I18Z60289-IOT07_FCC Report_DFS-Rev1

FCC ID: 2AJOTTA-1081

Test Report

Download: PDF
FCCID_3877692

                                  FCC PART 15E
                                  TEST REPORT
                              No. I18Z60289-IOT07
                                                       for

                                            HMD Global Oy

                                              Smart phone

                                                     With

                                                  TA-1081

                                      FCC ID: 2AJOTTA-1081

                                 Hardware Version: 0317/0309

                              Software Version: 00WW_0_266

                                     Issued Date: 2018-06-05




Note:
The test results in this test report relate only to the devices specified in this report. This report shall not be
reproduced except in full without the written approval of CTTL.
The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST,
or any agency of the U.S.Government.
Test Laboratory:
CTTL, Telecommunication Technology Labs, CAICT
No. 52, Huayuan North Road, Haidian District, Beijing, P. R. China 100191.
Tel:+86(0)10-62304633-2512, Fax:+86(0)10-62304633-2504
Email: cttl_terminals@caict.ac.cn, website: www.caict.ac.cn


                                           No. I18Z60289-IOT07
                                                    Page2 of 17


REPORT HISTORY
Report Number     Revision   Description       Issue Date
I18Z60289-IOT07   Rev.0      1st edition       2018-06-05


                                                                                                             No. I18Z60289-IOT07
                                                                                                                      Page3 of 17


CONTENTS
CONTENTS .................................................................................................................................................. 3

1.             TEST LATORATORY .................................................................................................................. 4

1.1.           TESTING LOCATION ................................................................................................................ 4

1.2.           TESTING ENVIRONMENT ....................................................................................................... 4

1.3.           PROJECT DATA .......................................................................................................................... 4

1.4.           SIGNATURE ................................................................................................................................. 4

2.             CLIENT INFORMATION ........................................................................................................... 5

2.1.           APPLICANT INFORMATION ................................................................................................... 5

2.2.           MANUFACTURER INFORMATION ........................................................................................ 5

3.             EQUIPMENT UNDER TEST (EUT) AND ANCILLARY EQUIPMENT(AE) ...................... 6

3.1.           ABOUT EUT ................................................................................................................................. 6

3.2.           INTERNAL IDENTIFICATION OF EUT USED DURING THE TEST ................................ 6

3.3.           GENERAL DESCRIPTION ........................................................................................................ 6

4.             REFERENCE DOCUMENTS ..................................................................................................... 7

4.1.           DOCUMENTS SUPPLIED BY APPLICANT............................................................................ 7

4.2.           REFERENCE DOCUMENTS FOR TESTING ......................................................................... 7

5.             LABORATORY ENVIRONMENT ............................................................................................. 7

6.             SUMMARY OF TEST RESULTS ............................................................................................... 7

6.1.           SUMMARY OF TEST RESULTS ............................................................................................... 7

6.2.           STATEMENTS .............................................................................................................................. 7

7.             TEST EQUIPMENTS UTILIZED .............................................................................................. 8

ANNEX A: MEASUREMENT RESULTS.................................................................................................. 9

     A.1. MEASUREMENT METHOD .................................................................................................................... 9
     A.2. CHANNEL MOVE TIME AND CHANNEL CLOSING TRANSMISSION TIME ................................................ 12
     A.3. NON-OCCUPANCY PERIOD ................................................................................................................. 14
     A3.1 ASSOCIATED TEST ............................................................................................................................. 14

ANNEX B: PHOTOGRAPHS OF THE TEST SET-UP .......................................................................... 16

ANNEX C: ACCREDITATION CERTIFICATE .................................................................................... 17


                                                               No. I18Z60289-IOT07
                                                                        Page4 of 17



1. TEST LATORATORY
1.1. Testing Location
Location 1:CTTL(huayuan North Road)
  Address:               No. 52, Huayuan North Road, Haidian District, Beijing,
                         P. R. China100191

Location 2:CTTL(Shouxiang)
  Address:               No. 51 Shouxiang Science Building, Xueyuan Road,
                         Haidian District, Beijing, P. R. China100191


