EMC Test report

FCC ID: 2AJOTTA-1130

Test Report

Download: PDF
FCCID_4249986

                                 Test Report No.: FV190322W004



                                                                        EMC TEST REPORT
      Applicant:                           HMD Global Oy.

      Address:                             Bertel Jungin aukio 9, 02600 Espoo, Finland


      Manufacturer or
                                           HMD Global Oy
      Supplier:

      Address:                             Bertel Jungin aukio 9, 02600 Espoo, Finland


      Product:                             GSM/WCDMA/LTE Mobile Phone


      Brand Name:                          Nokia


      Model Name:                          TA-1130


      FCC ID:                              2AJOTTA-1130


      Date of tests:                       Mar. 23, 2019~ Apr. 12, 2019

      The submitted sample of the above equipment has been tested for according to the requirements of the
      following standards:

            FCC Part 15, Subpart B, Class B
            ANSI C63.4:2014

      CONCLUSION: The submitted sample was found to COMPLY with the test requirement

                               Issued by Alex Chen                                                                                    Approved by Luke Lu
                           Engineer / Mobile Department                                                                            Manager / Mobile Department




                                     Date: Apr. 15, 2019                                                                                     Date: Apr. 15, 2019
      This report is governed by, and incorporates by reference, CPS Conditions of Service as posted at the date of issuance of this report at
      http://www.bureauveritas.com/home/about-us/our-business/cps/about-us/terms-conditions/and is intended for your exclusive use. Any copying or replication of this report to or for any other person
      or entity, or use of our name or trademark, is permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results
      set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and
      expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us. Measurement uncertainty is only provided upon
      request for accredited tests. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence or if you require measurement uncertainty;
      provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute you
      unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents.




                                                             No.B102, Dazu Chuangxin Mansion, North of Beihuan                                       Tel: +86 755 8869 6566
BV 7Layers Communications
                                                             Avenue, North Area, Hi-Tech Industrial Park, Nanshan                                    Fax: +86 755 8869 6577
Technology (Shenzhen) Co. Ltd
                                                             District, Shenzhen51800, China                                                          Email: customerservice.dg@cn.bureauveritas.com
                                                                                                Page 1 of 30                                                                                 Report Version 1


                           Test Report No.: FV190322W004


                                                   TABLE OF CONTENTS

       RELEASE CONTROL RECORD ............................................................................................................... 3

       1      GENERAL INFORMATION ................................................................................................................ 4
           1.1      GENERAL DESCRIPTION OF EUT............................................................................................. 4
           1.2      SUMMARY OF TEST RESULTS .................................................................................................. 6
           1.3      MEASUREMENT UNCERTAINTY ............................................................................................... 6
           1.4      DESCRIPTION OF TEST MODES............................................................................................... 7
           1.5      DESCRIPTION OF SUPPORT UNITS ......................................................................................... 9
       2      EMISSION TEST .............................................................................................................................. 10
           2.1    CONDUCTED EMISSION MEASUREMENT ............................................................................. 10
             2.1.1   LIMITS OF CONDUCTED EMISSION MEASUREMENT .................................................. 10
             2.1.2   TEST INSTRUMENTS........................................................................................................ 10
             2.1.3   TEST PROCEDURES .........................................................................................................11
             2.1.4   DEVIATION FROM TEST STANDARD ...............................................................................11
             2.1.5   TEST SETUP ...................................................................................................................... 12
             2.1.6   EUT OPERATING CONDITIONS ....................................................................................... 12
             2.1.7   TEST RESULTS ................................................................................................................. 13
           2.2    RADIATED EMISSION MEASUREMENT .................................................................................. 17
             2.2.1.  LIMITS OF RADIATED EMISSION MEASUREMENT ....................................................... 17
             2.2.2.  TEST INSTRUMENTS........................................................................................................ 18
             2.2.3.  TEST PROCEDURE ........................................................................................................... 19
             2.2.4.  DEVIATION FROM TEST STANDARD .............................................................................. 20
             2.2.5.  TEST SETUP ...................................................................................................................... 21
             2.2.6.  EUT OPERATING CONDITIONS ....................................................................................... 21
             2.2.7.  TEST RESULTS ................................................................................................................. 22
       3 APPENDIX A – MODIFICATIONS RECORDERS FOR ENGINEERING CHANGES TO THE EUT
       BY THE LAB ............................................................................................................................................ 30




                                                 No.B102, Dazu Chuangxin Mansion, North of Beihuan                    Tel: +86 755 8869 6566
BV 7Layers Communications
                                                 Avenue, North Area, Hi-Tech Industrial Park, Nanshan                 Fax: +86 755 8869 6577
Technology (Shenzhen) Co. Ltd
                                                 District, Shenzhen51800, China                                       Email: customerservice.dg@cn.bureauveritas.com
                                                                            Page 2 of 30                                                             Report Version 1


                       Test Report No.: FV190322W004


                                  RELEASE CONTROL RECORD

         ISSUE NO.              REASON FOR CHANGE                                                          DATE ISSUED
         FV190322W004           Original release                                                           Apr. 15, 2019




                                    No.B102, Dazu Chuangxin Mansion, North of Beihuan      Tel: +86 755 8869 6566
BV 7Layers Communications
                                    Avenue, North Area, Hi-Tech Industrial Park, Nanshan   Fax: +86 755 8869 6577
Technology (Shenzhen) Co. Ltd
                                    District, Shenzhen51800, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                          Page 3 of 30                                                 Report Version 1


                       Test Report No.: FV190322W004

         1 GENERAL INFORMATION
         1.1      GENERAL DESCRIPTION OF EUT
        PRODUCT                   GSM/WCDMA/LTE Mobile Phone

        BRAND NAME                Nokia
        MODEL NAME                TA-1130
                                  5.0Vdc (adapter or host equipment)
        NOMINAL VOLTAGE
                                  3.85Vdc (Li-ion, battery)
                                                        CCK, DQPSK, DBPSK for DSSS
                                  WLAN
                                                        64QAM, 16QAM, QPSK, BPSK for OFDM
                                  BT_LE                      BT-LE(GFSK) for DTS
                                  Bluetooth                  GFSK, π/4-DQPSK, 8DPSK, LE
                                  GPS/ GLONASS               C/A code
        MODULATION TYPE
                                  FM                         FM
                                  GSM                        GMSK/8PSK
                                  WCDMA                      BPSK/QPSK
                                  LTE                        QPSK/16QAM
                                  WLAN                       2412-2462MHz for 11b/g/n(HT20)
                                  Bluetooth/BT_LE            2402MHz ~ 2480MHz
                                  GPS                        1575.42MHz
                                  GLONASS                    1602MHz
        OPERATING                 FM                         87.5MHz ~ 108MHz
        FREQUENCY                                            824.2MHz ~ 848.8MHz (FOR GSM 850)
                                  GSM
                                                             1850.2MHz ~ 1909.8MHz (FOR GSM 1900)
                                  WCDMA                      826.4MHz ~ 846.6MHz (FOR WCDMA Band 5)
                                                             824.7MHz ~ 848.3MHz   (FOR LTE Band5)
                                  LTE                        2500MHz ~ 2570MHz     (FOR LTE Band7)
                                                             2572.5MHz ~ 2617.5MHz (FOR LTE Band38)
        HW VERSION                HW0201

        SW VERSION                000C_0_310

        I/O PORTS                 Refer to user’s manual
                                  USB cable: non-shielded, detachable, 1.0meter
        CABLE SUPPLIED
                                  Earphone cable: non-shielded, detachable, 1.5meter
        ACCESSORY
        DEVICES                   Refer to note as below


                                   No.B102, Dazu Chuangxin Mansion, North of Beihuan      Tel: +86 755 8869 6566
BV 7Layers Communications
                                   Avenue, North Area, Hi-Tech Industrial Park, Nanshan   Fax: +86 755 8869 6577
Technology (Shenzhen) Co. Ltd
                                   District, Shenzhen51800, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                         Page 4 of 30                                                 Report Version 1


                       Test Report No.: FV190322W004

       NOTE:
       1. For a more detailed features description, please refer to the manufacturer’s specifications or the
          user's manual.
       2. For the test results, the EUT had been tested with all conditions. But only the worst case was shown
          in test report.



