test report

FCC ID: 2AJGM-UV82

Test Report

Download: PDF
FCCID_3900037

                            ®
                                        52        \     /ss   fll
  A\G                            %statiao:of gfllzal Ct%plia,r{;ejz                                                                                               Page 1 of 30




                                             FCC Test Report

                                                      Report No.: AGCO02294180601FEO8



            FCC ID                                                   :    —2AJGM—UV82

            PRODUCT DESIGNATION                                      :      DUAL BAND F3E TRANSCEIVER

            BRAND NAME                                               :    BAOFENG, Pofung

            MODEL NAME                                               :    UV—82, UV—82L, GT—5
             CLIENT                                                       PO FUNG ELECTRONIC(HK) INTERNATIOANL
                                                                          GROUP COMPANY
            DATE OF ISSUE                                            :    Jun. 23, 2018

            STANDARD(S)                                              :    FCC Part 15 Rules

            REPORT VERSION                                           :    V 11




                     Attestation of Global GOmplianke (Shenzhen) Co., Ltd


          CAUTION:
          This report shall not be reproduced e                                                             t the written permission of the test
          laboratory and shall not be quoted out 0




The results ,m i           est
is issued by/A   , this docu/mo it cannot be reproduced except in full with our prior written permission. The more details and the authenticity of the report will be


            : AGC >
confirmed a tfittp://www.agc-% t.com.
            9

Attestatiq ,ngIoba!Q o              pliance             Tel: +86—755 2908 1955            Fax: +86—755 2600 8484             E—mail: agc@agc—cert.com             @ 400 089 2118
                                                        Add: 2/F. , Building 2, No.1—4, Chaxi Sanwei Technical Industrial Park,Gushu, Xixiang, Bacan District, Shenzhen, Guangdong China


                                                               Report No.: AGC02294180601FE08
                                                                                   Page 2 of 30


                                    Report Revise Record
Report Version   Revise Time   Issued Date     Valid Version                Notes

     V1.0             /        Jun. 13, 2018      Invalid               Initial Release

     V1.1            1st       Jun. 23, 2018       Valid             Update the comments.


                                                                                                         Report No.: AGC02294180601FE08
                                                                                                                             Page 3 of 30


                                     TABLE OF CONTENTS
1. VERIFICATION OF COMPLIANCE ................................................................................................................. 4
2. PRODUCT INFORMATION .............................................................................................................................. 5
3. IDENTIFICATION OF THE RESPONSIBLE TESTING LOCATION ............................................................... 6
4. SUPPORT EQUIPMENT LIST ......................................................................................................................... 7
5. SYSTEM DESCRIPTION .................................................................................................................................. 7
6. SUMMARY OF TEST RESULTS ..................................................................................................................... 8
7. FCC RADIATED EMISSION TEST .................................................................................................................. 9
       7.1. TEST EQUIPMENT OF RADIATED EMISSION .................................................................................... 9
       7.2. LIMITS OF RADIATED EMISSION TEST .............................................................................................. 9
       7.3 BLOCK DIAGRAM OF RADIATED EMISSION TEST ............................................................................ 9
       7.4 PROCEDURE OF RADIATED EMISSION TEST ................................................................................. 11
       7.5 TEST RESULT OF RADIATED EMISSION TEST ................................................................................ 12
8. CONDUCTED EMISSION TEST .................................................................................................................... 16
       8.1 PROVISIONS APPLICABLE ................................................................................................................. 16
       8.2 MEASUREMENT PROCEDURE ........................................................................................................... 16
       8.3 TEST SETUP BLOCK DIAGRAM ......................................................................................................... 17
       8.4 TEST RESULT....................................................................................................................................... 18
9. ANTENNA CONDUCTED POWER FOR RECEIVERS ................................................................................. 20
APPENDIX 1 PHOTOGRAPHS OF TEST SETUP ............................................................................................ 23
APPENDIX 2 PHOTOGRAPHS OF EUT ........................................................................................................... 24


                                                                               Report No.: AGC02294180601FE08
                                                                                                   Page 4 of 30

1. VERIFICATION OF COMPLIANCE

Applicant                     PO FUNG ELECTRONIC(HK) INTERNATIOANL GROUP COMPANY
Address                       3/F FULOK BLDG 131-133 WING LOK ST SHEUNG WAN, Hong Kong
Manufacturer                  PO FUNG ELECTRONIC(HK) INTERNATIOANL GROUP COMPANY
Address                       3/F FULOK BLDG 131-133 WING LOK ST SHEUNG WAN, Hong Kong
Product Designation           DUAL BAND F3E TRANSCEIVER
Brand name                    BAOFENG, Pofung
Test Model                    UV-82
Serial Model                  UV-82L, GT-5
                              All the same except the model name, brand name appearance and shape.
Serial Model Difference
                              UV-82, UV-82L (Brand name is BAOFENG), GT-5(Brand name is Pofung)

Hardware Version              UV82-FST8-VER02
Software Version      UV82
Measurement Procedure ANSI C63.4: 2014
Date of test:         Jun. 05, 2018 to Jun. 13, 2018
Deviation:               None
Condition of Test Sample Normal

The above equipment was tested by Attestation Of Global Compliance (Shenzhen) Co., Ltd. for compliance with
the requirements set forth in the FCC Rules and Regulations Part 15, the measurement procedure according to
ANSI C63.4:2014. This said equipment in the configuration described in this report shows the maximum
emission levels emanating from equipment are within the compliance requirements.
The test results of this report relate only to the tested sample identified in this report.




                            Tested by



                                               Steven Zhou(Zhou Pengyun)         Jun. 13, 2018

                          Reviewed by


                                                    Bart Xie(Xie Xiaobin)        Jun. 23, 2018


                                                                          Report No.: AGC02294180601FE08
                                                                                              Page 5 of 30

2. PRODUCT INFORMATION
The EUT is a DUAL BAND FM TRANSCEIVER designed for voice communication. It is designed by way of
utilizing the F3E modulation achieves the system operating.
A major technical description of EUT is described as following:

  Communication Type          Voice / Tone only
  Modulation                  FM
  RX Frequency Range          Rx:136 MHz -174 MHz, 400MHz -480MHz
  Emission Type               F3E
  Antenna Designation         Detachable
  Antenna Gain                2.15dBi
  Power Supply                DC 7.4V 2000mAh, charging with DC 8.4V.
                              INPUT:AC 110-240V~ 50/60Hz ,0.4A
  Adapter Parameter
                              OUTPUT:DC 10V 1A
                              INPUT: DC 10V 1A
  Charger Parameter
                              OUTPUT:DC 8.4V 0.5A



                        I/O Port Information (    Applicable        Not Applicable)

                                            I/O Port of EUT

           I/O Port Type                   Q’TY                     Cable                Tested with

           DC Input Port                    1                  1.14m, Unshielded              1

       Antenna Connect Port                 1                         0                       1


                                                                        Report No.: AGC02294180601FE08
                                                                                            Page 6 of 30

3. IDENTIFICATION OF THE RESPONSIBLE TESTING LOCATION
      Test Site           Attestation of Global Compliance (Shenzhen) Co., Ltd
                          1-2F., Bldg.2, No.1-4, Chaxi Sanwei Technical Industrial Park, Gushu, Xixiang,
      Location            Bao’an District B112-B113, Bldg.12, Baoan Bldg Materials Center, No.1 of Xixiang
                          Inner Ring Road, Baoan District, Shenzhen 518012
 NVLAP LAB CODE           600153-0
Designation Number        CN5028
  FCC Test Firm
                          682566
Registration Number
                          Attestation of Global Compliance(Shenzhen) Co., Ltd is accredited by National
    Description
                          Voluntary Laboratory Accreditation program, NVLAP Code 600153-0


List Of Test Equipment:
TEST EQUIPMENT OF CONDUCTED EMISSION TEST
     Equipment            Manufacturer         Model              S/N             Cal. Date         Cal. Due
  TEST RECEIVER               R&S               ESCI            100096           Jul. 02, 2017    Jul. 01, 2018
     AMN/LISN                 R&S             ESH2-Z5           100086       Aug. 24, 2017       Aug. 23, 2018
                                                             AGC-CON03
 TEST SOFTWARE                 FR             EZ-EMC                                  --               --
                                                                 A

TEST EQUIPMENT OF RADIATED EMISSION TEST
    Equipment             Manufacturer         Model            S/N              Cal. Date         Cal. Due
 TEST RECEIVER                R&S              ESPI            101206        Jul. 02, 2017       Jul. 01, 2018
    ANTENNA           SCHWARZBECK           VULB9168            494         Sep. 27, 2017        Sep. 28, 2019
 TEST RECEIVER                R&S              ESCI            100694       June 29, 2017        June 28,2018

    ANTENNA           SCHWARZBECK           VULB9168          D69250        Sep. 27, 2017        Sep. 28, 2019

   POSITIONING
                               MF            MF-7802       MF780208285               --               --
  CONTROLLER
 HORN ANTENNA         ETS LINDGREN             3117          00034609       May. 17, 2017        May. 18, 2019


                                                                        Report No.: AGC02294180601FE08
                                                                                            Page 7 of 30

4. SUPPORT EQUIPMENT LIST


 Device Type        Manufacturer       Model Name         Serial No.    Data Cable      Power Cable

      --                  --                 --               --            --               --


5. SYSTEM DESCRIPTION

  EUT test procedure:

  1. Connect EUT and peripheral devices.
  2. Power on the EUT, the EUT begins to work.
  3. Make sure the EUT normal working.


                                            EMC TEST MODES


              No.                                     TEST MODES

               1                                        Scanning mode

               2                                  Scanning stopped/Receiving


 Note: Only the result of the worst case was recorded in the report.


                                                            Report No.: AGC02294180601FE08
                                                                                Page 8 of 30


6. SUMMARY OF TEST RESULTS

      FCC Rules              Description Of Test                         Result

       §15.107               Conduction Emission                       Compliant

       §15.109                Radiated Emission                        Compliant

       §15.111      Antenna Conducted Power for receivers              Compliant


                                                                      Report No.: AGC02294180601FE08
                                                                                          Page 9 of 30

7. FCC RADIATED EMISSION TEST

7.1. TEST EQUIPMENT OF RADIATED EMISSION

7.2. LIMITS OF RADIATED EMISSION TEST


            Frequency                   Distance                Maximum Field Strength Limit
               (MHz)                       (m)                          (dBuV/m/ Q.P.)
               30~88                        3                                41.0

              88~216                        3                                45.0

             216~960                        3                                48.0

             960~2000                       3                                53.5
     **Note: The lower limit shall apply at the transition frequency. Because the EUT RX frequency range
     up to 480 MHz, so the upper the frequency range up to 2 GHz.

7.3 BLOCK DIAGRAM OF RADIATED EMISSION TEST


                         RADIATED EMISSION TEST SETUP 30MHz-1000MHz


                                  Report No.: AGC02294180601FE08
                                                     Page 10 of 30

RADIATED EMISSION TEST SETUP ABOVE 1000MHz


                                                                         Report No.: AGC02294180601FE08
                                                                                            Page 11 of 30

7.4 PROCEDURE OF RADIATED EMISSION TEST

1) The equipment was set up as per the test configuration to simulate typical actual usage per the user’s
   manual. When the EUT is a tabletop system, a wooden turntable with a height of 0.8 meters is used which
   is placed on the ground plane as per ANSI C63.4 (see Test Facility for the dimensions of the ground plane
   used). When the EUT is floor-standing equipment, it is placed on the ground plane which has a 3-12 mm
   non-conductive covering to insulate the EUT from the ground plane.
2) Support equipment, if needed, was placed as per ANSI C63.4.
3) All I/O cables were positioned to simulate typical actual usage as per ANSI C63.4.
4) The EUT received power by AC 120V/60Hz.
5) The antenna was placed at 3 meter away from the EUT as stated in FCC Part 15. The antenna connected
   to the Analyzer via a cable and at times a pre-amplifier would be used.
6) The Analyzer / Receiver quickly scanned from 30MHz to 1000MHz. The EUT test program was started.
   Emissions were scanned and measured rotating the EUT to 360 degrees and positioning the antenna 1 to 4
   meters above the ground plane, in both the vertical and the horizontal polarization, to maximize the
   emission reading level.
7) The test mode(s) were scanned during the test:
8) Recorded at least the six highest emissions. Emission frequency, amplitude, antenna position, polarization
   and turntable position were recorded into a computer in which correction factors were used to calculate the
   emission level and compare reading to the applicable limit and Q.P./Peak reading is presented. For
   emissions below 1GHz, use 120KHz RBW and VBW>=3RBW for QP reading.
  9) For emissions above 1GHz, use 1MHz RBW and 3MHz VBW for peak reading. Then 1MHz RBW and
    10Hz VBW for average reading in spectrum analyzer.
  10) When the radiated emissions limits are expressed in terms of the average value of the emissions, and
    pulsed operation is employed, the measurement field strength shall be determined by averaging over one
    complete pulse train, including blanking intervals, as long as the pulse train does not exceed 0.1 seconds.
    As an alternative (provided the transmitter operates for longer than 0.1 seconds) or in cases where the
    pulse train exceeds 0.1 seconds, the measured field strength shall be determined from the average
    absolute voltage during a 0.1 second interval during which the field strength is at its maximum values.
  11)If the emissions level of the EUT in peak mode was 3 dB lower than the average limit specified, then
     testing will be stopped and peak values of EUT will be reported, otherwise, the emissions which do not
     have 3 dB margin will be repeated one by one using the quasi-peak method for below 1GHz.
  12) For testing above 1GHz, the emissions level of the EUT in peak mode was lower than average limit (that
    means the emissions level in peak mode also complies with the limit in average mode), then testing will be
    stopped and peak values of EUT will be reported, otherwise, the emissions will be measured in average
    mode again and reported.
  13) In case the emission is lower than 30MHz, loop antenna has to be used for measurement and the
     recorded data should be QP measured by receiver. High - Low scan is not required in this case.
    14) The test data of the worst case condition (mode 1) was reported on the following Data page


                                                                      Report No.: AGC02294180601FE08
                                                                                         Page 12 of 30

7.5 TEST RESULT OF RADIATED EMISSION TEST
                                             UV-82 (mode 1)
                           Radiated Emission Test –Horizontal -3m Below 1G




                                      Factor       Level      Limit
Frequency                  Reading                                     Margin               Height Angle
            Polarization                dB       dB(uV/m) dB(uV/m)              Pass/Fail
  MHz                      dB(uV)                                        dB                  cm     deg
                                      (1/m)         PK        QP
 80.925          H          10.4       12.3        22.7       40.0       17.3     Pass      200.0   303.2
 102.750         H          11.4       13.8        25.2       43.5       18.3     Pass      150.0   10.2
 129.425         H          12.3       16.2        28.5       43.5       15.0     Pass      200.0   288.5
 515.970         H           6.5       23.2        29.7       46.0       16.3     Pass      150.0   231.2
 825.400         H           7.2       29.2        36.4       46.0       9.6      Pass      200.0   37.4
 988.845         H           7.1       31.0        38.1       54.0       15.9     Pass      100.0   285.8

RESULT: PASS


                                                                       Report No.: AGC02294180601FE08
                                                                                          Page 13 of 30


                              Radiated Emission Test –Vertical -3m Below 1G




                                        Factor      Level      Limit
Frequency                  Reading                                      Margin               Height Angle
            Polarization                  dB      dB(uV/m) dB(uV/m)              Pass/Fail
   MHz                      dB(uV)                                        dB                     cm   deg
                                         (1/m)       PK         QP
  77.530         V           14.8        12.5       27.3        40.0      12.7     Pass      100.0    37.4
 128.455         V           13.3        16.1       29.4        43.5      14.1     Pass      100.0    247.1
 236.125         V            7.1        16.1       23.2        46.0      22.8     Pass      100.0    359.0
 595.510         V            7.9        24.9       32.8        46.0      13.2     Pass      100.0    34.4
 636.735         V            7.3        25.5       32.8        46.0      13.2     Pass      150.0    166.2
 998.545         V            6.4        31.1       37.5        54.0      16.5     Pass      150.0    305.6


RESULT: PASS
Note: 1. Factor=Antenna Factor + Cable loss - Amplifier gain, Margin=Measurement-Limit.
      2. The “Factor” value can be calculated automatically by software of measurement system.
      3. Emissions range from 1GHz to 2GHz have 20dB margin. No recording in the test report.
      4. Only the data of the worst case would be record in this test report.


                                                                      Report No.: AGC02294180601FE08
                                                                                         Page 14 of 30


                                              GT-5 (mode 1)
                           Radiated Emission Test –Horizontal -3m Below 1G




                                      Factor       Level      Limit
Frequency                  Reading                                     Margin               Height Angle
            Polarization                dB       dB(uV/m) dB(uV/m)              Pass/Fail
  MHz                      dB(uV)                                        dB                  cm     deg
                                      (1/m)         PK        QP
 79.470          H          12.4       12.3         24.7      40.0       15.3     Pass      200.0   309.3
 127.000         H          12.9       16.0         28.9      43.5       14.6     Pass      150.0   258.5
 158.040         H           7.7       16.6         24.3      43.5       19.2     Pass      200.0   263.3
 233.700         H           7.0       16.0         23.0      46.0       23.0     Pass      100.0   243.3
 598.905         H           7.1       24.9         32.0      46.0       14.0     Pass      100.0   128.9
 979.630         H           6.4       30.9         37.3      54.0       16.7     Pass      200.0   312.5

RESULT: PASS


                                                                       Report No.: AGC02294180601FE08
                                                                                          Page 15 of 30


                              Radiated Emission Test –Vertical -3m Below 1G




                                        Factor      Level      Limit
Frequency                  Reading                                      Margin               Height Angle
            Polarization                  dB      dB(uV/m) dB(uV/m)              Pass/Fail
   MHz                      dB(uV)                                        dB                     cm   deg
                                         (1/m)       PK         QP
  74.135         V           12.4        13.2       25.6        40.0      14.4     Pass      100.0    120.7
 128.455         V           12.0        16.1       28.1        43.5      15.4     Pass      100.0    231.7
 350.585         V            6.2        18.9       25.1        46.0      20.9     Pass      150.0    182.5
 518.880         V            6.1        23.2       29.3        46.0      16.7     Pass      150.0    229.9
 672.625         V            7.0        25.9       32.9        46.0      13.1     Pass      100.0    308.1
 999.030         V            6.0        31.1       37.1        54.0      16.9     Pass      100.0    68.1


RESULT: PASS
Note: 1. Factor=Antenna Factor + Cable loss - Amplifier gain, Margin=Measurement-Limit.
      2. The “Factor” value can be calculated automatically by software of measurement system.
      3. Emissions range from 1GHz to 2GHz have 20dB margin. No recording in the test report.
      4. Only the data of the worst case would be record in this test report.


                                                                             Report No.: AGC02294180601FE08
                                                                                                Page 16 of 30

8. CONDUCTED EMISSION TEST
8.1 PROVISIONS APPLICABLE
    For an intentional radiator that is designed to be connected to the public utility (AC) power line, the, the
    radio frequency voltage that is conducted back onto the AC power line on any frequencies within the band
    150 KHz to 30 MHz shall not exceed the limits in the following table, as measured using a 50uH/50 ohms
    line impedance stabilization network (LISN). Compliance with the provisions of this paragraph shall be
    based on the measurement of the radio frequency voltage between each power line and ground at the
    power terminal. The lower limit applies at the boundary between the frequencies ranges.

                                                                        Conducted Limit(dBuV)
              Frequency of Emission (MHz)
                                                               Quasi-Peak                  Average
                        0.15 – 0.5                              66 to 56 *                 56 to 46 *
                         0.5 – 5                                   56                           46
                          5 – 30                                   60                           50
   * Decreases with the logarithm of the frequency.

8.2 MEASUREMENT PROCEDURE
     (1) The equipment was set up as per the test configuration to simulate typical actual usage per the user’s
          manual. When the EUT is a tabletop system, a wooden table with a height of 0.8 meters is used and
          is placed on the ground plane as per ANSI C63.4 (see Test Facility for the dimensions of the ground
          plane used). When the EUT is a floor-standing equipment, it is placed on the ground plane which has
          a 3-12 mm non-conductive covering to insulate the EUT from the ground plane.
    (2) Support equipment, if needed, was placed as per ANSI C63.4.
    (3) All I/O cables were positioned to simulate typical actual usage as per ANSI C63.4.
    (4) The EUT received AC 120V/60Hz power through a Line Impedance Stabilization Network (LISN) which
         supplied power source and was grounded to the ground plane.
    (5) All support equipments received AC power from a second LISN, if any.
    (6) The EUT test program was started. Emissions were measured on each current carrying line of the EUT
         using a spectrum Analyzer / Receiver connected to the LISN powering the EUT. The LISN has two
         monitoring points: Line 1 (Hot Side) and Line 2 (Neutral Side). Two scans were taken: one with
         Line 1 connected to Analyzer / Receiver and Line 2 connected to a 50 ohm load; the second scan had
         Line 1 connected to a 50 ohm load and Line 2 connected to the Analyzer / Receiver.
    (7) Analyzer / Receiver scanned from 150 KHz to 30MHz for emissions in each of the test modes.
         During the above scans, the emissions were maximized by cable manipulation.


                               Report No.: AGC02294180601FE08
                                                  Page 17 of 30

8.3 TEST SETUP BLOCK DIAGRAM


  AG                        °s 7 I # m
                               Attestation of Global Compliance                                                       Report No.: AGCO02294180601FEO8
                                                                                                                                          Page 18 of 30

    8.4 TEST RESULT
                                                      CONDUCTED EMISSION TEST — LINE L




                                                                     I
                                                                     I
                                                                     —
                                                                     1                                                                  1
                                                                     1                                                                  1

                    150k           300k 400k        600k 800k 1M                       2M          3M      4M     5M 6M         8M 10M                    20M      30M
                                                                                   Frequency [Hz]




              MEASUREMENT RESULT:


                   Frequency              Level        Transd            Limit       Margin          Detector             Line          PE
                         Miz               aBuy            dB             dBuvy          dB

                     0.178000              43 .40          10   .0           €5          21.2        QP                   L1          FLO
                     0.23223000            39 .80          10   .1           63          22.9        QP                   L1          FLO
                     0.374000              36 .50          10   .1           €1          34.5        P                    L1          FLO
                     0. 326000              8 .50          10   .1           60          21.1        QP                   L1          FLO
                     0.450000              41 .30          10   .1           57          151.6       QP                   L1          FLO
                     0. 6423000            34.40           10   .1           56          21.6        QP                   L1          FLO




              MEASUREMENT RESULT:


                   Frequency              Level        Transd            Limit       Margin          Detector             Line          PE
                         MHz               aBuvy           dB             adBuVv         dB

                     0.178000              28 .10          10   .0           55          a6.5         AV                  L1          FLO
                     0.23223000            32 .00          10   .1           53          30.7        AV                   L1          FLO
                     0.290000              31.70           10   .1           51          28.8        AV                   L1          FLO
                     0. 334000             25.40           10   .1           49          214.0       AV                   L1          FLO
                     0.4223000             25 .90          10   .1           47          21.5        AV                   L1          FLO
                     0, 510000             35 .20          10   .1           146         20.8        AV                   L1          FLO




    RESULT: PASS




The results s 6tial
                O
                      fi%@)} treport refer only to the sample(s) tested unless otherwise stated and the sample(s) are retained for 30 days only. The document
is issued b     , this doc@énc it cannot be reproduced except in full with our prior written permission. The more details and the authenticity of the report will be


            ° AGC >
confirmed tfittp://www.agc-«& t.com.



Attestatiq ,2f Globa!Q o                              Tel: +86—755 2908 1955            Fax: +86—755 2600 8484             E—mail: agc@age—cert.com             @ 400 089 2118
                                                      Add: 2/F. , Building 2, No.1—4, Chaxi Sanwei Technical Industrial Park,Gushu, Xixiang, Bacan District, Shenzhen, Guangdong China


                            ®
                                     2                l
  A\G                           fistatfi;ar fl;a,
                                            %
                                               (i%pliafi;!
                                                 35
                                                                                                                     Report No.: AGC02294180601FEO8
                                                                                                                                                            Page 19 of 30

                                                        CONDUCTED EMISSION TEST — LINE N




              MEASUREMENT RESULT:


                   Frequency              Level       Transd          Limit         Margin           Detector            Line           FE
                              MHz           aBuv              dB        aBuv                cdB

                     0.182000             37 .70          10 .0             64          26.7          QP                 N           FLO
                     0.326000             3€6 .90         10.1              63          25.7          QP                 N           FLO
                     0.370000             34 .00          10.1              €1          27.1         QP                  N           FLO
                     0. 338000            32.70           10.1              59          26.6          QP                 N           FLO
                     0.454000             40.70           10.1              57          16.1         @QP                 N           FLO
                     0. 586000            35 .90          10.1              5€          20.1         QP                  N           FLO




              MEASUREMENT RESULT:


                   Frequency              Level       Transd          Limit         Margin           Detector            Line           PE
                              MHz           adBuvy            dB        adBuv               cdB

                     0.174000             36 .40          10 .0             55          28.4        RAV                  N           FLO
                     0. 2318000           31.20           10.1              53          31.7         RV                  N           FLO
                     0.346000             18.80           10.1              52          32.1        RAV                  N           FLO
                     0.330000             33 .50          10.1              50          37.0          AV                 N           FLO
                     0. 374000            21 .40          10.1               &          27.0        V                    N           FLO
                     0.463000             25 .30          10 .1             47          21.4        AV                   N           FLO




    RESULT: PASS




The results s‘ O virl fii@;}" kreport refer only to the sample(s) tested unless otherwise stated and the sample(s) are retained for 30 days only. The document
is issued b    , this doc@é it cannot be reproduced except in full with our prior written permission. The more details and the authenticity of the report will be


            ° AGC >
confirmed tfittp://www.agc-«& t.com.



Attestatic /2f Globa!Q ompliance                     Tel: +86—755 2908 1955            Fax: +86—755 2600 8484             E—mail: agc@age—cert.com             @ 400 089 2118
                                                     Add: 2/F. , Building 2, No.1—4, Chaxi Sanwei Technical Industrial Park,Gushu, Xixiang, Bacan District, Shenzhen, Guangdong China


                             ©
  A\G                                  3 7 h t i
                                                al            T    :n

                                       Attestation of Global Compliance
                                                                                                                             Report No.: AGC02294180601FEO8
                                                                                                                                                                    Page 20 of 30

    9. ANTENNA CONDUCTED POWER FOR RECEIVERS

    LIMIT

         The antenna conducted power of the receiver as defined in §15.111 shall not exceed the values given in the
         following tables


                         Frequency Range                                                                    9 KHz to 2GHz

                                           Limit                                                          2.0 nw (—57 dBm )


    TEST CONFIGURATION



                                                             EUT                                               Spectrum Analyzer



    TEST PROCEDURE

    1.    The receiver antenna terminal connected to a spectrum analyzer.
    2.    The test data of the worst case condition (mode 1) was reported on the following Data page.




The results ’m,6tison|
                  o thisfeaost report refer only to the sample(s) tested unless otherwise stated and the sample(s) are retained for 30 days only. The document
is issued by/A C§€ this docu/m it cannot be reproduced except in full with our prior written permission. The more details and the authenticity of the report will be
confirmed tfittp://www.agc-% t.com.
            o

Attestatic m                     ® )        i                Tel: +86—755 2908 1955            Fax: +86—755 2600 8484             E—mail: agc@age—cert.com             @ 400 089 2118
                           iN¥                               Add: 2/F. , Building 2, No.1—4, Chaxi Sanwei Technical Industrial Park,Gushu, Xixiang, Bacan District, Shenzhen, Guangdong China


                                                  Report No.: AGC02294180601FE08
                                                                     Page 21 of 30


TEST RESULTS
               Conducted Measurement (9 KHz to 150 KHz)




               Conducted Measurement (150 KHz to 30MHz)


                                        Report No.: AGC02294180601FE08
                                                           Page 22 of 30


       Conducted Measurement (30MHz to 1GHz)




       Conducted Measurement (1GHz to 2GHz)




PASS


                                 Report No.: AGC02294180601FE08
                                                    Page 23 of 30

APPENDIX 1 PHOTOGRAPHS OF TEST SETUP
     CONDUCTED EMISSION TEST SETUP




      RADIATED EMISSION TEST SETUP


                            Report No.: AGC02294180601FE08
                                               Page 24 of 30

APPENDIX 2 PHOTOGRAPHS OF EUT
        TOTAL VIEW OF EUT




         TOP VIEW OF EUT


                     Report No.: AGC02294180601FE08
                                        Page 25 of 30


BOTTOM VIEW OF EUT




FRONT VIEW OF EUT


                   Report No.: AGC02294180601FE08
                                      Page 26 of 30


BACK VIEW OF EUT




LEFT VIEW OF EUT


                     Report No.: AGC02294180601FE08
                                        Page 27 of 30


RIGHT VIEW OF EUT




OPEN VIEW-1 OF EUT


                         Report No.: AGC02294180601FE08
                                            Page 28 of 30


INTERNAL VIEW-1 OF EUT




INTERNAL VIEW-2 OF EUT


                         Report No.: AGC02294180601FE08
                                            Page 29 of 30


INTERNAL VIEW-3 OF EUT




INTERNAL VIEW-4 OF EUT


                          Report No.: AGC02294180601FE08
                                             Page 30 of 30


 INTERNAL VIEW-5 OF EUT




----END OF REPORT----



Document Created: 2018-06-25 10:50:04
Document Modified: 2018-06-25 10:50:04

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC