmaster@LCS-cert.com


   Date of receipt of test sample             :     May 28, 2019
   Number of tested samples                   :     1
   Serial number                              :     Prototype
   Date of Test                               :     May 28, 2019~June 14, 2019
   Date of Report                             :     June 20, 2019




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                   Page 1 of 34


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                           FCC ID: 2AJTU-S6              Report No.: LCS190509078AEC


                                                          FCC TEST REPORT
                                                             FCC Part 90
Report Reference No. .................               : LCS190509078AEC

Date of Issue ..................................     : June 20, 2019

Testing Laboratory Name ............                 : Shenzhen LCS Compliance Testing Laboratory Ltd.
Address ..........................................   : 1/F., Xingyuan Industrial Park, Tongda Road, Bao’an Avenue,
                                                       Bao’an District, Shenzhen, Guangdong, China
Testing Location/ Procedure ..........               : Full application of Harmonised standards ■
                                                       Partial application of Harmonised standards □
                                                       Other standard testing method □
Applicant’s Name .........................           : South Surveying & Mapping Technology Co., Ltd.
Address ..........................................   : No.39, Sicheng Road, Tianhe District, Guangzhou, China
Test Specification
                                                         FCC Part 2
Standard.........................................    :
                                                         FCC Part 90
Test Report Form No. ...................             : LCSEMC-1.0

TRF Originator ...............................       : Shenzhen LCS Compliance Testing Laboratory Ltd.

Master TRF ....................................      : Dated 2011-03
Shenzhen LCS Compliance Testing Laboratory Ltd. All rights reserved.
This publication may be reproduced in whole or in part for non-commercial purposes as long as the
Shenzhen LCS Compliance Testing Laboratory Ltd. is acknowledged as copyright owner and source of the
material. Shenzhen LCS Compliance Testing Laboratory Ltd. takes no responsibility for and will not assume
liability for damages resulting from the reader's interpretation of the reproduced material due to its placement
and context.
Test Item Description. ..................            : Digital radio

Trade Mark .....................................     : SOUTH, KOLIDA, SANDING, RUIDE, TIANYU

Test Model .....................................     : S6
Ratings .........................................    : DC 9-16V by external power

Result ………………………......                               : Positive


             Compiled by:                                      Supervised by:                                Approved by:




   Aking Jin/ File administrator                         Leo Lee/ Technique principal                   Gavin Liang/ Manager




    This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                    Page 2 of 34


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                          FCC ID: 2AJTU-S6              Report No.: LCS190509078AEC


                                                    RADIO -- TEST REPORT


                                                                                                  June 20, 2019
      Test Report No. :                LCS190509078AEC                                             Date of issue



    Test Model..............................        : S6

    EUT.........................................    : Digital radio


    Applicant...............................        : South Surveying & Mapping Technology Co., Ltd.
    Address..................................       : No.39, Sicheng Road, Tianhe District, Guangzhou, China
    Telephone...............................        : /
    Fax..........................................   : /


    Manufacturer........................            : Guangzhou South Satellite Navigation Instrument Co., Ltd.
                                                      Area A Layer 6, Area A Layer 5, Area A Layer 4, No.39, Sicheng
    Address..................................       :
                                                      Road, Tianhe District, Guangzhou, China
    Telephone...............................        : /
    Fax..........................................   : /


    Factory...................................      : Guangzhou South Satellite Navigation Instrument Co., Ltd.
    Address..................................       : Area A Layer 6, Area A Layer 5, Area A Layer 4, No.39, Sicheng
                                                      Road, Tianhe District, Guangzhou, China
    Telephone...............................        : /
    Fax..........................................   : /



                       Test Result                                              Positive
   The test report merely corresponds to the test sample.
   It is not permitted to copy extracts of these test result without the written permission of the test laboratory.




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                   Page 3 of 34


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                          FCC ID: 2AJTU-S6              Report No.: LCS190509078AEC


                                                      Revision History
           Revision                        Issue Date                          Revisions                        Revised By
             000                          June 20, 2019                       Initial Issue                     Gavin Liang




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                   Page 4 of 34


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                                         FCC ID: 2AJTU-S6                    Report No.: LCS190509078AEC



                                                         TABLE OF CONTENTS

Test Report Description                                                                                                                           Page
 1.GENERAL INFORMATION ..................................................................................................................... 6
    1.1. DESCRIPTION OF DEVICE (EUT) ........................................................................................................ 6
    1.2. HOST SYSTEM CONFIGURATION LIST AND DETAILS ............................................................................ 6
    1.3. EXTERNAL I/O CABLE ....................................................................................................................... 7
    1.4. DESCRIPTION OF TEST FACILITY ........................................................................................................ 7
    1.5. STATEMENT OF THE MEASUREMENT UNCERTAINTY ............................................................................ 7
    1.6. MEASUREMENT UNCERTAINTY .......................................................................................................... 7
    1.7. DESCRIPTION OF TEST MODES.......................................................................................................... 8
 2.SYSTEM TEST CONFIGURATION ......................................................................................................... 9
    2.1. TEST STANDARDS ....................................................................................................................... 9
    2.2. EUT CONFIGURATION....................................................................................................................... 9
    2.3. EUT EXERCISE ................................................................................................................................ 9
    2.4. GENERAL TEST PROCEDURES ........................................................................................................... 9
    2.5. TEST SAMPLE................................................................................................................................... 9
 3.SYSTEM TEST CONFIGURATION ....................................................................................................... 10
    3.1. JUSTIFICATION ............................................................................................................................... 10
    3.2. EUT EXERCISE SOFTWARE............................................................................................................. 10
    3.3. SPECIAL ACCESSORIES .................................................................................................................. 10
    3.4. BLOCK DIAGRAM/SCHEMATICS ........................................................................................................ 10
    3.5. EQUIPMENT MODIFICATIONS ........................................................................................................... 10
    3.6. TEST SETUP ................................................................................................................................... 10
 4.SUMMARY OF TEST RESULT ............................................................................................................. 11
 5.TEST CONDITIONS AND RESULTS .................................................................................................... 12
     5.1. MAXIMUM TRANSMITTER POWER ..................................................................................................... 12
     5.2. OCCUPIED BANDWIDTH AND EMISSION MASK TEST .......................................................................... 14
     5.3. TRANSMITTER RADIATED SPURIOUS EMISSION ................................................................................ 19
     5.4. SPURIOUS EMISSION ON ANTENNA PORT ......................................................................................... 23
     5.5. MODULATION CHARACTERISTICS - MODULATION LIMITING ................................................................ 28
     5.6. FREQUENCY STABILITY TEST .......................................................................................................... 29
     5.7. TRANSMITTER FREQUENCY BEHAVIOR ............................................................................................. 31
 6.LIST OF MEASURING EQUIPMENT .................................................................................................... 33
 7.TEST SETUP PHOTOGRAPHS OF EUT .............................................................................................. 34
 8.EXTERIOR PHOTOGRAPHS OF THE EUT ......................................................................................... 34
 9.INTERIOR PHOTOGRAPHS OF THE EUT .......................................................................................... 34




    This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                    Page 5 of 34


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                          FCC ID: 2AJTU-S6              Report No.: LCS190509078AEC



1. GENERAL INFORMATION
  1.1. Description of Device (EUT)
 Name of EUT                                      Digital radio
 Model No.                                        S6, S1, MDL, GDL20, N80, N80T, N80P
 Model Declaration                                PCB board, structure and internal of these model(s) are the same,
                                                  so no additional models were tested
 Test Model                                       S6
 Power Supply                                     DC 9-16V by external power
 Hardware version                                 Beaver7_35w_v1r2
 Software version                                 1.09.190524.RG60GL.CUS
 BT FCC Operation frequency                       2402-2480MHz
 BT FCC Modulation Type                           GFSK, π/4-DQPSK, 8-DPSK
 Bluetooth Version                                V3.0
 Antenna Type                                     Ceramic Antenna
 Antenna Gain                                     2.0dBi (max.) for Bluetooth
 WLAN FCC Operation frequency                     IEEE 802.11b/g/n HT20:2412-2462MHz
 WLAN FCC Modulation Type                         IEEE 802.11b: DSSS(CCK,DQPSK,DBPSK)
                                                  IEEE 802.11g/n: OFDM(64QAM, 16QAM, QPSK, BPSK)
 Antenna Type                                     Ceramic Antenna
 Antenna Gain                                     2.0dBi (max.) for WLAN
 PMR FCC Operation frequency                      410.125-469.625MHz
 Channel Separation                               0.5MHz
 Channel Number                                   120
 Channel Bandwidth                                25KHz
 Modulation Type                                  GMSK
 Emission Designator                              16K0G1D for GMSK Modulation at 25KHz Channel Separation
 Rate Power                                       30W/20W/10W
 Antenna Type                                     External Antenna
 Antenna Gain                                     5.0dBi (max.) for PMR
 Extreme temp. Tolerance                          -20°C to +55°C
 Extreme Voltage Tolerance                        DC 9V to 16V


  1.2. Host System Configuration List and Details
               Manufacturer                       Description                 Model            Serial Number          Certificate
                 Lenovo                              PC                       B470                    --                DOC
                                                   AC/DC
                   Lenovo                                                ADP-90DDB                     --                DOC
                                                  ADAPTER




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                   Page 6 of 34


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                          FCC ID: 2AJTU-S6              Report No.: LCS190509078AEC



  1.3. External I/O Cable
            I/O Port Description                            Quantity                                 Cable
               Antenna Port                                   1                              RF Cable: 3.0m, shielded
        5-pin power cable socket                                 1                         Power Cable: 2.0m, shielded
         5-pin data cable socket                                 1                                         N/A
         7-pin data cable socket                                 1                                         N/A

  1.4. Description of Test Facility
    FCC Registration Number is 254912.
    Industry Canada Registration Number is 9642A-1.
    ESMD Registration Number is ARCB0108.
    UL Registration Number is 100571-492.
    TUV SUD Registration Number is SCN1081.
    TUV RH Registration Number is UA 50296516-001.
    NVLAP Registration Code is 600167-0.
    FCC Designation Number is CN5024.
    CAB identifier is CN0071.
    The 3m-Semi anechoic test site fulfils CISPR 16-1-4 according to ANSI C63.4:2014 and CISPR
    16-1-4:2010 SVSWR requirement for radiated emission above 1GHz.

  1.5. Statement of the Measurement Uncertainty
    The data and results referenced in this document are true and accurate. The reader is cautioned that
    there may be errors within the calibration limits of the equipment and facilities. The measurement
    uncertainty was calculated for all measurements listed in this test report acc. To CISPR 16 – 4
    “Specification for radio disturbance and immunity measuring apparatus and methods – Part 4: Uncertainty
    in EMC Measurements” and is documented in the LCS quality system acc. To DIN EN ISO/IEC 17025.
    Furthermore, component and process variability of devices similar to that tested may result in additional
    deviation. The manufacturer has the sole responsibility of continued compliance of the device.

  1.6. Measurement Uncertainty
                         Test Item                                                    Uncertainty                        Note
                     Frequency error                                                    30 Hz                             (1)
               Transmitter power conducted                                             0.62 dB                            (1)
                Transmitter power Radiated                                             2.67 dB                            (1)
       Conducted spurious emission 9KHz-12.75 GHz                                      1.88 dB                            (1)
            Conducted Emission 9KHz-30MHz                                              1.63 dB                            (1)
         Radiated spurious emission 30~1000MHz                                         4.65 dB                            (1)
          Radiated spurious emission 1~18GHz                                           3.89 dB                            (1)
          Radiated spurious emission 18-40GHz                                          3.90 dB                            (1)
                   Occupied Bandwidth                                                    N/A                             N/A
                     Emission Mask                                                       N/A                             N/A
                 Modulation Characteristic                                               N/A                             N/A
             Transmitter Frequency Behavior                                              N/A                             N/A
    (1). This uncertainty represents an expanded uncertainty expressed at approximately the 95% confidence
         level using a coverage factor of k=2.




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                   Page 7 of 34


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                          FCC ID: 2AJTU-S6              Report No.: LCS190509078AEC



  1.7. Description of Test Modes
    The EUT has been tested under typical operating condition. As, test modes selected as below by the
    technical parameters of the EUT:
     Operation Description of operation
                                        Additional information
       Mode              mode
                                        The EUT is set with GMSK modulation and 25KHz bandwidth
        TM1       GMSK+BW25KHz+TX at maximum rated power for transmitter, powered by DC 12V
                                        external power
                                        The EUT is set with GMSK modulation and 25KHz bandwidth
        TM2       GMSK+BW25KHz+TX at minimum rated power for transmitter, powered by DC 12V
                                        external power

    Frequency list:
        Modulation             Channel                                 Frequency                                 Frequency
                                                    Channel                                   Channel
          Type                Separation                                 (MHz)                                     (MHz)
                                                         1              410.125                   …                  …
                                                         2              410.625                  114              466.625
                                                         3              411.125                  115              467.125
                                                         4              411.625                  116              469.625
            GMSK                 25KHz
                                                         5              412.125                  117              468.125
                                                         6              412.625                  118              468.625
                                                        …                  …                     119              469.125
                                                        93              440.125                  120              469.625

    Note: The line display in grey was the channel selected for test.




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                   Page 8 of 34


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                          FCC ID: 2AJTU-S6              Report No.: LCS190509078AEC



2. SYSTEM TEST CONFIGURATION
  2.1. TEST STANDARDS
    The tests were performed according to following standards:
    FCC Rules Part 90: PRIVATE LAND MOBILE RADIO SERVICES.
    ANSI/TIA-603-E-2016: Land Mobile FM or PM Communications Equipment Measurement and
    Performance Standards.
    47 CFR FCC Part 15 Subpart B: Unintentional Radiators
    FCC Part 2: FREQUENCY ALLOCA-TIONS AND RADIO TREATY MAT-TERS; GENERAL RULES AND
    REG-ULATIONS
    ANSI C63.26:2015: American National Standard for Compliance Testing of Transmitters Used in Licensed
    Radio Services.
    ANSI C63.10: 2013: American National Standard for Testing Unlicensed Wireless Devices

  2.2. EUT Configuration
    The EUT configuration for testing is installed on RF field strength measurement to meet the Commissions
    requirement and operating in a manner that intends to maximize its emission characteristics in a
    continuous normal application.

  2.3. EUT Exercise
    The EUT has been tested under typical operating condition and The Transmitter was operated in the
    normal operating mode. The TX frequency was fixed which was for the purpose of the measurements.

  2.4. General Test Procedures
   2.4.1 Conducted Emissions

    N/A
   2.4.2 Radiated Emissions

    The EUT is placed on a turntable, which is directly placed on the ground. The turntable shall rotate 360
    degrees to determine the position of maximum emission level. EUT is set 3m away from the receiving
    antenna, which varied from 1m to 4m to find out the highest emission. And also, each emission was to be
    maximized by changing the polarization of receiving antenna both horizontal and vertical. In order to find
    out the maximum emissions, exploratory radiated emission measurements were made according to the
    requirements in Section 6.3 of ANSI C63.10-2013

  2.5. Test Sample
    The application provides 1 samples to meet requirement;

          Sample Number                          Description
          Sample 1                               continuous transmit




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                   Page 9 of 34


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                          FCC ID: 2AJTU-S6              Report No.: LCS190509078AEC



3. SYSTEM TEST CONFIGURATION

  3.1. Justification
    The system was configured for testing in a continuous transmits condition.

  3.2. EUT Exercise Software
    N/ A

  3.3. Special Accessories
    N/ A

  3.4. Block Diagram/Schematics
    Please refer to the related document

  3.5. Equipment Modifications
    Shenzhen LCS Compliance Testing Laboratory Ltd. has not done any modification on the EUT.

  3.6. Test Setup
    Please refer to the test setup photo.




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                   Page 10 of 34


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                          FCC ID: 2AJTU-S6              Report No.: LCS190509078AEC



4. SUMMARY OF TEST RESULT
                                              Applied Standard: FCC Part 90
              FCC Rules                    Description of Test                  Test Sample             Result         Remark
                                          Maximum Transmitter
           FCC Part 90.205                                                        Sample 1           Compliant          Note 1
                                                  Power
         FCC Part 90.207                Modulation Characteristics -
                                                                                  Sample 1               N/A*           Note 2
        FCC Part 2.1047 (a)             Audio Frequency Response
         FCC Part 90.207                Modulation Characteristics -
                                                                                  Sample 1           Compliant          Note 1
        FCC Part 2.1047 (b)                 Modulation Limiting
         FCC Part 90.209                   Occupied Bandwidth                     Sample 1           Compliant          Note 1
         FCC Part 90.210                      Emission Mask                       Sample 1           Compliant          Note 1
         FCC Part 90.213                    Frequency Stability                   Sample 1           Compliant          Note 1
                                          Transmitter Frequency
           FCC Part 90.214                                                        Sample 1           Compliant          Note 1
                                                 Behavior
                                           Transmitter Radiated
           FCC Part 90.210                                                        Sample 1           Compliant          Note 1
                                            Spurious Emission
                                          Spurious Emission On
           FCC Part 90.210                                                        Sample 1           Compliant          Note 1
                                               Antenna Port
     Remark:
     1. Note 1 – Test results inside test report;
     2. Note 2 – N/A* - Not Applicable for this device.




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                   Page 11 of 34


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                          FCC ID: 2AJTU-S6              Report No.: LCS190509078AEC



5. TEST CONDITIONS AND RESULTS
  5.1. Maximum Transmitter Power
   5.1.1 Test Applicable
    Per FCC Part 2.1046 and Part 90.205: Maximum ERP is dependent upon the station’s antenna HAAT and
    required service area.
   5.1.2 Test Procedure
    Measurements shall be made to establish the radio frequency power delivered by the transmitter the
    standard output termination. The power output shall be monitored and recorded and no adjustment shall
    be made to the transmitter after the test has begun, except as noted bellow:
    If the power output is adjustable, measurements shall be made for the highest and lowest power levels.
    The EUT connect to the Receiver through 20 dB attenuator.
    Measurement with Spectrum Analyzer conducted external power supply with 12V stabilized supply voltage.
   5.1.3 Test Configuration

                                                                            20dB                  Spectrum
                            PC                      EUT
                                                                         Attenuator               Analyzer



                                                Modulating
                                                 Signal
                                                Generator

   5.1.4 Test Results

           Temperature                          24.5℃                         Humidity                        54.1%
           Test Engineer                       Scent Hu                      Test Voltage                 Normal Voltage

                                                              Test       Test        Test
     Modulation         Channel          Operation         Test                                Limit
                                                          Frequency     Results   Results
       Type            Separation         Mode            Channel                              (W)
                                                             (MHz)      (dBm)        (W)
                                                Ch1         410.125     44.253     26.626      250
                                    TM1        Ch93         456.125     44.442     27.810      500
        Digital                               Ch120         469.625     44.479     28.048      500
                     25KHz
        GMSK                                    Ch1         410.125     39.712      9.358      250
                                    TM2        Ch93         456.125     39.876      9.719      500
                                              Ch120         469.625     39.877      9.721      500
         Limit     The limit is dependent upon the station’s antenna HAAT and required service area.
            Test Results                                         PASS

    Remark:
    1. The station’s antenna high (HAAT) is 15m and the service area radius is 15Km;
    2. Please refer to following plot.