1.2. Testing Environment
  Normal Temperature:      15-35℃
  Extreme Temperature:     -10/+55℃
  Relative Humidity:       20-75%


1.3. Project data
  Testing Start Date:      2018-04-02
  Testing End Date:        2018-05-21


1.4. Signature




               Jiang Xue
     ( Prepared this test report )




              Zheng Wei
    (Reviewed this test report)




            Lv Songdong
    (Approved this test report)


                                                        No. I18Z60289-IOT07
                                                                 Page5 of 17



2. CLIENT INFORMATION
2.1. Applicant Information
 Company Name:       HMD Global Oy
 Address:            Karaportti 2 02610 Espoo FINLAND
 City:               Espoo
 Postal Code:        /
 Country:            FINLAND
 Telephone:          +358 408036126
 Fax:                +97143697604


2.2. Manufacturer Information
 Company Name:       HMD Global Oy
 Address:            Karaportti 2 02610 Espoo FINLAND
 City:               Espoo
 Postal Code:        /
 Country:            FINLAND
 Telephone:          +358 408036126
 Fax:                +97143697604


                                                                      No. I18Z60289-IOT07
                                                                               Page6 of 17



3. EQUIPMENT                 UNDER           TEST          (EUT)       AND         ANCILLARY

    EQUIPMENT(AE)
3.1. About EUT
  Description                        Smart phone
  Model name                         TA-1081
  FCC ID                             2AJOTTA-1081
  WLAN Frequency Range               ISM Band:
                                        -5250MHz~5350MHz
                                        -5470MHz~5725MHz
  Type of modulation                 OFDM
  Antenna                            Integral Antenna
  Extreme vol. Limits                3.8V DC by Battery
  Device Type (DFS)                  Client without radar detection(only support client mode)
  TPC mechanism                      Not support
  Antenna gain                       -6dBi
3.2. Internal Identification of EUT used during the test

EUT ID*            S/N                                            HW Version    SW Version
EUT1               /                                              0317/0309     00WW_0_266
*EUT ID: is used to identify the test sample in the lab internally.
3.3. General Description
The Equipment Under Test (EUT) is a model of Smart phone with integrated antenna. It consists of
normal options: lithium battery, charger. Manual and specifications of the EUT were provided to
fulfil the test.


                                                                       No. I18Z60289-IOT07
                                                                                Page7 of 17



4. REFERENCE DOCUMENTS
4.1. Documents supplied by applicant
EUT feature information is supplied by the applicant or manufacturer, which is the basis of testing.
4.2. Reference Documents for testing
The following documents listed in this section are referred for testing.

                          FCC CFR 47, Part 15, Subpart E:
    FCC Part15                                                                           2016
                          15.407 General technical requirements.
    KDB 905642 D02        UNII DFS Compliance Procedures New Rules v01r01                2014
    KDB 905462 D03        UNII Clients Without Radar Detection New Rules v01r01          2014

5. LABORATORY ENVIRONMENT
Measurement is performed in shielding room.

6. SUMMARY OF TEST RESULTS
6.1. Summary of Test Results
                                                         Sub-clause of
    SUMMARY OF MEASUREMENT RESULTS                                                  Verdict
                                                           Part15E
Channel move time          and   channel    closing
                                                         15.407 (h)(2)(iii)           BR
transmission time
Non-Occupancy Period                                     15.407 (h)(2) (iv)           BR
Please refer to ANNEX A for detail.
Terms used in Verdict column
P                    Pass, The EUT complies with the essential requirements in the standard.
NM                   Not measured, The test was not measured by CTTL
NA                   Not Applicable, The test was not applicable
F                    Fail, The EUT does not comply with the essential requirements in the
                     standard
6.2. Statements
CTTL has evaluated the test cases requested by the client/manufacturer as listed in section 6.1 of
this report for the EUT specified in section 3 according to the standards or reference documents
listed in section 4.1.
This report only deal with the UNII DFS functions among the features described in section 3, and
The EUT met all requirements of the reference documents.
The end user is not available to get and modify the parameters of the detected Radar Waveforms
in this product.
The Equipment Under Test (EUT) model TA-1081 (FCC ID: 2AJOTTA-1081) is a variant product of
TA-1088 (FCC ID: 2AJOTTA-1088), according to the declaration of changes provided by the
applicant and FCC KDB publication 178919 D01, all the test results are derived from test report
No. I18Z60296-IOT07. Please refer Annex A for detail data.


                                                                    No. I18Z60289-IOT07
                                                                             Page8 of 17

Test Conditions
T nom               Normal Temperature
T min               Low Temperature
T max               High Temperature
V nom               Normal Voltage
V min               Low Voltage
V max               High Voltage
H nom               Norm Humidity
A nom               Norm Air Pressure
For this report, all the test case listed above is tested under Normal Temperature and Normal
Voltage, and also under norm humidity, the specific conditions as following:
Temperature                        T nom                          26℃
Voltage                            V nom                          3.8V(By battery)
Humidity                           H nom                          44%
Air Pressure                       A nom                          1010hPa




7. TEST EQUIPMENTS UTILIZED
Conducted test system
                                            Serial                      Calibration   Calibration
No.        Equipment          Model                   Manufacturer
                                           Number                         cycle        Due date
        Vector      Signal                            Rohde         &
1                            FSQ40         200089                         1 year      2018-06-01
        Analyzer                                      Schwarz
        Vector      Signal                            Rohde         &
2                            SMU200A       103752                         1 year      2018-06-01
        General                                       Schwarz
3       Shielding Room       S81              /       ETS-Lindgren           /             /


                                                                    No. I18Z60289-IOT07
                                                                             Page9 of 17


ANNEX A: MEASUREMENT RESULTS
A.1. Measurement Method
A.1.1. Conducted Measurements
The below figure shows the DFS setup, where the EUT is a RLAN device operating in slave mode,
without Radar Interference Detection function. This setup also contains a device operating in
master mode. The radar test signals are injected into the master device. The EUT (slave device) is
associated with the master device. WLAN traffic is generated by streaming the mpeg file from the
master to the slave in full monitor video mode using the media player.




Note:
   1) All Measurements are performed with the EUT’s narrowest channel bandwidth.
   2) The master device information is as follows
        Vendor: Cisco
        Model: AIR-AP1252AG-A-K9
        FCC ID: LDK102061, 1DK102062
   3) The software of radar signal generator (R&S SMU200A) is completely designed based on
        FCC-06-96A1/NTIA requirement.


A.1.2. Parameters of DFS test signal
1). Interference threshold values, master or client incorporation in service monitoring. For device
power less than 23dBm (E.I.R.P.), the threshold level is -62 dBm at the antenna port after
correction for antenna gain and procedural adjustments.
Because of conducted measurement performed, the calibration power from radar signal generator
to antenna port of DFS test equipment is -62 dBm.
          Maximum Transmit Power                                       Value
                  > 200 mW                                            -64 dBm
                  < 200 mW                                            -62 dBm
The radar Detection Threshold, lowest antenna gain is the parameter of interference radar
DFS detection threshold.
One 10 Second plot bee reported for the short Pulse Radar type 1-4,the type 0 was be used,
which was selected by auto test software.

Radar Waveform Calibration Result:


                                                                                           No. I18Z60289-IOT07
                                                                                                   Page10 of 17

                                                         RBW    3 MHz     Marker 1 [T1 ]
                                                        * VBW   10 MHz              -62.17 dBm
        Ref   -20 dBm                  Att   5 dB        SWT    1 s             633.012821 ms

        -20


                                                                                                 A
        -30
                                                                                                 SGL
1 AP
CLRWR
        -40




        -50



                                                                      1
        -60




        -70


                                                                                                 3DB
        -80




        -90




        -100




        -110



        -120

        Center 5.6 GHz                              100 ms/




Date: 4.JUN.2018        10:01:55



                                         20M Calibration Result



                                                         RBW    3 MHz     Marker 1 [T1 ]
                                                        * VBW   10 MHz              -62.58 dBm
        Ref   -20 dBm                  Att   5 dB        SWT    1 s             286.858974 ms

        -20


                                                                                                 A
        -30
                                                                                                 SGL
1 AP
CLRWR
        -40




        -50




        -60                        1




        -70


                                                                                                 3DB
        -80




        -90




        -100




        -110



        -120

        Center 5.51 GHz                             100 ms/




Date: 4.JUN.2018        10:03:04



                                         40M Calibration Result


                                                                No. I18Z60289-IOT07
                                                                        Page11 of 17

2). DFS requirement values
The required values are as the following table.
                  Parameter                                       Value
                Non-occupancy                                    > 1800 s
       Channel Availability Check Time                             60 s
              Channel Move Time                                    10 s
     Channel Closing Transmission Time                       200 ms + 60 ms
                                                         Minimum 100% of the 99%
          U-NII Detection Bandwidth
                                                       transmission power bandwidth


As the EUT is IP based system, the MPEG video file from NTIA website is used to steam to EUT
via the Master device.

A.1.3. Measurement Uncertainty
                   Item                            Measurement Uncertainty
                   Time                                     0.70 ms
                  Power                                    0.75 dBm


                                                                                                       No. I18Z60289-IOT07
                                                                                                               Page12 of 17


A.2. Channel move time and channel closing transmission time
Measurement Limit:
                Test Items                                                                       Limit
channel closing transmission time                                                      < 200 ms + 60 ms
Channel move time                                                                               < 10 s

Measurement Results:

Frequency Band: 5250MHz ~ 5350MHz

                                                                       RBW   3 MHz    Marker 1 [T1 ]
                                                                       VBW   10 MHz             -22.11 dBm
                        Ref     0 dBm              * Att   10 dB       SWT   12 s           498.000000 ms

                        0                                                             Delta 2 [T1 ]
                                                                                                -42.99 dB
                                                                                            10.000000 s      A
                        -10
                                                                                                             SGL
                1 AP
                CLRWR       1
                        -20




                        -30




                        -40




                        -50


                                                                                                             3DB
                        -60
                                                                                                2


                        -70




                        -80




                        -90



                        -100

                        Center 5.31 GHz                            1.2 s/




               Date: 31.MAY.2018        10:20:40



The channel move time is as the figure. It shows the time of the radar and the client pulses. The
figure shows that the client stops transmission within 10 seconds, and no transmissions occur
after 10 seconds later of the radar burst signal.


                                                                                                             No. I18Z60289-IOT07
                                                                                                                     Page13 of 17

                                                                             RBW   3 MHz    Delta 4 [T1 ]
                                                                             VBW   10 MHz             -43.03 dB
                        Ref      0 dBm                  * Att   10 dB        SWT   3 s            471.307692 ms

                        0                                                                   Marker 1 [T1 ]
                                                                                                      -21.57 dBm
                                                                                                  466.500000 ms     A
                        -10
                                                                                            Delta 2 [T1 ]          SGL
                1 AP                                                                                  -44.17 dB
                CLRWR                    1
                        -20                                                                        54.307692 ms
                                                                                            Delta 3 [T1 ]
                                                                                                      -44.61 dB
                        -30                                                                       461.692308 ms



                        -40




                        -50


                                                                                                                   3DB
                        -60
                                             2
                                                        4
                                                        3


                        -70




                        -80




                        -90



                        -100

                        Center 5.27 GHz                                 300 ms/




               Date: 31.MAY.2018             10:14:48



The closing transmission time is as the figure, and the result is (Δ2-Δ1)+(Δ4-Δ3)*5=102.41ms.

Conclusion: PASS



Frequency Band: 5470MHz ~ 5725MHz

                                                                             RBW 3 MHz      Delta 2 [T1 ]
                                                                           * VBW   10 MHz             -45.22 dB
                        Ref    -10 dBm                   Att    15 dB        SWT 12 s             10.000000 s

                         -10 1                                                              Marker 1 [T1 ]
                                                                                                      -16.43 dBm
                                                                                                  692.307692 ms    A
                         -20
                                                                                                                   SGL
                1 AP
                CLRWR
                         -30




                         -40




                         -50



                                                                                                       2
                         -60


                                                                                                                   3DB
                         -70




                         -80




                         -90




                         -100



                         -110

                        Center 5.51 GHz                                 1.2 s/




               Date: 17.APR.2018             14:57:38



The channel move time is as the figure. It shows the time of the radar and the client pulses. The
figure shows that the client stops transmission within 10 seconds, and no transmissions occur
after 10 seconds later of the radar burst signal.


                                                                                                        No. I18Z60289-IOT07
                                                                                                                Page14 of 17

                                                                        RBW   3 MHz    Delta 4 [T1 ]
                                                                        VBW   10 MHz             -51.99 dB
                       Ref   -10 dBm                * Att   0 dB        SWT   3 s            171.307692 ms

                       -10                                                             Marker 1 [T1 ]
                                                                                                 -21.01 dBm
                                        1
                                                                                             559.500000 ms    A
                       -20
                                                                                       Delta 2 [T1 ]          SGL
               1 AP                                                                              -52.12 dB
               CLRWR
                       -30                                                                   60.692308 ms
                                                                                       Delta 3 [T1 ]
                                                                                                 -52.68 dB
                       -40                                                                   161.692308 ms



                       -50




                       -60


                                                                                                              3DB
                       -70                  2   4
                                                3



                       -80




                       -90




                       -100



                       -110

                       Center 5.51 GHz                             300 ms/




               Date: 31.MAY.2018       18:24:03



The closing transmission time is as the figure, and the result is (Δ2-Δ1)+(Δ4-Δ3)*5=108.79ms

Conclusion: PASS
A.3. Non-Occupancy Period
Measurement Limit:
               Test Items                                                                         Limit
Non-Occupancy Period                                                                              > 1800 s

A3.1 Associated test

Associate the master and client, transmit specified stream between the master and client; monitor
the analyzer on the operating frequency to make sure no beacons have been transmitted for 1800
seconds.


                                                                                                             No. I18Z60289-IOT07
                                                                                                                     Page15 of 17

Frequency Band: 5250MHz ~ 5350MHz

                                                                         RBW 3 MHz      Delta 2 [T1 ]
                                                                         VBW   10 MHz             -39.66 dB
                         Ref    -10 dBm               Att    15 dB       SWT 2000 s             1.800000 ks

                          -10                                                           Marker 1 [T1 ]
                          1
                                                                                                  -16.62 dBm
                                                                                              54.487179 s      A
                          -20
                                                                                                               SGL
                 1 AP
                 CLRWR
                          -30




                          -40




                          -50
                                                                                                         2


                          -60


                                                                                                               3DB
                          -70




                          -80




                          -90




                          -100



                          -110

                         Center 5.26 GHz                             200 s/




                Date: 12.APR.2018         13:03:12



The figure above shows that the client does not transmit any emission within 1800 seconds after
getting the order of “stop transmits” from the DFS master (access point).


Frequency Band: 5470MHz ~ 5725MHz
                                                                         RBW   3 MHz    Delta 2 [T1 ]
                                                                         VBW   10 MHz             -52.49 dB
                         Ref    -10 dBm              * Att   0 dB        SWT   2000 s           1.800000 ks

                         -10                                                            Marker 1 [T1 ]
                                                                                                  -21.66 dBm
                          1                                                                    50.000000 s      A
                         -20
                                                                                                               SGL
                1 AP
                CLRWR
                         -30




                         -40




                         -50




                         -60


                                                                                                               3DB
                         -70                                                                             2



                         -80




                         -90




                         -100



                         -110

                         Center 5.67 GHz                             200 s/




                Date: 31.MAY.2018         19:51:38



The figure above shows that the client does not transmit any emission within 1800 seconds after
getting the order of “stop transmits” from the DFS master (access point).

.

Conclusion: PASS


                                     No. I18Z60289-IOT07
                                             Page16 of 17


ANNEX B: PHOTOGRAPHS OF THE TEST SET-UP


Layout of Conducted Test


                                                   No. I18Z60289-IOT07
                                                           Page17 of 17


ANNEX C: Accreditation Certificate




                      *** END OF REPORT BODY ***



Document Created: 2018-06-05 10:58:50
Document Modified: 2018-06-05 10:58:50

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC