                                                                          Page:        1 of 7
1    Cover page


                       SAR Evaluation Report
Application No.:                 SZEM1809008379CR
Applicant:                       Creative Labs Pte. Ltd.
Address of Applicant:            31 lnternational Business Park, #03-01 Creative Resource, Singapore 609921
Manufacturer:                    Creative Labs Pte. Ltd.
Address of Manufacturer:         31 lnternational Business Park, #03-01 Creative Resource, Singapore 609921
Equipment Under Test (EUT):
EUT Name:                        Creative SXFI Theater Headset
Model No.:                       GH0380B
Trade mark:                      CREATIVE
FCC ID:                          2AJIV-GH0380B
Standards:                       47 CFR Part 1.1307
                                 47 CFR Part 2.1093
                                 KDB447498D01 General RF Exposure Guidance v06
Date of Receipt:                 2018-09-19
Date of Test:                    2018-09-30 to 2019-04-15
Date of Issue:                   2019-04-19
Test Result :                      PASS*

*   In the configuration tested, the EUT complied with the standards specified above.




            Keny Xu
      EMC Laboratory Manager


                               SGS-CSTC Standards Technical Services Co., Ltd.
                               Shenzhen Branch
                                                               Report No.: SZEM180900837906
                                                               Page:       2 of 7


2    Version


                                             Revision Record

         Version       Chapter               Date                  Modifier       Remark

         01                               2019-04-19                              Original




    Authorized for issue by:




                                  Vincent Chen /Project Engineer




                                  Eric Fu /Reviewer


                                                SGS-CSTC Standards Technical Services Co., Ltd.
                                                Shenzhen Branch
                                                                                                      Report No.: SZEM180900837906
                                                                                                      Page:       3 of 7


3         Contents
                                                                                                                                                               Page
1       COVER PAGE .............................................................................................................................................. 1
2       VERSION ...................................................................................................................................................... 2
3       CONTENTS .................................................................................................................................................. 3
4       GENERAL INFORMATION .......................................................................................................................... 4
    4.1         GENERAL DESCRIPTION OF EUT ............................................................................................................. 4
    4.2         TEST LOCATION...................................................................................................................................... 5
    4.3         TEST FACILITY........................................................................................................................................ 5
    4.4         DEVIATION FROM STANDARDS ................................................................................................................. 6
    4.5         ABNORMALITIES FROM STANDARD CONDITIONS ....................................................................................... 6
    4.6         OTHER INFORMATION REQUESTED BY THE CUSTOMER ............................................................................. 6
5       SAR EVALUATION ...................................................................................................................................... 7
    5.1     RF EXPOSURE COMPLIANCE REQUIREMENT ............................................................................................ 7
       5.1.1 Standard Requirement ..................................................................................................................... 7
       5.1.2 Limits ................................................................................................................................................ 7
       5.1.3 EUT RF Exposure ............................................................................................................................ 7


                           SGS-CSTC Standards Technical Services Co., Ltd.
                           Shenzhen Branch
                                                         Report No.: SZEM180900837906
                                                         Page:       4 of 7


4     General Information
4.1 General Description of EUT
     Power supply:             Headset powered by Li-ion battery: 3.7V 1300mAh,
                              Charged by DC 5V, 1A from Type-C port
     Cable:                   Type-C cable 200cm shielded
                              Line in cable 159cm unshielded
                              Microphone cable 17.5cm shielded
For 2.4G
     Operation Frequency      2403.35-2479.35MHz
     Modulation Type          GFSK
     Number of Channels       39
     Channel Spacing          2MHz
     Antenna Type             Chip Antenna
     Antenna Gain             -1.18dBi


                              SGS-CSTC Standards Technical Services Co., Ltd.
                              Shenzhen Branch
                                                               Report No.: SZEM180900837906
                                                               Page:       5 of 7


4.2 Test Location
    All tests were performed at:
    SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch
    No. 1 Workshop, M-10, Middle section, Science & Technology Park, Shenzhen, Guangdong, China
    518057
    Telephone: +86 (0) 755 2601 2053 Fax: +86 (0) 755 2671 0594
    No tests were sub-contracted.

4.3 Test Facility
    The test facility is recognized, certified, or accredited by the following organizations:
    • CNAS (No. CNAS L2929)
    CNAS has accredited SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch EMC
    Lab to ISO/IEC 17025:2005 General Requirements for the Competence of Testing and Calibration
    Laboratories (CNAS-CL01 Accreditation Criteria for the Competence of Testing and Calibration
    Laboratories) for the competence in the field of testing.
    • A2LA (Certificate No. 3816.01)
    SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen EMC Laboratory is accredited by the
    American Association for Laboratory Accreditation(A2LA). Certificate No. 3816.01.
    • VCCI
    The 3m Fully-anechoic chamber for above 1GHz, 10m Semi-anechoic chamber for below 1GHz,
    Shielded Room for Mains Port Conducted Interference Measurement and Telecommunication Port
    Conducted Interference Measurement of SGS-CSTC Standards Technical Services Co., Ltd. have
    been registered in accordance with the Regulations for Voluntary Control Measures with Registration
    No.: G-20026, R-14188, C-12383 and T-11153 respectively.
    • FCC –Designation Number: CN1178
    SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen EMC Laboratory has been recognized
    as an accredited testing laboratory.
    Designation Number: CN1178. Test Firm Registration Number: 406779.
    • Innovation, Science and Economic Development Canada
    SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen EMC Laboratory has been recognized
    by ISED as an accredited testing laboratory.
    CAB identifier: CN0006.
    IC#: 4620C.F


                   SGS-CSTC Standards Technical Services Co., Ltd.
                   Shenzhen Branch
                                             Report No.: SZEM180900837906
                                             Page:       6 of 7


4.4 Deviation from Standards
   None.

4.5 Abnormalities from Standard Conditions
   None.

4.6 Other Information Requested by the Customer
   None.


                                                SGS—CSTC Standards Technical Services Co., Ltd.
                                                Shenzhen Branch

                                                                                                                 Report No.: SZEM180900837906
                                                                                                                 Page:                    7 of 7



5         SAR Evaluation

5.1       RF Exposure Compliance Requirement
5.1.1     Standard Requirement
        According to KDB447498D01 General RF Exposure Guidance v06
        4.3.1. Standalone SAR test exclusion considerations
              Unless specifically required by the published RF exposure KDB procedures, standalone 1—g
        head or body and 10—g extremity SAR evaluation for general population exposure conditions, by
        measurement or numerical simulation, is not required when the corresponding SAR Exclusion
        Threshold condition, listed below, is satisfied.
5.1.2 Limits
        The 1—g and 10—g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances
        < 50 mm are determined by:

        [{max. power of channel, including tune—up tolerance, mW)/({min. test separation distance, mm)] ®
        [Nf(GHz)] 3.0 for 1—g SAR and s 7.5 for 10—g extremity SAR, where

          f(GHz) is the RF channel transmit frequency in GHz
          Power and distance are rounded to the nearest mW and mm before calculation‘"
          The result is rounded to one decimal place for comparison
        The test exclusions are applicable only when the minimum test separation distance is s 50 mm and
        for transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation
        distance is < 5 mm, a distance of 5 mm is applied to determine SAR test exclusion
5.1.3 EUT RF Exposure
For Headset
         The Max. power (including tung—up tolerance) is 3.29                                    dBm on the lowest channel                      24034 GHz (*)
         3.29 dBm logarithmic terms convert to numeric result is nearly 2.13 mW
         According to the formula. calculate the test exclusion thresholds:
         [{max. power of channel, including tune—up tolerance, mW)/({min. test separation distance, mm)] +
         [vf(GHz)]
         General RF Exposure = (2.13 mW / 5 mm) x [2.40335 GHz = 0.66                                                                           (1)
         SAR requirement:
         S=3.0                                                                                                                                  (2)
         (1) < (2)
         So the SAR report is not required.

         (*) Max. power refer to Report No.:No.:SZEM180900837903


                                                                       — End of the Report —



                                Unless otherwise agreed in writing, this document is issued by the Company subject to its General Conditions of Service printed
                                overleaf, available on request or accessible at hitp:!/www.sgs.comfen/Terms—and—Conditions.aspx and, for electronic format documents,
                                subject to Terms and Conditions for Electronie Documents at hlp:Jwwi.ogs.comfen/Terms—and—Conditions/Terms—©—Document.aspx
                                Attention is drawn to the limitation of labilty, indemnification and Jurisdiction issues defined tharein. Any holder of this document is
                                advised that information contained hereonreflects the Company‘s findings at the time of its intervention only and within the limits of
                                Clients instructions, if any. The Company‘s sole responsiblity is to its Client and this document does not exonerate parties to a
                                transaction from exereising all their rights and obligations under the transaction documents. This document cannot be reproduced
                                except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsifation of the content or
                                appearance of this documentis unlawiul and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the
                                results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 30 days only.
                                Attention: To check the authenticity of testing /inspoction report & certificate, please contact us at telephone: (86—755) 8307 1443,
                                or email: CN.Doecheck@sgs.com
                        o. lt       No.t WortshopN10 l Secton, Science 8 Technology Par; Shenzhen,China 518057   t (86—755) 26012053 f (86—788) 26710504   ww sgsgroup.com.en
                                    #B —RHI— ARRIHEN—10H—S1B                                   #BSA: 518057      t (€6—750)26012058 f (86—755) 26710504    sgo:china@egs.com
                                t
                                                                                                                                    Member of the SGS Group (SGS SA)



Document Created: 2019-05-16 01:08:08
Document Modified: 2019-05-16 01:08:08

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC