Test Report

FCC ID: 2AJRQME105P

Test Report

Download: PDF
FCCID_3587606

FCC RADIO TEST REPORT
 FCC ID: 2AJRQME105P

          Product: Wireless Charger
      Trade Name: Maxeye
     Model Name: ME105P
     Serial Model: ME105A, ME105B, ME105C,
                   ME105D
       Report No.: POCE17091932BRF



                   Prepared for
          Maxeye Smart Technologies Co., Ltd.

    Room 6008, Chuangxingda Buiding, Xinan, Baoan,
                  Shenzhen, China




                    Prepared by


         Shenzhen POCE Technology Co.,Ltd.
Room 502, Bldg. 1, Xinghua Garden, Baoan Road Xixiang,
            Baoan District,Shenzhen, China


                                                 Page 2 of 22                  Report No.: POCE17091932BRF



                                         TEST RESULT CERTIFICATION

Applicant’s name ................. : Maxeye Smart Technologies Co., Ltd.
Address ................................. : Room 6008, Chuangxingda Buiding, Xinan, Baoan,
                                            Shenzhen, China
Manufacture's Name............ : Maxeye Smart Technologies Co., Ltd.
Address ................................. : Room 6008, Chuangxingda Buiding, Xinan, Baoan,
                                            Shenzhen, China
Product description
Product name ........................... : Wireless Charger
Model and/or type reference : ME105P, ME105A, ME105B, ME105C, ME105D
Standards ............................. : 15.209

Test procedure ..............................   ANSI C63.4: 2014
This device described above has been tested by POCE, and the test results show that the
equipment under test (EUT) is in compliance with the FCC requirements. And it is applicable
only to the tested sample identified in the report.
This report shall not be reproduced except in full, without the written approval of POCE, this document
may be altered or revised by POCE, personal only, and shall be noted in the revision of
the document.
Date of Test ............................................ :
Date (s) of performance of tests ............. : 3 Jul. 2017 ~11 Jul. 2017
Date of Issue ........................................... : 11 Jul. 2017
Test Result ............................................... : Pass




                          Testing Engineer              :

                                                                           (Jerry Lin)


                          Technical Manager :

                                                                       (Jimmy Yao)


                          Authorized Signatory :

                                                                       (Terry Yang)


                           Page 3 of 22       Report No.: POCE17091932BRF




                        Table of Contents                          Page


1 . TEST SUMMARY                                                       4
  1.1 TEST FACILITY                                                    5
  1.2 MEASUREMENT UNCERTAINTY                                          5
2 . GENERAL INFORMATION                                                6
  2.1 GENERAL DESCRIPTION OF EUT                                       6
  2.2 DESCRIPTION OF TEST MODES                                        7
  2.3 DESCRIPTION OF TEST SETUP                                        8
  2.4 DESCRIPTION TEST PERIPHERAL AND EUT PERIPHERAL                   9
  2.5 MEASUREMENT INSTRUMENTS LIST                                    10
3 . EMC EMISSION TEST                                                11
  3.1 CONDUCTED EMISSION MEASUREMENT                                  11
     3.1.1 POWER LINE CONDUCTED EMISSION                              11
     3.1.2 TEST PROCEDURE                                             12
     3.1.3 TEST SETUP                                                 12
     3.1.4 EUT OPERATING CONDITIONS                                   12
     3.1.5 TEST RESULTS                                               13
  3.2 RADIATED EMISSION MEASUREMENT                                   15
     3.2.1 LIMITS OF RADIATED EMISSION MEASUREMENT                    15
     3.2.2 TEST PROCEDURE                                             15
     3.2.3 TEST SETUP                                                 17
     3.2.4 EUT OPERATING CONDITIONS                                   17
     3.2.5 TEST RESULTS(Blow 30MHZ)                                   19
     3.2.6 TEST RESULTS( 30MHZ-1GHZ)                                  20
4 . ANTENNA REQUIREMENT                                              22
  4.1 STANDARD REQUIREMENT                                            22
  4.2 EUT ANTENNA                                                     22


                                 Page 4 of 22           Report No.: POCE17091932BRF


1. TEST SUMMARY

Test procedures according to the technical standards:
                                        EMC Emission