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                   Page 12 of 34


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                          FCC ID: 2AJTU-S6              Report No.: LCS190509078AEC


                                                        Transmitter Power
                              TM1                                                                    TM2




                Channel 1 / 410.125 MHz                                                Channel 1 / 410.125 MHz




               Channel 93 / 456.125 MHz                                               Channel 93 / 456.125 MHz




              Channel 120 / 469.625 MHz                                              Channel 120 / 469.625 MHz




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                   Page 13 of 34


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                          FCC ID: 2AJTU-S6              Report No.: LCS190509078AEC



  5.2. Occupied Bandwidth and Emission Mask Test
   5.2.1 Test Applicable
    (a). Occupied Bandwidth: The EUT was connected to the audio signal generator and the spectrum
         analyser via the main RF connector, and through an appropriate attenuator. The EUT was controlled
         to transmit its maximum power. Then the bandwidth of 99% power can be measured by the
         spectrum analyser.
    (b). Emission Mask B: For transmitters that are equipped with an audio low-pass filter pursuant to
        §90.211(a), the power of any emission must be below the unmodulated carrier power (P) as follows:
       (1) On any frequency removed from the assigned frequency by more than 50 percent, but not more
           than 100 percent of the authorized bandwidth: At least 25dB.
       (2) On any frequency removed from the assigned frequency by more than 100 percent, but not more
           than 250 percent of the authorized bandwidth: At least 35dB.
       (3) On any frequency removed from the assigned frequency by more than 250 percent of the
           authorized bandwidth: At least 43 + 10 log (P) dB.
    (c). Emission Mask D, 12.5 kHz channel bandwidth equipment: For transmitters designed to operate with
        a 12.5 kHz channel bandwidth, any emission must be attenuated below the power (P) of the highest
        emission contained within the authorized bandwidth as follows:
       (1) On any frequency from the centre of the authorized bandwidth f0 to 5.625 kHz removed from f0:
           Zero dB.
       (2) On any frequency removed from the centre of the authorized bandwidth by a displacement
           frequency (fd in kHz) of more than 5.625 kHz but no more than 12.5 kHz: At least 7.27(fd - 2.88 kHz)
           dB.
       (3) On any frequency removed from the centre of the authorized bandwidth by a displacement
           frequency (fd in kHz) of more than 12.5 kHz: At least 50 + 10 log (P) dB or 70 dB, whichever is the
           lesser attenuation.
   5.2.2 Test Configuration

                                                                            20dB                  Spectrum
                            PC                      EUT
                                                                         Attenuator               Analyzer



                                                Modulating
                                                 Signal
                                                Generator

   5.2.3 Test Procedure
    1   Set EUT as normal operation.
    2   Set SPA Centre Frequency = fundamental frequency, RBW=300Hz, VBW= 1 KHz, span =50 KHz for
        channel bandwidth 12.5 KHz and 100 KHz for channel bandwidth 25 KHz.
    3   Set SPA Max hold. Mark peak, Set 99% Occupied Bandwidth and 26dB Occupied Bandwidth.




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                   Page 14 of 34


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                          FCC ID: 2AJTU-S6              Report No.: LCS190509078AEC



   5.2.4 Test Results

           Temperature                          24.5℃                         Humidity                        54.1%
           Test Engineer                       Scent Hu                      Test Voltage                 Normal Voltage

    Occupied Bandwidth
                                                                                        Occupied Bandwidth
      Modulation          Channel         Operation         Test           Test Frequency
                                                                                               (KHz)
        Type             Separation        Mode            Channel              (MHz)
                                                                                         99%          26dB
                                                              Ch1         410.125       16.477        18.54
         GMSK              25 KHz            TM1             Ch93         456.125       16.293        18.61
                                                             Ch120        469.625       16.371        18.51
                         Limit                                     20KHz for 25KHz Channel Separation
                      Test Results                                               PASS

    Remark:
    1. Measured at TM1 to TM2, recorded worst case at TM1;
    2. Please refer to following plots.




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                   Page 15 of 34


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                          FCC ID: 2AJTU-S6              Report No.: LCS190509078AEC


                                                   99% and 26dB Bandwidth
                              TM1                                                                      /




                                                                                                       /




                Channel 1 / 410.125 MHz                                                                /




                                                                                                       /




               Channel 93 / 456.125 MHz                                                                /




                                                                                                       /




              Channel 120 / 469.625 MHz                                                                /




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                   Page 16 of 34


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                          FCC ID: 2AJTU-S6              Report No.: LCS190509078AEC


           Temperature                          24.5℃                         Humidity                        54.1%
           Test Engineer                       Scent Hu                      Test Voltage                 Normal Voltage

    Emission Mask
     Modulation   Channel                Operation          Test          Test Frequency  Applicable                    RBW
       Type     Separation                Mode            Channel              (MHz)        Mask                        (Hz)
                                                            Ch1              410.125          B                         300
        GMSK             25 KHz             TM1            Ch93              456.125          B                         300
                                                           Ch120             469.625          B                         300
                     Test Results                                                    PASS

    Remark:
    1. Measured at TM1 to TM2, recorded worst case at TM1;
    2. Please refer to following plots.




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                   Page 17 of 34


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                          FCC ID: 2AJTU-S6              Report No.: LCS190509078AEC


                                                          Emission Mask
                              TM1                                                                      /




                                                                                                       /




                Channel 1 / 410.125 MHz                                                                /




                                                                                                       /




               Channel 93 / 456.125 MHz                                                                /




                                                                                                       /




              Channel 120 / 469.625 MHz                                                                /




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                   Page 18 of 34


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                          FCC ID: 2AJTU-S6              Report No.: LCS190509078AEC



  5.3. Transmitter Radiated Spurious Emission
   5.3.1 Test Applicable
    According to the ANSI C63.26:2015 test method, and according to Section 90.210, the power of each
    unwanted emission shall be less than Transmitted Power as specified below for transmitters designed to
    operate with 12.5 KHz channel bandwidth:
    1 On any frequency removed from the centre of the authorized bandwidth fo to 5.625 KHz removed
         from fo: Zero dB
    2 On any frequency removed from the centre of the authorized bandwidth by a displacement frequency
         (fd in KHz) fo of more than 5.625 KHz but no more than 12.5 KHz: At least 7.27dB
    3 On any frequency removed from the centre of the authorized bandwidth by a displacement frequency
         (fd in KHz) fo of more than 12.5 KHz: At least 50+10 log (P) dB or 70 dB, whichever is lesser
         attenuation.
    For transmitters designed to transmit with 25 KHz channel separation and equipped with an audio
    low-pass filter, the power of any emission must be attenuated below the unmodulated carrier power (P) as
    following:
    1 On any frequency removed from the assigned frequency by more than 50 percent, but no more than
         100 percent of the authorized bandwidth: At least 25 dB.
    2 On any frequency removed from the assigned frequency by more than 100 percent, but no more than
         250 percent of the authorized bandwidth: At least 35 dB.
    3 On any frequency removed from the assigned frequency by more than 250 percent of the authorized
         bandwidth: At least 43+10log (P) dB.

   5.3.2 Test Configuration




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                   Page 19 of 34


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                          FCC ID: 2AJTU-S6              Report No.: LCS190509078AEC



   5.3.3 Test Arrangement


      Test Chamber


                                                      Test Antenna
                                         50Ω                                               High Pass
         PC              EUT
                                         Load                                                Filter




                                                                                                                    Spectrum
                                                                                            Pre. Amp.
                                                                                                                    Analyzer



   5.3.4 Test Procedure

    1. EUT was placed on a 1.50 meter high non-conductive stand at a 3 meter test distance from the
       receive antenna. A receiving antenna was placed on the antenna mast 3 meters from the EUT for
       emission measurements. The height of receiving antenna is 1.50 m. Detected emissions were
       maximized at each frequency by rotating the EUT through 360° and adjusting the receiving antenna
       polarization. The radiated emission measurements of all transmit frequencies in six channels were
       measured with peak detector.
    2. A log-periodic antenna or double-ridged waveguide horn antenna shall be substituted in place of the
       EUT. The log-periodic antenna will be driven by a signal generator and the level will be adjusted till
       the same power value on the spectrum analyzer or receiver. The level of the spurious emissions can
       be calculated through the level of the signal generator, cable loss, the gain of the substitution
       antenna and the reading of the spectrum analyzer or receiver.
    3. The EUT is then put into continuously transmitting mode at its maximum power level during the test.
       Set Test Receiver or Spectrum RBW=1MHz, VBW=3MHz for above 1GHz and RBW=100 KHz,
       VBW=300 KHz for 30MHz to 1GHz, and the maximum value of the receiver should be recorded as
       (Pr).
    4. The EUT shall be replaced by a substitution antenna. In the chamber, a substitution antenna for the
       frequency band of interest is placed at the reference point of the chamber. An RF Signal source for
       the frequency band of interest is connected to the substitution antenna with a cable that has been
       constructed to not interfere with the radiation pattern of the antenna. A power (PMea) is applied to the
       input of the substitution antenna, and adjusts the level of the signal generator output until the value of
       the receiver reach the previously recorded (Pr). The power of signal source (PMea) is recorded. The
       test should be performed by rotating the test item and adjusting the receiving antenna polarization.
    5. An amplifier should be connected to the Signal Source output port. And the cable should be
       connecting between the Amplifier and the Substitution Antenna. The cable loss (Pcl), the Substitution
       Antenna Gain (Ga) and the Amplifier Gain (PAg) should be recorded after test.
       The measurement results are obtained as described below:
       Power (EIRP) = PMea- PAg - Pcl - Ga
       The measurement results are amending as described below:
       Power (EIRP) = PMea- Pcl - Ga

   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                   Page 20 of 34


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                          FCC ID: 2AJTU-S6              Report No.: LCS190509078AEC

    6. This value is EIRP since the measurement is calibrated using an antenna of known gain (2.15 dBi)
       and known input power.
    7. ERP can be calculated from EIRP by subtracting the gain of the dipole, ERP = EIRP-2.15dBi.

   5.3.5 Limit
    Modulation Type: GMSK

    FCC Part 22.359, 74.462, 80.211 and 90.210 and RSS Gen, RSS 119 Issue 12:

    For 25 kHz bandwidth:
    On any frequency removed from the center of the authorized bandwidth by a displacement frequency (fd
    in kHz) of more than 62.5 kHz at least:
    High: 43 + 10 log (Pwatts) = 43 + 10 log (30) = 57.77 dB
    Low: 43 + 10 log (Pwatts) = 43 + 10 log (10) = 53.00 dB
    Note: In general, the worst case attenuation requirement shown above was applied.
    Calculation: Limit (dBm) =EL-43-10log10 (TP)
    In this application, the EL is 43.98 dBm for High rated power and 40.00 for lower rated power.
    High: Limit (dBm) = 47.77 – 43 – 10log (30) = -13 dBm
    Low: Limit (dBm) = 40.00 – 43 – 10log (10) = -13 dBm

    Note: 1. In general, the worst case attenuation requirement shown above was applied.
         2. The measurement frequency range from 9 KHz to 5 GHz.
         3. *** means that the emission level is too low to be measured or at least 20 dB down than the limit.
         4. ERP for below 1GHz and EIRP above 1GHz.

   5.3.5 Test Results

           Temperature                          24.5℃                         Humidity                        54.1%
           Test Engineer                       Scent Hu                      Test Voltage                 Normal Voltage

    Remark:
    1. Measured at TM1 to TM2, recorded worst case at TM1;
    2. Please refer to following page.




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                   Page 21 of 34


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                          FCC ID: 2AJTU-S6              Report No.: LCS190509078AEC


                                                    Modulation Type: GMSK
           Operation Mode: TM1                                                 Channel Separation:25KHz
          Test Channel: Channel 1                                             Test Frequency:410.125MHz
Frequency     PMea        Path                     Antenna         Correction   Peak EIRP      Limit
                                                                                                        Polarization
  (MHz)      (dBm)        Loss                      Gain             (dB)         (dBm)       (dBm)
 820.250    -50.42        0.87                      6.42             2.15         -40.98      -13.00         H
1230.375    -58.01        1.02                      7.35             2.15         -47.49      -13.00         H
1640.500    -46.82        1.10                      8.26             2.15         -35.31      -13.00         H
 820.250    -52.41        0.87                      6.42             2.15         -42.97      -13.00         V
1230.375    -41.73        1.02                      7.35             2.15         -31.21      -13.00         V
1640.500    -53.44        1.10                      8.26             2.15         -41.93      -13.00         V

                                                    Modulation Type: GMSK
               Operation Mode: TM1                                             Channel Separation:25KHz
             Test Channel: Channel 93                                         Test Frequency: 456.125MHz
Frequency         PMea       Path                  Antenna         Correction   Peak EIRP       Limit
                                                                                                         Polarization
  (MHz)         (dBm)        Loss                   Gain             (dB)         (dBm)        (dBm)
 912.250        -50.43       0.92                   6.80             2.15         -40.56       -13.00         H
1368.375        -53.22       1.06                   7.89             2.15         -42.12       -13.00         H
1824.500        -47.24       1.12                   8.12             2.15         -35.85       -13.00         H
 912.250        -55.11       0.92                   6.80             2.15         -45.24       -13.00         V
1368.375        -44.15       1.06                   7.89             2.15         -33.05       -13.00         V
1824.500        -50.58       1.12                   8.12             2.15         -39.19       -13.00         V

                                    Modulation Type: GMSK
            Operation Mode: TM1                            Channel Separation:25KHz
          Test Channel: Channel 120                       Test Frequency: 469.625MHz
Frequency      PMea        Path     Antenna    Correction   Peak EIRP       Limit
                                                                                     Polarization
  (MHz)       (dBm)        Loss      Gain         (dB)        (dBm)        (dBm)
 939.250      -45.34       0.95      6.80         2.15        -35.44       -13.00         H
1408.875      -55.97       1.10      7.91         2.15        -44.81       -13.00         H
1878.500      -50.73       1.21      8.25         2.15        -39.12       -13.00         H
 939.250      -59.06       0.95      6.80         2.15        -49.16       -13.00         V
1408.875      -41.70       1.10      7.91         2.15        -30.54       -13.00         V
1878.500      -60.12       1.21      8.25         2.15        -48.51       -13.00         V


    Notes:
    1). Measuring frequencies from 9 KHz~10th harmonic (ex. 26GHz), No emission found between lowest
    internal used/generated frequency to 30MHz;
    2). Radiated emissions measured in frequency range from 9 KHz~10th harmonic (ex. 26GHz) were
    made with an instrument using Peak detector mode;
    3). Peak EIRP = PMea + Path Loss + Antenna Gain + Correction Value (2.15).




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                   Page 22 of 34


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                          FCC ID: 2AJTU-S6              Report No.: LCS190509078AEC



  5.4. Spurious Emission on Antenna Port
   5.4.1 Test Applicable
    The same as Section 5.3

   5.4.2 Test Procedure
    The RF output of the EUT was connected to a spectrum analyzer through appropriate attenuation. The
    resolution bandwidth of the spectrum analyzer was set to 100 kHz. Sufficient scans were taken to show
    any out of band emission up to 10th. Harmonic for the lower and the highest frequency range. Set RBW
    1KHz, VBW 3KHz in the frequency band 9KHz to 150KHz, set RBW 10KHz, VBW 30 KHz in the
    frequency band 150KHz to 30 MHz, set RBW 100 kHz, VBW 300 kHz in the frequency band 30MHz to
    1GHz,while set RBW=1MHz.VBW=3MHz from the 1GHz to 10th Harmonic.
    The audio input was set to 0 to get the unmodulated carrier, the resulting picture is print out for each
    channel separation.

   5.4.3 Test Configuration

                                                                            20dB                  Spectrum
                            PC                      EUT
                                                                         Attenuator               Analyzer



                                                Modulating
                                                 Signal
                                                Generator

   5.4.4 Limit
    Modulation Type: GMSK

    FCC Part 22.359, 74.462, 80.211 and 90.210 and RSS Gen, RSS 119 Issue 12:

    For 25 kHz bandwidth:
    On any frequency removed from the center of the authorized bandwidth by a displacement frequency (fd
    in kHz) of more than 62.5 kHz at least:
    High: 43 + 10 log (Pwatts) = 43 + 10 log (30) = 57.77 dB
    Low: 43 + 10 log (Pwatts) = 43 + 10 log (10) = 53.00 dB
    Note: In general, the worst case attenuation requirement shown above was applied.
    Calculation: Limit (dBm) =EL-43-10log (TP)
    In this application, the EL is 43.98 dBm for High rated power and 40.79 dBm for lower rated power.
    High: Limit (dBm) = 47.77 – 43 – 10log (30) = -13 dBm
    Low: Limit (dBm) = 40.00 – 43 – 10log (10) = -13 dBm

    Note: 1. In general, the worst case attenuation requirement shown above was applied.
         2. The measurement frequency range from 9 KHz to 6GHz.




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                   Page 23 of 34


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                          FCC ID: 2AJTU-S6              Report No.: LCS190509078AEC



   5.4.5 Test Results

           Temperature                          24.5℃                         Humidity                        54.1%
           Test Engineer                       Scent Hu                      Test Voltage                 Normal Voltage

                                        Test             Measured                 Spurious RF
     Operation         Test                                                                                  Limits
                                     Frequency           Frequency             Conducted Emission                        Verdict
      Mode            Channel                                                                                (dBc)
                                       (MHz)               Range                     (dBc)
                        Ch1           410.125          9 KHz – 6 GHz                  <-13
         TM1           Ch93           456.125          9 KHz – 6 GHz                  <-13                     -13        PASS
                       Ch120          469.625          9 KHz – 6 GHz                  <-13

    Remark:
    1. Measured at TM1 to TM2, recorded worst case at TM1;
    2. Please refer to following plot.




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                   Page 24 of 34


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                          FCC ID: 2AJTU-S6              Report No.: LCS190509078AEC


                                             Spurious Emission on Antenna Port
                                               TM1 / Channel 1 / 410.125 MHz




                     9 KHz – 150 KHz                                                        150 KHz – 30 MHz




                   30 MHz – 600 MHz                                                       600 MHz – 1000 MHz




                      1 GHz – 3 GHz                                                           3 GHz – 5 GHz




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                   Page 25 of 34


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                          FCC ID: 2AJTU-S6              Report No.: LCS190509078AEC


                                             Spurious Emission on Antenna Port
                                               TM1 / Channel 93 / 456.125 MHz




                     9 KHz – 150 KHz                                                        150 KHz – 30 MHz




                   30 MHz – 600 MHz                                                       600 MHz – 1000 MHz




                      1 GHz – 3 GHz                                                           3 GHz – 5 GHz




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                   Page 26 of 34


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                          FCC ID: 2AJTU-S6              Report No.: LCS190509078AEC


                                             Spurious Emission on Antenna Port
                                              TM1 / Channel 120 / 469.625 MHz




                     9 KHz – 150 KHz                                                        150 KHz – 30 MHz




                   30 MHz – 600 MHz                                                       600 MHz – 1000 MHz




                      1 GHz – 3 GHz                                                           3 GHz – 5 GHz




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                   Page 27 of 34


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                          FCC ID: 2AJTU-S6              Report No.: LCS190509078AEC



  5.5. Modulation Characteristics - Modulation Limiting
   5.5.1 Test Applicable
    § 2.1047(b): Equipment which employs modulation limiting. A curve or family of curves showing the
    percentage of modulation versus the modulation input voltage shall be supplied. The information
    submitted shall be sufficient to show modulation limiting capability throughout the range of modulating
    frequencies and input modulating signal levels employed.
    Recommended frequency deviation characteristics are given below:
     1.25 kHz for 6.25 kHz Channel Spacing System
     2.5 KHz for 12.5 kHz Channel Spacing System
     5 kHz for 25 kHz Channel Spacing System

   5.5.2 Test Procedure
    For Audio Transmitter: The carrier frequency deviation was measured with the tone input signal level
    varied from 0 Vp to audio input rating level plus 16 dB at frequencies 0.1, 0.5, 1.0, 3.0 and 5.0 kHz. The
    maximum deviation was recorded at each test condition.
    For Data Transmitter with Maximum Frequency Deviation set by Factory: The EUT was set at maximum
    frequency deviation, and its peak frequency deviation was then measured using EUT’s internal random
    data source.

   5.5.3 Test Configuration

                                                                            20dB
                            PC                      EUT                                              3920
                                                                         Attenuator



                                                Modulating
                                                 Signal
                                                Generator


   5.5.4 Test Results

           Temperature                          24.5℃                         Humidity                        54.1%
           Test Engineer                       Scent Hu                      Test Voltage                 Normal Voltage

    Data Modulation Limiting for 25 kHz Channel Spacing Operation

             Operating Mode                           Data Rate                        Peak Frequency Deviation (KHz)
                 GMSK                           19.2 kbps random data                              2.34




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                   Page 28 of 34


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                          FCC ID: 2AJTU-S6              Report No.: LCS190509078AEC



  5.6. Frequency Stability Test
   5.6.1 Test Applicable
    1   According to FCC Part 2 Section 2.1055 (a) (1), the frequency stability shall be measured with
        variation of ambient temperature from -30℃ to +60℃ centigrade.
    2   According to FCC Part 2 Section 2.1055 (e) (2), for battery powered equipment, the frequency
        stability shall be measured with reducing primary supply voltage to the battery operating end point,
        which is specified by the manufacture.
    3   Vary primary supply voltage from 85 to 115 percent of the nominal value.
    4   According to §90.213, the frequency stability limit is 2.5 ppm for 12.5KHz and 5.0ppm for 25KHz
        channel separation

   5.6.2 Test Procedure
    The EUT was set in the climate chamber and connected to an external DC power supply and AC power
    supply. The RF output was directly connected to Spectrum Analyzer ESCI3. The coupling loss of the
    additional cables was recorded and taken in account for all the measurements. After temperature
    stabilization (approx. 20 min for each stage), the frequency for the lower, the middle and the highest
    frequency range was recorded. For Frequency stability Vs. Voltage the EUT was connected to a DC
    power supply or AC power supply and the voltage was adjusted in the required ranges. The result was
    recorded.

   5.6.3 Test Configuration

                                        Environmental Chamber


                   Power                                                         20dB                    Spectrum
                                                  EUT
                   Supply                                                     Attenuator                 Analyzer




   5.6.4 Test Limits
    According to 90.213, Transmitters used must have minimum frequency stability as specified in the
    following table.

                                                                       Frequency Tolerance (ppm)
    Frequency Range           Channel Bandwidth       Fixed and Base                     Mobile Stations
                                                           Station                  > 2W                     2W
                                     6.25                    1.0                     2.0                     2.0
        150-174MHz                   12.5                    2.5                     5.0                     5.0
                                      25                     5.0                     5.0                    50.0*
                                     6.25                    0.5                     1.0                     1.0
        421-512MHz                   12.5                    1.5                     2.5                     2.5
                                      25                     2.5                     5.0                     5.0
    * Stations operating in the 154.45 MHz or the 173.2 to 173.4 MHz bands must have a frequency stability of 5 ppm.
    * Paging transmitters operating on paging-only frequencies must operate with frequency stability of 5 ppm in the 150-174
       MHz band and 2.5 ppm in the 421-512 MHz band.




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                   Page 29 of 34


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                          FCC ID: 2AJTU-S6              Report No.: LCS190509078AEC



   5.6.5 Test Results

           Temperature                          24.5℃                         Humidity                        54.1%
           Test Engineer                       Scent Hu                      Test Voltage                 Normal Voltage

        Operation          Channel                  Test conditions                         Frequency error (ppm)
         Mode             Separation            Voltage(V)        Temp(℃)              410.125     456.125     469.625
                                                                    -30                  0.07        0.03        0.45
                                                                    -20                  0.33        0.58       0.71
                                                                    -10                  0.58        0.85       0.21
                                                                     0                   0.14        0.66       0.58
                                                   12V              10                   0.78        0.11       0.62
           TM1              25KHz                                   20                   0.91        0.74       0.54
                                                                    30                   0.34        0.91       0.14
                                                                    40                   0.91        0.21       0.02
                                                                    50                   0.19        0.18       0.35
                                            6.29 (85% Rated)        20                   0.10       0.14        0.46
                                            8.51(115% Rated)        20                   0.78        0.71       0.63
                                Limit                                                        5.0 ppm
                             Test Results                                                     PASS
    Remark:
    1. Measured at TM1 to TM2, recorded worst case at TM1.




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                   Page 30 of 34


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                          FCC ID: 2AJTU-S6              Report No.: LCS190509078AEC



  5.7. Transmitter Frequency Behavior
   5.7.1 Test Applicable
    Section 90.214
    Transient frequencies must be within the maximum frequency difference limits during the time intervals
    indicated:
                                      Maximum frequency                                 All equipment
          Time intervals 1, 2
                                           difference 3               1500 to 174 MHz                 421 to 512 MHz
                       Transient Frequency Behavior for Equipment Designed to Operate on 25KHz Channels
      t1 4………………….....               ± 25.0KHz                    5.0ms                          10.0ms
      t2 ………………….......              ± 12.5KHz                    20.0ms                         25.0ms
      t3 4……………………..                 ± 25.0KHz                    5.0ms                          10.0ms
                      Transient Frequency Behavior for Equipment Designed to Operate on 12.5KHz Channels
      t1 4………………….....               ±12.5KHz                     5.0ms                          10.0ms
      t2 ………………….......              ± 6.25KHz                    20.0ms                         25.0ms
      t3 4……………………..                 ± 12.5KHz                    5.0ms                          10.0ms
                      Transient Frequency Behavior for Equipment Designed to Operate on 6.25KHz Channels
      t1 4………………….....               ±6.25KHz                     5.0ms                          10.0ms
      t2 ………………….......              ± 3.125KHz                   20.0ms                         25.0ms
      t3 4……………………..                 ± 6.25KHz                    5.0ms                          10.0ms
      1. ton is the instant when a 1 KHz test signal is completely suppressed, including any capture time due to phasing.
          t1 is the time period immediately following ton.
          t2 is the time period immediately following t1.
          t3 is the time period from the instant when the transmitter is turned off until toff.
          toff is the instant when 1 KHz test signal starts to rise.
      2. During the time from the end of t2 to the beginning of t3, the frequency difference must not exceed the limits
          specified in 90.213.
      3. Difference between the actual transmitter frequency and the assigned transmitter frequency.
      4. If the transmitter carrier output power rating is 6 watts or less, the frequency difference during this time period
          may exceed the maximum frequency for this time period.


   5.7.2 Test Configuration

                                                                 RF Communication
                PC
                                                                     Test Set




                                                                      Mini-Circuit
               EUT                     Attenuator(s)                                                     RF Detector
                                                                      Combiner




                                                                                                      Hewlett Packard
             Power                                                    Modulation
                                                                                                     Infinium Digitizing
             Supply                                                    Analyzer
                                                                                                        Oscilloscope


   5.7.3 Test Procedure
    According to TIA/EIA-603 2.2.19 requirement.




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                   Page 31 of 34


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                          FCC ID: 2AJTU-S6              Report No.: LCS190509078AEC



   5.7.4 Test Results

           Temperature                          24.5℃                         Humidity                        54.1%
           Test Engineer                       Scent Hu                      Test Voltage                 Normal Voltage

    Measured at TM1 to TM2, recorded worst case at TM1.
    Modulation Type: GMSK

                                               Transmitter Frequency Behavior




      25 KHz Channel Separation------Off – On                                 25 KHz Channel Separation------On – Off




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                   Page 32 of 34


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                             FCC ID: 2AJTU-S6              Report No.: LCS190509078AEC



6. LIST OF MEASURING EQUIPMENT

Item                Equipment                   Manufacturer           Model No.             Serial No.          Cal Date        Due Date
 1                 Power Meter                       R&S                 NRVS                 100444            2018-06-16      2019-06-15
 2                Power Sensor                       R&S                NRV-Z81               100458            2018-06-16      2019-06-15
 3                Power Sensor                       R&S                NRV-Z32                10057            2018-06-16      2019-06-15
 4        ESG Vector Signal Generator               Agilent             E4438C             MY49072627           2018-06-16      2019-06-15
 5            MXA Signal Analyzer                   Agilent             N9020A             MY50510140           2018-06-16      2019-06-15
 6              DC Power Supply                     Agilent             E3642A                  N/A             2018-11-15      2019-11-14
 7              EMI Test Software                 AUDIX                    E3                   N/A                 N/A             N/A
                                                   SIDT
 8        3m Semi Anechoic Chamber                                      SAC-3M              03CH03-HY           2018-06-16      2019-06-15
                                                FRANKONIA
 9            Positioning Controller                MF                  MF-7082                 N/A             2018-06-16      2019-06-15
 10            Active Loop Antenna            SCHWARZBECK            FMZB 1519B                00005            2018-07-26      2019-07-25
 11              By-log Antenna               SCHWARZBECK              VULB9163              9163-470           2018-07-26      2019-07-25
 12               Horn Antenna                SCHWARZBECK            BBHA 9120D            9120D-1925           2018-07-02      2019-07-01
 13         Broadband Horn Antenna            SCHWARZBECK             BBHA 9170                 791             2018-09-20      2019-09-19
 14          Broadband Preamplifier           SCHWARZBECK              BBV 9719              9719-025           2018-09-20      2019-09-19
 15             EMI Test Receiver                    R&S                 ESR 7                101181            2018-06-16      2019-06-15
 16       RS SPECTRUM ANALYZER                       R&S                 FSP40                100503            2018-11-15      2019-11-14
 17                AMPLIFIER                       QuieTek                QTK             CHM/0809065           2018-11-15      2019-11-14
 18              RF Cable-R03m                     Jye Bao              RG142                  CB021            2018-06-16      2019-06-15
                                                                      SUCOFLEX
 19              RF Cable-HIGH                    SUHNER                                    03CH03-HY           2018-06-16      2019-06-15
                                                                          106
 20               6dB Attenuator                       /               100W/6dB              1172040            2018-06-16      2019-06-15
 21               3dB Attenuator                       /                 2N-3dB                   /             2018-06-16      2019-06-15
 22             EMI Test Receiver                    R&S                  ESPI                101840            2018-06-16      2019-06-15
 23               Artificial Mains                   R&S                ENV216                101288            2018-06-16      2019-06-15
 24              10dB Attenuator              SCHWARZBECK            MTS-IMP-136        261115-001-0032         2018-06-16      2019-06-15
                                                                     SHWLPD2-52
 25                  Combiner                     eastsheep                                       /             2018-11-15      2019-11-14
                                                                        500S
                                                                                        1146.2003K02-10
 26               Audio Analyzer                     R&S                  UPV                                   2018-11-15      2019-11-14
                                                                                           1721-UW
 27          Storage Oscilloscope                 Tektronix            TDS3054B             B033154             2018-06-16      2019-06-15
          Digital Communication Test
 28                                                Aeroflex               3920                100245            2018-06-16      2019-06-15
                     Set
 29       RF Communication Test Set                   HP                 8920A             3813A10245           2018-06-16      2019-06-15
 30              Signal Generator                    R&S                 SMR40                 10016            2018-06-16      2019-06-15
 31              High-Pass Filter                   Anritsu             MP526B             6220875288           2018-06-16      2019-06-15
 32              High-Pass Filter                   Anritsu             MP526D             6220878442           2018-06-16      2019-06-15
Note: All equipment is calibrated through GUANGZHOU LISAI CALIBRATION AND TEST CO.,LTD.




      This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                      Page 33 of 34


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                          FCC ID: 2AJTU-S6              Report No.: LCS190509078AEC




7. TEST SETUP PHOTOGRAPHS OF EUT

    Please refer to separated files for Test Setup Photos of the EUT.



8. EXTERIOR PHOTOGRAPHS OF THE EUT

    Please refer to separated files for External Photos of the EUT.



9. INTERIOR PHOTOGRAPHS OF THE EUT

    Please refer to separated files for Internal Photos of the EUT.




                           ----------------THE END OF REPORT---------------




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                   Page 34 of 34



Document Created: 2019-07-11 14:25:43
Document Modified: 2019-07-11 14:25:43

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC