I18Z62361-IOT09_NFC FCC 15C_Report_Rev2

FCC ID: 2AJOTTA-1133

Test Report

Download: PDF
FCCID_4178155

                                  TEST REPORT
                              No. I18Z62361-IOT09
                                       for
                                            HMD Global OY

         Multi-band GSM/WCDMA/LTE phone with Bluetooth, WLAN

                      GSM 850,900,1800,1900 WCDMA: 1,2,4,5,8

        LTE: 1,2,3,4,5,7,8,12/17,28,38,66 mobile phone, Bluetooth 4.2,

                                           WIFI 802.11 b/g/n

                                      FCC ID: 2AJOTTA-1133
                                               with
                                  Hardware Version: 89571_1_12
                                  Software Version: 00XX_1_XXX
                                      Issued Date: 2019-02-14




Note:
The test results in this test report relate only to the devices specified in this report. This report shall not be
reproduced except in full without the written approval of CTTL.
The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST,
or any agency of the U.S. Government.
Test Laboratory:
CTTL, Telecommunication Technology Labs, CAICT
No. 52, Huayuan North Road, Haidian District, Beijing, P. R. China 100191.
Tel: +86(0)10-62304633-2512, Fax: +86(0)10-62304633-2504
Email: cttl_terminals@caict.ac.cn, website: www.caict.ac.cn


                                                                         ©Copyright. All rights reserved by CTTL.


REPORT HISTORY
Report Number     Revision   Description                Issue Date
I18Z62361-IOT09   Rev.0      1st edition                2019-01-30
I18Z62361-IOT09   Rev.1      2nd edition                2019-02-14




                                           ©Copyright. All rights reserved by CTTL.


                                                                                                         No. I18Z62361-IOT09
                                                                                                                 Page 3 of 24


CONTENTS
1.      0BTEST LABORATORY ......................................................................................................................... 4

     1.1.        BT
                8 ESTING LOCATION ............................................................................................................4
     1.2.     9BTESTING ENVIRONMENT ......................................................................................................4
     1.3.     PROJECT DATA ...................................................................................................................4
     1.4.     SIGNATURE ........................................................................................................................4

2.      1BCLIENT INFORMATION .................................................................................................................. 5

     2.1. APPLICANT INFORMATION....................................................................................................5
     2.2. MANUFACTURER INFORMATION .............................................................................................5

3.      2BEQUIPMENT UNDER TEST (EUT) AND ANCILLARY EQUIPMENT (AE) ............................ 6

     3.1.      14BABOUT EUT .......................................................................................................................6
     3.2.         15BINTERNAL IDENTIFICATION OF EUT USED DURING THE TEST .................................................6
     3.3.               16BINTERNAL IDENTIFICATION OF AE USED DURING THE TEST ....................................................6
     3.4.                  17BGENERAL DESCRIPTION ......................................................................................................7
     3.5.            18BEUT SET-UPS ....................................................................................................................7

4.      3BREFERENCE DOCUMENTS ............................................................................................................. 8

     4.1.      19BDOCUMENTS SUPPLIED BY THE APPLICANT ..........................................................................8
     4.2.         20BREGULATIONS AND STANDARDS ..........................................................................................8

5.      4BLABORATORY ENVIRONMENT .................................................................................................... 9

6.      5BSUMMARY OF TEST RESULTS .................................................................................................... 10

     6.1.      21BSUMMARY OF TEST RESULTS ............................................................................................10
     6.2.         2BTERMS USED IN THE SUMMARY OF TEST RESULTS .............................................................11
     6.3.           23BSTATEMENTS ...................................................................................................................11

7.      TEST EQUIPMENT UTILIZED ...................................................................................................... 12

ANNEX A: MEASUREMENT RESULTS ............................................................................................... 13

     24BA.1. ELECTRIC FIELD STRENGTH OF FUNDAMENTAL AND OUTSIDE THE ALLOCATED BANDS .............13
                    25BA.2. ELECTRIC FIELD RADIATED EMISSIONS (< 30MHZ) ................................................................15
        26BA.3. ELECTRIC FIELD RADIATED EMISSIONS (≥30MHZ) .................................................................17
                 27BA.4. FREQUENCY TOLERANCE .....................................................................................................19
           28BA.5. 20DB BANDWIDTH ................................................................................................................20
              29BA.6. CONDUCTED EMISSION .........................................................................................................22

ANNEX A: ACCREDITATION CERTIFICATE..................................................................................... 24




                                                                                                   ©Copyright. All rights reserved by CTTL.


                                                              No. I18Z62361-IOT09
                                                                      Page 4 of 24


1. Test Laboratory
       0B




1.1. Testing Location
            8B




CTTL (Huayuan North Road)
  Address:              No. 52, Huayuan North Road, Haidian District, Beijing,
                        P. R. China 100191
CTTL(Shouxiang)
  Address:              No. 51 Shouxiang Science Building, Xueyuan Road,
                        Haidian District, Beijing, P. R. China 100191



1.2. Testing Environment
            9B




  Normal Temperature:                 15-35℃
  Extreme Temperature:                -10/+55℃
  Relative Humidity:                  20-75%


1.3.             Project data
  Testing Start Date:                 2019-01-02
  Testing End Date:                   2019-01-18


1.4.             Signature




                      Zheng Mengxuan
                 (Prepared this test report)




                          Zhu Liang
                 ( Reviewedthis test report)




                          Gao Hong
                 (Approved this test report)




                                                          ©Copyright. All rights reserved by CTTL.


                                                                No. I18Z62361-IOT09
                                                                        Page 5 of 24




2. Client Information
       1B




2.1.  Applicant Information
  Company Name:       HMD Global OY
  Address:            Bertel Jungin aukio 9,02600 ESPOO,FINLAND
  Country:                  FINLAND
  Contact                   Rosario Casillo
  Tel:                      \
  Email:                    Rosario.Casillo@hmdglobal.com
2.2.        Manufacturer Information
  Company Name:             HMD Global OY
  Address:                  Bertel Jungin aukio 9,02600 ESPOO,FINLAND
  Country:                  FINLAND
  Contact                   Rosario Casillo
  Tel:                      \
  Email:                    Rosario.Casillo@hmdglobal.com




                                                            ©Copyright. All rights reserved by CTTL.


                                                                  No. I18Z62361-IOT09
                                                                          Page 6 of 24




3. Equipment Under Test (EUT) and Ancillary Equipment (AE)
    2B




3.1. About EUT
         14B




 Description:                            Multi-band GSM/WCDMA/LTE phone with Bluetooth,
                                         WLAN GSM 850,900, 1800,1900 WCDMA: 1,2,4,5,8
                                          LTE: 1,2,3,4,5,7,8,12/17,28,38,66 mobile phone,
                                                   Bluetooth 4.2, WIFI 802.11 b/g/n
 FCC ID                             2AJOTTA-1133
 With NFC Function:                 Yes
 Frequency:                         13.56 MHz
 Antenna:                           Internal
 Operation Voltage:                 3.5VDC to 4.4VDC (nominal: 3.9VDC)
 Operation Temperature:             -10°C to +55°C
Note1: Photographs of EUT are shown in ANNEX B of this test report. For component list, please
refer to documents of the manufacturer.



3.2. Internal Identification of EUT Used during the Test
         15B




Mobile phone identification
  EUT ID* IMEI                           HW Version          SW Version
  EUT3       352900100018964             89571_1_12          00XX_1_XXX
  EUT45      352900100018287             89571_1_12          00XX_1_XXX
 *EUT ID: is used to identify the test sample in the lab internally.

3.3. Internal Identification of AE Used during the Test
         16B




 AE ID*       Description                   SN                  Reversion
 AE1           Battery               /                          /
 AE2           Battery               /                          /
 AE3           Charger               /                          /
 AE5           USB Cable             /                          /
 AE6           USB Cable             /                          /
 AE8           PICC Card             /                          /
 AE9           Charger               /                          NO TEST
AE1
 Model                             WT330
 Manufacturer                      Jiade Energy Technology(Zhuhai) Co.,Ltd.
 Capacitance                       3000mAh
 Nominal voltage                   3.85V
AE2
 Model                             WT330
 Manufacturer                      Sunwoda Electronic Co.,Ltd

                                                              ©Copyright. All rights reserved by CTTL.


                                                                         No. I18Z62361-IOT09
                                                                                 Page 7 of 24

 Capacitance                          3000mAh
 Nominal voltage                      3.85V
AE3
 Model                                CH-35U
 Manufacturer                         Shenzhen Tianyin Electronics Co.,Ltd
 Length of cable                      /
AE5
 Model                                CB-35A
 Manufacturer                         Leagtech Electronics Co.,Ltd
 Length of cable                      /
AE6
 Model                                CB-35A
 Manufacturer                         Shenzhen BRL Technology Co.,Ltd.
 Length of cable                      /
AE8
 Model                                PICC Card
 Manufacturer                         /
 Length of cable                      /
AE9
 Model                                CH-35E
 Manufacturer                         Shenzhen Tianyin Electronics Co.,Ltd
 Length of cable                      /

*AE ID: is used to identify the test sample in the lab internally.

3.4. General Description
      17B




This is a product supporting Multi-band GSM/WCDMA/LTE phone with Bluetooth, WLAN GSM
850,900,1800,1900, WCDMA:1,2,4,5,8, LTE:1,2,3,4,5,7,8,12/17,28,38,66mobile phone, Bluetooth
4.2, WIFI 802.11 b/g/n
Manuals and specifications of the EUT were provided to fulfil the test.
Samples undergoing test were selected by the client.
Manufacturer's declaration: NFC work does not depend on other access methods, such as WLAN,
GPRS, etc.

3.5. EUT Set-ups
      18B




EUT Set-up No.                       Combination of EUT and AE                                     Remarks
                                                                                              30B49B




   Set. NFC01         EUT3 + AE1 + AE3+ AE5 + AE8                                                          --
   Set. NFC02         EUT 45                                                                               --
   Set. NFC03         EUT3 + AE8                                                                           --
The Transmit State of NFC: the NFC function is on. The EUT will transmit the NFC data and
command continuously during the test.
The Transmit State of without modulation: The EUT will transmit the CW signal at the operating         H




frequency.  H




                                                                     ©Copyright. All rights reserved by CTTL.


                                                                     No. I18Z62361-IOT09
                                                                             Page 8 of 24




4. Reference Documents
    3B




4.1. Documents Supplied by the Applicant
         19B




EUT feature information is supplied by the applicant or manufacturer, which is the basis of testing.



4.2. Regulations and Standards
         20B




The following documents listed in this section are referred for testing.
 Reference               Title                                                             Version
 CFR 47 Part 2           Part 2 — Frequency Allocations and Radio Treaty Matters;          2016
                         General Rules and Regulations.
 CFR 47 Part 15          Part 15 — Radio Frequency Devices.                                2016
                         Subpart C — Intentional Radiators.
                         H                                   H




                         § 15.35 Measurement detector functions and bandwidths.
                         § 15.207 Conducted limits.
                         § 15.209 Radiated emission limits, general requirements.
                         § 15.215 Additional provisions to the general radiated
                         emission limitations.
                         § 15.225 Operation within the band 13.110–14.010 MHz.
 ANSI C63.10             American National Standard of Procedures for Compliance           2013
                         Testing of Unlicensed Wireless Devices




                                                                 ©Copyright. All rights reserved by CTTL.


                                                                  No. I18Z62361-IOT09
                                                                          Page 9 of 24




5. LABORATORY ENVIRONMENT
    4B




Semi-anechoic chamber SAC-1 (23 meters×17meters×10meters)                did not exceed following
limits along the EMC testing:
Temperature                                   Min. = 15 ℃, Max. = 35 ℃
Relative humidity                             Min. = 15 %, Max. = 75 %
Shielding effectiveness                       0.014MHz - 1MHz, >60dB;
                                              1MHz - 1000MHz, >90dB.
Electrical insulation                         > 2 M
Ground system resistance                      < 4
Normalised site attenuation (NSA)             < ± 4 dB, 3m/10m distance,
                                              from 30 to 1000 MHz
Site voltage standing-wave ratio (SVSWR)      Between 0 and 6 dB, from 1GHz to 18GHz
Uniformity of field strength                  Between 0 and 6 dB, from 80 to 3000 MHz


Fully-Anechoic Chamber FAC-3 (8.6m×6.1m×3.85m) did not exceed following limits along the
testing:

Temperature                                   Min. = 15 ℃, Max. = 25 ℃

Relative humidity                             Min. = 30 %, Max. = 60 %
Shielding effectiveness                       > 110 dB
Electrical insulation                         > 2 M
Ground system resistance                      <1 
Site voltage standing-wave ratio (SVSWR)      Between 0 and 6 dB, from 1 to 18GHz
Uniformity of field strength                  Between 0 and 6 dB, from 80 to 4000 MHz


Conducted Chamber did not exceed following limits along the testing:

Temperature                                   Min. = 15 ℃, Max. = 25 ℃

Relative humidity                             Min. = 30 %, Max. = 60 %
Shielding effectiveness                       > 110 dB
Electrical insulation                         > 2 M
Ground system resistance                      < 0.5 

Control Room did not exceed following limits along the testing:

Temperature                                   Min. = 15 ℃, Max. = 25 ℃

Relative humidity                             Min. =30 %, Max. = 60 %
Shielding effectiveness                       > 110 dB
Electrical insulation                         > 2 M
Ground system resistance                      < 0.5 

                                                              ©Copyright. All rights reserved by CTTL.


                                                                           No. I18Z62361-IOT09
                                                                                  Page 10 of 24




6. SUMMARY OF TEST RESULTS
      5B




6.1. Summary of Test Results
           21B




                                                  Clause in            Section in
 No              Test Cases                                                                Verdict
                                                  Regulation           This Report
                 Electric Field Strength of
  1                                               CFR 47 § 15.225(a)                       P (Set. NFC03)
                 Fundamental Emissions
                                                                              A.1
                 Electric Field Strength of       CFR 47 § 15.225(b)
  2                                                                                        P (Set. NFC03)
                 Outside the Allocated Bands      CFR 47 § 15.225(c)
                 Electric Field Radiated          CFR 47 § 15.209             A.2          P (Set. NFC01)
  3
                 Emissions                        CFR 47 § 15.225(d)          A.3          P (Set. NFC01)
  4              Frequency Tolerance              CFR 47 § 15.225(e)          A.4          P (Set. NFC02)
  5              20dB Bandwidth                   CFR 47 § 15.215(c)          A.5          P (Set. NFC02)
  6              Conducted Emissions              CFR 47 § 15.207             A.6          P (Set. NFC01)
 The measurement is carried out according to ANSI C63.10. See ANNEX A for details.



Test Conditions:
For this report, all the test cases listed above were tested under normal Temperature, Voltage,
humidity, and Air Pressure. The specific conditions are as following:

                                              T min                       -20 ℃

 Temperature                                  T nom                       25 ℃

                                              T max                       55 ℃

                                              V min                       3.6 V
 Voltage                                      V nom                       3.8 V
                                              V max                       4.2 V
 Humidity                                     H nom                       44%
 Air Pressure                                 A nom                       1010 mbar




                                                                       ©Copyright. All rights reserved by CTTL.


                                                                     No. I18Z62361-IOT09
                                                                             Page 11 of 24

6.2. Terms Used in the Summary of Test Results
       2B




Terms Used in Condition Column:
 T nom           Normal Temperature
 T min           Low Temperature
 T max           High Temperature
 V nom           Normal Voltage
 V min           Low Voltage
 V max           High voltage
 H nom           Norm Humidity
 A nom           Norm Air Pressure


Terms Used in Verdict Column:
 P               Pass, The EUT complies with the essential requirements in the standard.
 NP              Not Perform, The test was not performed by CTTL
 NA              Not Applicable, The test was not applicable
 F               Fail, The EUT does not comply with the essential requirements in the standard


Abbreviations:
 AC              Alternating Current
 AFH             Adaptive Frequency Hopping
 BW              Band Width
 E.I.R.P.        equivalent is tropical radiated power
 ISM             Industrial, Scientific and Medical
 RF              Radio Frequency
 Tx              Transmitter



6.3. Statements
       23B




The test cases listed in Section 6.1 of this report for the EUT specified in Section 3 were performed
by CTTL according to the reference documents in Section 4.
The EUT meets all applicable requirements of the regulations and standards in Section 4.2.
This report only deals with the NFC function among the features described in section 3.




                                                                 ©Copyright. All rights reserved by CTTL.


                                                            No. I18Z62361-IOT09
                                                                   Page 12 of 24




  7. Test Equipment Utilized
                                     SERIES                          CAL.           CAL. DUE
NO.        NAME            TYPE                   PRODUCER
                                     NUMBER                        INTERVAL          DATE
                                                    Rohde &
 1.         LISN          ESH3-Z5    825562/028                       1 year       2019-08-22
                                                    Schwarz
                                                    Rohde &
 2.     Test Receiver       ESCI      100766                          1 year       2019-04-16
                                                    Schwarz
                                                    Rohde &
 3.     Test Receiver      ESU26      100376                          1 year        2019-11-27
                                                    Schwarz
 4.    BiLog Antenna      VULB9163    9163-514    Schwarz beck       3 years       2019-02-03
        Dual-Ridge
 5.   Waveguide Horn        3117     00139065     ETS-Lindgren       3 years       2020-09-21
         Antenna
 6.    H-field Antenna    HFH2-Z2    829324/007       R&S            3 years       2019-12-03
        Vector Signal                               Rohde &
 7.                        FSV40      101047                          1 year       2019-07-27
          Analyser                                  Schwarz
 8.   Spectrum Analyzer   RSA3408A    B010277       Tektronix         1 Year       2019-09-20




                                                       ©Copyright. All rights reserved by CTTL.


                                                                    No. I18Z62361-IOT09
                                                                           Page 13 of 24



ANNEX A: MEASUREMENT RESULTS

A.1. Electric Field Strength of Fundamental and Outside the Allocated bands
24B




A.1.1. Reference
See Clause 6.4 of ANSI C63.10-2013 specifically.
See Clause 4 and Clause 5 of ANSI C63.10-2013 generally.

A.1.2. Measurement Methods
The transmitter carrier output levels (E-Field) from the EUT are measured in a semi-anechoic
chamber. The EUT is placed on a non-conductive stand of 80cm high, and at a measurement
distance of 3m from the receiving antenna. The center of the receiving loop antenna is 1.0 meter
above the ground. The E-field is measured with a shielded loop antenna connected to a
measurement receiver. Detected E-field was maximized by rotating the EUT through 360° and
adjusting the receiving antenna polarizations. The maximization processes were repeated with the
EUT positioned respectively in its three orthogonal axes. The measurements were performed with
the peak detector and if required, the quasi-peak detector.
The measurement bandwidth is:
               Frequency of Emission (MHz)                            RBW/VBW
                        12.56-14.56                                    10/30 kHz


The E-field measured at 3m is calculated as:
E-field (dBµV/m) = Rx (dBµV) + Cable Loss (dB) + AF@3m (dB/m)




      A.1.3. EUT Operating Mode and Test Conditions
      The measurement of EUT is carried out under the transmit state of NFC (See 3.5).
      The EUT is powered by a travel adapter.
      During the measurements, the ambient temperature of the electromagnetic anechoic chamber is

                                                                ©Copyright. All rights reserved by CTTL.


                                                                  No. I18Z62361-IOT09
                                                                         Page 14 of 24


in the range of 15 ~ 25 ℃.


A.1.4. Limits
                              E-field Strength Limit @ 30 m      E-field Strength Limit @ 3 m
 Frequency Range (MHz)
                                          (µV/m)                           (dBµV/m)
 13.560 ± 0.007                          +15,848                                124
 13.410 to 13.553
                                           +334                                  90
 13.567 to 13.710
 13.110 to 13.410
                                           +106                                  81
 13.710 to 14.010
 Note: Where the limits have been defined at one distance, and a signal level measured at
 another, the limits have been extrapolated using the following formula:

 Extrapolation(dB)  40log10 Measurement Distance Specification Distance 


A.1.5. Measurement Results
Measurement results of normal conditions see Figure A-1 for different set-ups of EUT. The result
displayed take into account applicable antenna factors and cable losses.
Conclusions: Set. NFC03, PASS.




                                   Figure A-1: Set. NFC03
A.1.6. Measurement Uncertainty
Measurement uncertainty: U = 3.44 dB, k=2.




                                                              ©Copyright. All rights reserved by CTTL.


                                                                    No. I18Z62361-IOT09
                                                                           Page 15 of 24

A.2. Electric Field Radiated Emissions (< 30MHz)
25B




A.2.1. Reference
See Clause 6.4 of ANSI C63.10-2013 specifically.
See Clause 4 and Clause 5 of ANSI C63.10-2013 generally.

A.2.2. Measurement Methods
The transmitter carrier output levels (E-Field) from the EUT are measured in a semi-anechoic
chamber. The EUT is placed on a non-conductive stand of 80cm high, and at a measurement
distance of 3m from the receiving antenna. The center of the receiving loop antenna is 1.0 meter
above the ground. The E-field is measured with a shielded loop antenna connected to a
measurement receiver. Detected E-field was maximized by rotating the EUT through 360° and
adjusting the receiving antenna polarizations. The maximization processes were repeated with the
EUT positioned respectively in its three orthogonal axes. The measurements were performed with
the peak detector and if required, the quasi-peak detector.

The measurement bandwidth is:
               Frequency of Emission (MHz)                            RBW/VBW
                        0.009-0.15                                    100/300 Hz
                          0.15-30                                      10/30 kHz


The E-field measured at 3m is calculated as:
E-field (dBµV/m) = Rx (dBµV) + Cable Loss (dB) + AF@3m (dB/m)




      A.2.3. EUT Operating Mode and Test Conditions
      The measurement of EUT is carried out under the transmit state of NFC (See 3.5).
      The EUT is powered by a travel adapter.
      During the measurements, the ambient temperature of the electromagnetic anechoic chamber is

                                                                ©Copyright. All rights reserved by CTTL.


                                                                 No. I18Z62361-IOT09
                                                                        Page 16 of 24


in the range of 15 ~ 25 ℃.


A.2.4. Limits
                              E-field Strength Limit @ 30m       E-field Strength Limit @ 3m
 Frequency Range (MHz)
                                          (mV/m)                           (dBµV/m)
 0.009-0.490                 2400/F(kHz)                        129-94
 0.490-1.705                 24000/F(kHz)                       74-63
 1.705-30                    30                                 70
 Note: Where the limits have been defined at one distance, and a signal level measured at
 another, the limits have been extrapolated using the following formula:

 Extrapolation(dB)  40log10 Measurement Distance Specification Distance 


A.2.5. Measurement Results
Measurement results of normal conditions see Figure A-2 for different set-ups of EUT. The result
displayed take into account applicable antenna factors and cable losses.
Conclusions: Set. NFC01, PASS.




                                   Figure A-2: Set. NFC01
A.2.6. Measurement Uncertainty
Measurement uncertainty: U = 3.44 dB, k=2.




                                                             ©Copyright. All rights reserved by CTTL.


                                                                 No. I18Z62361-IOT09
                                                                        Page 17 of 24



A.3. Electric Field Radiated Emissions (≥30MHz)
26B




A.3.1. Reference
See Clause 6.5 of ANSI C63.10-2013 specifically.
See Clause 4 and Clause 5 of ANSI C63.10-2013 generally.

A.3.2. Measurement Methods
The electric field radiated emissions from the EUT are measured in a semi-anechoic chamber. The
EUT is placed on a non-conductive stand of 80cm high, and at a measurement distance of 3/10m
from the receiving antenna. The receiving antennas connected to a measurement receiver. In
order to search for maximum field strength emitted from the EUT, the receiving antenna can be
moved between the height of 1.0 m to 4.0 m. Detected E-field was maximized at each frequency
by rotating the EUT through 360° and adjusting the receiving antenna positions for both vertical
and horizontal antenna polarizations. The maximization processes were repeated with the EUT
positioned respectively in its three orthogonal axes. The measurements were performed with the
peak detector and if required, the quasi-peak detector.
The measurement bandwidth is:
          Frequency of Emission (MHz)                              RBW/VBW
                    30-1000                                          120kHz




A.3.3. EUT Operating Mode and Test Conditions
The measurement of EUT is carried out under the transmit state of NFC (See 3.5).
EUT1 had been connected to a travel adapter.
During the measurements, the ambient temperature of the electromagnetic anechoic chamber is
in the range of 15 ~ 25 ℃.


                                                             ©Copyright. All rights reserved by CTTL.


                                                                           No. I18Z62361-IOT09
                                                                                  Page 18 of 24

A.3.4. Limits
                      E-field Strength Limit          E-field Strength Limit        E-field Strength Limit
  Frequency
                               @ 3m                            @ 3m                         @ 10m
 Range (MHz)
                              (mV/m)                         (dBµV/m)                      (dBµV/m)
30-88                           100                             40                             30
88-216                          150                            43.5                           33.5
216-960                         200                             46                             36
960-1000                        500                             54                             44


A.3.5. Measurement Results
Measurement results of normal conditions see Figure A-3 for different set-ups of EUT. The result
displayed take into account applicable antenna factors and cable losses.
Conclusions: Set. NFC01, PASS.

A.3.6. Measurement Uncertainty
Measurement uncertainty: U =5.40 dB, k=2




                                         Figure A-3: Set. NFC01

Final Result 1
 Frequency      QuasiPeak   Height    Polarization   Azimuth   Corr.   Margin      Limit
   (MHz)        (dBµV/m)     (cm)                     (deg)    (dB)     (dB)     (dBµV/m)
 33.007000   23.2           125.0    V               -38.0     -0.8    16.8     40.0
 40.573000   31.1           100.0    V               93.0      0.8     8.9      40.0
 41.834000   29.9           100.0    V               126.0     0.8     10.1     40.0
 81.216000   22.5           100.0    V               266.0     -5.4    17.5     40.0
 186.26700   19.8           100.0    V               14.0      -2.5    23.7     43.5
 916.58000   31.1           118.0    V               -34.0     12.2    14.9     46.0

                                                                       ©Copyright. All rights reserved by CTTL.


                                                                   No. I18Z62361-IOT09
                                                                          Page 19 of 24



A.4. Frequency Tolerance
27B




A.4.1. Reference
See Clause 13.6 of ANSI C63.10-2013 specifically.
See Clause 4, Clause 5, and Clause 6 of ANSI C63.10-2013 generally.

A.4.2. Measurement Methods




The transmitter output signal was picked up by coil antenna connected to the frequency counter.
The center frequency was measured with 30Hz RBW and 1kHz span.
During the test, the EUT was placed in a thermal chamber until thermal balance and lasting
appropriate time.

A.4.3. EUT Operating Mode and Test Conditions
The measurement of EUT is carried out under the transmit state of without modulation (See 3.5).
EUT1 had been not connected to a travel adapter.
Operation Temperature: T min, T nom, and T max with V nom.
Operation Voltage: V min and V max with T nom.


      A.4.4. Test Layouts
      See A.4.2.

A.4.5. Limits
The frequency tolerance of the carrier signal shall be maintained within +/- 0.01% of the operating
frequency.

A.4.6. Measurement Results
Measurement results see Table A-1 for different test conditions.
Conclusions: Set. NFC02, PASS.
                                                               ©Copyright. All rights reserved by CTTL.


                                                                 No. I18Z62361-IOT09
                                                                        Page 20 of 24

Table A-1: Frequency Stability VS Temperature and Voltage


                                                    Frequency Error (MHz)
      Temperature   Voltage
                                Startup          2 Min Later      5 Min Later             10 Min Later
        T min       V nom     13.5600331         13.5600425      13.5600369               13.5600331
        T max       V nom     13.5599881         13.5599738      13.5599713               13.5599750
        T nom       V nom     13.5600006         13.5604050      13.5599994               13.5599999
        T nom       V min     13.5599919         13.5599938      13.5599931               13.5603900
        T nom       V max     13.5599863         13.5599906      13.5599925               13.5599938

                                                      Frequency Error (%)
      Temperature   Voltage
                                 Startup         2 Min Later      5 Min Later             10 Min Later
        T min       V nom         0.000             0.000            0.000                   0.000
        T max       V nom         0.000            0.000             0.000                   0.000
        T nom       V nom         0.000            0.003             0.000                   0.000
        T nom       V min         0.000            0.000             0.000                   0.003
        T nom       V max         0.000             0.000            0.000                   0.000


A.4.7. Measurement Uncertainty
Measurement uncertainty: U =77 Hz, k=2




A.5. 20dB Bandwidth
28B




A.5.1. Reference
See Clause 13.7 of ANSI C63.10-2013 specifically.
See Clause 4, Clause 5, and Clause 6 of ANSI C63.10-2013 generally.

A.5.2. Measurement Methods
The transmitter output signal was picked up by coil antenna to the spectrum analyzer.
The transmitter output signal was picked up by coil antenna connected to the spectrum analyzer.
The bandwidth of the center frequency was measured with 140Hz RBW, 420Hz VBW and 14kHz
span.




                                                             ©Copyright. All rights reserved by CTTL.


                                                                No. I18Z62361-IOT09
                                                                       Page 21 of 24

A.5.3. EUT Operating Mode and Test Conditions
The measurement of EUT is carried out under the transmit state of NFC and without modulation
(See 3.5).
EUT had been not connected to a travel adapter.

During the measurements, the ambient temperature is in the range of 15 ~ 25 ℃.

A.5.4. Test Layouts
See A.5.2.

A.5.5. Limits
The 20dB bandwidth shall be less than 80% of the permitted frequency band. For 13.56 MHz NFC,
the permitted frequency band is 14kHz, so the limit is 11.2 kHz.

A.5.6. Measurement Results
Measurement results see Figure A-4.
Conclusions: Set. NFC02, PASS.




    ‘
                   Figure A-4: Test result of EUT45 at test set. NFC02
A.5.7. Measurement Uncertainty
Measurement uncertainty: U =77 Hz, k=2




                                                            ©Copyright. All rights reserved by CTTL.


                                                                                      No. I18Z62361-IOT09
                                                                                             Page 22 of 24

A.6. Conducted emission
29B




A.6.1. Reference
See Clause 6.2 of ANSI C63.10-2013 specifically.
See Clause 4 and Clause 5 of ANSI C63.10-2013 generally.

A.6.2. Measurement Methods
The conducted emissions from the AC port of the EUT are measured in a shielding room. The EUT
is connected to a Line Impedance Stabilization Network (LISN). An overview sweep with peak
detection was performed. The measurements were performed with a quasi-peak detector and if
required, an average detector.
The conducted emission measurements were made with the following detector of the test receiver:
Quasi-Peak / Average Detector.
The measurement bandwidth is:
                Frequency of Emission (MHz)                                            RBW/VBW
                                                0.15-30                                    9kHz




                                                                     Table
                Wall of shielded room




                                                      AMN                              EUT

                                                                  Mains lead


                                                                   80 cm
                                                                                             40 cm




      A.6.3. EUT Operating Mode and Test Conditions
      The measurement of EUT is carried out under the transmit state of NFC (See 3.5).
      The EUT is powered by a travel adapter.
      During the measurements, the ambient temperature is in the range of 15 ~ 25 ℃.

      A.6.4. Limits
               Frequency range
                                                            Quasi-peak Limit (dBV)       Average Limit (dBV)
                    (MHz)
                                        0.15 to 0.5                66 to 56                          56 to 46
                                         0.5 to 5                      56                              46
                                         5 to 30                       60                              50
                                                                                 ©Copyright. All rights reserved by CTTL.


                                                                                No. I18Z62361-IOT09
                                                                                       Page 23 of 24


A.6.5. Measurement Results
Measurement results see Figure A-5.
Conclusions: Set. NFC01, PASS.
Note: The measurement result at 13.56MHz is the fundamental emission of NFC signal.




                        Figure A-5: Test result of EUT1 at test set. NFC01

Final Result 1
  Frequency    QuasiPeak      Meas. Time     Bandwidth         Line     Corr.     Margin       Limit
    (MHz)       (dBµV)              (ms)           (kHz)                (dB)          (dB)    (dBµV)
 1.365000     39.9           2000.0         9.000           L1         10.4      16.1        56.0
 1.410000     46.9           2000.0         9.000           L1         10.4      9.1         56.0
 1.540500     42.9           2000.0         9.000           L1         10.4      13.1        56.0
 2.373000     40.1           2000.0         9.000           N          10.4      15.9        56.0
 2.485500     38.5           2000.0         9.000           L1         10.4      17.5        56.0
 2.544000     43.0           2000.0         9.000           L1         10.4      13.0        56.0

Final Result 2
 Frequency    Average      Meas. Time      Bandwidth       Line       Corr.     Margin       Limit
 (MHz)        (dBµV)       (ms)            (kHz)                      (dB)      (dB)         (dBµV)
 0.537000     37.1         2000.0          9.000           N          10.4      6.6          46.0
 1.414500     40.2         2000.0          9.000           L1         10.4      5.1          46.0
 1.477500     39.4         2000.0          9.000           N          10.4      13.0         46.0
 2.359500     40.9         2000.0          9.000           L1         11.0      3.3          50.0
 2.431500     33.0         2000.0          9.000           N          10.4      6.6          46.0
 13.560000    46.7         2000.0          9.000           L1         10.4      5.1          46.0

A.6.6. Measurement Uncertainty
Measurement uncertainty: U = 3.1 dB, k=2
                                                                        ©Copyright. All rights reserved by CTTL.


                                                   No. I18Z62361-IOT09
                                                          Page 24 of 24



ANNEX A: Accreditation Certificate




                         ***END OF REPORT***




                                               ©Copyright. All rights reserved by CTTL.



Document Created: 2019-02-21 15:49:29
Document Modified: 2019-02-21 15:49:29

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC