RF Exposure

FCC ID: 2AJIV-MF8360

RF Exposure Info

Download: PDF
FCCID_4034448

 Reference No.: WTS18S08121897W

Model: MF8360

RF Exposure
     Test Requirement:                     FCC Part 1.1307
     Evaluation Method:                    FCC Part 2.1091


 Requirements

     Systems operating under the provisions of this section shall be operated in a manner that ensures that
     the public is not exposed to radio frequency energy levels in excess limit for maximum permissible
     exposure. In accordance with 47 CFR FCC Part 2 Subpart J, section 2.1091 this device has been
     defined as a mobile device whereby a distance of 0.2 m normally can be maintained between the user
     and the device.


 The procedures / limit

    (A) Limits for Occupational / Controlled Exposure
                                              Magnetic Field                         Averaging Time
     Frequency Range        Electric Field                     Power Density (S)
                                               Strength (H)                           |E|2,|H|2or S
          (MHz)         Strength (E) (V/m)                        (mW/ cm2)
                                                  (A/m)                                (minutes)
          0.3-3.0               614               1.63               (100)*                 6
           3.0-30             1842 / f           4.89 / f           (900 / f)*              6
          30-300               61.4               0.163                 1.0                 6
         300-1500                                                    F/300                  6
       1500-100,000                                                     5                   6

      (B) Limits for General Population / Uncontrolled Exposure
                                              Magnetic Field                         Averaging Time
     Frequency Range        Electric Field                      Power Density (S)
                                               Strength (H)                           |E|2,|H|2 or S
           (MHz)         Strength (E) (V/m)                        (mW/ cm2)
                                                   (A/m)                                (minutes)
          0.3-1.34              614               1.63               (100)*                30
          1.34-30              824/f              2.19/f            (180/f)*               30
          30-300               27.5               0.073                 0.2                30
         300-1500                                                   F/1500                 30
       1500-100,000                                                     1.0                30
    Note: f = frequency in MHz ; *Plane-wave equivalent power density




Waltek Services (Shenzhen) Co.,Ltd.
http://www.waltek.com.cn


 Reference No.: WTS18S08121897W




 MPE Calculation Method
      P = Peak RF output power (W)
      G = EUT Antenna numeric gain (numeric)
      d = Separation distance between radiator and human body (m)=0.2m
      The formula can be changed to
      Pd =Pout*G/(4*Pi*R2)
From the peak EUT RF output power, the minimum mobile separation distance, d=0.2m, as well as the
gain of the used antenna, the RF power density can be obtained.


                                       Max. Peak                                  Limit of Power
       Antenna      Antenna Gain                    Peak Output   Power Density
                                        Output                                       Density
       Gain (dBi)     (numeric)                                    (mW/cm2)
                                      Power (dBm)   Power (mW)                      (mW/cm2)

         -4.12          0.387            2.72           1.87         0.0001             1


Result: Compliance.