Test Report_DXX_ANT+_R2

FCC ID: 2AJOTTA-1087

Test Report

Download: PDF
FCCID_4157254

                                                               FCC Test Report

                       Report No.: RF180523C09-8 R1

                            FCC ID: 2AJOTTA-1087

                       Test Model: TA-1087

                 Received Date: May 23, 2018

                         Test Date: Jun. 11, 2018 ~ Jun. 19, 2018

                     Issued Date: Oct. 24, 2018


                         Applicant: HMD Global Oy

                          Address: Bertel Jungin aukio 9, 02600 Espoo, Finland



                        Issued By: Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch

                    Lab Address: No. 47-2, 14th Ling, Chia Pau Vil., Lin Kou Dist., New Taipei City, Taiwan
                                 ( R.O.C )
             Test Location (1): No.19, Hwa Ya 2nd Rd., Wen Hwa Vil., Kwei Shan Dist., Taoyuan City
                                33383, Taiwan, R.O.C.
             Test Location (2): No.215, Sec. 3, Beixin Rd., Xindian Dist., New Taipei City 231, Taiwan,
                                R.O.C
            FCC Registration /
                                            427177 / TW0011
       Designation Number:




This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted
only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this
report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product
unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you
provided to us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence, provided,
however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time
shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Unless specific
mention, the uncertainty of measurement has been explicitly taken into account to declare the compliance or non-compliance to the specification. The report
must not be used by the client to claim product certification, approval, or endorsement by TAF or any government agencies.


Report No.: RF180523C09-8 R1                          Page No. 1 / 27                                                           Report Format Version: 6.1.1
Cancels and replaces the report no.: RF180523C09-8 dated on Jun. 28, 2018


                                                                Table of Contents
Release Control Record .................................................................................................................................. 3
1 Certificate of Conformity ........................................................................................................................... 4
2 Summary of Test Results ........................................................................................................................... 5
    2.1 Measurement Uncertainty ..................................................................................................................... 5
    2.2 Modification Record .............................................................................................................................. 5
3 General Information ................................................................................................................................... 6
    3.1 General Description of EUT .................................................................................................................. 6
    3.2 Description of Test Modes..................................................................................................................... 7
        3.2.1 Test Mode Applicability and Tested Channel Detail .................................................................... 8
    3.3 Description of Support Units ................................................................................................................. 9
        3.3.1 Configuration of System under Test ........................................................................................... 9
    3.4 General Description of Applied Standards ............................................................................................ 9
4 Test Types and Results ............................................................................................................................ 10
    4.1 Radiated Emission and Bandedge Measurement .............................................................................. 10
        4.1.1 Limits of Radiated Emission and Bandedge Measurement ..................................................... 10
        4.1.2 Test Instruments ........................................................................................................................ 11
        4.1.3 Test Procedures ........................................................................................................................ 12
        4.1.4 Deviation from Test Standard ................................................................................................... 12
        4.1.5 Test Set Up ............................................................................................................................... 13
        4.1.6 EUT Operating Conditions ........................................................................................................ 14
        4.1.7 Test Results .............................................................................................................................. 15
    4.2 Conducted Emission Measurement .................................................................................................... 20
        4.2.1 Limits of Conducted Emission Measurement ........................................................................... 20
        4.2.2 Test Instruments ....................................................................................................................... 20
        4.2.3 Test Procedures ........................................................................................................................ 20
        4.2.4 Deviation from Test Standard ................................................................................................... 21
        4.2.5 Test Setup ................................................................................................................................. 21
        4.2.6 EUT Operating Conditions ........................................................................................................ 21
        4.2.7 Test Results .............................................................................................................................. 22
    4.3 20 dB Bandwidth Measurement.......................................................................................................... 24
        4.3.1 Limits of 20 dB Bandwidth Measurement ................................................................................. 24
        4.3.2 Test Setup ................................................................................................................................. 24
        4.3.3 Test Instruments ....................................................................................................................... 24
        4.3.4 Test Procedure ......................................................................................................................... 24
        4.3.5 Deviation from Test Standard ................................................................................................... 24
        4.3.6 EUT Operating Conditions ........................................................................................................ 24
        4.3.7 Test Result ................................................................................................................................ 25
5 Pictures of Test Arrangements................................................................................................................ 26
Appendix – Information on the Testing Laboratories ................................................................................ 27




Report No.: RF180523C09-8 R1                          Page No. 2 / 27                                                      Report Format Version: 6.1.1
Cancels and replaces the report no.: RF180523C09-8 dated on Jun. 28, 2018


                                                Release Control Record


 Issue No.                   Description                                          Date Issued
 RF180523C09-8               Original Release                                     Jun. 28, 2018
 RF180523C09-8 R1            Revise applicant’s address                           Oct. 24, 2018




Report No.: RF180523C09-8 R1                          Page No. 3 / 27       Report Format Version: 6.1.1
Cancels and replaces the report no.: RF180523C09-8 dated on Jun. 28, 2018


1    Certificate of Conformity


             Product: Smart Phone

               Brand: NOKIA

         Test Model: TA-1087

     Sample Status: Production Unit

           Applicant: HMD Global Oy

           Test Date: Jun. 11, 2018 ~ Jun. 19, 2018

          Standards: 47 CFR FCC Part 15, Subpart C (Section 15.249)
                          ANSI C63.10: 2013



The above equipment has been tested by Bureau Veritas Consumer Products Services (H.K.) Ltd.,
Taoyuan Branch, and found compliance with the requirement of the above standards. The test record, data
evaluation & Equipment Under Test (EUT) configurations represented herein are true and accurate accounts
of the measurements of the sample’s RF characteristics under the conditions specified in this report.




      Prepared by :                                                         ,   Date:   Oct. 24, 2018
                                     Ivonne Wu / Supervisor




      Approved by :                                                         ,   Date:   Oct. 24, 2018
                                Dylan Chiou / Project Engineer




Report No.: RF180523C09-8 R1                          Page No. 4 / 27                       Report Format Version: 6.1.1
Cancels and replaces the report no.: RF180523C09-8 dated on Jun. 28, 2018


                                                                                                                   ooocc



2      Summary of Test Results

                                  47 CFR FCC Part 15, Subpart C (Section 15.249)

        FCC
                                    Test Item                       Result                     Remarks
       Clause
                                                                                Meet the requirement of limit.
       15.207       AC Power Conducted Emission                      Pass       Minimum passing margin is —14.75 dB
                                                                               at 0.17328 MHz.
                    Radiated Emission Test
       15.209       B.an.d Edge Measurement                                     Meet the requirement of limit.
       15.249       Limit: 50 dB less than the peak                  Pass       Minimum passing margin is —14.47 dB
      15.249 (d)    value of fundamental frequency or                           at 937 MHz.
                    meet radiated emission limit in
                    section 15.209
      15.215 (c)    20 dB Bandwidth                                  Pass       Meet the requirement of limit.


2.1      Measurement Uncertainty

Where relevant, the following measurement uncertainty levels have been estimated for tests performed on
the EUT as specified in CISPR 16—4—2:


                                                                                               Expended Uncertainty
                      Measurement                                        Frequenc
                                                                             quency                    (k=2) (4)
          Conducted Emissions at mains ports                        150 kHz ~ 30 MHz                    244 dB

                                                                    30 MHz ~ 200 MHz                  2.0153 dB
            Radiated Emissions up to 1 GHz
                                                                  200 MHz ~ 1000 MHz                  2.0224 dB
                                                                      1 GHz ~ 18 GHz                  1.0121 dB
            Radiated Emissions above 1 GHz
                                                                     18 GHz ~ 40 GHz                  1.1508 dB


2.2       Modification Record
There were no modifications required for compliance.




Report No.: RF180523C09—8 R1                           Page No. 5 / 27                           Report Format Version: 6.1.1
Cancels and replaces the report no.: RF1805230C09—8 dated on Jun. 28, 2018


3     General Information
3.1    General Description of EUT

 Product                           Smart Phone
 Brand                             NOKIA
 Test Model                        TA-1087
 Status of EUT                     Production Unit
                                   5.0 Vdc or 9 Vdc or 12 Vdc (adapter)
 Power Supply Rating               5.0 Vdc (host equipment)
                                   3.85 Vdc (Li-ion battery)
 Modulation Type                   GFSK
 Operating Frequency               2403 ~ 2480 MHz
 Number of Channel                 78
 Antenna Type                      PIFA antenna with -1.5 dBi gain
 Antenna Connector                 N/A
 Accessory Device                  Refer to Note as below
 Data Cable Supplied               Refer to Note as below
Note:
1. The EUT’s accessories list refers to Ext. Pho.
2. The above EUT information is declared by manufacturer and for more detailed features description,
   please refers to the manufacturer's specifications or user's manual.




Report No.: RF180523C09-8 R1                          Page No. 6 / 27              Report Format Version: 6.1.1
Cancels and replaces the report no.: RF180523C09-8 dated on Jun. 28, 2018


3.2    Description of Test Modes
78 channels are provided to this EUT:
  Channel       Freq. (MHz)       Channel       Freq. (MHz)       Channel   Freq. (MHz)   Channel      Freq. (MHz)
       1             2403             21             2423             41       2443         61             2463
       2             2404             22             2424             42       2444         62             2464
       3             2405             23             2425             43       2445         63             2465
       4             2406             24             2426             44       2446         64             2466
       5             2407             25             2427             45       2447         65             2467
       6             2408             26             2428             46       2448         66             2468
       7             2409             27             2429             47       2449         67             2469
       8             2410             28             2430             48       2450         68             2470
       9             2411             29             2431             49       2451         69             2471
      10             2412             30             2432             50       2452         70             2472
      11             2413             31             2433             51       2453         71             2473
      12             2414             32             2434             52       2454         72             2474
      13             2415             33             2435             53       2455         73             2475
      14             2416             34             2436             54       2456         74             2476
      15             2417             35             2437             55       2457         75             2477
      16             2418             36             2438             56       2458         76             2478
      17             2419             37             2439             57       2459         77             2479
      18             2420             38             2440             58       2460         78             2480
      19             2421             39             2441             59       2461
      20             2422             40             2442             60       2462




Report No.: RF180523C09-8 R1                          Page No. 7 / 27                      Report Format Version: 6.1.1
Cancels and replaces the report no.: RF180523C09-8 dated on Jun. 28, 2018


3.2.1       Test Mode Applicability and Tested Channel Detail

 EUT Configure                               Applicable To
                                                                                                      Description
     Mode             RE1G           RE<1G              PLC           APCM

        -                √               √                   √              √         -
               RE1G: Radiated Emission above 1 GHz &
Where                                                                 RE<1G: Radiated Emission below 1 GHz
               Bandedge Measurement
               PLC: Power Line Conducted Emission                     APCM: Antenna Port Conducted Measurement

NOTE: The EUT had been pre-tested on the positioned of each 3 axis. The worst case was found when positioned on Y-plane.


Radiated Emission Test (Above 1 GHz):

     Pre-Scan has been conducted to determine the worst-case mode from all possible combinations
     between available modulations, data rates and antenna ports (if EUT with antenna diversity architecture).
     Following channel(s) was (were) selected for the final test as listed below.
    EUT Configure Mode             Available Channel                 Tested Channel                    Modulation Type

               -                         1 to 78                        1, 39, 78                          GFSK


Radiated Emission Test (Below 1 GHz):

     Pre-Scan has been conducted to determine the worst-case mode from all possible combinations
     between available modulations, data rates and antenna ports (if EUT with antenna diversity architecture).
     Following channel(s) was (were) selected for the final test as listed below.
    EUT Configure Mode              Tested Channel                Modulation Technology                Modulation Type

               -                         1 to 78                                1                          GFSK


Power Line Conducted Emission Test:

     Pre-Scan has been conducted to determine the worst-case mode from all possible combinations
     between available modulations, data rates and antenna ports (if EUT with antenna diversity architecture).
     Following channel(s) was (were) selected for the final test as listed below.
    EUT Configure Mode              Tested Channel                Modulation Technology                Modulation Type

               -                         1 to 78                                1                          GFSK


Antenna Port Conducted Measurement:

     Pre-Scan has been conducted to determine the worst-case mode from all possible combinations
     between available modulations, data rates and antenna ports (if EUT with antenna diversity architecture).
     Following channel(s) was (were) selected for the final test as listed below.
    EUT Configure Mode              Tested Channel                Modulation Technology                Modulation Type

               -                         1 to 78                                1                          GFSK




Report No.: RF180523C09-8 R1                          Page No. 8 / 27                               Report Format Version: 6.1.1
Cancels and replaces the report no.: RF180523C09-8 dated on Jun. 28, 2018


                                                                                                             ooocc



Test Condition:
      Applicable To          Environmental Conditions                    Input Power          Tested By

         REz1G                   25 deg. C, 65 % RH                      120 Vac, 60 Hz      Charles Hsiao

         RE<1G                   25 deg. C, 65 % RH                      120 Vac, 60 Hz      Charles Hsiao

          PLC                    25 deg. C, 68 % RH                      120 Vac, 60 Hz      Jisyong Wang

         APCM                    25 deg. C, 68 % RH                          3.85 Vde         Carlos Chen



3.3      Description of Support Units

The EUT has been tested as an independent unit together with other necessary accessories or support units.


3.3.1      Configuration of System under Test

                                                w_




                                                        SS
                                                        EUT

                                               (Power from AC Adapter)



           *Test Table




3.4      General Description of Applied Standards

The EUT is a RF Product. According to the specifications of the manufacturer, it must comply with the
requirements of the following standards:


FCC Part 15, Subpart C (15.249)
ANSI C63.10—2013


All test items have been performed and recorded as per the above standards.




Report No.: RF180523C09—8 R1                           Page No. 9 / 27                    Report Format Version: 6.1.1
Cancels and replaces the report no.: RF1805230C09—8 dated on Jun. 28, 2018


4     Test Types and Results
4.1     Radiated Emission and Bandedge Measurement
4.1.1     Limits of Radiated Emission and Bandedge Measurement

The field strength of emissions from intentional radiators operated within these frequency bands shall comply
with the following
                                             Field Strength of Fundamental   Field Strength of Harmonics
        Fundamental Frequency
                                                    (millivolts/meter)            (microvolts/meter)
            902 ~ 928 MHz                                      50                          500
          2400 ~ 2483.5 MHz                                    50                          500
           5725 ~ 5875 MHz                                     50                          500
            24 ~ 24.25 GHz                                    250                         2500


Emissions radiated outside of the specified frequency bands, except for harmonics, shall be attenuated by at
least 50 dB below the level of the fundamental or to the general radiated emission limits as below table,
whichever is the lesser attenuation
             Frequencies                              Field Strength           Measurement Distance
                (MHz)                               (microvolts/meter)               (meters)
             0.009 ~ 0.490                              2400/F (kHz)                      300
             0.490 ~ 1.705                             24000/F (kHz)                       30
             1.705 ~ 30.0                                     30                           30
                30 ~ 88                                      100                            3
                88 ~ 216                                     150                            3
               216 ~ 960                                     200                            3
              Above 960                                      500                            3
Note:
1. The lower limit shall apply at the transition frequencies.
2. Emission level (dBuV/m) = 20 log Emission level (uV/m).
3. For frequencies above 1000 MHz, the field strength limits are based on average detector, however, the
   peak field strength of any emission shall not exceed the maximum permitted average limits, specified
   above by more than 20dB under any condition of modulation.




Report No.: RF180523C09-8 R1                          Page No. 10 / 27                 Report Format Version: 6.1.1
Cancels and replaces the report no.: RF180523C09-8 dated on Jun. 28, 2018


4.1.2    Test Instruments

        Description &                                                         Date of               Due Date of
                                     Model No.                Serial No.
        Manufacturer                                                         Calibration            Calibration
Test Receiver
                                       N9038A               MY52260177      Jul. 05, 2017           Jul. 04, 2018
Agilent Technologies
Spectrum Analyzer
                                        FSU43                   101261      Jan. 11, 2018          Jan. 10, 2019
ROHDE & SCHWARZ
Double Ridge Guide Horn
                                         3115                    5619       Nov. 30, 2017          Nov. 29, 2018
Antenna EMCO
BILOG Antenna
                                     VULB 9168                 9168-153     Dec. 06, 2017          Dec. 05, 2018
SCHWARZBECK
Fixed Attenuator
                                    BW-N10W5+                     NA        Jul. 07, 2017           Jul. 06, 2018
Mini-Circuits
Loop Antenna                          EM-6879                     269       Aug. 11, 2017          Aug. 10, 2018
Preamplifier
                                         310N                   187226      Jun. 23, 2017          Jun. 22, 2018
Agilent
Preamplifier
                                       83017A               MY39501357      Jun. 23, 2017          Jun. 22, 2018
Agilent
Power Meter
                                      ML2495A                  1012010      Aug. 15, 2017          Aug. 14, 2018
Anritsu
Power Sensor
                                      MA2411B                  1315050      Aug. 15, 2017          Aug. 14, 2018
Anritsu
                                                         Cable-CH1-01(RFC
RF signal cable                                           -SMS-100-SMS-12
                                        5D-FB                               Jun. 26, 2017          Jun. 25, 2018
ETS-LINDGREN                                             0+RFC-SMS-100-S
                                                              MS-400)
RF signal cable                                          Cable-CH1-02(RFC
                                        8D-FB                               Jun. 26, 2017          Jun. 25, 2018
ETS-LINDGREN                                             -SMS-100-SMS-24)
Boresight Antenna Fixture              FBA-01                 FBA-SIP01          NA                       NA
Software                                 E3
                                                                  NA             NA                       NA
BV ADT                               8.130425b
Antenna Tower
                                          NA                      NA             NA                       NA
MF
Turn Table
                                          NA                      NA             NA                       NA
MF
Antenna Tower &Turn
Table Controller                      MF-7802                     NA             NA                       NA
MF


Note: 1. The calibration interval of the above test instruments is 12 months and the calibrations are
         traceable to NML/ROC and NIST/USA.
        2. The test was performed in HsinTien Chamber 1.
        3. The horn antenna and preamplifier (model: 83017A) are used only for the measurement of
           emission frequency above 1GHz if tested.
        4. The IC Site Registration No. is IC7450I-1.




Report No.: RF180523C09-8 R1                          Page No. 11 / 27                      Report Format Version: 6.1.1
Cancels and replaces the report no.: RF180523C09-8 dated on Jun. 28, 2018


4.1.3    Test Procedures

For Radiated Emission below 30 MHz
a. The EUT was placed on the top of a rotating table 0.8 meters above the ground at a 3 meter chamber
     room. The table was rotated 360 degrees to determine the position of the highest radiation.
b. The EUT was set 3 meters away from the interference-receiving antenna, which was mounted on the top
     of a variable-height antenna tower.
c. Both Parallel, perpendicular, and ground-parallel orientations of the antenna are set to make the
     measurement.
d. For each suspected emission, the EUT was arranged to its worst case and the rotatable table was turned
     from 0 degrees to 360 degrees to find the maximum reading.
e. The test-receiver system was set to Quasi-Peak Detect Function and Specified Bandwidth with Maximum
     Hold Mode.
Note:
1. The resolution bandwidth and video bandwidth of test receiver/spectrum analyzer is 9 kHz at frequency
     below 30 MHz.


For Radiated Emission above 30 MHz
a. The EUT was placed on the top of a rotating table 0.8 meters (for 30 MHz ~ 1 GHz) / 1.5 meters (for
     above 1 GHz) above the ground at 3 meter chamber room for test. The table was rotated 360 degrees to
     determine the position of the highest radiation.
b. The EUT was set 3 meters away from the interference-receiving antenna, which was mounted on the top
     of a variable-height antenna tower.
c. The height of antenna is varied from one meter to four meters above the ground to determine the
     maximum value of the field strength. Both horizontal and vertical polarizations of the antenna are set to
     make the measurement.
d. For each suspected emission, the EUT was arranged to its worst case and then the antenna was tuned to
     heights from 1 meter to 4 meters and the rotatable table was turned from 0 degrees to 360 degrees to find
     the maximum reading.
e. The test-receiver system was set to quasi-peak detect function and specified bandwidth with maximum
     hold mode when the test frequency is below 1 GHz.
f.   The test-receiver system was set to peak and average detected function and specified bandwidth with
     maximum hold mode when the test frequency is above 1 GHz. If the peak reading value also meets
     average limit, measurement with the average detector is unnecessary.
Note:
1. The resolution bandwidth and video bandwidth of test receiver/spectrum analyzer is 120 kHz for
     Quasi-peak detection (QP) at frequency below 1 GHz.
2. The resolution bandwidth of test receiver/spectrum analyzer is 1 MHz and the video bandwidth is 3 MHz
     for Peak detection (PK) at frequency above 1 GHz.
3. The resolution bandwidth of test receiver/spectrum analyzer is 1 MHz and the video bandwidth is ≥ 1/T
     (Duty cycle < 98 %) or 10 Hz (Duty cycle ≥ 98 %) for Average detection (AV) at frequency above 1 GHz.
     (RBW = 1 MHz, VBW = 10 Hz)
4. All modes of operation were investigated and the worst-case emissions are reported.


4.1.4    Deviation from Test Standard

No deviation.


Report No.: RF180523C09-8 R1                          Page No. 12 / 27                  Report Format Version: 6.1.1
Cancels and replaces the report no.: RF180523C09-8 dated on Jun. 28, 2018


4.1.5    Test Set Up
  <Radiated Emission below 30 MHz>


                                                                                   1m
             EUT&                                   3m
             Support Units

                                        Turn Table

                80 cm


                                                 Ground Plane
                                                 Test Receiver




  <Radiated Emission 30 MHz to 1 GHz>

                                                                      Ant. Tower
                                                                                    1-4m
                                                                                    Variable
                                                     3m
                                                      10m
               EUT&
               Support Units

                                              Turn Table

                   80cm


                                                    Ground Plane

                                                    Test Receiver




Report No.: RF180523C09-8 R1                          Page No. 13 / 27                  Report Format Version: 6.1.1
Cancels and replaces the report no.: RF180523C09-8 dated on Jun. 28, 2018


  <Radiated Emission above 1 GHz>



                                                                   Ant. Tower      1-4 m
                                                                                   Variable
             EUT&                                   3m
             Support Units

                                        Turn Table
                                                          Absorber

                150 cm


                                                 Ground Plane
                                                 Test Receiver




For the actual test configuration, please refer to the attached file (Test Setup Photo).


4.1.6    EUT Operating Conditions

Set the EUT under transmission condition continuously at specific channel frequency.




Report No.: RF180523C09-8 R1                          Page No. 14 / 27                     Report Format Version: 6.1.1
Cancels and replaces the report no.: RF180523C09-8 dated on Jun. 28, 2018


4.1.7     Test Results
Above 1 GHz WORST-CASE DATA:
EUT Test Condition                                            Measurement Detail
Channel                       Channel 1                       Frequency Range               1 GHz ~ 25 GHz
                                                                                            Peak (PK)
Input Power                   120 Vac, 60 Hz                  Detector Function
                                                                                            Average (AV)
Environmental
                              25 deg. C, 65 % RH              Tested By                     Charles Hsiao
Conditions


                                  Antenna Polarity & Test Distance: Horizontal at 3 m
            Emission      Read                             Antenna                 Preamp   Antenna        Table
Frequency                              Limit    Margin                  Cable
              Level       Level                             Factor                 Factor    Height       Angle      Remark
  (MHz)                              (dBuV/m)    (dB)                 Loss (dB)
            (dBuV/m)     (dBuV)                             (dB/m)                  (dB)      (cm)       (Degree)
   2374       33.81       32.15         54       -20.19      31.78          5.37   35.49      207           155      Average
   2374       55.83       54.17         74       -18.17      31.78          5.37   35.49      207           155        Peak
   2403       60.64        58.9         94       -33.36      31.81          5.4    35.47      207           155      Average
   2403       82.66       80.92        114       -31.34      31.81          5.4    35.47      207           155        Peak
   2488       32.81        30.8         54       -21.19       31.9          5.53   35.42      207           155      Average
   2488       54.83       52.82         74       -19.17       31.9          5.53   35.42      207           155        Peak
                                   Antenna Polarity & Test Distance: Vertical at 3 m
            Emission      Read                             Antenna                 Preamp   Antenna        Table
Frequency                              Limit    Margin                  Cable
              Level       Level                             Factor                 Factor    Height       Angle      Remark
  (MHz)                              (dBuV/m)    (dB)                 Loss (dB)
            (dBuV/m)     (dBuV)                             (dB/m)                  (dB)      (cm)       (Degree)
   2366       33.57       31.93         54       -20.43      31.76          5.37   35.49      100           134      Average
   2366       55.59       53.95         74       -18.41      31.76          5.37   35.49      100           134        Peak
   2403       62.04        60.3         94       -31.96      31.81          5.4    35.47      100           134      Average
   2403       84.06       82.32        114       -29.94      31.81          5.4    35.47      100           134        Peak
   2484       34.32       32.36         54       -19.68      31.88          5.5    35.42      100           134      Average
   2484       56.34       54.38         74       -17.66      31.88          5.5    35.42      100           134        Peak

Remarks:
1. Emission Level = Read Level + Antenna Factor + Cable Loss - Preamp Factor
   Margin value = Emission level – Limit value
2. The average value of fundamental frequency is: Average = Peak value + 20log(Duty cycle) Where the duty
   factor is calculated from following formula:
   20 log (Duty cycle) = 20 log (0.1585 ms * 50 / 100 ms) = -22.02 dB
   Please refer to the plotted duty




Report No.: RF180523C09-8 R1                          Page No. 15 / 27                              Report Format Version: 6.1.1
Cancels and replaces the report no.: RF180523C09-8 dated on Jun. 28, 2018


EUT Test Condition                                            Measurement Detail
Channel                       Channel 39                      Frequency Range               1 GHz ~ 25 GHz
                                                                                            Peak (PK)
Input Power                   120 Vac, 60 Hz                  Detector Function
                                                                                            Average (AV)
Environmental
                              25 deg. C, 65 % RH              Tested By                     Charles Hsiao
Conditions


                               Antenna Polarity & Test Distance: Horizontal at 3 m
            Emission      Read                             Antenna                 Preamp   Antenna        Table
Frequency                             Limit     Margin                  Cable
              Level       Level                             Factor                 Factor    Height       Angle      Remark
  (MHz)                             (dBuV/m)     (dB)                 Loss (dB)
            (dBuV/m)     (dBuV)                             (dB/m)                  (dB)      (cm)       (Degree)
   2388         34        32.29        54         -20         31.8          5.4    35.49      207           155      Average
   2388       56.02       54.31        74        -17.98       31.8          5.4    35.49      207           155        Peak
   2441       60.69       58.82        94        -33.31      31.85          5.46   35.44      207           155      Average
   2441       82.71       80.84        114       -31.29      31.85          5.46   35.44      207           155        Peak
   2490       34.05       32.04        54        -19.95       31.9          5.53   35.42      207           155      Average
   2490       56.07       54.06        74        -17.93       31.9          5.53   35.42      207           155        Peak
                                  Antenna Polarity & Test Distance: Vertical at 3 m
            Emission      Read                             Antenna                 Preamp   Antenna        Table
Frequency                             Limit     Margin                  Cable
              Level       Level                             Factor                 Factor    Height       Angle      Remark
  (MHz)                             (dBuV/m)     (dB)                 Loss (dB)
            (dBuV/m)     (dBuV)                             (dB/m)                  (dB)      (cm)       (Degree)
   2360       32.99       31.36        54        -21.01      31.76          5.37    35.5      100           134      Average
   2360       55.01       53.38        74        -18.99      31.76          5.37    35.5      100           134        Peak
   2441       62.06       60.19        94        -31.94      31.85          5.46   35.44      100           134      Average
   2441       84.08       82.21        114       -29.92      31.85          5.46   35.44      100           134        Peak
   2498       33.73       31.71        54        -20.27       31.9          5.53   35.41      100           134      Average
   2498       55.75       53.73        74        -18.25       31.9          5.53   35.41      100           134        Peak

Remarks:
1. Emission Level = Read Level + Antenna Factor + Cable Loss - Preamp Factor
   Margin value = Emission level – Limit value
2. The average value of fundamental frequency is: Average = Peak value + 20log(Duty cycle) Where the duty
   factor is calculated from following formula:
   20 log (Duty cycle) = 20 log (0.1585 ms * 50 / 100 ms) = -22.02 dB
   Please refer to the plotted duty




Report No.: RF180523C09-8 R1                          Page No. 16 / 27                              Report Format Version: 6.1.1
Cancels and replaces the report no.: RF180523C09-8 dated on Jun. 28, 2018


EUT Test Condition                                            Measurement Detail
Channel                       Channel 78                      Frequency Range               1 GHz ~ 25 GHz
                                                                                            Peak (PK)
Input Power                   120 Vac, 60 Hz                  Detector Function
                                                                                            Average (AV)
Environmental
                              25 deg. C, 65 % RH              Tested By                     Charles Hsiao
Conditions


                                  Antenna Polarity & Test Distance: Horizontal at 3 m
            Emission      Read                             Antenna                 Preamp   Antenna        Table
Frequency                              Limit    Margin                  Cable
              Level       Level                             Factor                 Factor    Height       Angle      Remark
  (MHz)                              (dBuV/m)    (dB)                 Loss (dB)
            (dBuV/m)     (dBuV)                             (dB/m)                  (dB)      (cm)       (Degree)
   2390       32.94       31.21         54       -21.06       31.8          5.4    35.47      207           115      Average
   2390       54.96       53.23         74       -19.04       31.8          5.4    35.47      207           115        Peak
   2480       60.26        58.3         94       -33.74      31.88          5.5    35.42      207           115      Average
   2480       82.28       80.32        114       -31.72      31.88          5.5    35.42      207           115        Peak
   2492        33.4       31.38         54        -20.6       31.9          5.53   35.41      207           115      Average
   2492       55.42        53.4         74       -18.58       31.9          5.53   35.41      207           115        Peak
                                   Antenna Polarity & Test Distance: Vertical at 3 m
            Emission      Read                             Antenna                 Preamp   Antenna        Table
Frequency                              Limit    Margin                  Cable
              Level       Level                             Factor                 Factor    Height       Angle      Remark
  (MHz)                              (dBuV/m)    (dB)                 Loss (dB)
            (dBuV/m)     (dBuV)                             (dB/m)                  (dB)      (cm)       (Degree)
   2384       33.98       32.29         54       -20.02      31.78          5.4    35.49      100           134      Average
   2384         56        54.31         74        -18        31.78          5.4    35.49      100           134        Peak
   2480       62.01       60.05         94       -31.99      31.88          5.5    35.42      100           134      Average
   2480       84.03       82.07        114       -29.97      31.88          5.5    35.42      100           134        Peak
   2498       33.25       31.23         54       -20.75       31.9          5.53   35.41      100           134      Average
   2498       55.27       53.25         74       -18.73       31.9          5.53   35.41      100           134        Peak

Remarks:
1. Emission Level = Read Level + Antenna Factor + Cable Loss - Preamp Factor
   Margin value = Emission level – Limit value
2. The average value of fundamental frequency is: Average = Peak value + 20log(Duty cycle) Where the duty
   factor is calculated from following formula:
   20 log (Duty cycle) = 20 log (0.1585 ms * 50 / 100 ms) = -22.02 dB
   Please refer to the plotted duty




Report No.: RF180523C09-8 R1                          Page No. 17 / 27                              Report Format Version: 6.1.1
Cancels and replaces the report no.: RF180523C09-8 dated on Jun. 28, 2018


Below 1 GHz WORST-CASE DATA:
EUT Test Condition                                            Measurement Detail
Channel                       Channel 1                       Frequency Range               30 MHz ~ 1 GHz
                                                                                            Peak (PK)
Input Power                   120 Vac, 60 Hz                  Detector Function
                                                                                            Quasi-peak (QP)
Environmental
                              25 deg. C, 65 % RH              Tested By                     Charles Hsiao
Conditions


                                  Antenna Polarity & Test Distance: Horizontal at 3 m
            Emission      Read                             Antenna                 Preamp   Antenna        Table
Frequency                              Limit    Margin                  Cable
              Level       Level                             Factor                 Factor    Height       Angle      Remark
  (MHz)                              (dBuV/m)    (dB)                 Loss (dB)
            (dBuV/m)     (dBuV)                             (dB/m)                  (dB)      (cm)       (Degree)
   88.59       17.7       38.45        43.5       -25.8       9.95          1.11   31.81      172           115        Peak
  155.55      20.63       42.82        43.5      -22.87       8.56          1.52   32.27      196           34         Peak
  277.59       19.9       37.28         46        -26.1      12.71          2.03   32.12      176           224        Peak
   373.5      22.74       38.11         46       -23.26      14.51          2.26   32.14      184           117        Peak
   722.8      20.95       30.36         46       -25.05      19.54          3.16    32.11     156           224        Peak
    937       29.35       35.29         46       -16.65      21.65          3.62   31.21      163           219        Peak
                                   Antenna Polarity & Test Distance: Vertical at 3 m
            Emission      Read                             Antenna                 Preamp   Antenna        Table
Frequency                              Limit    Margin                  Cable
              Level       Level                             Factor                 Factor    Height       Angle      Remark
  (MHz)                              (dBuV/m)    (dB)                 Loss (dB)
            (dBuV/m)     (dBuV)                             (dB/m)                  (dB)      (cm)       (Degree)
   49.71      19.33        36.1         40       -20.67      14.55          0.9    32.22      187           115        Peak
   87.24      16.52       37.57         40       -23.48       9.7           1.11   31.86      186           263        Peak
  157.17      15.67       37.78        43.5      -27.83       8.64          1.52   32.27      123           107        Peak
   381.9      18.45       33.65         46       -27.55      14.63          2.34   32.17      112           175        Peak
   584.9      20.53        32.2         46       -25.47      17.71          2.82    32.2      140           286        Peak
    937       31.53       37.47         46       -14.47      21.65          3.62   31.21      186           350        Peak

Remarks:
1. Emission Level = Read Level + Antenna Factor + Cable Loss - Preamp Factor
   Margin value = Emission level – Limit value




Report No.: RF180523C09-8 R1                          Page No. 18 / 27                              Report Format Version: 6.1.1
Cancels and replaces the report no.: RF180523C09-8 dated on Jun. 28, 2018


                                            <Duty Cycle Correction Factor>
                             Duty Factor on time/100 ms (One Pulse) Plot on Channel 1




                            Duty Factor on time/100 ms (Count Pulse) Plot on Channel 1




                        20 log (Duty cycle) = 20 log (0.1585 ms * 50 / 100 ms) = -22.02 dB




Report No.: RF180523C09-8 R1                          Page No. 19 / 27                   Report Format Version: 6.1.1
Cancels and replaces the report no.: RF180523C09-8 dated on Jun. 28, 2018


4.2     Conducted Emission Measurement
4.2.1    Limits of Conducted Emission Measurement

                                                                  Conducted Limit (dBuV)
        Frequency (MHz)
                                                    Quasi-Peak                               Average
            0.15 - 0.5                                 66 - 56                                56 - 46
            0.50 - 5.0                                   56                                     46
            5.0 - 30.0                                   60                                     50
Note:
1. The lower limit shall apply at the transition frequencies.
2. The limit decreases in line with the logarithm of the frequency in the range of 0.15 to 0.50 MHz.


4.2.2    Test Instruments

        Description &                                                           Date of              Due Date of
                                     Model No.                Serial No.
        Manufacturer                                                           Calibration           Calibration
Test Receiver
                                         ESCI                    100613       Nov. 23, 2017          Nov. 22, 2018
ROHDE & SCHWARZ
RF signal cable (with
10dB PAD)                               5D-FB              Cable-cond1-01     Sep. 05, 2017          Sep. 04, 2018
Woken
LISN/AMN
ROHDE & SCHWARZ                       ESH3-Z5                 835239/001      Mar. 06, 2018          Mar. 05, 2019
(EUT)
LISN/AMN
ROHDE & SCHWARZ                       ESH3-Z5                    100311       Aug. 15, 2017          Aug. 14, 2018
(Peripheral)
Software                          BV ADT_Cond_
                                                                  NA               NA                      NA
ADT                                  V7.3.7.4

Note: 1. The calibration interval of the above test instruments is 12 months and the calibrations are traceable
         to NML/ROC and NIST/USA.
      2. The test was performed in HwaYa Shielded Room 1.
      3. The VCCI Site Registration No. is C-2040.


4.2.3    Test Procedures

a.    The EUT was placed 0.4 meters from the conducting wall of the shielded room with EUT being
      connected to the power mains through a line impedance stabilization network (LISN). Other support units
      were connected to the power mains through another LISN. The two LISNs provide 50 ohm/ 50 uH of
      coupling impedance for the measuring instrument.
b.    Both lines of the power mains connected to the EUT were checked for maximum conducted interference.
c.    The frequency range from 150 kHz to 30 MHz was searched. Emission levels under (Limit – 20 dB) was
      not recorded.


Note: The resolution bandwidth and video bandwidth of test receiver is 9 kHz for quasi-peak detection (QP)
and average detection (AV) at frequency 0.15 MHz - 30 MHz.




Report No.: RF180523C09-8 R1                          Page No. 20 / 27                       Report Format Version: 6.1.1
Cancels and replaces the report no.: RF180523C09-8 dated on Jun. 28, 2018


                                                                                                                 ommert
                                                                                                                 [vexiras)]



4.2.4    Deviation from Test Standard
No deviation.


4.2.5     Test Setup

                                        Vertical Ground
                                        Reference Plane                             / Test Receiver


                                        EUT                                           o o 0 o
                        40cm             U                                          i5 a o o




                                                               80cm
                         LISN
                                    L                 L                             L
                                                                             N                    T
                                                               \ Horizontal Ground
                                                                             Reference Plane

                          Note: 1.Support units were connected to second LISN.




 For the actual test configuration, please refer to the attached file (Test Setup Photo).


4.2.6    EUT Operating Conditions

Same as 4.1.6.




Report No.: RF180523C09—8 R1                           Page No. 21 / 27                        Report Format Version: 6.1.1
Cancels and replaces the report no.: RF1805230C09—8 dated on Jun. 28, 2018


                                                                                                                       3)
                                                                                                                   ommert




4.2.7    Test Results
                                                                 Detector Function &         .
                                                                        .              Quasi—Peak (QP) /
Frequency Range             150kHz ~ 30MHz                       Resolution
                                                                 Bandwidth             Average (AV), 9kHz

                                                                 Environmental           s
Input Power                 120Vac, 60Hz                         Conditions            25°C, 65%RH

Tested by                   Jisyong Wang                         Test Date             2018/6/14


                                                 Phase Of Power : Line (L)
         Frequency       |Correction|    Reading Value          Emission Level          Limit                Margin
 No                         Factor           (dBuV)                  (dBuV)            (dBuV)                 (dB)
            (MHz)            (dB)        Q.P.       AV.          Q.P.      AV.     Q.P.       AV.        Q.P.       AV.
  1       0.16967           10.10       87.99     23.79         48.09     33.89   64.98     54.98       —16.89    —21.09
  2       0.55679           10.12       30.60     18.14         40.72     28.26   56.00     46.00       —15.28    —17.74
  3       0.76789           10.13       19.85      7.80         29.98     17.93   56.00     46.00       —26.02    —28.07
  4        1.62798          10.17       21.83      8.01         8200      18.18   56.00     46.00       —24.00    —27.82
  5       242171            10.21       20.77      8.32         30.98     18.53   56.00     46.00       —25.02    —27.47
  6       11.45381          10.71       19.02      6.48         29.73     17.19   60.00     50.00       —30.27    —32.81
Remarks:
           1. Q.P. and AV. are abbreviations of quasi—peak and average individually.
          2. The emission levels of other frequencies were very low against the limit.
          3. Margin value = Emission level — Limit value
          4. Correction factor = Insertion loss + Cable loss
          5. Emission Level = Correction Factor + Reading Value




Report No.: RF180523C09—8 R1                           Page No. 22 / 27                          Report Format Version: 6.1.1
Cancels and replaces the report no.: RF1805230C09—8 dated on Jun. 28, 2018


                                                                                                                         3)
                                                                                                                     ommert




                                                                 Detector Function &       .
Frequency Range             150kHz ~ 3OMHz                        Resolution           S:‘:;"Ze(fvgogzéz
                                                                 Bandwidth                     9       B
                                                                 Environmental            s    o
Input Power                 120Vac, 60Hz                         Conditions            25°C, 65%RH

Tested by                   Jisyong Wang                         Test Date             2018/6/14


                                               Phase Of Power : Neutral (N)
         Frequency       |Correction|    Reading Value          Emission Level          Limit                  Margin
 No                         Factor           (dBuV)                  (dBuV)            (dBuV)                     (dB)
            (MHz)            (dB)        a.P.       AV.          Q.P.      AV.     Q.P.       AV.           Q.P.        AV.
           0.17328          10.10       39.95     24.41         50.05     34.51   64.80     54.80          —14.75     —20.29
  —+




           0.19255          10.10       33.66     16.21         43.76     26.31   63.93     53.93          —20.17     —27.62
  No




           0.58792          10.12       15.72      1.87         25.84     11.99   56.00     46.00          —30.16     —34.01
  c3




           0.58792          10.12       24.46     10.96         34.58     21.08   56.00     46.00          —21.42     —24.92
  &




           1.55760          10.16       17.11      1.50         27.27     11.66   56.00     46.00          —28.73     —34.34
  &n




  6        6.31998          10.36       21.93      8.01         8229      18.37   60.00     50.00          —27.71     —31.63
Remarks:
           1. Q.P. and AV. are abbreviations of quasi—peak and average individually.
          2. The emission levels of other frequencies were very low against the limit.
          3. Margin value = Emission level — Limit value
          4. Correction factor = Insertion loss + Cable loss
          5. Emission Level = Correction Factor + Reading Value




Report No.: RF180523C09—8 R1                           Page No. 28 / 27                            Report Format Version: 6.1.1
Cancels and replaces the report no.: RF1805230C09—8 dated on Jun. 28, 2018


4.3     20 dB Bandwidth Measurement
4.3.1     Limits of 20 dB Bandwidth Measurement

Intentional radiators operating under the alternative provisions to the general emission limits, as contained in
§§ 15.217 through 15.257 and in subpart E of this part, must be designed to ensure that the 20 dB bandwidth
of the emission, or whatever bandwidth may otherwise be specified in the specific rule section under which
the equipment operates, is contained within the frequency band designated in the rule section under which
the equipment is operated.


4.3.2     Test Setup



                 EUT                                                Spectrum Analyzer

                                                      Attenuator




4.3.3     Test Instruments

Refer to section 4.1.2 to get information of above instrument.


4.3.4     Test Procedure

a. Check the calibration of the measuring instrument using either an internal calibrator or a known signal
      from an external generator.
b. Turn on the EUT and connect it to measurement instrument. Then set it to any one convenient frequency
      within its operating range. Set a reference level on the measuring instrument equal to the highest peak
      value.
c.    Measure the frequency difference of two frequencies that were attenuated 20dB from the reference level.
      Record the frequency difference as the emission bandwidth.
d. Repeat above procedures until all frequencies measured were complete.


4.3.5     Deviation from Test Standard

No deviation.


4.3.6     EUT Operating Conditions

The software provided by client to enable the EUT under transmission condition continuously at channel
frequencies individually.




Report No.: RF180523C09-8 R1                          Page No. 24 / 27                  Report Format Version: 6.1.1
Cancels and replaces the report no.: RF180523C09-8 dated on Jun. 28, 2018


4.3.7    Test Result

         Channel                  Frequency (MHz)              20 dB Bandwidth (MHz)       Pass / Fail
              1                           2403                        2.402278846              Pass

                                             Spectrum Plot of Worst Value




Report No.: RF180523C09-8 R1                          Page No. 25 / 27                 Report Format Version: 6.1.1
Cancels and replaces the report no.: RF180523C09-8 dated on Jun. 28, 2018


5    Pictures of Test Arrangements

Please refer to the attached file (Test Setup Photo).




Report No.: RF180523C09-8 R1                          Page No. 26 / 27      Report Format Version: 6.1.1
Cancels and replaces the report no.: RF180523C09-8 dated on Jun. 28, 2018


Appendix – Information on the Testing Laboratories


We, Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch, were founded in 1988 to
provide our best service in EMC, Radio, Telecom and Safety consultation. Our laboratories are FCC
recognized accredited test firms and accredited according to ISO/IEC 17025.

If you have any comments, please feel free to contact us at the following:

Linko EMC/RF Lab                                              Hsin Chu EMC/RF/Telecom Lab
Tel: 886-2-26052180                                           Tel: 886-3-6668565
Fax: 886-2-26051924                                           Fax: 886-3-6668323


Hwa Ya EMC/RF/Safety Lab
Tel: 886-3-3183232
Fax: 886-3-3270892


Email: service.adt@tw.bureauveritas.com
Web Site: www.bureauveritas-adt.com

The address and road map of all our labs can be found in our web site also.



--- END ---




Report No.: RF180523C09-8 R1                          Page No. 27 / 27                 Report Format Version: 6.1.1
Cancels and replaces the report no.: RF180523C09-8 dated on Jun. 28, 2018



Document Created: 2019-09-09 03:53:27
Document Modified: 2019-09-09 03:53:27

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC