I19Z60072-SEM01_SAR_Rev1_part4

FCC ID: 2AJOTTA-1156

RF Exposure Info

Download: PDF
FCCID_4198138

                                                                                                   t o      n   n   ~>   > —




Appendix (Additional assessments outside the scope of SCS 01 08)

Antenna Parameters with Head TSL

      Impedance, transformed to feed point                                           474 Q —7.4 jQ
      Return Loss                                                                       —21.9 dB



Antenna Parameters with Body TSL

      Impedance, transformed to feed point                                           44.1 Q — 4.9 jQ
      Return Loss                                                                      —21.8 dB




General Antenna Parameters and Design

      Electrical Delay (one direction)                                                  1.154 ns


After long term use with 100W radiated power, only a slight warming of the dipole near the feedpoint can be measured.

The dipole is made of standard semirigid coaxial cable. The center conductor of the feeding line is directly connected to the
second arm of the dipole. The antenna is therefore short—circuited for DC—signals. On some of the dipoles, small end caps
are added to the dipole arms in order to improve matching when loaded according to the position as explained in the
"Measurement Conditions" paragraph. The SAR data are not affected by this change. The overall dipole length is still
according to the Standard.
No excessive force must be applied to the dipole arms, because they might bend or the soldered connections near the
feedpoint may be damaged.


Additional EUT Data

      Manufactured by                                                                    SPEAG
      Manufactured on                                                               October 30, 2007




Certificate No: D2600V2—1012_Jul18                        Page 4 of 8


mm>                                                                       D ie e e
/7/
<                                                                               t   mt    n   n t   n   n = >




 DASY5 Validation Report for Head TSL

                                                                                         Date: 26.07.2018

 Test Laboratory: SPEAG, Zurich, Switzerland

 DUT: Dipole 2600 MHz; Type: D2600V2; Serial: D2600V2 — SN:1012

 Communication System: UID 0 — CW; Frequency: 2600 MHz
 Medium parameters used: f = 2600 MHz; 0 = 2.02 S/m; & = 37.2; p = 1000 kg/m*
 Phantom section: Flat Section
 Measurement Standard: DASYS (IEEE/IEC/ANSI C63.19—2011)

 DASY52 Configuration:

    e   Probe: EX3DV4 — SN7349; ConvF(7.7, 7.7, 7.7) @ 2600 MHz; Calibrated: 30.12.2017

    e    Sensor—Surface: 1.4mm (Mechanical Surface Detection)

    e    Electronics: DAE4 Sn601; Calibrated: 26.10.2017

    e    Phantom: Flat Phantom 5.0 (front); Type: QD 000 P50 AA; Serial: 1001

    *    DASY52 52.10.1(1476); SEMCAD X 14.6.11(7439)


 Dipole Calibration for Head Tissue/Pin=250 mW, d=10mm/Zoom Scan (7x7x7)/Cube 0:
 Measurement grid: dx=5mm, dy=5mm, dz=5mm
 Reference Value = 118.3 V/m; Power Drift = —0.04 dB
 Peak SAR (extrapolated) = 28.3 W/kg
 SAR(1 g) = 14.2 W/kg; SAR(10 g) = 6.33 W/kg
 Maximum value of SAR (measured) = 23.7 W/kg

        dB
        0

         —5.20

         —10.40

         —15.60

         —20.80

         —26.00
                    0 dB = 23.7 W/kg = 13.75 dBW/kg




 Certificate No: D2600V2—1012_Jul18              Page 5 of 8


Impedance Measurement Plot for Head TSL




File View         Channel Sweep         Calibration Trace Scale   Marker   System   Window   Help

                                                                                             2600000 GHz       47.371 Q
                                                                                                 8.2358 pF    —7.4326 Q
                                                                                          \, 2600000 GHz     80.734 mU
                                                                                                               ~105.12 °




              Ch1Avg= 20
     Ch1: Start 2.40000 GHz       ——                                                                         Stop 2.90000 GHz


                                                                                                             —2).859 dB




   35.00
     0       Ch         =
     Ch1: Start    2.40000 GHa    ———                                                                        Stop 2.20000 GHz

  Status      CH 1:         511                   C" 1—Port                Avg=20 Delay                           LCL




Certificate No: D2600V2—1012_Jul18                                  Page 6 of 8


DASY5 Validation Report for Body TSL

                                                                                   Date: 26.07.2018

Test Laboratory: SPEAG, Zurich, Switzerland

DUT: Dipole 2600 MHz; Type: D2600V2; Serial: D2600V2 — SN:1012

Communication System: UID 0 — CW; Frequency: 2600 MHz
Medium parameters used: f = 2600 MHz; 0 = 2.2 S/m; & = 51.5; p = 1000 kg/m3
Phantom section: Flat Section
Measurement Standard: DASYS (IEEE/IEC/ANSI C€63.19—2011)

DASY52 Configuration:

       Probe: EX3DV4 — SN7349; ConvF(7.81, 7.81, 7.81) @ 2600 MHz; Calibrated: 30.12.2017

        Sensor—Surface: 1.4mm (Mechanical Surface Detection)

        Electronics: DAE4 $n601; Calibrated: 26.10.2017

        Phantom: Flat Phantom 5.0 (back); Type: QD 000 P50 AA; Serial: 1002

        DASY52 52.10.1(1476); SEMCAD X 14.6.11(7439)


Dipole Calibration for Body Tissue/Pin=250 mW, d=10mm/Zoom Scan (7x7x7)/Cube 0:
Measurement grid: dx=5mm, dy=5mm, dz=5mm
Reference Value = 107.5 V/m; Power Drift = —0.07 dB
Peak SAR (extrapolated) = 27.7 W/kg
SAR(I g) = 13.7 W/kg; SAR(10 g) = 6.17 W/kg
Maximum value of SAR (measured) = 22.6 W/kg


       dB
        0

        —5.20

        ~10.40

        —15.60

        —20.80

        —26.00
                   0 dB = 22.6 W/kg = 13.54 dBW/kg




Certificate No: D2600V2—1012_Jul18             Page 7 of 8


(ISI,°
         Impedance Measurement Plot for Body TSL




          File         View    Channel    Sweep   Calibration    Trace    Scale   Marker   System   Window    Help

                                                                                                             2600000 GHz              44.132 O
                                                                                                                     12.374 pF       —4.9469 C
                                                                                                          y 2600000 GHz            81.418 mU
                                                                                                                                     —136.86 °




                           Ch1Avg= 20
                  Ch1: Start 2.40000 GHz       ——                                                                                  Stop 2.80000 GHz

                  00                                                                                                 000     GHz   —21.786 dB
                 00
            0.00




                  00       Ch1
                  Ch1: Start 2.                                                                                                    Stop 2.90000 GHz

            Status            CH 1:      E11                    | C" 1—Port                Avg=20 Delay                                 LCL




         Certificate No: D2600V2—1012_Jul18                                         Page 8 of 8


                                                               No.I19Z60072-SEM01
                                                                  Page 153 of 156


ANNEX I          Sensor Triggering Data Summary
1, Maximum transmit power reduce process follow below strategy when mobile connect network.
Headset               P-sensor         SAR sensor        TX Power reduce
Insert                     Near               Near                  Yes
Insert                     Near                Far                   No
Insert                      Far               Near                  Yes
Insert                      Far                Far                   No
Pull out                   Near               Near                   No
Pull out                   Near                Far                   No
Pull out                    Far               Near                  Yes
Pull out                    Far                Far                   No


2, Distance definition
         P-sensor Detect                  Near                       Far
     Distance Detected                    <3cm                     >=5cm


     SAR Sensor Detect                    Near                       Far
              black                     <=23mm                    >23mm
              front                     <=12mm                    >12mm
             bottom                     <=23mm                    >23mm
               top                      Not Detect               Not Detect
              right                     Not Detect               Not Detect
               left                     Not Detect               Not Detect


3, Reduction and Bands
                                  Maximum conduct
 Band         Requirement          power reduction
 DCS         1、2、3、4 Slots              3dB
 PCS         1、2、3、4 Slots              3dB
 WB1                                    2dB
LTE B1                                  2dB
LTE B3                                  2dB
LTE B7                                  2dB




                                                            ©Copyright. All rights reserved by CTTL.


                                                                                        No.I19Z60072-SEM01
                                                                                           Page 154 of 156

      According to the above description, this device was tested by the manufacturer to determine the
      SAR sensor triggering distances for the rear and bottom edge of the device. The measured power
      state within ±5mm of the triggering points (or until touching the phantom) is included for rear and
      each applicable edge.

      To ensure all production units are compliant it is necessary to test SAR at a distance 1mm less than
      the smallest distance from the device and SAR phantom with the device at maximum output power
      without power reduction.

      We tested the power and got the different proximity sensor triggering distances for rear and bottom
      edge. But the manufacturer has declared 23mm is the most conservative triggering distance for
      main antenna. So base on the most conservative triggering distance of 23mm, additional SAR
      measurements were required at 22mm from the highest SAR position between rear and bottom
      edge of main antenna.

      Rear
      Moving device toward the phantom:
                                                       The power state
Distance [mm]      28         27             26          25         24        23        22         21          20      19          18
Main antenna      Normal     Normal     Normal         Normal       Low       Low       Low        Low        Low      Low        Low


      Moving device away from the phantom:
                                                        The power state
 Distance [mm]      18       19         20        21       22       23        24          25             26           27          28
  Main antenna     Low       Low      Low         Low     Low       Low       Low       Normal      Normal          Normal       Normal


      Bottom Edge
      Moving device toward the phantom:
                                                         The power state
  Distance [mm]         28         27             26          25         24        23        22         21       20         19         18
   Main antenna     Normal     Normal         Normal     Normal      Normal     Low       Low        Low        Low        Low      Low

      Moving device away from the phantom:
                                                         The power state
  Distance [mm]      18       19         20        21         22     23        24             25          26           27           28
   Main antenna     Low       Low       Low        Low        Low    Low      Normal     Normal         Normal       Normal       Normal




                                                                                    ©Copyright. All rights reserved by CTTL.


                                                                    No.I19Z60072-SEM01
                                                                       Page 155 of 156

The influence of table tilt angles to proximity sensor triggering is determined by positioning each
edge that contains a transmitting antenna, perpendicular to the flat phantom, at the smallest sensor
triggering test distance by rotating the device around the edge next to the phantom in ≤ 10°
increments until the tablet is ±45°or more from the vertical position at 0°.




                              The rear evaluation for main antenna




                          The bottom edge evaluation for main antenna
Based on the above evaluation, we come to the conclusion that the sensor triggering is not released
and normal maximum output power is not restored within the ±45°range at the smallest sensor
triggering test distance declared by manufacturer.


                                                                 ©Copyright. All rights reserved by CTTL.


                                         No.I19Z60072-SEM01
                                            Page 156 of 156


ANNEX J   Accreditation Certificate