         Standard                     Test Item            Limit     Judgment   Remark

      FCC Part 15.207            Conducted Emission      Class B       PASS
      FCC Part 15.209
                                  Radiated Emission      Class B       PASS

          15.203                Antenna Requirement         --         PASS


                                 Page 5 of 22              Report No.: POCE17091932BRF


1.1 TEST FACILITY
   Shenzhen POCE Technology Co.,Ltd.
  Add. : Room 502, Bldg. 1, Xinghua Garden, Baoan Road Xixiang, Baoan District, Shenzhen,
   China
   FCC Registered No.: 222278
1.2 MEASUREMENT UNCERTAINTY
  The reported uncertainty of measurement y ± U,where expended uncertainty U is based on a
  standard uncertainty multiplied by a coverage factor of k=2,providing a level of confidence of
  approximately 95 %。

  A. Conducted Measurement :

      Test Site   Method     Measurement Frequency Range         U,(dB)         NOTE
      POCE01       ANSI           150 KHz ~ 30MHz                 3.2

  B. Radiated Measurement :

      Test Site   Method     Measurement Frequency Range         U,(dB)         NOTE
      POCE01       ANSI           30MHz ~ 1000MHz                 4.7
                                    1GHz ~6GHz                    5.0


                         Page 6 of 22              Report No.: POCE17091932BRF


2. GENERAL INFORMATION

2.1 GENERAL DESCRIPTION OF EUT

  Equipment              Wireless Charger
  Brand Name             Maxeye
  Model Name.            ME105P
  Serial No              ME105A, ME105B, ME105C, ME105D
                         All the model are the same circuit and RF module,
  Model Difference
                         except model names.
  Power Supply           DC 5V from USB port
  Operation frequency    110-205KHz
  Antenna Type           Loop antenna


                            Page 7 of 22                 Report No.: POCE17091932BRF


2.2 DESCRIPTION OF TEST MODES

  To investigate the maximum EMI emission characteristics generates from EUT, the
  test system was pre-scanning tested base on the consideration of following EUT
  operation mode or test configuration mode which possible have effect on EMI
  emission level. Each of these EUT operation mode(s) or test configuration mode(s)
  mentioned above was evaluated respectively.


           Pretest Mode                        Description
              Mode 1                          Charging Mode


                                 For Conducted Test
          Final Test Mode                      Description
              Mode 1                          Charging Mode


                                  For Radiated Test
          Final Test Mode                      Description
              Mode 1                          Charging Mode


                         Page 8 of 22   Report No.: POCE17091932BRF


2.3 DESCRIPTION OF TEST SETUP




                 E1        E2


                                 Page 9 of 22               Report No.: POCE17091932BRF


2.4 DESCRIPTION TEST PERIPHERAL AND EUT PERIPHERAL

The EUT has been tested as an independent unit together with other necessary accessories or
support units. The following support units or accessories were used to form a representative test
configuration during the tests.

Item       Equipment         Mfr/Brand      Model/Type No.             Series No.         Note

 E-1 Wireless Charger          Maxeye           ME105P           ME105A, ME105B,          EUT
                                                                 ME105C, ME105D
 E-2      GALAXY S7        SAMSUNG              G9350            N/A




Item      Shielded Type     Ferrite Core        Length                      Note




 Note:
  (1)    The support equipment was authorized by Declaration of Confirmation.
  (2)    For detachable type I/O cable should be specified the length in cm in『Length』column.


                                   Page 10 of 22                 Report No.: POCE17091932BRF


2.5 MEASUREMENT INSTRUMENTS LIST

Radiation Test equipment
         Kind of                                                    Last       Calibrated   Calibratio
Item                Manufacturer     Type No.      Serial No.
       Equipment                                                 calibration      until     n period
 1     Spectrum         Agilent       E4407B       MY4510804 2016.09.06 2017.09.05           1 year
       Analyzer                                        0
 2    Test Receiver      R&S           ESPI          101318      2016.09.07 2017.09.06       1 year
 3    Bilog Antenna     TESEQ        CBL6111D        31216       2016.09.06 2017.09.05       1 year
 4    50Ω Coaxial    Anritsu  MP59B    620026441 2016.09.07 2017.09.06                       1 year
         Switch                             6
       Spectrum
 5                 ADVANTEST   R3132   150900201 2016.09.07 2017.09.06                       1 year
        Analyzer
 6    Horn Antenna    EM     EM-AH-101 2011071402 2016.09.06 2017.09.05                      1 year
                                         80
 7      Horn Ant      Schwarzbeck BBHA 9170         9170-181     2016.09.06 2017.09.05       1 year
 8      Amplifier        EM          EM-30180        060538      2016.12.22 2017.12.21       1 year
 9    Loop Antenna       ARA        PLA-1030/B        1029       2016.09.08 2017.09.07       1 year
 10   Power Meter        R&S           NRVS          100696      2016.09.06 2017.09.05       1 year
 11      Power           R&S         URV5-Z4       0395.1619. 2016.09.06 2017.09.05          1 year
         Sensor                                        05

Conduction Test equipment
         Kind of      Manufactu                                     Last       Calibrated Calibration
Item                                 Type No.       Serial No.
       Equipment         rer                                     calibration     until     period
 1     Test Receiver      R&S          ESCI          101160      2016.09.06 2017.09.05       1 year
 2        LISN            R&S         ENV216         101313      2016.08.24 2017.08.23       1 year
 3        LISN           EMCO         3816/2       00042990      2016.08.24 2017.08.23       1 year
       50Ω Coaxial
 4                       Anritsu      MP59B        6200264417 2016.09.07 2017.09.06          1 year
         Switch
 5    Passive Voltage
                          R&S        ESH2-Z3         100196      2016.09.07 2017.09.06       1 year
          Probe
 6    Absorbing clamp     R&S         MOS-21         100423      2016.09.08 2017.09.07       1 year


                                    Page 11 of 22                Report No.: POCE17091932BRF



3. EMC EMISSION TEST

3.1 CONDUCTED EMISSION MEASUREMENT

3.1.1 POWER LINE CONDUCTED EMISSION (Frequency Range 150KHz-30MHz)


                                                             Class B (dBuV)
        FREQUENCY (MHz)
                                              Quasi-peak                  Average
              0.15 -0.5                          66 - 56 *                    56 - 46 *
              0.50 -5.0                              56.00                     46.00
              5.0 -30.0                              60.00                     50.00
       Note:
         (1) The tighter limit applies at the band edges.
         (2) The limit of " * " marked band means the limitation decreases linearly with the
             logarithm of the frequency in the range.


The following table is the setting of the receiver
               Receiver Parameters                                      Setting
                    Attenuation                                          10 dB
                 Start Frequency                                       0.15 MHz
                 Stop Frequency                                         30 MHz
                   IF Bandwidth                                          9 kHz


                                  Page 12 of 22               Report No.: POCE17091932BRF


3.1.2 TEST PROCEDURE
 a. The EUT was placed 0.4 meters from the horizontal ground plane with EUT being
    connected to the power mains through a line impedance stabilization network (LISN). All
    other support equipments powered from additional LISN(s). The LISN provide 50 Ohm/
    50uH of coupling impedance for the measuring instrument.
 b. Interconnecting cables that hang closer than 40 cm to the ground plane shall be folded
    back and forth in the center forming a bundle 30 to 40 cm long.
 c. I/O cables that are not connected to a peripheral shall be bundled in the center. The end of
    the cable may be terminated, if required, using the correct terminating impedance. The
    overall length shall not exceed 1 m.
 d. LISN at least 80 cm from nearest part of EUT chassis.
 e. For the actual test configuration, please refer to the related Item –EUT Test Photos.


3.1.3 TEST SETUP




3.1.4 EUT OPERATING CONDITIONS
The EUT tested system was configured as the statements of 2.3 Unless otherwise a special
operating condition is specified in the follows during the testing.


                                   Page 13 of 22               Report No.: POCE17091932BRF


3.1.5 TEST RESULTS


 EUT:             Wireless Charger                  Model Name. :        ME105P
 Temperature:     26 ℃                              Relative Humidity: 54%
 Pressure:        1010hPa                           Phase :            L
 Test Voltage :   AC120V/60Hz                       Test Mode:         Charging




    Frequency      Meter Reading    Factor    Emission Level    Limits      Margin
                                                                                     Detector Type
      (MHz)           (dBμV)         (dB)          (dBμV)      (dBμV)        (dB)

        0.19           32.86         10.4          43.26        64.03       -20.77       QP

       0.194           21.54         10.41         31.95        53.86       -21.91       AVG

      0.6058           19.92         10.4          30.32         46         -15.68       AVG

      0.7378           33.61         10.41         44.02         56         -11.98       QP

      5.0579           30.91         10.67         41.58         60         -18.42       QP

      5.7458           15.89         10.67         26.56         50         -23.44       AVG

Remark:
1. All readings are Quasi-Peak and Average values.
2. Factor = Insertion Loss + Cable Loss.


                                   Page 14 of 22               Report No.: POCE17091932BRF



 EUT:              Wireless Charger                 Model Name. :       ME105P
 Temperature:      26 ℃                             Relative Humidity: 54%
 Pressure:         1010hPa                          Phase :            N
 Test Voltage :    AC120V/60Hz                      Test Mode:         Charging




    Frequency      Meter Reading    Factor    Emission Level   Limits      Margin
                                                                                    Detector Type
      (MHz)           (dBμV)          (dB)         (dBμV)      (dBμV)       (dB)

      0.2099           28.01         10.44         38.45        63.21      -24.76       QP

      0.2859           21.65         10.43         32.08        50.64      -18.56       AVG

       0.626           31.99         10.41          42.4         56        -13.6        QP

       0.626           21.76         10.41         32.17         46        -13.83       AVG

       3.322           15.15         10.53         25.68         46        -20.32       AVG

      3.5019           28.89          10.6         39.49         56        -16.51       QP


Remark:
1. All readings are Quasi-Peak and Average values.
2. Factor = Insertion Loss + Cable Loss.


                                     Page 15 of 22              Report No.: POCE17091932BRF


3.2 RADIATED EMISSION MEASUREMENT

3.2.1 RADIATED EMISSIONLIMITS(FREQUENCY RANGE 9KHZ-1000MHZ)
20dBc in any 100 kHz bandwidth outside the operating frequency band. In case the emission fall
within the restricted band specified on 15.205(a), then the 15.209(a) limit in the table below has
to be followed.(unintentional radiator)
          Frequencies                  Field Strength        Measurement Distance
            (MHz)                     (micorvolts/meter)              (meters)
        0.009~0.490                     2400/F(KHz)                        300
        0.490~1.705                     24000/F(KHz)                       30
         1.705~30.0                           30                           30
            30~88                            100                            3
           88~216                            150                            3
          216~960                            200                            3
         Above 960                           500                            3

 The following table is the setting of the receiver
        Spectrum Parameter                                        Setting
             Attenuation                                            Auto
           Start Frequency                                       1000 MHz
           Stop Frequency                                   10th carrier harmonic
   RB / VB (emission in restricted
                                              1 MHz / 1 MHz for Peak, 1 MHz / 10Hz for Average
                band)

        Receiver Parameter                                        Setting
             Attenuation                                            Auto
       Start ~ Stop Frequency                          9kHz~150kHz / RB 200Hz for QP
       Start ~ Stop Frequency                          150kHz~30MHz / RB 9kHz for QP
       Start ~ Stop Frequency                         30MHz~1000MHz / RB 120kHz for QP

3.2.2 TEST PROCEDURE
 a. The measuring distance of at 3 m shall be used for measurements at frequency up to 1GHz.
    For frequencies above 1GHz, any suitable measuring distance may be used.
 b. The EUT was placed on the top of a rotating table 0.8 meters above the ground at a 10 meter
    open area test site. The table was rotated 360 degrees to determine the position of the
    highest radiation.
 c. The height of the equipment or of the substitution antenna shall be 0.8 m; the height of the
    test antenna shall vary between 1 m to 4 m. Both horizontal and vertical polarizations of the
    antenna are set to make the measurement.
 d. The initial step in collecting conducted emission data is a spectrum analyzer peak detector
    mode pre-scanning the measurement frequency range. Significant peaks are then marked
    and then Quasi Peak detector mode re-measured, above 1G Average detector mode will be
    instead.


                               Page 16 of 24                 Report No.: POCE17091932BRF

 e. If the Peak Mode measured value compliance with and lower than Quasi Peak Mode Limit,
     the EUT shall be deemed to meet QP(AV) Limits and then no additional QP Mode
     measurement performed.
  f. For the actual test configuration, please refer to the related Item –EUT Test Photos.

3.2.3 DEVIATION FROM TEST STANDARD
No deviation


                              Page 17 of 22               Report No.: POCE17091932BRF


3.2.3 TEST SETUP

(A)Radiated Emission Test-Up Frequency Below 30MHz




(B) Radiated Emission Test Set-Up Frequency Below 1 GHz


                                Page 18 of 24                  Report No.: POCE17091932BRF

(C) Radiated Emission Test Set-Up Frequency Above 1GHz




3.2.4 EUT OPERATING CONDITIONS
The EUT tested system was configured as the statements of 2.3 Unless otherwise a special
operating condition is specified in the follows during the testing.


                               Page 19 of 22   Report No.: POCE17091932BRF


 3.2.5 TEST RESULTS(Blow 30MHZ)




Note: pp is Fundamental Field strength.


                                 Page 20 of 22                Report No.: POCE17091932BRF



3.2.6 TEST RESULTS( 30MHZ-1GHZ)


EUT:              Wireless Charger                  Model Name :       ME105P
Temperature:      20 ℃                              Relative Humidity: 48%
Pressure:         1010 hPa                          Test Voltage :     AC120V
Test Mode :       Charging                          Polarization :     Horizontal


  Frequency   Meter Reading     Factor    Emission Level     Limits       Margin
                                                                                     Detector Type
    (MHz)         (dBμV)         (dB)       (dBμV/m)        (dBμV/m)         (dB)

  199.2855        26.88          8.71            35.59        43.5           -7.91        QP

  331.3546        24.23         14.97            39.2         46             -6.8         QP

  394.8543        23.77         17.03            40.8         46             -5.2         QP

  531.9633        18.85         19.76            38.61        46             -7.39        QP

  793.3958        16.51         23.91            40.42        46             -5.58        QP



Remark:
1. Factor = Antenna Factor + Cable Loss – Pre-amplifier.


                                 Page 21 of 22                  Report No.: POCE17091932BRF



EUT:              Wireless Charger                  Model Name :        ME105P
Temperature:      20 ℃                              Relative Humidity: 48%
Pressure:         1010 hPa                          Test Voltage :     AC120V
Test Mode :       Charging                          Polarization :      Vertical


  Frequency   Meter Reading     Factor    Emission Level       Limits       Margin
                                                                                     Detector Type
    (MHz)         (dBμV)         (dB)       (dBμV/m)         (dBμV/m)        (dB)

  199.2855        30.12          8.71            38.83          43.5        -4.67         QP

  392.0951        25.41         16.93            42.34           46         -3.66         QP

  531.9633        20.35         19.76            40.11           46         -5.89         QP

  590.9737        14.71         20.79            35.5            46         -10.5         QP




Remark:
1. Factor = Antenna Factor + Cable Loss – Pre-amplifier.


                                  Page 22 of 22                Report No.: POCE17091932BRF



4. ANTENNA REQUIREMENT


4.1 STANDARD REQUIREMENT

   15.203 requirement: For intentional device, according to 15.203: an intentional radiator shall
   be designed to ensure that no antenna other than that furnished by the responsible party
   shall be used with the device.

4.2 EUT ANTENNA

The EUT antenna is a Loop Antenna. It comply with the standard requirement.

                                               Loop antenna


 Page 23 of 22        Report No.: POCE17091932BRF


RADIATED SPURIOUS EMISSION


Page 24 of 22        Report No.: POCE17091932BRF

CONDUCTED EMISSION TEST



Document Created: 2017-09-20 20:11:23
Document Modified: 2017-09-20 20:11:23

© 2024 FCC.report