RF Exposure

FCC ID: 2AJMW-MS500B

RF Exposure Info

Download: PDF
FCCID_3956413

Reference No.: WTD18S07118156-2W




      FCC ID: 2AJMW-MS500B RF Exposure Report
     Test Requirement:      FCC Part 1.1307
     Evaluation Method:     FCC Part 2.1091 & KDB 447498 D01 General RF Exposure Guidance v06
      Requirements

     Systems operating under the provisions of this section shall be operated in a manner that ensures
     that the public is not exposed to radio frequency energy levels in excess limit for maximum
     permissible exposure. In accordance with 47 CFR FCC Part 2 Subpart J, section 2.1091 this device
     has been defined as a mobile device whereby a distance of 0.2 m normally can be maintained
     between the user and the device.
      The procedures / limit

    (A) Limits for Occupational / Controlled Exposure
                                             Magnetic Field                       Averaging Time
   Frequency Range        Electric Field                      Power Density (S)
                                              Strength (H)                         |E|2,|H|2or S
         (MHz)         Strength (E) (V/m)                        (mW/ cm2)
                                                 (A/m)                              (minutes)
         0.3-3.0              614                1.63              (100)*               6
         3.0-30             1842 / f            4.89 / f          (900 / f)*            6
         30-300               61.4              0.163                1.0                6
       300-1500                                                    F/300                6
     1500-100,000                                                      5                6

     (B) Limits for General Population / Uncontrolled Exposure
                                            Magnetic Field                        Averaging Time
   Frequency Range        Electric Field                     Power Density (S)
                                             Strength (H)                          |E|2,|H|2 or S
        (MHz)          Strength (E) (V/m)                       (mW/ cm2)
                                                (A/m)                                (minutes)
        0.3-1.34              614                1.63              (100)*               30
        1.34-30              824/f              2.19/f             (180/f)*             30
         30-300               27.5              0.073                0.2                30
       300-1500                                                    F/1500               30
     1500-100,000                                                    1.0                30

    Note: f = frequency in MHz; *Plane-wave equivalent power density




Waltek Services (Shenzhen) Co.,Ltd.
http://www.waltek.com.cn


         MPE Calculation Method
                P G
         S=
              4   R2
         S = power density (in appropriate units, e.g. mW/cm2)
         P = output power to the antenna (in appropriate units, e.g., mW).
         G = power gain of the antenna in the direction of interest relative to an isotropic radiator,
                     the power gain factor, is normally numeric gain.
         R = distance to the center of radiation of the antenna (appropriate units, e.g., cm)


         From the peak EUT RF output power, the minimum mobile separation distance, R=20cm,
         as well as the gain of the used antenna, the RF power density can be obtained


                                               Max. conducted                         Limit of
               Antenna     Max. conducted                             Power
Antenna                                                                               Power
                Gain       Output Power          Output Power        Density                             Reult
Gain (dBi)                                                                           Density
              (numeric)        (dBm)                                (mW/cm2)
                                                     (mW)                           (mW/cm2)

   0.0           1.0             0.76                 1.19          0.000237             1          Compliance


         Result: Compliance
 No SAR measurement is required.

                                               ======End======