                                              TEST REPORT
 Reference No. ...................         : WTS19S04027029W002

 FCC ID………………………                           : 2AJIV-MF1690

 Applicant ...........................     : Creative Labs Pte. Ltd.
 Address .............................     : 31 International Business Park #03-01 Creative Resource Singapore
                                             609921
 Manufacturer ....................         : Creative Labs Pte. Ltd.
 Address .............................     : 31 International Business Park #03-01 Creative Resource Singapore
                                             609921
 Factory ...............................   : AJS Electronics Limited
 Address .............................     : 15/F, Liuchuang Building II, No. 29, South Ring Road, South Area Hi-
                                             Tech Zone, Nanshan District, Shenzhen, China
 Product ..............................    : Creative T100
 Model(s). ............................    : MF1690

 Standards ..........................      : FCC CFR47 Part 15 Section 15.247:2019

 Date of Receipt sample ....               : 2019-04-30

 Date of Test .......................      : 2019-04-31 to 2019-05-17

 Date of Issue .....................       : 2019-06-06
 Test Result ........................      : Pass
 Remarks:
 The results shown in this test report refer only to the sample(s) tested, this test report cannot be
 reproduced, except in full, without prior written permission of the company. The report would be invalid
 without specific stamp of test institute and the signatures of compiler and approver.



                                              Prepared By:
                                 Waltek Services (Shenzhen) Co., Ltd.
    Address: 1/F., Fukangtai Building, West Baima Road, Songgang Street, Baoan District, Shenzhen,
                                           Guangdong, China
                                         Tel :+86-755-83551033
                                         Fax:+86-755-83552400

         Compiled by:                                                          Approved by:




         Frank Yin / Test Engineer                                             Philo Zhong / Manager




Waltek Services (Shenzhen) Co.,Ltd.
http://www.waltek.com.cn                                  Page 1 of 7


Reference No.: WTS19S04027029W002                    Page 2 of 7


1     Laboratories Introduction
Waltek Services (Shenzhen) Co., Ltd is a professional third-party testing and certification laboratory with
multi-year product testing and certification experience, established strictly in accordance with ISO/IEC 17025
requirements, and accredited by ILAC (International Laboratory Accreditation Cooperation) member. A2LA
(American Association for Laboratory Accreditation, the certification number is 4243.01) of USA, CNAS
(China National Accreditation Service for Conformity Assessment, the registration number is L3110) of
China.Meanwhile, Waltek has got recognition as registration and accreditation laboratory from EMSD
(Electrical and Mechanical Services Department), and American Energy star, FCC(The Federal
Communications Commission), CEC(California energy efficiency), ISED (Innovation, Science and Economic
Development Canada). It’s the strategic partner and data recognition laboratory of international authoritative
organizations, such as Intertek(ETL-SEMKO), TÜV Rheinland, TÜV SÜD, etc.




Waltek Services (Shenzhen) Co., Ltd is one of the largest and the most comprehensive third party testing
laboratory in China. Our test capability covered four large fields: safety test. ElectroMagnetic
Compatibility(EMC), and energy performance, wireless radio. As a professional, comprehensive, justice
international test organization, we still keep the scientific and rigorous work attitude to help each client satisfy
the international standards and assist their product enter into globe market smoothly.




Waltek Services (Shenzhen) Co.,Ltd.
http://www.waltek.com.cn


Reference No.: WTS19S04027029W002              Page 3 of 7



1.1   Test Facility
      A. Accreditations for Conformity Assessment (International)
       Country/Region        Scope Covered By                Scope                Note
       USA                                                   FCC ID \ DOC \ VOC   1
       Canada                                                IC ID \ VOC          2
       Japan                                                 MIC-T \ MIC-R        -
       Europe                                                EMCD \ RED           -
       Taiwan                                                NCC                  -
                             ISO/IEC 17025
       Hong Kong                                             OFCA                 -
       Australia                                             RCM                  -
       India                                                 WPC                  -
       Thailand                                              NTC                  -
       Singapore                                             IDA                  -
       Note:
       1.   FCC Designation No.: CN1201. Test Firm Registration No.: 523476.
       2.   ISED CAB identifier: CN0013.

      B.TCBs and Notify Bodies Recognized Testing Laboratory.


       Recognized Testing Laboratory of …                    Notify body number
       TUV Rheinland
       Intertek
                                                             Optional.
       TUV SUD
       SGS
       Phoenix Testlab GmbH                                  0700
       Element Materials Technology Warwick Ltd.             0891
       Timco Engineering, Inc.                               1177
       Eurofins Product Service GmbH                         0681




Waltek Services (Shenzhen) Co.,Ltd.
http://www.waltek.com.cn


Reference No.: WTS19S04027029W002                                            Page 4 of 7


2     Contents
                                                                                                                                                                   Page
     COVER PAGE ........................................................................................................................................... 1
1    LABORATORIES INTRODUCTION ................................................................................................................... 2
     1.1     TEST FACILITY ................................................................................................................................................. 3
2    CONTENTS ............................................................................................................................................................ 4

3    REVISION HISTORY ............................................................................................................................................ 5
4    GENERAL INFORMATION .................................................................................................................................. 6
     4.1     GENERAL DESCRIPTION OF E.U.T ................................................................................................................. 6
     4.2     DETAILS OF E.U.T........................................................................................................................................... 6
5    FCC ID: 2AJIV-MF1690 RF EXPOSURE REPORT ........................................................................................ 7
     5.1     REQUIREMENTS............................................................................................................................................... 7
     5.2     THE PROCEDURES / LIMIT................................................................................................................................ 7
     5.3     RESULT: COMPLIANCE .................................................................................................................................... 7




Waltek Services (Shenzhen) Co.,Ltd.
http://www.waltek.com.cn


 Reference No.: WTS19S04027029W002           Page 5 of 7


 3     Revision History
                              Date of
                                                            Date of
     Test report No.          Receipt    Date of Test                   Purpose    Comment   Approved
                                                             Issue
                              sample

                                         2019-04-31
WTS19S04027029W002          2019-04-30       to            2019-06-04   original      -       Valid
                                         2019-05-17




 Waltek Services (Shenzhen) Co.,Ltd.
 http://www.waltek.com.cn


Reference No.: WTS19S04027029W002                Page 6 of 7


4      General Information
4.1    General Description of E.U.T
Product                   : Creative T100

Model(s)                  : MF1690
Operation Frequency       : 2402-2480MHz, 79(EDR) Channels in total
Antenna installation      : PCB Printed Antenna
Antenna Gain              : 1.9dBi
Type of Modulation        : GFSK, π/4DQPSK, 8DPSK

4.2    Details of E.U.T
      Ratings                   Power adapter:
                                Input: 100-240V~, 50/60Hz, 1.5A
                                Output: 18V    2A




Waltek Services (Shenzhen) Co.,Ltd.
http://www.waltek.com.cn


Reference No.: WTS19S04027029W002                 Page 7 of 7


5      FCC ID: 2AJIV-MF1690 RF Exposure Report
       Test Requirement:        FCC Part 1.1307
       Evaluation Method       FCC Part2.1093 & KDB 447498 D01 General RF Exposure Guidance v06
5.1    Requirements

       1) The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances
       ≤50 mm are determined by:
       [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)] · [√
       f(GHz)] ≤3.0 for 1-g SAR and ≤7.5 for 10-g extremity SAR where


       1.    f(GHz) is the RF channel transmit frequency in GHz
       2.    Power and distance are rounded to the nearest mW and mm before calculation
       3.    The result is rounded to one decimal place for comparison
       The test exclusions are applicable only when the minimum test separation distance is ≤50 mm and
       for transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation
       distance is < 5 mm, a distance of 5 mm is applied to determine SAR test exclusion.
5.2    The procedures / limit

                             Source-based       Minimum test         SAR Test
                                                                                     SAR Test
Conducted      Conducted    time-averaged    separation distance     Exclusion
                                                                                     Exclusion
    Peak         Peak          maximum         required for the     Thresholds                     Result
                                                                                    Thresholds
power(dBm)    power(mW) conducted output exposure conditions        Calculation
                                                                                       Limit
                              power(mW)             (mm)                 Value
    1.76          1.50           1.50                 5                  0.473          3.0      Compliance
       Remark: Max. duty factor is 100%
       Low Chanel: f=2402MHz=2.402GHz, so √f(GHz)=1.550
       High Chanel: f=2480MHz=2.480GHz, so √f(GHz)=1.575


5.3    Result: Compliance
No SAR measurement is required.



                                        ======End of Report======