LCS190509078AEA_BT Classic

FCC ID: 2AJTU-S6

Test Report

Download: PDF
FCCID_4353388

SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                          FCC ID: 2AJTU-S6              Report No.: LCS190509078AEA




                                                 FCC TEST REPORT

                                                                For

                         South Surveying & Mapping Technology Co., Ltd.

                                                         Digital radio

                                                      Test Model: S6

                                  List Model No.: Please refer to page 6



Prepared for                             :    South Surveying & Mapping Technology Co., Ltd.
Address                                  :    No.39, Sicheng Road, Tianhe District, Guangzhou, China

Prepared by                              :    Shenzhen LCS Compliance Testing Laboratory Ltd.
Address                                  :    1/F., Xingyuan Industrial Park, Tongda Road, Bao'an Avenue, Bao'an
                                              District, Shenzhen, Guangdong, China
Tel                                      :    (+86)755-82591330
Fax                                      :    (+86)755-82591332
Web                                      :    www.LCS-cert.com
Mail                                     :    webmaster@LCS-cert.com

Date of receipt of test sample           :    May 28, 2019
Number of tested samples                 :    1
Serial number                            :    Prototype
Date of Test                             :    May 28, 2019~June 14, 2019
Date of Report                           :    June 20, 2019




  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 1 of 33


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                          FCC ID: 2AJTU-S6              Report No.: LCS190509078AEA



                                                FCC TEST REPORT
                                            FCC CFR 47 PART 15 C(15.247)

Report Reference No. ................. : LCS190509078AEA

Date of Issue .................................. : June 20, 2019

Testing Laboratory Name ............ : Shenzhen LCS Compliance Testing Laboratory Ltd.
Address .......................................... : 1/F., Xingyuan Industrial Park, Tongda Road, Bao'an Avenue,
                                                     Bao'an District, Shenzhen, Guangdong, China
Testing Location/ Procedure........... : Full application of Harmonised standards ■
                                         Partial application of Harmonised standards □
                                         Other standard testing method □
Applicant’s Name ......................... : South Surveying & Mapping Technology Co., Ltd.

Address .......................................... : No.39, Sicheng Road, Tianhe District, Guangzhou, China

Test Specification

Standard ......................................... : FCC CFR 47 PART 15 C(15.247)

Test Report Form No. ................... : LCSEMC-1.0

TRF Originator................................ : Shenzhen LCS Compliance Testing Laboratory Ltd.

Master TRF .................................... : Dated 2011-03
Shenzhen LCS Compliance Testing Laboratory Ltd. All rights reserved.
This publication may be reproduced in whole or in part for non-commercial purposes as long as the
Shenzhen LCS Compliance Testing Laboratory Ltd. is acknowledged as copyright owner and source of the
material. Shenzhen LCS Compliance Testing Laboratory Ltd. takes no responsibility for and will not
assume liability for damages resulting from the reader's interpretation of the reproduced material due to its
placement and context.
EUT Description. .......................... : Digital radio

Trade Mark ..................................... : SOUTH, KOLIDA, SANDING, RUIDE, TIANYU

Test Model...................................... : S6

Ratings ........................................... : DC 9-16V by external power

Result ........................................... : Positive

           Compiled by:                                    Supervised by:                                Approved by:




   Aking Jin/File administrator                    Leo Lee/Technique principal                      Gavin Liang/ Manager




  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 2 of 33


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                         FCC ID: 2AJTU-S6              Report No.: LCS190509078AEA



                                                      FCC -- TEST REPORT

                                                                                                 June 20, 2019
      Test Report No. :                            LCS190509078AEA
                                                                                                 Date of issue


   Test Model...............................        : S6

   EUT.........................................     : Digital radio


   Applicant...............................         : South Surveying & Mapping Technology Co., Ltd.
   Address..................................        : No.39, Sicheng Road, Tianhe District, Guangzhou, China
   Telephone...............................         :
   Fax..........................................    :


   Manufacturer........................             : Guangzhou South Satellite Navigation Instrument Co., Ltd.
   Address...................................       : Area A Layer 6, Area A Layer 5, Area A Layer 4, No.39, Sicheng
                                                      Road, Tianhe District, Guangzhou, China
   Telephone...............................         :
   Fax..........................................    :


   Factory...................................       : Guangzhou South Satellite Navigation Instrument Co., Ltd.
   Address...................................       : Area A Layer 6, Area A Layer 5, Area A Layer 4, No.39, Sicheng
                                                      Road, Tianhe District, Guangzhou, China
   Telephone...............................         :
   Fax..........................................    :




                              Test Result                                                        Positive
   The test report merely corresponds to the test sample.
   It is not permitted to copy extracts of these test result without the written permission of the test laboratory.




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                  Page 3 of 33


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                         FCC ID: 2AJTU-S6              Report No.: LCS190509078AEA


                                                         Revision History

           Revision                         Issue Date                         Revisions                        Revised By
              000                         June 20, 2019                       Initial Issue                     Gavin Liang




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                  Page 4 of 33


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                                                FCC ID: 2AJTU-S6                       Report No.: LCS190509078AEA



                                                               TABLE OF CONTENTS
   Description .................................................................................................................................. Page
   1. GENERAL INFORMATION ....................................................................................................................................6
      1.1. DESCRIPTION OF DEVICE (EUT) .........................................................................................................................6
      1.2. HOST SYSTEM CONFIGURATION LIST AND DETAILS ...........................................................................................6
      1.3. EXTERNAL I/O CABLE ..........................................................................................................................................7
      1.4. DESCRIPTION OF TEST FACILITY .........................................................................................................................7
      1.5. STATEMENT OF THE MEASUREMENT UNCERTAINTY ...........................................................................................7
      1.6. MEASUREMENT UNCERTAINTY ............................................................................................................................7
      1.7. DESCRIPTION OF TEST MODES ...........................................................................................................................8
   2. TEST METHODOLOGY ..........................................................................................................................................9
      2.1. EUT CONFIGURATION .........................................................................................................................................9
      2.2. EUT EXERCISE ....................................................................................................................................................9
      2.3. GENERAL TEST PROCEDURES ............................................................................................................................9
   3. SYSTEM TEST CONFIGURATION ....................................................................................................................10
      3.1. JUSTIFICATION ...................................................................................................................................................10
      3.2. EUT EXERCISE SOFTWARE ..............................................................................................................................10
      3.3. SPECIAL ACCESSORIES .....................................................................................................................................10
      3.4. BLOCK DIAGRAM/SCHEMATICS .........................................................................................................................10
      3.5. EQUIPMENT MODIFICATIONS .............................................................................................................................10
      3.6. TEST SETUP .......................................................................................................................................................10
   4. SUMMARY OF TEST RESULTS .........................................................................................................................11
   5. MEASUREMENT RESULTS ................................................................................................................................12
      5.1. PEAK POWER .....................................................................................................................................................12
      5.2. FREQUENCY SEPARATION AND 20 DB BANDWIDTH..........................................................................................13
      5.3. NUMBER OF HOPPING FREQUENCY ..................................................................................................................14
      5.4. TIME OF OCCUPANCY (DWELL TIME) ................................................................................................................15
      5.5. CONDUCTED SPURIOUS EMISSIONS AND BAND EDGES TEST..........................................................................16
      5.6. RESTRICTED BAND EMISSION LIMIT ..................................................................................................................17
      5.7. AC POWER LINE CONDUCTED EMISSIONS .........................................................................................................27
      5.8. RESTRICT-BAND BAND-EDGE MEASUREMENTS .................................................................................................28
      5.9. PSEUDORANDOM FREQUENCY HOPPING SEQUENCE ........................................................................................30
      5.10. ANTENNA REQUIREMENT ................................................................................................................................31
   6. SUMMARY OF TEST EQUIPMENT....................................................................................................................32
   7. TEST SETUP PHOTOGRAPHS OF EUT ..........................................................................................................33
   8. EXTERIOR PHOTOGRAPHS OF THE EUT .....................................................................................................33
   9. INTERIOR PHOTOGRAPHS OF THE EUT .......................................................................................................33




    This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                   Page 5 of 33


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                         FCC ID: 2AJTU-S6              Report No.: LCS190509078AEA


1. GENERAL INFORMATION
  1.1. Description of Device (EUT)
 Name of EUT                                      Digital radio
 Model No.                                        S6, S1, MDL, GDL20, N80, N80T, N80P
 Model Declaration                                PCB board, structure and internal of these model(s) are the same,
                                                  so no additional models were tested
 Test Model                                       S6
 Power Supply                                     DC 9-16V by external power
 Hardware version                                 Beaver7_35w_v1r2
 Software version                                 1.09.190524.RG60GL.CUS
 BT FCC Operation frequency                       2402-2480MHz
 BT FCC Modulation Type                           GFSK, π/4-DQPSK, 8-DPSK
 Bluetooth Version                                V3.0
 Antenna Type                                     Ceramic Antenna
 Antenna Gain                                     2.0dBi (max.) for Bluetooth
 WLAN FCC Operation frequency                     IEEE 802.11b/g/n HT20:2412-2462MHz
 WLAN FCC Modulation Type                         IEEE 802.11b: DSSS(CCK,DQPSK,DBPSK)
                                                  IEEE 802.11g/n: OFDM(64QAM, 16QAM, QPSK, BPSK)
 Antenna Type                                     Ceramic Antenna
 Antenna Gain                                     2.0dBi (max.) for WLAN
 PMR FCC Operation frequency                      410.125-469.625MHz
 Channel Separation                               0.5MHz
 Channel Number                                   120
 Channel Bandwidth                                25KHz
 Modulation Type                                  GMSK
 Emission Designator                              16K0G1D for GMSK Modulation at 25KHz Channel Separation
 Rate Power                                       30W/20W/10W
 Antenna Type                                     External Antenna
 Antenna Gain                                     5.0dBi (max.) for PMR
 Extreme temp. Tolerance                          -20°C to +55°C
 Extreme Voltage Tolerance                        DC 9V to 16V


  1.2. Host System Configuration List and Details

           Manufacturer                       Description                      Model               Serial Number         Certificate
               Lenovo                              PC                          B470                        --               DOC
               Lenovo                    AC/DC ADAPTER                    ADP-90DDB                        --               DOC




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                  Page 6 of 33


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                          FCC ID: 2AJTU-S6             Report No.: LCS190509078AEA



  1.3. External I/O Cable

            I/O Port Description                                Quantity                                      Cable
                Antenna Port                                         1                           RF Cable: 3.0m, shielded
        5-pin power cable socket                                     1                         Power Cable: 2.0m, shielded
          5-pin data cable socket                                    1                                         N/A


  1.4. Description of Test Facility
    FCC Registration Number is 254912.
    Industry Canada Registration Number is 9642A-1.
    EMSD Registration Number is ARCB0108.
    UL Registration Number is 100571-492.
    TUV SUD Registration Number is SCN1081.
    TUV RH Registration Number is UA 50296516-001.
    NVLAP Accreditation Code is 600167-0.
    FCC Designation Number is CN5024.
    CAB identifier is CN0071.

    The 3m-Semi anechoic test site fulfils CISPR 16-1-4 according to ANSI C63.4:2014 and CISPR
    16-1-4:2010 SVSWR requirement for radiated emission above 1GHz.

  1.5. Statement of the Measurement Uncertainty
    The data and results referenced in this document are true and accurate. The reader is cautioned that
    there may be errors within the calibration limits of the equipment and facilities. The measurement
    uncertainty was calculated for all measurements listed in this test report acc. To CISPR 16 – 4
    “Specification for radio disturbance and immunity measuring apparatus and methods – Part 4: Uncertainty
    in EMC Measurements” and is documented in the LCS quality system acc. To DIN EN ISO/IEC 17025.
    Furthermore, component and process variability of devices similar to that tested may result in additional
    deviation. The manufacturer has the sole responsibility of continued compliance of the device.

  1.6. Measurement Uncertainty
                     Test Item                       Frequency Range                      Uncertainty                Note
             Radiation Uncertainty           :         9KHz~30MHz                           ±3.10dB                   (1)
                                                      30MHz~200MHz                          ±2.96dB                   (1)
                                                    200MHz~1000MHz                          ±3.10dB                   (1)
                                                      1GHz~26.5GHz                          ±3.80dB                   (1)
                                                     26.5GHz~40GHz                          ±3.90dB                   (1)
            Conduction Uncertainty           :        150kHz~30MHz                          ±1.63dB                   (1)
               Power disturbance             :        30MHz~300MHz                          ±1.60dB                   (1)

    (1). This uncertainty represents an expanded uncertainty expressed at approximately the 95% confidence
    level using a coverage factor of k=2.




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                  Page 7 of 33


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                         FCC ID: 2AJTU-S6              Report No.: LCS190509078AEA



  1.7. Description of Test Modes
    Bluetooth operates in the unlicensed ISM Band at 2.4GHz. With basic data rate feature, the data rates can
    be up to 1 Mb/s by modulating the RF carrier using GFSK techniques. The EUT works in the X-axis,
    Y-axis, Z-axis. The following operating modes were applied for the related test items. All test modes were
    tested, only the result of the worst case was recorded in the report.

                                                           Frequency Range                       Data Rate
                      Mode of Operations
                                                                (MHz)                             (Mbps)
                                                                   2402                             1/2/3
                      BT V3.0(BDR/EDR)                             2441                             1/2/3
                                                                   2480                             1/2/3
                                                    For Conducted Emission
                                    Test Mode                                          TX Mode
                                                     For Radiated Emission
                                    Test Mode                                          TX Mode


    Worst-case mode and channel used for 150 KHz-30 MHz power line conducted emissions was the mode
    and channel with the highest output power that was determined to be TX (1Mbps).
    Worst-case mode and channel used for 9 KHz-1000 MHz radiated emissions was the mode and channel
    with the highest output power, that was determined to be TX(1Mbps-High Channel).




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                  Page 8 of 33


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                         FCC ID: 2AJTU-S6              Report No.: LCS190509078AEA



2. TEST METHODOLOGY
    The tests documented in this report were performed in accordance with ANSI C63.10-2013, FCC CFR
    PART 15C 15.207, 15.209, 15.247 and DA 00-705.

  2.1. EUT Configuration
    The EUT configuration for testing is installed on RF field strength measurement to meet the Commissions
    requirement and operating in a manner that intends to maximize its emission characteristics in a
    continuous normal application.

  2.2. EUT Exercise
    The EUT was operated in the normal operating mode for Hopping Numbers and Dwell Time test and a
    continuous transmits mode for other tests.
    According to its specifications, the EUT must comply with the requirements of the Section 15.207, 15.209,
    15.247 under the FCC Rules Part 15 Subpart C.

  2.3. General Test Procedures

   2.3.1 Conducted Emissions

    The EUT is directly placed on the ground. According to the requirements in Section 6.2.1 of ANSI
    C63.10-2013 Conducted emissions from the EUT measured in the frequency range between 0.15 MHz
    and 30MHz using Quasi-peak and average detector modes.

   2.3.2 Radiated Emissions

    The EUT is placed on a turntable, which is directly placed on the ground. The turntable shall rotate 360
    degrees to determine the position of maximum emission level. EUT is set 3m away from the receiving
    antenna, which varied from 1m to 4m to find out the highest emission. And also, each emission was to be
    maximized by changing the polarization of receiving antenna both horizontal and vertical. In order to find
    out the maximum emissions, exploratory radiated emission measurements were made according to the
    requirements in Section 6.3 of ANSI C63.10-2013




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                  Page 9 of 33


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                         FCC ID: 2AJTU-S6              Report No.: LCS190509078AEA



3. SYSTEM TEST CONFIGURATION
  3.1. Justification
    The system was configured for testing in a continuous transmits condition.

  3.2. EUT Exercise Software
    The system was configured for testing in a continuous transmits condition and change test channels by
    software (RF Test Tool) provided by application.

  3.3. Special Accessories
                                                                                                           shielded/
     No.        Equipment          Manufacturer          Model No.         Serial No.        Length                        Notes
                                                                                                          unshielded
      1          PC                    Lenovo            B470                    /              /              /            DOC
      2      Power adapter             Lenovo          ADP-90DDB                 /           1.00m        unshielded        DOC

  3.4. Block Diagram/Schematics
    Please refer to the related document

  3.5. Equipment Modifications
    Shenzhen LCS Compliance Testing Laboratory Ltd. has not done any modification on the EUT.

  3.6. Test Setup
    Please refer to the test setup photo.




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 10 of 33


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                          FCC ID: 2AJTU-S6              Report No.: LCS190509078AEA




4. SUMMARY OF TEST RESULTS

                                        Applied Standard: FCC Part 15 Subpart C
       FCC Rules                            Description of Test                                Result                    Remark
     §15.247(b)(1)              Maximum Conducted Output Power                               Compliant                Appendix A.1
       §15.247(c)                         Frequency Separation                               Compliant                Appendix A.3
       §15.247(c)                           20 dB Bandwidth                                  Compliant                Appendix A.2
    §15.247(a)(1)(ii)             Number of Hopping Frequency                                Compliant                Appendix A.4
   §15.247(a)(1)(iii)             Time Of Occupancy (Dwell Time)                             Compliant                Appendix A.5
                              Conducted Spurious Emissions and Band                                                   Appendix A.6
   §15.209, §15.205                                                                          Compliant
                                          Edges Test                                                                  Appendix A.7
        §15.209,
                                   Radiated Spurious Emissions                               Compliant                    Note 1
       §15.247(d)
         §15.205                   Emissions at Restricted Band                              Compliant                Appendix A.8
       §15.207(a)                    AC Conducted Emissions                                      N/A                      Note 3
         §15.203                         Antenna Requirements                                Compliant                    Note 1
   §15.247(i)§2.1091                            RF Exposure                                  Compliant                    Note 2

Remark:
1. Note 1 – Test results inside test report;
2. Note 2 – Test results in other test report (MPE report);
3. Note 3 – N/A Means not applicable.




    This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                  Page 11 of 33


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                         FCC ID: 2AJTU-S6              Report No.: LCS190509078AEA




5. MEASUREMENT RESULTS
  5.1. Peak Power
   5.1.1 Block Diagram of Test Setup




   5.1.2 Limit

    According to §15.247(b)(1), For frequency hopping systems operating in the 2400–2483.5 MHz band
    employing at least 75 non-overlapping hopping channels, and all frequency hopping systems in the
    5725–5850 MHz band: 1 watt. For all other frequency hopping systems in the 2400–2483.5 MHz band:
    0.125 watts.

   5.1.3 Test Procedure

    The transmitter output (antenna port) was connected to the spectrum analyzer. According to ANSI
    C63.10:2013 Output power test procedure for frequency-hopping spread-spectrum (FHSS) devices; this is
    an RF-conducted test to evaluate maximum peak output power. Use a direct connection between the
    antenna port of the unlicensed wireless device and the spectrum analyzer, through suitable attenuation.
    The hopping shall be disabled for this test:

    a) Use the following spectrum analyzer settings:
      1) Span: Approximately five times the 20 dB bandwidth, centered on a hopping channel.
      2) RBW > 20 dB bandwidth of the emission being measured.
      3) VBW ≥ RBW.
      4) Sweep: Auto.
      5) Detector function: Peak.
      6) Trace: Max hold.
    b) Allow trace to stabilize.
    c) Use the marker-to-peak function to set the marker to the peak of the emission.
    d) The indicated level is the peak output power, after any corrections for external attenuators and cables.

   5.1.4 Test Results

    PASS
    Please refer to Appendix A BT V3.0 (BDR/EDR) Test Data Section A.1
    Remark:
    1) Test results including cable loss;
    2) Measured at difference Packet Type for each mode and recorded worst case for each mode.




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 12 of 33


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                         FCC ID: 2AJTU-S6              Report No.: LCS190509078AEA



  5.2. Frequency Separation and 20 dB Bandwidth

   5.2.1 Limit

    According to §15.247(c) or A8.1(a), in any 100 kHz bandwidth outside the frequency bands in which the
    spread spectrum intentional radiator in operating, the radio frequency power that is produced by the
    intentional radiator shall be at least 20dB below that in the 100kHz bandwidth within the band that
    contains the highest level of the desired power, In addition, radiated emissions which fall in the restricted
    bands, as defined in §15.205(a), must also comply with the radiated emission limits specified in15.209(a).

   5.2.2 Block Diagram of Test Setup




   5.2.3 Test Procedure

    Frequency separation test procedure:
    1). Place the EUT on the table and set it in transmitting mode.
    2). Remove the antenna from the EUT and then connect a low loss RF cable from the antenna port to the
    Spectrum Analyzer.
    3). Set center frequency of Spectrum Analyzer = middle of hopping channel.
    4). Set the Spectrum Analyzer as RBW = 100 kHz, VBW = 300 kHz, Span = wide enough to capture the
    peaks of two adjacent channels, Sweep = auto.
    5). Max hold, mark 2 peaks of hopping channel and record the 2 peaks frequency.

    20dB bandwidth test procedure:
    1). Span = approximately 2 to 3 times the 20 dB bandwidth, centered on a hopping channel.
    2). RBW ≥1% of the 20 dB bandwidth, VBW ≥RBW.
    3). Detector function = peak.
    4). Trace = max hold.

   5.2.4 Test Results

    PASS
    Please refer to Appendix A BT V3.0 (BDR/EDR) Test Data Section A.2 for 20 dB bandwidth;
    Please refer to Appendix A BT V3.0 (BDR/EDR) Test Data Section A.3 for Frequency separation;
    Remark:
    1). Test results including cable loss;
    2). Measured at difference Packet Type for each mode and recorded worst case for each mode.




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 13 of 33


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                         FCC ID: 2AJTU-S6              Report No.: LCS190509078AEA



  5.3. Number of Hopping Frequency

   5.3.1 Limit

    According to §15.247(a)(1)(ii) or A8.1 (d), Frequency hopping systems operating in the band 2400-2483.5
    MHz shall use at least 15 hopping channels.

   5.3.2 Block Diagram of Test Setup




   5.3.3 Test Procedure

    1). Place the EUT on the table and set it in transmitting mode.
    2). Remove the antenna from the EUT and then connect a low loss RF cable from the antenna port to the
    Spectrum Analyzer.
    3). Set Spectrum Analyzer Start=2400MHz, Stop = 2483.5MHz, Sweep = auto.
    4). Set the Spectrum Analyzer as RBW/VBW=100 KHz/300KHz.
    5). Max hold, view and count how many channel in the band.

   5.3.4 Test Results

    PASS
    Please refer to Appendix A BT V3.0 (BDR/EDR) Test Data Section A.4
    Remark:
    1). Test results including cable loss;
    2). Measured at difference Packet Type for each mode and recorded worst case for each mode.




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 14 of 33


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                         FCC ID: 2AJTU-S6              Report No.: LCS190509078AEA



  5.4. Time of Occupancy (Dwell Time)
   5.4.1 Limit
    According to §15.247(a)(1)(iii) or A8.1 (d), Frequency hopping systems operating in the 2400MHz- 2483.5
    MHz bands. The average time of occupancy on any channels shall not greater than 0.4 s within a period
    0.4 s multiplied by the number of hopping channels employed.

   5.4.2 Block Diagram of Test Setup




   5.4.3 Test Procedure
    1). Place the EUT on the table and set it in transmitting mode.
    2). Remove the antenna from the EUT and then connect a low loss RF cable from the antenna port to the
    Spectrum Analyzer.
    3). Set center frequency of Spectrum Analyzer = operating frequency.
    4). Set the Spectrum Analyzer as RBW/VBW=1MHz/3MHz, Span = 0Hz, Sweep = auto.
    5). Repeat above procedures until all frequency measured was complete.

   5.4.4 Test Results
    PASS
    Please refer to Appendix A BT V3.0 (BDR/EDR) Test Data Section A.5
    Remark:
    1). Test results including cable loss;
    2). Measured at difference Packet Type for each mode and recorded worst case for each mode.
    3). The Dwell Time=Burst Width*Total Hops. The detailed calculations are showed as follows:
    The duration for dwell time calculation: 0.4[s]*hopping number=0.4[s]*79[ch]=31.6[s*ch];
    The burst width [ms/hop/ch], which is directly measured, refers to the duration on one channel hop.
    The hops per second for all channels: The selected EUT Conf uses a slot type of 5-Tx&1-Rx and a
    hopping rate of 1600 [ch*hop/s] for all channels. So the final hopping rate for all channels is
    1600/6=266.67 [ch*hop/s]
    The hops per second on one channel: 266.67 [ch*hops/s]/79 [ch]=3.38 [hop/s];
    The total hops for all channels within the dwell time calculation duration: 3.38 [hop/s]*31.6[s*ch]=106.67
    [hop*ch];
    The dwell time for all channels hopping: 106.67 [hop*ch]*Burst Width [ms/hop/ch].
    Dwell Time Calculate formula:
    DH1: Dwell time=Pulse time (ms) × (1600 ÷ 2 ÷ 79) ×31.6 Second
    DH3: Dwell time=Pulse time (ms) × (1600 ÷ 4 ÷ 79) ×31.6 Second
    DH5: Dwell time=Pulse Time (ms) × (1600 ÷ 6 ÷ 79) ×31.6 Second
    4). Measured at low, middle and high channel, recorded the worst case.
    5). Only reported DH5.
   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 15 of 33


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                         FCC ID: 2AJTU-S6              Report No.: LCS190509078AEA



  5.5. Conducted Spurious Emissions and Band Edges Test
   5.5.1 Limit

    In any 100 kHz bandwidth outside the frequency band in which the spread spectrum or digitally modulated
    intentional radiator is operating, the radio frequency power that is produced by the intentional radiator
    shall be at least 20 dB below that in the 100 kHz bandwidth within the band that contains the highest level
    of the desired power, based on either an RF conducted or a radiated measurement. Attenuation below the
    general limits specified in Section 15.209(a) is not required.

   5.5.2 Block Diagram of Test Setup




   5.5.3 Test Procedure

    Conducted RF measurements of the transmitter output were made to confirm that the EUT antenna port
    conducted emissions meet the specified limit and to identify any spurious signals that require further
    investigation or measurements on the radiated emissions site.
    The transmitter output is connected to the spectrum analyzer. The resolution bandwidth is set to 100 KHz.
    The video bandwidth is set to 300 KHz.
    Measurements are made over the 9 KHz to 26.5GHz range with the transmitter set to the lowest, middle,
    and highest channels

   5.5.4 Test Results of Conducted Spurious Emissions

    PASS
    Please refer to Appendix A BT V3.0 (BDR/EDR) Test Data Section A.6 for conducted spurious
    emission measurement.
    Please refer to Appendix A BT V3.0 (BDR/EDR) Test Data Section A.7 for conducted band edge
    measurement.
    Remark:
    1). Test results including cable loss;
    2). Measured at difference Packet Type for each mode and recorded worst case for each mode.
    3). “---“means that the fundamental frequency not for 15.209 limits requirement.
    4). Not recorded emission from 9 KHz to 30 MHz as emission level at least 20dBc lower than emission
    limit.




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 16 of 33


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                         FCC ID: 2AJTU-S6              Report No.: LCS190509078AEA



  5.6. Restricted Band Emission Limit
   5.6.1. Standard Applicable

    15.205 (a) Except as shown in paragraph (d) of this section, only spurious emissions are permitted in any
    of the frequency bands listed below:

                   MHz                       MHz                               MHz                      GHz
                0.090-0.110                  16.42-16.423                     399.9-410                4.5-5.15
                \1\ 0.495-0.505              16.69475-16.69525                608-614                  5.35-5.46
                2.1735-2.1905                16.80425-16.80475                960-1240                 7.25-7.75
                4.125-4.128                  25.5-25.67                       1300-1427                8.025-8.5
                4.17725-4.17775              37.5-38.25                       1435-1626.5              9.0-9.2
                4.20725-4.20775              73-74.6                          1645.5-1646.5            9.3-9.5
                6.215-6.218                  74.8-75.2                        1660-1710                10.6-12.7
                6.26775-6.26825              108-121.94                       1718.8-1722.2            13.25-13.4
                6.31175-6.31225              123-138                          2200-2300                14.47-14.5
                8.291-8.294                  149.9-150.05                     2310-2390                15.35-16.2
                8.362-8.366                  156.52475-156.52525              2483.5-2500               17.7-21.4
                8.37625-8.38675              156.7-156.9                      2690-2900                22.01-23.12
                8.41425-8.41475              162.0125-167.17                  3260-3267                23.6-24.0
                12.29-12.293.                167.72-173.2                     3332-3339                31.2-31.8
                12.51975-12.52025            240-285                          3345.8-3358              36.43-36.5
                12.57675-12.57725            322-335.4                        3600-4400                (\2\)
                13.36-13.41
    \1\ Until February 1, 1999, this restricted band shall be 0.490-0.510 MHz
    \2\ Above 38.6
    According to §15.247 (d): 20dBc in any 100 kHz bandwidth outside the operating frequency band. In case
    the emission fall within the restricted band specified on 15.205(a), then the 15.209(a) limit in the table
    below has to be followed.

                Frequencies                                Field Strength                        Measurement Distance
                   (MHz)                                 (microvolts/meter)                            (meters)
                0.009~0.490                                2400/F(KHz)                                   300
                0.490~1.705                                24000/F(KHz)                                   30
                1.705~30.0                                       30                                       30
                   30~88                                        100                                        3
                  88~216                                        150                                        3
                  216~960                                       200                                        3
                 Above 960                                      500                                        3

   5.6.2. Measuring Instruments and Setting

    Please refer to equipment list in this report. The following table is the setting of spectrum analyzer and
    receiver.
     Spectrum Parameter                              Setting
     Attenuation                                     Auto
     Start Frequency                                 1000 MHz
     Stop Frequency                                  10th carrier harmonic
     RB / VB (Emission in restricted band)           1MHz / 1MHz for Peak, 1 MHz / 1/B kHz for Average
     RB / VB (Emission in non-restricted band) 1MHz / 1MHz for Peak, 1 MHz / 1/B kHz for Average

    Receiver Parameter                                           Setting
    Attenuation                                                  Auto
    Start ~ Stop Frequency                                       9kHz~150kHz / RB/VB 200Hz/1KHz for QP/AVG
    Start ~ Stop Frequency                                       150kHz~30MHz / RB/VB 9kHz/30KHz for QP/AVG
    Start ~ Stop Frequency                                       30MHz~1000MHz / RB/VB 120kHz/1MHz for QP



   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 17 of 33


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                         FCC ID: 2AJTU-S6              Report No.: LCS190509078AEA



   5.6.3. Test Procedures

    1) Sequence of testing 9 kHz to 30 MHz

    Setup:
    --- The equipment was set up to simulate a typical usage like described in the user manual or described by
    manufacturer.
    --- If the EUT is a tabletop system, a rotatable table with 0.8 m height is used.
    --- If the EUT is a floor standing device, it is placed on the ground.
    --- Auxiliary equipment and cables were positioned to simulate normal operation conditions.
    --- The AC power port of the EUT (if available) is connected to a power outlet below the turntable.
    --- The measurement distance is 3 meter.
    --- The EUT was set into operation.

    Premeasurement:
    --- The turntable rotates from 0° to 315° using 45° steps.
    --- The antenna height is 0.8 meter.
    --- At each turntable position the analyzer sweeps with peak detection to find the maximum of all
    emissions

    Final measurement:
    --- Identified emissions during the premeasurement the software maximizes by rotating the turntable
    position (0° to 360°) and by rotating the elevation axes (0° to 360°).
    --- The final measurement will be done in the position (turntable and elevation) causing the highest
    emissions with QPK detector.
    --- The final levels, frequency, measuring time, bandwidth, turntable position, correction factor, margin to
    the limit and limit will be recorded. Also a plot with the graph of the premeasurement and the limit will be
    stored.




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 18 of 33


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                         FCC ID: 2AJTU-S6              Report No.: LCS190509078AEA



    2) Sequence of testing 30 MHz to 1 GHz

    Setup:
    --- The equipment was set up to simulate a typical usage like described in the user manual or described by
    manufacturer.
    --- If the EUT is a tabletop system, a table with 0.8 m height is used, which is placed on the ground plane.
    --- If the EUT is a floor standing device, it is placed on the ground plane with insulation between both.
    --- Auxiliary equipment and cables were positioned to simulate normal operation conditions
    --- The AC power port of the EUT (if available) is connected to a power outlet below the turntable.
    --- The measurement distance is 3 meter.
    --- The EUT was set into operation.

    Premeasurement:
    --- The turntable rotates from 0° to 315° using 45° steps.
    --- The antenna is polarized vertical and horizontal.
    --- The antenna height changes from 1 to 3 meter.
    --- At each turntable position, antenna polarization and height the analyzer sweeps three times in peak to
    find the maximum of all emissions.

    Final measurement:
    --- The final measurement will be performed with minimum the six highest peaks.
    --- According to the maximum antenna and turntable positions of premeasurement the software maximize
    the peaks by changing turntable position (± 45°) and antenna movement between 1 and 4 meter.
    --- The final measurement will be done with QP detector with an EMI receiver.
    --- The final levels, frequency, measuring time, bandwidth, antenna height, antenna polarization, turntable
    angle, correction factor, margin to the limit and limit will be recorded. Also a plot with the graph of the
    premeasurement with marked maximum final measurements and the limit will be stored.




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 19 of 33


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                         FCC ID: 2AJTU-S6              Report No.: LCS190509078AEA



    3) Sequence of testing 1 GHz to 18 GHz

    Setup:
    --- The equipment was set up to simulate a typical usage like described in the user manual or described by
    manufacturer.
    --- If the EUT is a tabletop system, a rotatable table with 1.5 m height is used.
    --- If the EUT is a floor standing device, it is placed on the ground plane with insulation between both.
    --- Auxiliary equipment and cables were positioned to simulate normal operation conditions
    --- The AC power port of the EUT (if available) is connected to a power outlet below the turntable.
    --- The measurement distance is 3 meter.
    --- The EUT was set into operation.

    Premeasurement:
    --- The turntable rotates from 0° to 315° using 45° steps.
    --- The antenna is polarized vertical and horizontal.
    --- The antenna height scan range is 1 meter to 2.5 meter.
    --- At each turntable position and antenna polarization the analyzer sweeps with peak detection to find the
    maximum of all emissions.

    Final measurement:
    --- The final measurement will be performed with minimum the six highest peaks.
    --- According to the maximum antenna and turntable positions of premeasurement the software maximize
    the peaks by changing turntable position (± 45°) and antenna movement between 1 and 4 meter. This
    procedure is repeated for both antenna polarizations.
    --- The final measurement will be done in the position (turntable, EUT-table and antenna polarization)
    causing the highest emissions with Peak and Average detector.
    --- The final levels, frequency, measuring time, bandwidth, turntable position, EUT-table position, antenna
    polarization, correction factor, margin to the limit and limit will be recorded. Also a plot with the graph of
    the premeasurement with marked maximum final measurements and the limit will be stored.




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 20 of 33


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                         FCC ID: 2AJTU-S6              Report No.: LCS190509078AEA



    4) Sequence of testing above 18 GHz

    Setup:
    --- The equipment was set up to simulate a typical usage like described in the user manual or described by
    manufacturer.
    --- If the EUT is a tabletop system, a rotatable table with 1.5 m height is used.
    --- If the EUT is a floor standing device, it is placed on the ground plane with insulation between both.
    --- Auxiliary equipment and cables were positioned to simulate normal operation conditions
    --- The AC power port of the EUT (if available) is connected to a power outlet below the turntable.
    --- The measurement distance is 1 meter.
    --- The EUT was set into operation.

    Premeasurement:
    --- The antenna is moved spherical over the EUT in different polarizations of the antenna.

    Final measurement:
    --- The final measurement will be performed at the position and antenna orientation for all detected
    emissions that were found during the premeasurements with Peak and Average detector.
    --- The final levels, frequency, measuring time, bandwidth, correction factor, margin to the limit and limit
    will be recorded. Also a plot with the graph of the premeasurement and the limit will be stored.




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 21 of 33


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                         FCC ID: 2AJTU-S6              Report No.: LCS190509078AEA



   5.6.4. Test Setup Layout




    Above 18 GHz shall be extrapolated to the specified distance using an extrapolation factor of 20
    dB/decade form 3m to 1m.
    Distance extrapolation factor = 20 log (specific distance [3m] / test distance [1.5m]) (dB);
    Limit line = specific limits (dBuV) + distance extrapolation factor [6 dB].

   5.6.5. EUT Operation during Test

    The EUT was programmed to be in continuously transmitting mode.




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 22 of 33


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                         FCC ID: 2AJTU-S6              Report No.: LCS190509078AEA



   5.6.6. Results of Radiated Emissions (9 KHz~30MHz)


              Temperature                       24.6℃                         Humidity                        53.1%
             Test Engineer                     Scent Hu                   Configurations                        BT

                Freq.                   Level                Over Limit               Over Limit
                                                                                                                Remark
               (MHz)                   (dBuV)                  (dB)                    (dBuV)
                   -                       -                        -                       -                  See Note


    Note:
    The amplitude of spurious emissions which are attenuated by more than 20 dB below the permissible
    value has no need to be reported.
    Distance extrapolation factor = 40 log (specific distance / test distance) (dB);
    Limit line = specific limits (dBuV) + distance extrapolation factor.

   5.6.7. Results of Radiated Emissions (Above 30MHz)

    PASS.
    Only record the worst test result in this report.
    The test data please refer to following page.

Below 1GHz

Horizontal




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 23 of 33


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                          FCC ID: 2AJTU-S6              Report No.: LCS190509078AEA


Vertical




     Note:
     1). Pre-scan all modes and recorded the worst case results in this report (BT 1Mbps (High Channel)).
     Emission level (dBuV/m) = 20 log Emission level (uV/m).
     2). Corrected Reading: Antenna Factor + Cable Loss + Read Level = Level.




    This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                  Page 24 of 33


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                         FCC ID: 2AJTU-S6              Report No.: LCS190509078AEA



    Above 1GHz

    The worst test result for GFSK, Channel 0 / 2402 MHz
                           Ant.   Pre.   Cab.
   Freq.    Reading                               Measured                       Limit         Margin
                           Fac    Fac     Los                                                                Remark            Pol.
   MHz        dBuV                                 dBuV/m                       dBuV/m          dB
                          dB/m     dB     dB
  4804.00     60.92      33.06 35.04     3.94       62.88                         74.00        -11.12        Peak          Horizontal
  4804.00     43.78      33.06 35.04     3.94       45.74                         54.00         -8.26       Average        Horizontal
  4804.00     58.86      33.06 35.04     3.94       60.82                         74.00        -13.18        Peak           Vertical
  4804.00     41.98      33.06 35.04     3.94       43.94                         54.00        -10.06       Average         Vertical

    The worst test result for GFSK, Channel 39 / 2441 MHz
                           Ant.   Pre.   Cab.
   Freq.    Reading                               Measured                       Limit         Margin
                           Fac    Fac     Los                                                                Remark            Pol.
   MHz        dBuV                                 dBuV/m                       dBuV/m          dB
                          dB/m     dB     dB
  4882.00     54.75       33.16 35.15 3.96          56.72                         74.00        -17.28        Peak          Horizontal
  4882.00     45.28       33.16 35.15 3.96          47.25                         54.00         -6.75       Average        Horizontal
  4882.00     58.47       33.16 35.15 3.96          60.44                         74.00        -13.56        Peak           Vertical
  4882.00     44.03       33.16 35.15 3.96          46.00                         54.00         -8.00       Average         Vertical

    The worst test result for GFSK, Channel 78 / 2480 MHz
                           Ant.   Pre.   Cab.
   Freq.    Reading                               Measured                       Limit         Margin
                           Fac    Fac     Los                                                                Remark            Pol.
   MHz        dBuV                                 dBuV/m                       dBuV/m          dB
                          dB/m     dB     dB
  4960.00     54.91      33.26 35.14     3.98       57.01                         74.00        -16.99        Peak          Horizontal
  4960.00     43.22      33.26 35.14     3.98       45.32                         54.00         -8.68       Average        Horizontal
  4960.00     57.97      33.26 35.14     3.98       60.07                         74.00        -13.93        Peak           Vertical
  4960.00     42.60      33.26 35.14     3.98       44.70                         54.00         -9.30       Average         Vertical

    The worst test result for π/4-DQPSK, Channel 0 / 2402 MHz
                           Ant.    Pre.   Cab.
   Freq.    Reading                              Measured     Limit                            Margin
                           Fac     Fac    Los                                                                Remark            Pol.
   MHz        dBuV                                dBuV/m     dBuV/m                             dB
                          dB/m      dB     dB
  4804.00     57.86      33.06 35.04      3.94      59.82     74.00                            -14.18        Peak          Horizontal
  4804.00     44.61      33.06 35.04      3.94      46.57     54.00                             -7.43       Average        Horizontal
  4804.00     58.78      33.06 35.04      3.94      60.74     74.00                            -13.26        Peak           Vertical
  4804.00     45.51      33.06 35.04      3.94      47.47     54.00                             -6.53       Average         Vertical

    The worst test result for π/4-DQPSK, Channel 39 / 2441 MHz
                           Ant.    Pre.   Cab.
   Freq.    Reading                              Measured      Limit                           Margin
                           Fac     Fac    Los                                                                Remark            Pol.
   MHz        dBuV                                dBuV/m     dBuV/m                             dB
                          dB/m      dB     dB
  4882.00     53.21       33.16 35.15 3.96         55.18      74.00                            -18.82        Peak          Horizontal
  4882.00     44.88       33.16 35.15 3.96         46.85      54.00                             -7.15       Average        Horizontal
  4882.00     57.82       33.16 35.15 3.96         59.79      74.00                            -14.21        Peak           Vertical
  4882.00     42.33       33.16 35.15 3.96         44.30      54.00                             -9.70       Average         Vertical

    The worst test result for π/4-DQPSK, Channel 78 / 2480 MHz
                           Ant.    Pre.   Cab.
   Freq.    Reading                              Measured      Limit                           Margin
                           Fac     Fac    Los                                                                Remark            Pol.
   MHz        dBuV                                dBuV/m     dBuV/m                             dB
                          dB/m      dB     dB
  4960.00     54.00      33.26 35.14      3.98     56.10      74.00                            -17.90        Peak          Horizontal
  4960.00     44.49      33.26 35.14      3.98     46.59      54.00                             -7.41       Average        Horizontal
  4960.00     60.51      33.26 35.14      3.98     62.61      74.00                            -11.39        Peak           Vertical
  4960.00     41.67      33.26 35.14      3.98     43.77      54.00                            -10.23       Average         Vertical




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 25 of 33


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                         FCC ID: 2AJTU-S6              Report No.: LCS190509078AEA



    The worst test result for 8DPSK, Channel 0 / 2402 MHz
                           Ant.   Pre.   Cab.
   Freq.    Reading                               Measured                       Limit         Margin
                           Fac    Fac     Los                                                                Remark            Pol.
   MHz        dBuV                                 dBuV/m                       dBuV/m          dB
                          dB/m     dB     dB
  4804.00     60.89      33.06 35.04     3.94       62.85                         74.00        -11.15        Peak          Horizontal
  4804.00     42.85      33.06 35.04     3.94       44.81                         54.00         -9.19       Average        Horizontal
  4804.00     56.45      33.06 35.04     3.94       58.41                         74.00        -15.59        Peak           Vertical
  4804.00     45.41      33.06 35.04     3.94       47.37                         54.00         -6.63       Average         Vertical

    The worst test result for 8DPSK, Channel 39 / 2441 MHz
                           Ant.   Pre.   Cab.
   Freq.    Reading                               Measured                       Limit         Margin
                           Fac    Fac     Los                                                                Remark            Pol.
   MHz        dBuV                                 dBuV/m                       dBuV/m          dB
                          dB/m     dB     dB
  4882.00     59.85       33.16 35.15 3.96          61.82                         74.00        -12.18        Peak          Horizontal
  4882.00     44.56       33.16 35.15 3.96          46.53                         54.00         -7.47       Average        Horizontal
  4882.00     54.89       33.16 35.15 3.96          56.86                         74.00        -17.14        Peak           Vertical
  4882.00     42.59       33.16 35.15 3.96          44.56                         54.00         -9.44       Average         Vertical

    The worst test result for 8DPSK, Channel 78 / 2480 MHz
                           Ant.   Pre.   Cab.
   Freq.    Reading                               Measured                       Limit         Margin
                           Fac    Fac     Los                                                                Remark            Pol.
   MHz        dBuV                                 dBuV/m                       dBuV/m          dB
                          dB/m     dB     dB
  4960.00     57.23      33.26 35.14     3.98       59.33                         74.00        -14.67        Peak          Horizontal
  4960.00     40.06      33.26 35.14     3.98       42.16                         54.00        -11.84       Average        Horizontal
  4960.00     60.88      33.26 35.14     3.98       62.98                         74.00        -11.02        Peak           Vertical
  4960.00     42.99      33.26 35.14     3.98       45.09                         54.00         -8.91       Average         Vertical
    Notes:
    1). Measuring frequencies from 9 KHz~10th harmonic (ex. 26GHz), No emission found between lowest
    internal used/generated frequency to 30 MHz.
    2). Radiated emissions measured in frequency range from 9 KHz~10th harmonic (ex. 26GHz) were made
    with an instrument using Peak detector mode.
    3). 18~25GHz at least have 20dB margin. No recording in the test report.




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 26 of 33


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                         FCC ID: 2AJTU-S6              Report No.: LCS190509078AEA



  5.7. AC Power line conducted emissions
   5.7.1 Standard Applicable

    According to §15.207 (a): For an intentional radiator which is designed to be connected to the public utility
    (AC) power line, the radio frequency voltage that is conducted back onto the AC power line on any
    frequency or frequencies within the band 150 kHz to 30 MHz shall not exceed 250 microvolts (The limit
    decreases linearly with the logarithm of the frequency in the range 0.15 MHz to 0.50 MHz). The limits at
    specific frequency range are listed as follows:

          Frequency Range                                                       Limits (dBμV)
                (MHz)                                      Quasi-peak                                      Average
             0.15 to 0.50                                   66 to 56                                       56 to 46
              0.50 to 5                                       56                                             46
               5 to 30                                        60                                             50

              * Decreasing linearly with the logarithm of the frequency

   5.7.2 Block Diagram of Test Setup




   5.7.3 Test Results

    Not applicable to this device.




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 27 of 33


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                         FCC ID: 2AJTU-S6              Report No.: LCS190509078AEA



  5.8. Restrict-band band-edge measurements

   5.8.1 Standard Applicable
   In any 100 kHz bandwidth outside the frequency band in which the spread spectrum or digitally modulated
   intentional radiator is operating, the radio frequency power that is produced by the intentional radiator shall
   be at least 20 dB below that in the 100 kHz bandwidth within the band that contains the highest level of the
   desired power, based on either an RF conducted or a radiated measurement, provided the transmitter
   demonstrates compliance with the peak conducted power limits. If the transmitter complies with the
   conducted power limits based on the use of RMS averaging over a time interval, as permitted under
   paragraph (b)(3) of this section, the attenuation required under this paragraph shall be 30 dB instead of 20
   dB. Attenuation below the general limits specified in §15.209(a) is not required. In addition, radiated
   emissions which fall in the restricted bands, as defined in §15.205(a), must also comply with the radiated
   emission limits specified in §15.209(a) (see §15.205(c)).

   5.8.2. Test Setup Layout




   5.8.3. Measuring Instruments and Setting

   Please refer to equipment list in this report. The following table is the setting of Spectrum Analyzer.

   5.8.4. Test Procedures
    According to KDB 412172 section 1.1 Field Strength Approach (linear terms):
    eirp = pt x gt = (E x d)2/30
    Where:
    pt = transmitter output power in watts, 
    gt = numeric gain of the transmitting antenna (unit less), 
    E = electric field strength in V/m, 
    d = measurement distance in meters (m).
    erp = eirp/1.64 = (E x d)2/(30 x 1.64)
    Where all terms are as previously defined.

   1). Check the calibration of the measuring instrument using either an internal calibrator or a known signal
   from an external generator.
   2). Remove the antenna from the EUT and then connect to a low loss RF cable from the antenna port to an
   EMI test receiver, then turn on the EUT and make it operate in transmitting mode. Then set it to Low
   Channel and High Channel within its operating range, and make sure the instrument is operated in its linear
   range.
   3). Set both RBW and VBW of spectrum analyzer to 100 kHz with a convenient frequency span including
   100kHz bandwidth from band edge, for Radiated emissions restricted band RBW=1MHz, VBW=3MHz for
   peak detector and RBW=1MHz, VBW=1/B for Peak detector.
   4). Measure the highest amplitude appearing on spectral display and set it as a reference level. Plot the
   graph with marking the highest point and edge frequency.
   5). Repeat above procedures until all measured frequencies were complete.
   6). Measure the conducted output power (in dBm) using the detector specified by the appropriate
   regulatory agency for guidance regarding measurement procedures for determining quasi-peak, peak, and
   average conducted output power, respectively).
   7). Add the maximum transmit antenna gain (in dBi) to the measured output power level to determine the
   EIRP level (see 12.2.5 for guidance on determining the applicable antenna gain)
   8). Add the appropriate maximum ground reflection factor to the EIRP level (6 dB for frequencies ≤ 30 MHz,
   4.7 dB for frequencies between 30 MHz and 1000 MHz, inclusive and 0 dB for frequencies > 1000 MHz).
   9). For devices with multiple antenna-ports, measure the power of each individual chain and sum the EIRP
   of all chains in linear terms (e.g., Watts, mW).
   10). Compare the resultant electric field strength level to the applicable regulatory limit.
   11). Perform radiated spurious emission test duress until all measured frequencies were complete.
   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 28 of 33


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                         FCC ID: 2AJTU-S6              Report No.: LCS190509078AEA



   5.8.5. Test Results


    PASS
    Please refer to Appendix A BT V3.0 (BDR/EDR) Test Data Section A.8.

    Remark:
    1). Test results including cable loss;
    2). Measured at difference Packet Type for each mode and recorded worst case for each mode.
    3). “---“means that the fundamental frequency not for 15.209 limits requirement.
    4). Measured at Hopping and Non-Hopping mode, recorded worst at Non-Hopping mode.
    5). The other emission levels were very low against the limit.
    6). The average measurement was not performed when the peak measured data under the limit of
    average detection.
    7). Detector AV is setting spectrum/receiver. RBW=1MHz/VBW=330Hz/Sweep time=Auto/Detector=Peak.
    8). Since the out-of-band characteristics of the EUT transmit antenna will often be unknown, the use of a
    conservative antenna gain value is necessary. Thus, when determining the EIRP based on the measured
    conducted power, the upper bound on antenna gain for a device with a single RF output shall be selected
    as the maximum in-band gain of the antenna across all operating bands, or 2 dBi, whichever is greater.
    However, for devices that operate in multiple frequency bands while using the same transmit antenna, the
    highest gain of the antenna within the operating band nearest in frequency to the restricted band emission
    being measured may be used in lieu of the overall highest gain when the emission is at a frequency that is
    within 20 percent of the nearest band edge frequency, but in no case shall a value less than 2 dBi be
    used.




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 29 of 33


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                          FCC ID: 2AJTU-S6              Report No.: LCS190509078AEA



   5.9. Pseudorandom frequency hopping sequence

   5.9.1 Standard Applicable
   For 47 CFR Part 15C sections 15.247 (a) (1) requirement:

   Frequency hopping systems shall have hopping channel carrier frequencies separated by a minimum of 25
   kHz or the 20 dB bandwidth of the hop-ping channel, whichever is greater. Alternatively, frequency hopping
   systems operating in the 2400–2483.5 MHz band may have hopping channel carrier frequencies that are
   separated by 25 kHz or two-thirds of the 20 dB bandwidth of the hopping channel, whichever is greater,
   provided the systems operate with an output power no greater than 125 mW. The system shall hop to
   channel frequencies that are selected at the system hopping rate from a pseudo randomly ordered list of
   hopping frequencies. Each frequency must be used equally on the average by each transmitter. The
   system receivers shall have input bandwidths that match the hop-ping channel bandwidths of their
   corresponding transmitters and shall shift frequencies in synchronization with the transmitted signals.

   5.9.2 EUT Pseudorandom Frequency Hopping Sequence Requirement

  The pseudorandom frequency hopping sequence may be generated in a nice-stage shift register whose
  5th first stage. The sequence begins with the first one of 9 consecutive ones, for example: the shift register
  is initialized with nine ones.
● Number of shift register stages:9
● Length of pseudo-random sequence:29-1=511 bits
● Longest sequence of zeros:8(non-inverted signal)




   An example of pseudorandom frequency hopping sequence as follows:




    Each frequency used equally one the average by each transmitter.
   The system receiver have input bandwidths that match the hopping channel bandwidths of their
   corresponding transmitter and shift frequencies in synchronization with the transmitted signals.




    This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                  Page 30 of 33


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                         FCC ID: 2AJTU-S6              Report No.: LCS190509078AEA



  5.10. Antenna Requirement

   5.10.1 Standard Applicable

    According to antenna requirement of §15.203.
    An intentional radiator shall be designed to ensure that no antenna other than that furnished by the
    responsible party shall be used with the device. The use of a permanently attached antenna or of an
    antenna that uses a unique coupling to the intentional radiator shall be considered sufficient to comply
    with the provisions of this Section. The manufacturer may design the unit so that a broken antenna can be
    re-placed by the user, but the use of a standard antenna jack or electrical connector is prohibited. This
    requirement does not apply to carrier current devices or to devices operated under the provisions of
    Sections 15.211, 15.213, 15.217, 15.219, or 15.221. Further, this requirement does not apply to
    intentional radiators that must be professionally installed, such as perimeter protection systems and some
    field disturbance sensors, or to other intentional radiators which, in accordance with Section 15.31(d),
    must be measured at the installation site. However, the installer shall be responsible for ensuring that the
    proper antenna is employed so that the limits in this Part are not exceeded.
    And according to §15.247(4)(1), system operating in the 2400-2483.5MHz bands that are used
    exclusively for fixed, point-to-point operations may employ transmitting antennas with directional gain
    greater than 6dBi provided the maximum peak output power of the intentional radiator is reduced by 1 dB
    for every 3 dB that the directional gain of the antenna exceeds 6dBi.

   5.10.2 Antenna Connected Construction
   5.10.2.1. Standard Applicable

    According to § 15.203 & RSS-Gen, an intentional radiator shall be designed to ensure that no antenna
    other than that furnished by the responsible party shall be used with the device.

   5.10.2.2. Antenna Connector Construction

    The gain of antenna used for transmitting is 2.0dBi, and the antenna is a Ceramic antenna and no
    consideration of replacement. Please see EUT photo for details.

   5.10.2.3. Results: Compliance.




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 31 of 33


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                             FCC ID: 2AJTU-S6                Report No.: LCS190509078AEA




6. SUMMARY OF TEST EQUIPMENT
 Item                 Equipment                   Manufacturer          Model No.              Serial No.          Cal Date       Due Date
  1                  Power Meter                       R&S                 NRVS                 100444            2018‐06‐16     2019‐06‐15
  2                  Power Sensor                      R&S               NRV‐Z81                100458            2018‐06‐16     2019‐06‐15
  3                  Power Sensor                      R&S               NRV‐Z32                10057             2018‐06‐16     2019‐06‐15
  4                  Test Software                  Tonscend             JS1120‐2                N/A                 N/A             N/A
  5                 RF Control Unit                 Tonscend             JS0806‐2                N/A              2018‐06‐16     2019‐06‐15
  6              MXA Signal Analyzer                  Agilent             N9020A             MY50510140           2018‐06‐16     2019‐06‐15
  7                DC Power Supply                    Agilent             E3642A                 N/A              2018‐11‐15     2019‐11‐14
  8               EMI Test Software                   AUDIX                  E3                  N/A              2018‐06‐16     2019‐06‐15
  9           3m Semi Anechoic Chamber           SIDT FRANKONIA           SAC‐3M              03CH03‐HY           2018‐06‐16     2019‐06‐15
  10             Positioning Controller                 MF               MF‐7082                 N/A              2018‐06‐16     2019‐06‐15
  11             Active Loop Antenna             SCHWARZBECK           FMZB 1519B               00005             2018‐07‐26     2019‐07‐25
  12                By‐log Antenna               SCHWARZBECK             VULB9163              9163‐470           2018‐07‐26     2019‐07‐25
  13                 Horn Antenna                SCHWARZBECK           BBHA 9120D            9120D‐1925           2018‐07‐02     2019‐07‐01
  14           Broadband Horn Antenna            SCHWARZBECK            BBHA 9170                 791             2018‐09‐20     2019‐09‐19
  15            Broadband Preamplifier           SCHWARZBECK             BBV 9719              9719‐025           2018‐09‐20     2019‐09‐19
  16               EMI Test Receiver                   R&S                 ESR 7                101181            2018‐06‐16     2019‐06‐15
  17           RS SPECTRUM ANALYZER                    R&S                 FSP40                100503            2018‐11‐15     2019‐11‐14
  18                  AMPLIFIER                      QuieTek                QTK             CHM/0809065           2018‐11‐15     2019‐11‐14
  19                RF Cable‐R03m                    Jye Bao              RG142                 CB021             2018‐06‐16     2019‐06‐15
  20                RF Cable‐HIGH                    SUHNER           SUCOFLEX 106            03CH03‐HY           2018‐06‐16     2019‐06‐15
  21                6dB Attenuator                       /              100W/6dB               1172040            2018‐06‐16     2019‐06‐15
  22                3dB Attenuator                       /                2N‐3dB                   /              2018‐06‐16     2019‐06‐15
  23               EMI Test Receiver                   R&S                  ESPI                101840            2018‐06‐16     2019‐06‐15
  24                Artificial Mains                   R&S                ENV216                101288            2018‐06‐16     2019‐06‐15
  25               10dB Attenuator               SCHWARZBECK           MTS‐IMP‐136        261115‐001‐0032         2018‐06‐16     2019‐06‐15
 Note: All equipment is calibrated through GUANGZHOU LISAI CALIBRATION AND TEST CO.,LTD.




       This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                     Page 32 of 33


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                         FCC ID: 2AJTU-S6              Report No.: LCS190509078AEA




7. TEST SETUP PHOTOGRAPHS OF EUT

    Please refer to separated files for Test Setup Photos of the EUT.


8. EXTERIOR PHOTOGRAPHS OF THE EUT

    Please refer to separated files for External Photos of the EUT.


9. INTERIOR PHOTOGRAPHS OF THE EUT

    Please refer to separated files for Internal Photos of the EUT.



                            ----------------THE END OF REPORT---------------




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 33 of 33



Document Created: 2019-07-11 14:24:32
Document Modified: 2019-07-11 14:24:32