       List of Accessories:
       ACCESSORIES              BRAND       MODEL                 Manufacturer                         SPECIFICATION
                                                                  DONGGUAN AOHAI                       I/P:100-240Vac, 150mA
       AC Adapter 1             Aohai       AD-5WU(US)
                                                                  TECHNOLOGY CO., LTD.                 O/P: 5Vdc, 1A
                                                                                                       I/P:100-240Vac, 150mA
       AC Adapter 2             DVE         AD-5WU(US)            Dee Van Enterprise Co., LTD.
                                                                                                       O/P: 5Vdc, 1A
       Battery                  Lishen      HE365                 -                                    Rating: 3.85Vdc, 2500mAh
                                                                                                       1.0m shielded cable w/o
       USB Cable 1              Nokia       CA-10W                Shenglan Technology Co., Ltd
                                                                                                       core
                                            MICRO USB             RongTaiFeng Technology               1.0m shielded cable w/o
       USB Cable 2              Nokia
                                            5V2A                  Co.,Ltd                              core
                                                                                                       1.0m shielded cable w/o
       USB Cable 3              Nokia       CA-190CD              FIH
                                                                                                       core
                                                                                                       1.5m shielded cable w/o
       Earphone                 Nokia       WH-108                OBO
                                                                                                       core




                                         No.B102, Dazu Chuangxin Mansion, North of Beihuan      Tel: +86 755 8869 6566
BV 7Layers Communications
                                         Avenue, North Area, Hi-Tech Industrial Park, Nanshan   Fax: +86 755 8869 6577
Technology (Shenzhen) Co. Ltd
                                         District, Shenzhen51800, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                               Page 5 of 30                                                 Report Version 1


                       Test Report No.: FV190322W004



          1.2      SUMMARY OF TEST RESULTS
       The EUT has been tested according to the following specifications:

                                APPLIED STANDARD: FCC Part 15, Subpart B

           Standard Section                 Test Item                   Result                    Remark

                                                                                    Meets limits minimum
                                    Conducted Test                      PASS        passing margin is
                                                                                    -16.13 dB at 0.150000 MHz
           FCC Part 15,                                                             Meets Class B Limit
                              Radiated Emission
           Subpart B, Class B                                           PASS        Minimum passing margin is
                              Test (30MHz ~ 1GHz)
           ANSI C63.4:2014                                                          -3.66 dB at 39.7 MHz
                                                                                    Meets Class B Limit
                                    Radiated Emission
                                                                        PASS        Minimum passing margin is
                                    Test (Above 1GHz)
                                                                                    -14.39 dB at 4332 MHz




          1.3      MEASUREMENT UNCERTAINTY
       Where relevant, the following measurement uncertainty levels have been estimated for
       tests performed on the EUT as specified in CISPR 16-4-2:

       This uncertainty represents an expanded uncertainty expressed at approximately the
       95% confidence level using a coverage factor of k=2.

                      MEASUREMENT                         FREQUENCY                  UNCERTAINTY

                   Conducted emissions                  150kHz ~ 30MHz                    +/-2.66dB


                                                         30MHz ~ 1GHz                     +/-3.26dB
                     Radiated emissions
                                                         1GHz ~ 18GHz                     +/-4.48dB




                                   No.B102, Dazu Chuangxin Mansion, North of Beihuan      Tel: +86 755 8869 6566
BV 7Layers Communications
                                   Avenue, North Area, Hi-Tech Industrial Park, Nanshan   Fax: +86 755 8869 6577
Technology (Shenzhen) Co. Ltd
                                   District, Shenzhen51800, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                         Page 6 of 30                                                 Report Version 1


                       Test Report No.: FV190322W004


          1.4      DESCRIPTION OF TEST MODES
         Test
                                                             Test Condition
         Mode

                                                  Radiated emission test

            1       Adapter 1# + USB cable 1 + Earphone + BT Idle + WIFI idle(2.4G) + Battery + GPS RX
             2      Adapter 1# + USB cable 2 + Earphone + BT Idle + WIFI idle(2.4G) + Battery + GPS RX
             3      Adapter 1# + USB cable 3 + Earphone + BT Idle + WIFI idle(2.4G) + Battery + GPS RX
             4      Worst Case(1-3) + Adapter 2#
             5      Worst Case(1-4) + Camera On
             6      Worst Case(1-4) + Glonass Rx
             7      Worst Case(1-4) + MPG4
             8      Worst Case(1-4) + FM RX
             9      Worst Case(1-8) + GSM 850 Idle
           10       Worst Case(1-8) + GSM 1900 Idle
           11       Worst Case(1-8) + WCDMA B5 Idle
           12       Worst Case(1-8) + LTE B5 Idle
           13       Worst Case(1-8) + LTE B7 idle
           14       Worst Case(1-8) + LTE B38 idle
           15       USB Link + USB Cable1 + Data Trasmission(EUT to SD1) + Earphone
           16       USB Link + USB Cable1 + Data Trasmission(EUT to SD2) + Earphone
           17       USB Link + USB Cable1 + Data Trasmission(EUT to PC) + Earphone
           18       Worst Case(15-17) + USB Cable2
           19       Worst Case(15-17) + USB Cable3

                                                 Conducted emission test

            1       Adapter 1# + USB cable 1 + Earphone + BT Idle + WIFI idle(2.4G) + Battery + GPS RX
             2      Adapter 1# + USB cable 2 + Earphone + BT Idle + WIFI idle(2.4G) + Battery + GPS RX
             3      Adapter 1# + USB cable 3 + Earphone + BT Idle + WIFI idle(2.4G) + Battery + GPS RX
             4      Worst Case(1-3) + Adapter 2#
             5      Worst Case(1-4) + Camera On
             6      Worst Case(1-4) + Glonass Rx
             7      Worst Case(1-4) + MPG4
             8      Worst Case(1-4) + FM RX
            9       Worst Case(1-8) + GSM 850 Idle
            10      Worst Case(1-8) + GSM 1900 Idle
            11      Worst Case(1-8) + WCDMA B5 Idle
            12      Worst Case(1-8) + LTE B5 Idle
            13      Worst Case(1-8) + LTE B7 idle


                                    No.B102, Dazu Chuangxin Mansion, North of Beihuan      Tel: +86 755 8869 6566
BV 7Layers Communications
                                    Avenue, North Area, Hi-Tech Industrial Park, Nanshan   Fax: +86 755 8869 6577
Technology (Shenzhen) Co. Ltd
                                    District, Shenzhen51800, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                          Page 7 of 30                                                 Report Version 1


                       Test Report No.: FV190322W004
            14      Worst Case(1-8) + LTE B38 idle
            15      USB Link + USB Cable1 + Data Trasmission(EUT to SD1) + Earphone
            16      USB Link + USB Cable1 + Data Trasmission(EUT to SD2) + Earphone
            17      USB Link + USB Cable1 + Data Trasmission(EUT to PC) + Earphone
            18      Worst Case(15-17) + USB Cable2
            19      Worst Case(15-17) + USB Cable3
       NOTE:
       1. For conducted emission test, test mode 9, 18 was the worst case and only this mode was presented
          in this report.
       2. For radiated emission test, test mode 9, 15was the worst case and only this mode was presented in
          this report.




                                    No.B102, Dazu Chuangxin Mansion, North of Beihuan      Tel: +86 755 8869 6566
BV 7Layers Communications
                                    Avenue, North Area, Hi-Tech Industrial Park, Nanshan   Fax: +86 755 8869 6577
Technology (Shenzhen) Co. Ltd
                                    District, Shenzhen51800, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                          Page 8 of 30                                                 Report Version 1


                       Test Report No.: FV190322W004


          1.5      DESCRIPTION OF SUPPORT UNITS
       The EUT has been tested as an independent unit together with other necessary
       accessories or support units. The following support units or accessories were used to
       form a representative test configuration during the tests.

       FOR EMISSION TESTS
         NO.       PRODUCT               BRAND             MODEL NO.                SERIAL NO.                  FCC ID
                  GPS Simulator
          1                              TOJOIN            GNSS-5000A              E1-010-010119                   N/A
                    +Antenna
          2        Wireless AP          ABOCOM              WR224GR                 060500749P                     N/A
                                        Rohde &
          3     FM signal generator                          SMB100A                    109279                     N/A
                                        Schwarz
          4           Printer              HP           Hp LaserJet 1300            CNSJF75989                     N/A
          5          Notebook            Lenovo          Thnikpad X520             SL10H14859JS                    N/A


         NO.                    SIGNAL CABLE DESCRIPTION OF THE ABOVE SUPPORT UNITS
          1    N/A
          2    N/A
          3    N/A
          4    N/A
          5    N/A




                                      No.B102, Dazu Chuangxin Mansion, North of Beihuan      Tel: +86 755 8869 6566
BV 7Layers Communications
                                      Avenue, North Area, Hi-Tech Industrial Park, Nanshan   Fax: +86 755 8869 6577
Technology (Shenzhen) Co. Ltd
                                      District, Shenzhen51800, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                            Page 9 of 30                                                 Report Version 1


                       Test Report No.: FV190322W004



         2 EMISSION TEST

       2.1 CONDUCTED EMISSION MEASUREMENT

       2.1.1 LIMITS OF CONDUCTED EMISSION MEASUREMENT
         TEST STANDARD: FCC Part 15, Subpart B (Section: 15.107)

           FREQUENCY OF EMISSION (MHz)                                  CONDUCTED LIMIT (dBµV)

                                                                   Quasi-peak                          Average
                           0.15 ~ 0.5                                66 to 56                          56 to 46
                            0.5 ~ 5                                    56                                46
                             5 ~ 30                                    60                                50


         NOTE: 1.The lower limit shall apply at the transition frequencies.
                  2. The limit decreases in line with the logarithm of the frequency in the range of 0.15 to
                    0.50MHz.
                  3. All emanations from a class A/B digital device or system, including any network of conductors
                   and apparatus connected thereto, shall not exceed the level of field strengths specified above.




       2.1.2 TEST INSTRUMENTS
      Equipment                 Manufacturer         Model No.         Serial No.     Last Cal.         Next Cal.
      EMI Test Receiver         Rohde&Schwarz        ESR3              101900         Feb. 26,19        Feb. 25, 20
      EMC32 test software       Rohde&Schwarz        EMC32             NA             NA                NA
      LISN network              Rohde&Schwarz        ENV216            101922         Feb. 26,19        Feb. 25, 20
        NOTE:      1. The test was performed in CE shielded room.
                   2. The calibration interval of the above test instruments is 12 months and the calibrations are
                      traceable to CEPREI/CHINA, GRGT/CHINA and NIM/CHINA.




                                      No.B102, Dazu Chuangxin Mansion, North of Beihuan      Tel: +86 755 8869 6566
BV 7Layers Communications
                                      Avenue, North Area, Hi-Tech Industrial Park, Nanshan   Fax: +86 755 8869 6577
Technology (Shenzhen) Co. Ltd
                                      District, Shenzhen51800, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                          Page 10 of 30                                                  Report Version 1


                       Test Report No.: FV190322W004


       2.1.3 TEST PROCEDURES

          a. The EUT was placed 0.4 meters from the conducting wall of the shielded room with
             EUT being connected to the power mains through a line impedance stabilization
             network (LISN). Other support units were connected to the power mains through
             another LISN. The two LISNs provide 50 ohm/ 50uH of coupling impedance for the
             measuring instrument.

          b. Both lines of the power mains connected to the EUT were checked for maximum
             conducted interference.

          c. The frequency range from 150 kHz to 30MHz was searched. Emission levels under
             (Limit - 20dB) were not recorded.


         NOTE: All modes of operation were investigated and the worst-case emissions are reported.



       2.1.4 DEVIATION FROM TEST STANDARD

         No deviation.




                                   No.B102, Dazu Chuangxin Mansion, North of Beihuan      Tel: +86 755 8869 6566
BV 7Layers Communications
                                   Avenue, North Area, Hi-Tech Industrial Park, Nanshan   Fax: +86 755 8869 6577
Technology (Shenzhen) Co. Ltd
                                   District, Shenzhen51800, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                        Page 11 of 30                                                 Report Version 1


                       Test Report No.: FV190322W004




       2.1.5 TEST SETUP

                                     V e r tic a l G r o u n d

                                     R e fe r e n c e P la n e                                            T e s t R e c e iv e r



                                      EUT
                    40cm




                                                                      80cm

                    L IS N




                                                                                      H o r iz o n ta l G r o u n d

                                                                                       R e fe r e n c e P la n e


                      N o t e : 1 .S u p p o r t u n its w e r e c o n n e c t e d t o s e c o n d L IS N .

                                2 .B o th o f L IS N s ( A M N ) a r e 8 0 c m fr o m E U T a n d a t le a s t 8 0

                       cm         f r o m o t h e r u n its a n d o t h e r m e ta l p la n e s

                         s u p p o rt.   u n i ts .


         For the actual test configuration, please refer to the attached file (Test Setup Photo).


       2.1.6 EUT OPERATING CONDITIONS

          a. Turned on the power and connected of all equipment.
          b. EUT was operated according to the use type described in the manufacturer’s
            specifications or the user's manual.




                                          No.B102, Dazu Chuangxin Mansion, North of Beihuan       Tel: +86 755 8869 6566
BV 7Layers Communications
                                          Avenue, North Area, Hi-Tech Industrial Park, Nanshan    Fax: +86 755 8869 6577
Technology (Shenzhen) Co. Ltd
                                          District, Shenzhen51800, China                          Email: customerservice.dg@cn.bureauveritas.com
                                                                 Page 12 of 30                                                Report Version 1


                       Test Report No.: FV190322W004

       2.1.7 TEST RESULTS
       Mode 9
                                                 DC 5V From Adapter               Detector Function &  Quasi-Peak (QP) /
          TEST VOLTAGE
                                                 Input 120 Vac, 60 Hz             Resolution Bandwidth Average (AV), 9 kHz
          ENVIRONMENTAL
                        25deg. C, 52RH                                            TESTED BY                      John Wen
          CONDITIONS

           Frequency       QuasiPeak                     CAverage           Limit        Margin                                     Corr.
                                                                                                       Line         Filter
             (MHz)          (dBuV)                        (dBuV)           (dBuV)         (dB)                                      (dB)
           0.564000                      ---                21.01           46.00         -24.99         L           ON              10.0
           0.564000                     34.65                ---            56.00         -21.35         L           ON              10.0
           1.200000                      ---                19.98           46.00         -26.02         L           ON              10.1
           1.200000                     32.65                ---            56.00         -23.35         L           ON              10.1
           1.480000                      ---                19.99           46.00         26.01          L           ON              10.1
           1.480000                     31.58                ---            56.00         -24.42         L           ON              10.1
           2.316000                      ---                14.75           46.00         -31.25         L           ON              10.2
           2.316000                     25.00                ---            56.00         -31.00         L           ON              10.2
           4.248000                      ---                17.87           46.00         -28.13         L           ON              10.2
           4.248000                     29.97                ---            56.00         -26.03         L           ON              10.2
           15.908000                     ---                23.97           50.00         -26.03         L           ON              10.5
           15.908000                    32.28                ---            60.00         -27.72         L           ON              10.5

       REMARKS: 1. Q.P. and AV. are abbreviations of quasi-peak and average individually.
               2. "-": The Quasi-peak reading value also meets average limit and
                   measurement with the average detector is unnecessary.
               3. The emission levels of other frequencies were very low against the limit.
               4. Margin value = Emission level - Limit value
               5. Correction factor = Insertion loss + Cable loss
               6. Emission Level = Correction Factor + Reading Value.
                                Lev el in dB μ




                                                      No.B102, Dazu Chuangxin Mansion, North of Beihuan       Tel: +86 755 8869 6566
BV 7Layers Communications
                                                      Avenue, North Area, Hi-Tech Industrial Park, Nanshan    Fax: +86 755 8869 6577
Technology (Shenzhen) Co. Ltd
                                                      District, Shenzhen51800, China                          Email: customerservice.dg@cn.bureauveritas.com
                                                                          Page 13 of 30                                                   Report Version 1


                       Test Report No.: FV190322W004

                                DC 5V From Adapter                            Detector Function &  Quasi-Peak (QP) /
       TEST VOLTAGE
                                Input 120 Vac, 60 Hz                          Resolution Bandwidth Average (AV), 9 kHz
       ENVIRONMENTAL
                                25deg. C, 52RH                                TESTED BY                      John Wen
       CONDITIONS

           Frequency       QuasiPeak                   CAverage           Limit        Margin                                     Corr.
                                                                                                     Line         Filter
              (MHz)         (dBuV)                      (dBuV)           (dBuV)         (dB)                                      (dB)
            0.174000          ---                        24.09            54.77        -30.68          N           ON              9.9
            0.174000         37.84                        ---             64.77        -26.93          N           ON              9.9
            0.580000          ---                        26.82            46.00        -19.18          N           ON              9.9
            0.580000         36.26                        ---             56.00        -19.74          N           ON              9.9
            1.232000          ---                        21.50            46.00        -24.50          N           ON             10.0
            1.232000         32.79                        ---             56.00        -23.21          N           ON             10.0
            1.568000          ---                        21.23            46.00        -24.77          N           ON             10.0
            1.568000         33.09                        ---             56.00        -22.91          N           ON             10.0
           15.828000          ---                        30.85            50.00        -19.15          N           ON             10.4
           15.828000         41.67                        ---             60.00        -18.33          N           ON             10.4
           18.148000          ---                        26.85            50.00        -23.15          N           ON             10.4
           18.148000         38.94                        ---             60.00        -21.06          N           ON             10.4


       REMARKS: 1. Q.P. and AV. are abbreviations of quasi-peak and average individually.
               2. "-": The Quasi-peak reading value also meets average limit and
                   measurement with the average detector is unnecessary.
               3. The emission levels of other frequencies were very low against the limit.
               4. Margin value = Emission level - Limit value
               5. Correction factor = Insertion loss + Cable loss
               6. Emission Level = Correction Factor + Reading Value.
                                   Lev el in dB μ




                                                    No.B102, Dazu Chuangxin Mansion, North of Beihuan       Tel: +86 755 8869 6566
BV 7Layers Communications
                                                    Avenue, North Area, Hi-Tech Industrial Park, Nanshan    Fax: +86 755 8869 6577
Technology (Shenzhen) Co. Ltd
                                                    District, Shenzhen51800, China                          Email: customerservice.dg@cn.bureauveritas.com
                                                                        Page 14 of 30                                                   Report Version 1


                       Test Report No.: FV190322W004

       Mode 18
                                   Data trasmission                          Detector Function &  Quasi-Peak (QP) /
          TEST VOLTAGE
                                   Input 120 Vac, 60 Hz                      Resolution Bandwidth Average (AV), 9 kHz
          ENVIRONMENTAL
                        25deg. C, 52RH                                       TESTED BY                      John Wen
          CONDITIONS

           Frequency       QuasiPeak                CAverage           Limit        Margin                                     Corr.
                                                                                                  Line         Filter
             (MHz)          (dBuV)                   (dBuV)           (dBuV)         (dB)                                      (dB)
            0.150000          ---                     31.19            56.00         -24.81         L           ON               9.9
            0.150000         49.67                     ---             66.00         -16.33         L           ON               9.9
            0.360000          ---                     15.29            48.73         -33.44         L           ON              10.0
            0.360000         27.25                     ---             58.73         -31.47         L           ON              10.0
            0.504000          ---                     25.74            46.00         -20.26         L           ON              10.0
            0.504000         35.53                     ---             56.00         -20.47         L           ON              10.0
            1.464000          ---                     17.18            46.00         -28.82         L           ON              10.1
            1.464000         24.05                     ---             56.00         -31.95         L           ON              10.1
            3.612000          ---                     15.02            46.00         -30.98         L           ON              10.2
            3.612000         24.97                     ---             56.00         -31.03         L           ON              10.2
            4.180000          ---                     16.50            46.00         -29.50         L           ON              10.2
            4.180000         29.67                     ---             56.00         -26.33         L           ON              10.2

       REMARKS: 1. Q.P. and AV. are abbreviations of quasi-peak and average individually.
               2. "-": The Quasi-peak reading value also meets average limit and
                   measurement with the average detector is unnecessary.
               3. The emission levels of other frequencies were very low against the limit.
               4. Margin value = Emission level - Limit value
               5. Correction factor = Insertion loss + Cable loss
               6. Emission Level = Correction Factor + Reading Value.
                                Lev el in dB μ




                                                 No.B102, Dazu Chuangxin Mansion, North of Beihuan       Tel: +86 755 8869 6566
BV 7Layers Communications
                                                 Avenue, North Area, Hi-Tech Industrial Park, Nanshan    Fax: +86 755 8869 6577
Technology (Shenzhen) Co. Ltd
                                                 District, Shenzhen51800, China                          Email: customerservice.dg@cn.bureauveritas.com
                                                                     Page 15 of 30                                                   Report Version 1


                       Test Report No.: FV190322W004

                                Data trasmission                            Detector Function &  Quasi-Peak (QP) /
       TEST VOLTAGE
                                Input 120 Vac, 60 Hz                        Resolution Bandwidth Average (AV), 9 kHz
       ENVIRONMENTAL
                                25deg. C, 52RH                              TESTED BY                     John Wen
       CONDITIONS


        Frequency       QuasiPeak                 CAverage          Limit         Margin                                    Corr.
                                                                                                Line       Filter
           (MHz)         (dBuV)                    (dBuV)          (dBuV)          (dB)                                     (dB)
         0.150000          ---                      32.74           56.00         -23.26          N          ON              9.9
         0.150000         49.87                      ---            66.00         -16.13          N          ON              9.9
         0.372000          ---                      21.98           48.46         -26.47          N          ON              9.9
         0.372000         30.80                      ---            58.46         -27.65          N          ON              9.9
         0.500000          ---                      26.07           46.00         -19.93          N          ON              9.9
         0.500000         35.81                      ---            56.00         -20.19          N          ON              9.9
         1.292000          ---                      17.19           46.00         -28.81          N          ON             10.0
         1.292000         25.75                      ---            56.00         -30.25          N          ON             10.0
         3.498000          ---                      13.69           46.00         -32.31          N          ON             10.1
         3.498000         23.04                      ---            56.00         -32.96          N          ON             10.1
         4.716000          ---                      17.55           46.00         -28.45          N          ON             10.1
         4.716000         25.73                      ---            56.00         -30.27          N          ON             10.1

       REMARKS: 1. Q.P. and AV. are abbreviations of quasi-peak and average individually.
               2. "-": The Quasi-peak reading value also meets average limit and
                   measurement with the average detector is unnecessary.
               3. The emission levels of other frequencies were very low against the limit.
               4. Margin value = Emission level - Limit value
               5. Correction factor = Insertion loss + Cable loss
               6. Emission Level = Correction Factor + Reading Value.
                                 Lev el in dB μ




                                                  No.B102, Dazu Chuangxin Mansion, North of Beihuan      Tel: +86 755 8869 6566
BV 7Layers Communications
                                                  Avenue, North Area, Hi-Tech Industrial Park, Nanshan   Fax: +86 755 8869 6577
Technology (Shenzhen) Co. Ltd
                                                  District, Shenzhen51800, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                                      Page 16 of 30                                                  Report Version 1


                       Test Report No.: FV190322W004


       2.2 RADIATED EMISSION MEASUREMENT

       2.2.1. LIMITS OF RADIATED EMISSION MEASUREMENT
       TEST STANDARD: FCC Part 15, Subpart B (Section: 15.109)
       Emissions radiated outside of the specified bands, shall be according to the general
       radiated limits as following:

                                Radiated Emissions Limits at 10 meters (dBμV/m)
                                   FCC 15B/                FCC 15B /
         Frequencies                                                                CISPR 22,                CISPR 22,
                                   ICES-003,               ICES-003,
            (MHz)                                                                    Class A                  Class B
                                    Class A                 Class B
              30-88                   39                      29.5
              88-216                 43.5                     33.1                           40                     30
             216-230
                                      46.4                      35.6
             230-960
                                                                                             47                     37
            960-1000                 49.5                    43.5
           1000-3000               Avg: 49.5               Avg: 43.5               Not defined              Not defined
              3000+                Peak: 69.5              Peak: 63.5              Not defined              Not defined

                                Radiated Emissions Limits at 3 meters (dBμV/m)
                                   FCC 15B /               FCC 15B /
         Frequencies                                                                CISPR 22,                CISPR 22,
                                   ICES-003,               ICES-003,
            (MHz)                                                                    Class A                  Class B
                                    Class A                 Class B
              30-88                  49.5                      40
              88-216                  54                      43.5                       50.5                     40.5
             216-230
                                      56.9                       46
             230-960
                                                                                         57.5                     47.5
            960-1000                   60                        54
           1000-3000                                                                 Avg: 56                  Avg: 50
                                    Avg: 60                 Avg: 54                  Peak: 76                 Peak: 70
              3000+                 Peak: 80                Peak: 74                 Avg: 60                  Avg: 54
                                                                                     Peak: 80                 Peak: 74




                                      No.B102, Dazu Chuangxin Mansion, North of Beihuan       Tel: +86 755 8869 6566
BV 7Layers Communications
                                      Avenue, North Area, Hi-Tech Industrial Park, Nanshan    Fax: +86 755 8869 6577
Technology (Shenzhen) Co. Ltd
                                      District, Shenzhen51800, China                          Email: customerservice.dg@cn.bureauveritas.com
                                                          Page 17 of 30                                                   Report Version 1


                       Test Report No.: FV190322W004

       Frequency Range (For unintentional radiators)
           Highest frequency generated or used in the                         Upper frequency of measurement
           device or on which the device operates or                                    range (MHz)
                          tunes (MHz)
                                Below 1.705                                                  30
                                 1.705-108                                                  1000
                                  108-500                                                   2000
                                 500-1000                                                   5000
                                                                             5 harmonic of the highest frequency
                                                                              th
                                Above 1000
                                                                                 or 40GHz, whichever is lower

       NOTE: 1. The lower limit shall apply at the transition frequencies.
             2. Emission level (dBuV/m) = 20 log Emission level (uV/m).
             3. As shown in 15.35(b), for frequencies above 1000MHz, the field strength limits are based on
                average detector, however, the peak field strength of any emission shall not exceed the
                maximum permitted average limits, specified above by more than 20dB under any condition of
                modulation.
                4. QP detector shall be applied if not specified.




       2.2.2. TEST INSTRUMENTS

       Frequency range below1GHz
          Equipment            Manufacturer             Model No.  Serial No.                 Last Cal.        Next Cal.
          3m Semi-anechoic                                         Euroshieldpn-
                               ETS-LINDGREN             9m*6m*6m                              Feb. 26,19 Feb. 25,20
          Chamber                                                  CT0001143-1216
          Bilog Antenna        ETS-LINDGREN             3143B      00161965                   Feb. 26,19 Feb. 25,20
          MXE EMI Receiver KEYSIGHT                     N9038A-544 MY54450026                 Feb. 26,19 Feb. 25,20
          Signal Pre-Amplifier EMSI                     EMC 9135 980249                       Jul. 09,18 Jul. 08,19

       Frequency range above 1GHz
          Equipment          Manufacturer               Model No.   Serial No.       Last Cal.   Next Cal.
          3m Semi-anechoic                                          Euroshieldpn-
                             ETS-LINDGREN             9m*6m*6m                       Feb. 26,19 Feb. 25,20
          Chamber                                                   CT0001143-1216
          Horn Antenna       ETS-LINDGREN             3117          00168728         Feb. 26,19 Feb. 25,20
          MXE EMI Receiver KEYSIGHT                   N9038A-544 MY54450026          Feb. 26,19 Feb. 25, 20
                                                      EMC
           Signal Pre-Amplifier EMSI                                980257           Jul. 09,18 Jul. 08,19
                                                      012645B
          NOTE: 1. The test was performed in 3m chamber.
                 2. The calibration interval of the above test instruments is 12 months or 24 months and the
                    calibrations are traceable to CEPREI/CHINA, GRGT/CHINA and NIM/CHINA.
                3. The FCC Site Registration No. is 525120; The Designation No. is CN1171.




                                     No.B102, Dazu Chuangxin Mansion, North of Beihuan      Tel: +86 755 8869 6566
BV 7Layers Communications
                                     Avenue, North Area, Hi-Tech Industrial Park, Nanshan   Fax: +86 755 8869 6577
Technology (Shenzhen) Co. Ltd
                                     District, Shenzhen51800, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                         Page 18 of 30                                                  Report Version 1


                       Test Report No.: FV190322W004


       2.2.3. TEST PROCEDURE

       <Frequency Range below 1GHz>

       The basic test procedure was in accordance with ANSI C63.4:2014 (section 12).
       a. The EUT was placed on the top of a rotating table 0.8 meters above the ground at a
          3 meter semi-anechoic chamber room. The table was rotated 360 degrees to
          determine the position of the highest radiation.
       b. The EUT was set 3 meters away from the interference-receiving antenna, which was
          mounted on the top of a variable-height antenna tower.
       c. The height of antenna is varied from 1 meter to 4 meters above the ground to
          determine the maximum value of the field strength. Both horizontal and vertical
          polarizations of the antenna are set to make the measurement.
       d. For each suspected emission, the EUT was arranged to its worst case and then the
          antenna was tuned to heights from 1 meter to 4 meters and the rotatable table was
          turned from 0 degrees to 360 degrees to find the maximum reading.
       e. The test-receiver system was set to quasi-peak detect function and specified
          bandwidth with maximum hold mode when the test frequency is below 1GHz.

          NOTE:
          1. The resolution bandwidth of test receiver/spectrum analyzer is 120kHz for Quasi-peak detection
             (QP) at frequency below 1GHz.

          2. Emission level(dBuV/m)=Raw Value(dBuV) + Correction Factor(dB/m)

          3. Correction Factor(dB/m) = Antenna Factor (dB/m) + Cable Factor (dB) (if the raw value not
             contains the amplifier);

          4. Correction Factor(dB/m) = Antenna Factor (dB/m) + Cable Factor (dB) – Amplifier Gain(dB) (if
             the raw value contains the amplifier).

          5. Margin value = Emission level – Limit value.




                                   No.B102, Dazu Chuangxin Mansion, North of Beihuan      Tel: +86 755 8869 6566
BV 7Layers Communications
                                   Avenue, North Area, Hi-Tech Industrial Park, Nanshan   Fax: +86 755 8869 6577
Technology (Shenzhen) Co. Ltd
                                   District, Shenzhen51800, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                       Page 19 of 30                                                  Report Version 1


                       Test Report No.: FV190322W004

       <Frequency Range above 1GHz>

         a. The EUT was placed on the top of a rotating table 0.8 meters above the ground
            at a 3 meter fully-anechoic chamber room. The table was rotated 360 degrees to
            determine the position of the highest radiation.
          b. The EUT was set 3 meters away from the interference-receiving antenna, which
             was mounted on the top of a variable-height antenna tower.
          c. The height of antenna is varied from one meter to four meters above the ground
             to determine the maximum value of the field strength. Both horizontal and
             vertical polarizations of the antenna are set to make the measurement. The
             bore sight should be used during the test above 1GHz.
         d. For each suspected emission, the EUT was arranged to its worst case and then
            the antenna was tuned to heights from 1 meter to 4 meters and the rotatable
            table was turned from 0 degrees to 360 degrees to find the maximum reading.
         e. The test-receiver system was set to peak and average detect function and
            specified bandwidth with maximum hold mode when the test frequency is above
            1 GHz
         NOTE:
          1. The resolution bandwidth of test receiver/spectrum analyzer is 120kHz for Quasi-peak detection
             (QP) at frequency below 1GHz.
          2. The resolution bandwidth is 1MHz and video bandwidth of test receiver/spectrum analyzer is 3MHz
             for Peak detection at frequency above 1GHz. The resolution bandwidth of test receiver/spectrum
             analyzer is 1 MHz and video bandwidth of test receiver/spectrum analyzer is 1Hz for Average
             detection (AV) at frequency above 1GHz.
          3. For measurement of frequency above 1000 MHz, the EUT was set 3 meters away from the receiver
             antenna.
          4. Emission level(dBuV/m)=Raw Value(dBuV) + Correction Factor(dB/m)
          5. Correction Factor(dB/m) = Antenna Factor (dB/m) + Cable Factor (dB) (if the raw value not contains
             the amplifier);
          6. Correction Factor(dB/m) = Antenna Factor (dB/m) + Cable Factor (dB) – Amplifier Gain(dB) (if the
             raw value contains the amplifier)
          7. Margin value = Emission level – Limit value.



       2.2.4. DEVIATION FROM TEST STANDARD

       No deviation.




                                   No.B102, Dazu Chuangxin Mansion, North of Beihuan      Tel: +86 755 8869 6566
BV 7Layers Communications
                                   Avenue, North Area, Hi-Tech Industrial Park, Nanshan   Fax: +86 755 8869 6577
Technology (Shenzhen) Co. Ltd
                                   District, Shenzhen51800, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                       Page 20 of 30                                                  Report Version 1


                       Test Report No.: FV190322W004


       2.2.5. TEST SETUP

          <Frequency Range below 1GHz>
                                                                Ant. Tower
                                                                                           1-4m
                                                                                           Variable
                                               3m
               EUT&
               Support Units

                                         Turn Table

                   0.8m


                                             Ground Plane

                                              Test Receiver




          <Frequency Range above 1GHz>


                                                           Ant. Tower                     1-4m*
                                                                                          Variable
             EUT&                             3m                                               Bore Sight
            Support Units
                                 Turn
                                 Table
                                               Absorber

                0.8m


                                          Ground Plane

                                           Test Receiver

                                                                                                   Pre-amplifier



       * : depends on the EUT height and the antenna 3dB beamwidth both, refer to section
           7.3 of CISPR 16-2-3.
       2.2.6. EUT OPERATING CONDITIONS

              Same as item 2.1.6.


                                   No.B102, Dazu Chuangxin Mansion, North of Beihuan       Tel: +86 755 8869 6566
BV 7Layers Communications
                                   Avenue, North Area, Hi-Tech Industrial Park, Nanshan    Fax: +86 755 8869 6577
Technology (Shenzhen) Co. Ltd
                                   District, Shenzhen51800, China                          Email: customerservice.dg@cn.bureauveritas.com
                                                       Page 21 of 30                                                   Report Version 1


                       Test Report No.: FV190322W004


       2.2.7. TEST RESULTS
       Mode 9
                                DC 5V From Adapter
        TEST VOLTAGE                                               FREQUENCY RANGE                  30-1000 MHz
                                Input 120 Vac, 60 Hz
                                                                   DETECTOR FUNCTION
        ENVIRONMENTAL
                      23deg. C, 70 %RH                             & RESOLUTION                     Quasi-Peak, 120 kHz
        CONDITIONS
                                                                   BANDWIDTH

        TESTED BY               Rose Ma


                                ANTENNA POLARITY & TEST DISTANCE: HORIZONTAL AT 3 M
                    EMISSION READ                              ANTENNA CABLE PREAMP ANTENNA TABLE
           FREQ.                      LIMIT  MARGIN
                     LEVEL   LEVEL                              FACTOR   LOSS FACTOR HEIGHT  ANGLE REMARK
           (MHz)                    (dBuV/m)  (dB)
                    (dBuV/m) (dBuV)                              (dB /m)  (dB)  (dB)  (cm)  (Degree)
           39.7        24.13     47.15     40        -15.87       13.55       0.91      37.48        100            124          QP
           86.26       21.61     49.09     40        -18.39        8.35       1.25      37.08        100            254          QP
          196.84       20.58     44.64    43.5       -22.92       10.72       1.78      36.56        100            319          QP
          223.03       22.29     45.1      46        -23.71       11.81       1.91      36.53        100            218          QP
          296.75       18.53     38.8      46        -27.47       14.03        2.2      36.5         100            168          QP
          422.85       25.69     42.26     46        -20.31        17.5        2.7      36.77        100            238          QP

        REMARKS:        1. Peak detector quick scan is showed on the graph and final quasi-peak detector data is
                           measured corresponding to relevant limit and recorded in the data table.
                        2. Negative sign (-) in the margin column signify levels below the limit.
                        3. Frequency range scanned: 30MHz to 1000MHz.
                        4. Only emissions significantly above equipment noise floor are reported.




                                      No.B102, Dazu Chuangxin Mansion, North of Beihuan      Tel: +86 755 8869 6566
BV 7Layers Communications
                                      Avenue, North Area, Hi-Tech Industrial Park, Nanshan   Fax: +86 755 8869 6577
Technology (Shenzhen) Co. Ltd
                                      District, Shenzhen51800, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                          Page 22 of 30                                                   Report Version 1


                       Test Report No.: FV190322W004

                                DC 5V From Adapter
        TEST VOLTAGE                                               FREQUENCY RANGE                  30-1000 MHz
                                Input 120 Vac, 60 Hz
                                                                   DETECTOR FUNCTION
        ENVIRONMENTAL
                      23deg. C, 70 %RH                             & RESOLUTION                     Quasi-Peak, 120 kHz
        CONDITIONS
                                                                   BANDWIDTH

        TESTED BY               Rose Ma


                                ANTENNA POLARITY & TEST DISTANCE: VERTICAL AT 3 M
                    EMISSION READ                              ANTENNA CABLE PREAMP ANTENNA TABLE
           FREQ.                      LIMIT  MARGIN
                     LEVEL   LEVEL                              FACTOR   LOSS FACTOR HEIGHT  ANGLE REMARK
           (MHz)                    (dBuV/m)  (dB)
                    (dBuV/m) (dBuV)                              (dB /m)  (dB)  (dB)  (cm)  (Degree)
           39.7        36.34     59.19     40         -3.66       13.72       0.91      37.48        100            158          QP
          84.32        28.88     56.32     40        -11.12        8.43       1.23      37.1         100            318          QP
          183.26       19.61     44.1     43.5       -23.89       10.47       1.71      36.67        100            259          QP
          249.22       18.63     39.95     46        -27.37       13.16       2.04      36.52        100            128          QP
          422.85       22.34     38.79     46        -23.66       17.62        2.7      36.77        100            109          QP
          486.87       23.67     39.14     46        -22.33       18.52       2.94      36.93        100            167          QP

        REMARKS:        1. Peak detector quick scan is showed on the graph and final quasi-peak detector data is
                           measured corresponding to relevant limit and recorded in the data table.
                        2. Negative sign (-) in the margin column signify levels below the limit.
                        3. Frequency range scanned: 30MHz to 1000MHz.
                        4. Only emissions significantly above equipment noise floor are reported.




                                      No.B102, Dazu Chuangxin Mansion, North of Beihuan      Tel: +86 755 8869 6566
BV 7Layers Communications
                                      Avenue, North Area, Hi-Tech Industrial Park, Nanshan   Fax: +86 755 8869 6577
Technology (Shenzhen) Co. Ltd
                                      District, Shenzhen51800, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                          Page 23 of 30                                                   Report Version 1


                       Test Report No.: FV190322W004

                                   DC 5V From Adapter
        TEST VOLTAGE                                               FREQUENCY RANGE                 1-18 GHz
                                   Input 120 Vac, 60 Hz
                                                                   DETECTOR FUNCTION
        ENVIRONMENTAL
                                   23deg. C, 70 %RH                & RESOLUTION                    Peak/Average, 1 MHz
        CONDITIONS
                                                                   BANDWIDTH
        TESTED BY                  Rose Ma


                                ANTENNA POLARITY & TEST DISTANCE: HORIZONTAL AT 3 M
                    EMISSION READ                             ANTENNA CABLE PREAMP ANTENNA TABLE
           FREQ.                      LIMIT  MARGIN
                     LEVEL   LEVEL                             FACTOR   LOSS FACTOR HEIGHT  ANGLE REMARK
           (MHz)                    (dBuV/m)  (dB)
                    (dBuV/m) (dBuV)                             (dB /m)  (dB)  (dB)  (cm)  (Degree)
          2456         34.16    42.36      54       -19.84     33.22     4.95     46.37      100    247    Average
          2456         44.14    52.34      74       -29.86     33.22     4.95     46.37      100    247      Peak
          3689         39.01    43.67      54       -14.99     35.97     5.75     46.38      100    306    Average
          3689         49.61    54.27      74       -24.39     35.97     5.75     46.38      100    306      Peak
          4687         39.29    43.85      54       -14.71     35.55     6.28     46.39      100    149    Average
          4687         47.76    52.32      74       -26.24     35.55     6.28     46.39      100    149      Peak
        REMARKS:        1. Peak detector quick scan is showed on the graph and final quasi-peak detector data is
                           measured corresponding to relevant limit and recorded in the data table.
                        2. Negative sign (-) in the margin column signify levels below the limit.
                        3. Frequency range scanned: 1GHz to 18GHz.
                        4. Only emissions significantly above equipment noise floor are reported.




                                     No.B102, Dazu Chuangxin Mansion, North of Beihuan      Tel: +86 755 8869 6566
BV 7Layers Communications
                                     Avenue, North Area, Hi-Tech Industrial Park, Nanshan   Fax: +86 755 8869 6577
Technology (Shenzhen) Co. Ltd
                                     District, Shenzhen51800, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                         Page 24 of 30                                                  Report Version 1


                       Test Report No.: FV190322W004

                                  DC 5V From Adapter
        TEST VOLTAGE                                               FREQUENCY RANGE                 1-18 GHz
                                  Input 120 Vac, 60 Hz
                                                                   DETECTOR FUNCTION
        ENVIRONMENTAL
                                  23deg. C, 70 %RH                 & RESOLUTION                    Peak/Average, 1 MHz
        CONDITIONS
                                                                   BANDWIDTH
        TESTED BY                 Rose Ma


                                ANTENNA POLARITY & TEST DISTANCE: VERTICAL AT 3 M
                    EMISSION READ                             ANTENNA CABLE PREAMP ANTENNA TABLE
           FREQ.                      LIMIT  MARGIN
                     LEVEL   LEVEL                             FACTOR   LOSS FACTOR HEIGHT  ANGLE REMARK
           (MHz)                    (dBuV/m)  (dB)
                    (dBuV/m) (dBuV)                             (dB /m)  (dB)  (dB)  (cm)  (Degree)
          2631         31.72    40.37      54       -22.28     32.58     5.14     46.37      100    138    Average
          2631         42.45     51.1      74       -31.55     32.58     5.14     46.37      100    138      Peak
          3552         36.13    42.96      54       -17.87      33.7     5.85     46.38      100    268    Average
          3552         43.96    50.79      74       -30.04      33.7     5.85     46.38      100    268      Peak
          4635         38.95    43.26      54       -15.05     35.98      6.1     46.39      100    306    Average
          4635         46.18    50.49      74       -27.82     35.98      6.1     46.39      100    306      Peak
        REMARKS:        1. Peak detector quick scan is showed on the graph and final quasi-peak detector data is
                           measured corresponding to relevant limit and recorded in the data table.
                        2. Negative sign (-) in the margin column signify levels below the limit.
                        3. Frequency range scanned: 1GHz to 18GHz.
                        4. Only emissions significantly above equipment noise floor are reported.




                                     No.B102, Dazu Chuangxin Mansion, North of Beihuan      Tel: +86 755 8869 6566
BV 7Layers Communications
                                     Avenue, North Area, Hi-Tech Industrial Park, Nanshan   Fax: +86 755 8869 6577
Technology (Shenzhen) Co. Ltd
                                     District, Shenzhen51800, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                         Page 25 of 30                                                  Report Version 1


                       Test Report No.: FV190322W004

          Mode 15
                                Data trasmission
        TEST VOLTAGE                                               FREQUENCY RANGE                  30-1000 MHz
                                Input 120 Vac, 60 Hz
                                                                   DETECTOR FUNCTION
        ENVIRONMENTAL
                      23deg. C, 70 %RH                             & RESOLUTION                     Quasi-Peak, 120 kHz
        CONDITIONS
                                                                   BANDWIDTH

        TESTED BY               Rose Ma


                                ANTENNA POLARITY & TEST DISTANCE: HORIZONTAL AT 3 M
                    EMISSION READ                              ANTENNA CABLE PREAMP ANTENNA TABLE
           FREQ.                      LIMIT  MARGIN
                     LEVEL   LEVEL                              FACTOR   LOSS FACTOR HEIGHT  ANGLE REMARK
           (MHz)                    (dBuV/m)  (dB)
                    (dBuV/m) (dBuV)                              (dB /m)  (dB)  (dB)  (cm)  (Degree)
          71.71        21.23     49.67     40        -18.77        7.6         1.2      37.24        100            90           QP
          199.75       25.85     49.81    43.5       -17.65       10.79       1.79      36.54        100            90           QP
          225.94       28.2      50.87     46         -17.8       11.94       1.92      36.53        100            90           QP
          321.97       33.44     52.91     46        -12.56       14.78        2.3      36.55        100            90           QP
          389.87       36.89     54.12     46         -9.11       16.89       2.58      36.7         100            90           QP
          576.11       25.16     39.5      46        -20.84       19.72       3.12      37.18        100            90           QP

        REMARKS:        1. Peak detector quick scan is showed on the graph and final quasi-peak detector data is
                           measured corresponding to relevant limit and recorded in the data table.
                        2. Negative sign (-) in the margin column signify levels below the limit.
                        3. Frequency range scanned: 30MHz to 1000MHz.
                        4. Only emissions significantly above equipment noise floor are reported.




                                      No.B102, Dazu Chuangxin Mansion, North of Beihuan      Tel: +86 755 8869 6566
BV 7Layers Communications
                                      Avenue, North Area, Hi-Tech Industrial Park, Nanshan   Fax: +86 755 8869 6577
Technology (Shenzhen) Co. Ltd
                                      District, Shenzhen51800, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                          Page 26 of 30                                                  Report Version 1


                       Test Report No.: FV190322W004

                                Data trasmission
        TEST VOLTAGE                                               FREQUENCY RANGE                  30-1000 MHz
                                Input 120 Vac, 60 Hz
                                                                   DETECTOR FUNCTION
        ENVIRONMENTAL
                      23deg. C, 70 %RH                             & RESOLUTION                     Quasi-Peak, 120 kHz
        CONDITIONS
                                                                   BANDWIDTH

        TESTED BY               Rose Ma


                                ANTENNA POLARITY & TEST DISTANCE: VERTICAL AT 3 M
                    EMISSION READ                              ANTENNA CABLE PREAMP ANTENNA TABLE
           FREQ.                      LIMIT  MARGIN
                     LEVEL   LEVEL                              FACTOR   LOSS FACTOR HEIGHT  ANGLE REMARK
           (MHz)                    (dBuV/m)  (dB)
                    (dBuV/m) (dBuV)                              (dB /m)  (dB)  (dB)  (cm)  (Degree)
          71.71        23.75     52.07     40       -16.25      7.72      1.2     37.24      100    216       QP
         102.75        22.79     48.79    43.5      -20.71      9.65     1.33     36.98      100    216       QP
         199.75        26.63     50.58    43.5      -16.87      10.8     1.79     36.54      100    216       QP
         351.07        23.55     41.96     46       -22.45     15.78     2.42     36.61      100    216       QP
         417.03        30.94     47.48     46       -15.06     17.54     2.68     36.76      100    216       QP
         517.91        31.27     46.31     46       -14.73     18.95     3.02     37.01      100    216       QP
        REMARKS:        1. Peak detector quick scan is showed on the graph and final quasi-peak detector data is
                           measured corresponding to relevant limit and recorded in the data table.
                        2. Negative sign (-) in the margin column signify levels below the limit.
                        3. Frequency range scanned: 30MHz to 1000MHz.
                        4. Only emissions significantly above equipment noise floor are reported.




                                      No.B102, Dazu Chuangxin Mansion, North of Beihuan      Tel: +86 755 8869 6566
BV 7Layers Communications
                                      Avenue, North Area, Hi-Tech Industrial Park, Nanshan   Fax: +86 755 8869 6577
Technology (Shenzhen) Co. Ltd
                                      District, Shenzhen51800, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                          Page 27 of 30                                                  Report Version 1


                       Test Report No.: FV190322W004

                                   Data trasmission
        TEST VOLTAGE                                               FREQUENCY RANGE                 1-18 GHz
                                   Input 120 Vac, 60 Hz
                                                                   DETECTOR FUNCTION
        ENVIRONMENTAL
                                   23deg. C, 70 %RH                & RESOLUTION                    Peak/Average, 1 MHz
        CONDITIONS
                                                                   BANDWIDTH
        TESTED BY                  Rose Ma


                                ANTENNA POLARITY & TEST DISTANCE: HORIZONTAL AT 3 M
                    EMISSION READ                             ANTENNA CABLE PREAMP ANTENNA TABLE
           FREQ.                      LIMIT  MARGIN
                     LEVEL   LEVEL                             FACTOR   LOSS FACTOR HEIGHT  ANGLE REMARK
           (MHz)                    (dBuV/m)  (dB)
                    (dBuV/m) (dBuV)                             (dB /m)  (dB)  (dB)  (cm)  (Degree)
          2547         33.22     41.23     54       -20.78     33.31     5.05     46.37      100    261    Average
          2547         46.56     54.57     74       -27.44     33.31     5.05     46.37      100    261      Peak
          3278         38.5      44.97     54        -15.5     34.18     5.73     46.38      100    264    Average
          3278         45.99     52.46     74       -28.01     34.18     5.73     46.38      100    264      Peak
          4332         39.61     44.18     54       -14.39     36.24     5.58     46.39      100    197 Average
          4332         50.6      55.17     74       -23.40     36.24     5.58     46.39      100    197      Peak
        REMARKS:        1. Peak detector quick scan is showed on the graph and final quasi-peak detector data is
                           measured corresponding to relevant limit and recorded in the data table.
                        2. Negative sign (-) in the margin column signify levels below the limit.
                        3. Frequency range scanned: 1GHz to 18GHz.
                        4. Only emissions significantly above equipment noise floor are reported.




                                     No.B102, Dazu Chuangxin Mansion, North of Beihuan      Tel: +86 755 8869 6566
BV 7Layers Communications
                                     Avenue, North Area, Hi-Tech Industrial Park, Nanshan   Fax: +86 755 8869 6577
Technology (Shenzhen) Co. Ltd
                                     District, Shenzhen51800, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                         Page 28 of 30                                                  Report Version 1


                       Test Report No.: FV190322W004

                                  Data trasmission
        TEST VOLTAGE                                               FREQUENCY RANGE                 1-18 GHz
                                  Input 120 Vac, 60 Hz
                                                                   DETECTOR FUNCTION
        ENVIRONMENTAL
                                  23deg. C, 70 %RH                 & RESOLUTION                    Peak/Average, 1 MHz
        CONDITIONS
                                                                   BANDWIDTH
        TESTED BY                 Rose Ma


                                ANTENNA POLARITY & TEST DISTANCE: VERTICAL AT 3 M
                    EMISSION READ                             ANTENNA CABLE PREAMP ANTENNA TABLE
           FREQ.                      LIMIT  MARGIN
                     LEVEL   LEVEL                             FACTOR   LOSS FACTOR HEIGHT  ANGLE REMARK
           (MHz)                    (dBuV/m)  (dB)
                    (dBuV/m) (dBuV)                             (dB /m)  (dB)  (dB)  (cm)  (Degree)
           2868         33      41.27     54        -21.00       32.72       5.38      46.37        100            148       Average
           2868        44.67    52.94     74        -29.33       32.72       5.38      46.37        100            148        Peak
           3472        36.64    43.78     54        -17.36       33.37       5.87      46.38        100            274       Average
           3472        45.22    52.36     74        -28.78       33.37       5.87      46.38        100            274        Peak
           4635        37.28    41.59     54        -16.72       35.98        6.1      46.39        100            298       Average
           4635        49.67    53.98     74        -24.33       35.98        6.1      46.39        100            298        Peak

        REMARKS:        1. Peak detector quick scan is showed on the graph and final quasi-peak detector data is
                           measured corresponding to relevant limit and recorded in the data table.
                        2. Negative sign (-) in the margin column signify levels below the limit.
                        3. Frequency range scanned: 1GHz to 18GHz.
                        4. Only emissions significantly above equipment noise floor are reported.




                                     No.B102, Dazu Chuangxin Mansion, North of Beihuan      Tel: +86 755 8869 6566
BV 7Layers Communications
                                     Avenue, North Area, Hi-Tech Industrial Park, Nanshan   Fax: +86 755 8869 6577
Technology (Shenzhen) Co. Ltd
                                     District, Shenzhen51800, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                         Page 29 of 30                                                   Report Version 1


                       Test Report No.: FV190322W004


         3 APPENDIX A – MODIFICATIONS RECORDERS FOR ENGINEERING
           CHANGES TO THE EUT BY THE LAB

       No any modifications were made to the EUT by the lab during the test.




       ---END---




                                   No.B102, Dazu Chuangxin Mansion, North of Beihuan      Tel: +86 755 8869 6566
BV 7Layers Communications
                                   Avenue, North Area, Hi-Tech Industrial Park, Nanshan   Fax: +86 755 8869 6577
Technology (Shenzhen) Co. Ltd
                                   District, Shenzhen51800, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                       Page 30 of 30                                                  Report Version 1



Document Created: 2019-04-24 10:30:33
Document Modified: 2019-04-24 10:30:33

© 2024 FCC.report