ANNEX I Dipole Calibration Certificate
750 MHz Dipole Calibration Certificate


m                      geivenm ncrrone na wi2 urze                                    mt t n n n n n n n n n           n ns
                       Shenzhen Academy of Information
                       and Communications Technology




    Calibration Laboratory of                                    {x“gvj‘/”z;      g Schweizerischer Kalibrierdienst
    Schmid & Partner                                            m                 c    Service suisse d‘étalonnage
      Engineering AG                                            Ty                     Servizio svizzero di taratura
    Zeughausstrasse 43, 8004 Zurich, Switzerland                ‘//,,,7,\\\\0\?   S    swiss Calibration Service
                                                                    Ubale


    Accredited by the Swiss Accreditation Service (SAS)                            Accreditation No.: SCS 0108
    The Swiss Accreditation Service is one of the signatories to the EA
    Multilateral Agreement for the recognition of calibration certificates

    Glossary:
    TSL                           tissue simulating liquid
    ConvF                         sensitivity in TSL / NORM x,y,z
    N/A                           not applicable or not measured

    Calibration is Performed According to the Following Standards:
       a) IEEE Std 1528—2013, "IEEE Recommended Practice for Determining the Peak Spatial—
          Averaged Specific Absorption Rate (SAR) in the Human Head from Wireless
           Communications Devices: Measurement Techniques", June 2013
       b) IEC 62209—1, "Procedure to measure the Specific Absorption Rate (SAR) for hand—held
           devices used in close proximity to the ear (frequency range of 300 MHz to 3 GHz)®,
           February 2005
       0) 1EC 62209—2, "Procedure to determine the Specific Absorption Rate (SAR) for wireless
           communication devices used in close proximity to the human body (frequency range of 30
           MHz to 6 GHz)®, March 2010
        d)   KDB 865664, "SAR Measurement Requirements for 100 MHz to 6 GHz"

    Additional Documentation:
       e) DASY4/5 System Handbook
    Methods Applied and Interpretation of Paraméters:
         Measurement Conditions: Further details are available from the Validation Report at the end
         of the certificate. All figures stated in the certificate are valid at the frequency indicated.
         Antenna Parameters with TSL: The dipole is mounted with the spacer to position its feed
         point exactly below the center marking of the flat phantom section, with the arms oriented
         parallel to the body axis.
         Feed Point Impedance and Return Loss: These parameters are measured with the dipole
         positioned under the liquid filled phantom. The impedance stated is transformed from the
         measurement at the SMA connector to the feed point. The Return Loss ensures low
         reflected power. No uncertainty required.
         Electrical Delay: One—way delay between the SMA connector and the antenna feed point.
         No uncertainty required.
         SAR measured: SAR measured at the stated antenna input power.
         SAR normalized: SAR as measured, normalized to an input power of 1 W at the antenna
         connector.
         SAR for nominal TSL parameters: The measured TSL parameters are used to calculate the
         nominal SAR result.
      The reported uncertainty of measurementis stated as the standard uncertainty of measurement
      multiplied by the coverage factor k=2, which for a normal distribution corresponds to a coverage
      probatbility of approximately 95%.




    Certificate No: D750V3—1163_Sep16                               Page 2 of 8


2A IUCI
                 geivenm ncrrone na wi2 urze
                 Shenzhen Academy of Information
                 and Communications Technology                                                    ns      n e       <n >




  Measurement Conditions
     DASY system configuration, as far as not given on page 1.
      DASY Version                                             DASY5                                 V52.8.8
       Extrapolation                                   Advanced Extrapolation
       Phantom                                          Modular Flat Phantom
       Distance Dipole Center — TSL                              15 mm                             with Spacer

       Zoom Scan Resolution                              dx, dy, dz =5 mm
       Frequency                                          750 MHz 1 MHz



  Head TSL parameters
     The following parameters and calculations were applied.
                                                                 Temperature       Permittivity         Conductivity
       Nominal Head TSL parameters                                  22.0 °C           41.9               0.89 mho/m
       Measured Head TSL parameters                              (22.0 + 0.2) °C   41.0 £6 %          0.91 mho/m x 6 %

       Head TSL temperature change during test                      <0.5 °C            en                      en


  SAR result with Head TSL

       SAR averaged over 1 cm* (1 g) of Head TSL                  Condition
       SAR measured                                        250 mW input power                     2.11 Wikg

       SAR for nominal Head TSL parameters                     normalized to 1W         8.26 Wikg 2 17.0 % (k=2)

       SAR averaged over 10 cm* (10 g) of Head TSL                condition
       SAR measured                                        250 mW input power                  1.38 Wikg
       SAR for nominal Head TSL parameters                     normalized to 1W         5.43 Wikg 2 16.5 %(k=2)


  Body TSL parameters
     The following parameters and calculations were applied.
                                                                 Temperature       Permittivity         Conductivity
       Nominal Body TSL parameters                                  22.0 °C           55.5               0.96 mho/m
       Measured Body TSL parameters                              (22.0 £ 0.2) °C   54.9 2 6 %         0.99 mho/m + 6 %
       Body TSL temperature change during test                      <0.5 °C            —~—                     en


  SAR result with Body TSL

       SAR averaged over 1 cm‘ (1 g) of Body TSL                  Condition

       SAR measured                                        250 mW input power                     2.20 Wikg
       SAR for nominal Body TSL parameters                     normalized to 1W         8.58 W/kg 2 17.0 % (k=2)


       SAR averaged over 10 cm* (10 g) of Body TSL                 condition
        SAR measured                                       250 mW input power                     144 Wikg

        SAR for nominal Body TSL parameters                    normalized to 1W         5.64 Wikg £ 16.5 % (k=2)



  Certificate No: D750V3—1163_Sep16                     Page 3 of 8


=                    geivenm ncrrone na wi2 urze
                     Shenzhen Academy of Information
                     and Communications Technology                                                     nego     n en en >




    Appendix (Additional assessments outside the scope of SCS 0108)

    Antenna Parameters with Head TSL

          Impedance, transformed to feed point                                           54.5 Q — 1.8 jQ
          Return Loss                                                                       ~26.8 dB



    Antenna Parameters with Body TSL

          Impedance, transformed to feed point                                           49.8 0 — 3.5 jQ
          Return Loss                                                                      —29.0 dB




    General Antenna Parameters and Design

         [ Electrical Delay (one direction)                                                 1.032 ns
    After long term use with 100W radiated power, only a slight warming of the dipole near the feedpoint can be measured.

    The dipole is made of standard semirigid coaxial cable. The center conductor of the feeding line is directly connected to the
    second arm of the dipole. The antenna is therefore short—circuited for DC—signals. On some of the dipoles, small end caps
    are added to the dipole arms in order to improve matching when loaded according to the position as explained in the
    "Measurement Conditions" paragraph. The SAR data are not affected by this change. The overall dipole length is still
    according to the Standard.
    No excessiveforce must be applied to the dipole arms, because they might bend or the soldered connections nearthe
    feedpoint may be damaged.


    Additional EUT Data

          Manufactured by                                                                    SPEAG
          Manufactured on                                                                June 23, 2016




    Certificate No: D750V3—1163_Sep16                        Page 4 of 8


                 en im one n wz urvu                                         —
                 Shenthen Academy of Information
                 and Communications Technology




DASY5 Validation Report for Head TSL

                                                                                      Date: 19.09.2016
Test Laboratory: SPEAG, Zurich, Switzerland

DUT: D750V3 — SN1163; Type: D750V3; Serial: SN1163

Communication System: UID 0 — CW; Frequency: 750 MHz
Medium parameters used: f = 750 MHz; 0 = 0.91 S/m; &; =41; p = 1000 kg/m3
Phantom section: Flat Section
Measurement Standard: DASY5 (IEEE/IEC/ANSI C63.19—2011)

DASYS52 Configuration:

   *    Probe: EX3DV4 — SN7349; ConvF(10.07, 10.07, 10.07); Calibrated: 15.06.2016;

   *    Sensor—Surface: 1.4mm (Mechanical Surface Detection)

   *    Electronics: DAE4 Sn601; Calibrated: 30.12.2015

   *    Phantom: Flat Phantom 4.9L; Type: QDOOOP49AA; Serial: 1001

   «_   DASY52 52.8.8(1258); SEMCAD X 14.6.10(7372)


Dipole Calibration for Head Tissue/Pin=250 mW, d=15mm/Zoom Scan (7x7x7)/Cube 0:
Measurement grid: dx=5mm, dy=5mm, dz=5mm
Reference Value = 58.31 V/m; Power Drift = 0.01 dB
Peak SAR (extrapolated) = 3.16 W/kg
SAR(I g) =2.11 W/kg; SAR(10 g) = 1.38 W/kg
Maximum value of SAR (measured) = 2.79 W/kg


        dB
        0

        —2.00

        —4.00

        —6.00

        —8.00

        —10.00
                     0 dB = 2.79 W/kg = 4.46 dBW/kg




Certificate No: D750V3—1163_Sep16                  Page 5 of 8


                revomnmcrenace naw 12 urve
                Shenzhen Academy of Information
                and Communications Technology
                                                                                                         ty —




Impedance Measurement Plot for Head TSL




                                                                            19 Sep 2016   12:00:36
          CH] s1        i uofs                41 54.461 0   —1.7734 n 119.66 pF           750.000 000 MHz



          De1

          Ca




          Av
          16°

          H1d

          CH2




          Ca




          Ay
          16


          HLd

                     START $50.000 006 MHz                                        STOP 950,000 006 MHz




Certificate No: D750V3—1163_Sep16                             Page 6 of 8


m                   geivenm ncrrone na wi2 urze                                mt t n n n n n n n n n   n ns
                    Shenzhen Academy of Information
                    and Communications Technology




    DASY5 Validation Report for Body TSL

                                                                                         Date: 19.09.2016

    Test Laboratory: SPEAG, Zurich, Switzerland

    DUT: D750V3 — SN1163; Type: D750V3; Serial: SN1163

    Communication System: UID 0 — CW; Frequency: 750 MHz
    Medium parameters used: f= 750 MHz; 0 = 0.99 S/m; &, = 54.9; p = 1000 kg/m3
    Phantom section: Flat Section
    Measurement Standard: DASYS (IEEE/IEC/ANSI C63.19—2011)

    DASYS52 Configuration:

       *    Probe: EX3DV4 — SN7349; ConvF(9.99, 9.99, 9.99); Calibrated: 15.06.2016;

       *    Sensor—Surface: 1.4mm (Mechanical Surface Detection)

       +    Electronics: DAE4 Sn601; Calibrated: 30.12.2015

       +    Phantom: Flat Phantom 4.9L; Type: QDOOOP49AA; Serial: 1001

       «_   DASY52 52.8.8(1258); SEMCAD X 14.6.10(7372)


    Dipole Calibration for Body Tissue/Pin=250 mW, d=15mm/Zoom Scan (7x7x7)/Cube 0:
    Measurementgrid: dx=5mm, dy=Smm, dz=5mm
    Reference Value = 57.12 V/m; Power Drift = —0.00 dB
    Peak SAR (extrapolated) = 3.33 W/kg
    SAR(I g) = 2.2 W/kg; SAR(10 g) = 1.44 W/kg         e
    Maximum value of SAR (measured) = 2.94 W/kg

            dB
             0

            ~2.20

            ~4.40

            —6.60




            11.00
                       0 dB = 2.94 W/kg = 4.68 dBW/kg




    Certificate No: D750V3—1163_Sep16                 Page 7 of 8


                ancoiivmronaee ie wz wrvu                                                                     —
                Shenzhen Academy of Information
                and Communications Technology
                                                                                                                  ~v




Impedance Measurement Plot for Body TSL




                                                                                19 Sep zei6 es:or:is
                si1     4 uo rs                   41 49.754 a      —3.5410 0. 59.928 pF     750.000 000 MHz

         *

          De1
                                                                                         \
          Ca
                                                                      i /“\   &
                                              t            1              Sm —]
                                                                                             4
                                                                                            #
          fvg                                                             \
          16"                                                                 FnnpBs

          Hid
          CH2   $11      LQG         _5 dB/REF         —20 4B         .          11—28.958 dB    7'52.889 000 MHz




          Ca


                           ;         4             +           }                 +      4         }       ;
                           +         +             +           +                 +       +        +       +

                           +         +             +           4                 +       +        +       +

          Hid              +         i             }           +      +          £       }        +       4

                      START 550.000 000 MHz                                      —      StoP sse.000 006 MHz




Certificate No: D750V3—1163_Sep16                                   Page 8 of 8


                                         No.B18N00594-SAR
                                          Page 165 of 224

835 MHz Dipole Calibration Certificate


No.B18N00594-SAR
 Page 166 of 224


No.B18N00594-SAR
 Page 167 of 224


No.B18N00594-SAR
 Page 168 of 224