Test Report

FCC ID: 2AJ9T-TL400B

Test Report

Download: PDF
FCCID_3682010

                                                                     Access to the World



          ELECTROMAGNETIC EMISSIONS COMPLIANCE REPORT
            INTENTIONAL RADIATOR CERTIFICATION TO
                FCC PART 15 SUBPARTC REQUIREMENT
                                         OF




                               Fingerprint Lock

                             MODEL No.: TL400B

                             FCC ID: 2AJ9T-TL400B

                               Trademark: N/A

                        REPORT NO: ES171027979W02

                        ISSUE DATE: November 27, 2017



                                   Prepared for
                           ZKTECO CO., LTD.
    No.26, Pingshan 188 Industry zone, Tangxia Town, Dongguan City,
                      Guangdong Province, China



                                   Prepared by
                        EMTEK(SHENZHEN) CO., LTD.

              Bldg 69, Majialong Industry Zone, Nanshan District,
                        Shenzhen, Guangdong, China
                              TEL: 86-755-26954280
                              FAX: 86-755-26954282




TRF No:FCC 15C/A               Page 1 of 17       Report No: ES171027979W02 Ver.1.0


VERIFICATION OF COMPLIANCE
Applicant:                     ZKTECO CO., LTD.
                               No.26, Pingshan 188 Industry zone, Tangxia Town, Dongguan City, Guangdong
                               Province, China
Manufacturer:                  ZKTECO CO., LTD.
                               No.26, Pingshan 188 Industry zone, Tangxia Town, Dongguan City, Guangdong
                               Province, China
Product Name:                  Fingerprint Lock

Model Number:                  TL400B

Serial Number:                 N/A

File Number:                   ES171027979W02


We hereby certify that:
The above equipment was tested by EMTEK(SHENZHEN) CO., LTD.. The test data, data evaluation, test
procedures, and equipment configurations shown in this report were made in accordance with the procedures
given in ANSI C63.10 (2013) and the energy emitted by the sample EUT tested as described in this report is in
compliance with conducted and radiated emission limits of FCC Rules Part 15.207&15.209.

The test results of this report relate only to the tested sample identified in this report.


     Date of Test                      :          October 27, 2017 to November 27, 2017



     Prepared by                        :
                                                              Sevin Li/Editor



     Reviewer                           :
                                                            Joe Xia/Supervisor



     Approved & Authorized Signer :
                                                           Lisa Wang/Manager


                                                                                                                                               Access to the World


                                                                 Table of Contents

1.             GENERAL INFORMATION .................................................................................................................... 4

     1.1       PRODUCT DESCRIPTION ............................................................................................................................. 4
     1.2       RELATED SUBMITTAL(S) / GRANT (S) .......................................................................................................... 4
     1.3       TEST METHODOLOGY................................................................................................................................. 4
     1.4       SPECIAL ACCESSORIES .............................................................................................................................. 4
     1.5       EQUIPMENT MODIFICATIONS....................................................................................................................... 4
     1.6       TEST FACILITY ........................................................................................................................................... 5
2.             SYSTEM TEST CONFIGURATION ........................................................................................................ 6

     2.1       EUT CONFIGURATION ................................................................................................................................ 6
     2.2       EUT EXERCISE.......................................................................................................................................... 6
     2.3       TEST PROCEDURE ..................................................................................................................................... 6
     2.4       LIMITATION ................................................................................................................................................ 6
3.             SUMMARY OF TEST RESULTS ............................................................................................................ 7
4.             CONDUCTED EMISSION TEST ............................................................................................................. 8

     4.1 APPLICABLE STANDARD .................................................................................................................................. 8
     4.2 CONFORMANCE LIMIT ...................................................................................................................................... 8
     4.3 TEST CONFIGURATION .................................................................................................................................... 8
     4.4 TEST PROCEDURE .......................................................................................................................................... 8
     4.5 MEASUREMENT EQUIPMENT USED: .................................................................................................................. 8
     4.6 TEST RESULT ................................................................................................................................................. 9
5.             RADIATED EMISSION TEST ............................................................................................................... 10

     5.1       MEASUREMENT PROCEDURE .................................................................................................................... 10
     5.2       TEST SET-UP (BLOCK DIAGRAM OF CONFIGURATION) .............................................................................. 11
     5.3       MEASUREMENT EQUIPMENT USED: ........................................................................................................... 11
     5.4 MEASUREMENT RESULT .............................................................................................................................. 12
6.             ANTENNA APPLICATION ................................................................................................................... 17

     ANTENNA REQUIREMENT..................................................................................................................................... 17
     RESULT .............................................................................................................................................................. 17




TRF No:FCC 15.247/A                                                     Page 3 of 17                                  Report No: ES171027986W02 Ver.1.0


                                                                                       Access to the World


 1. GENERAL INFORMATION

    1.1 Product Description

          Characteristics                Description

          EUT Description                Fingerprint Lock

          Model Number                   TL400B

          Device style                   RFID

          Modulation                     ASK

          Operating Frequency
                                         125kHz
          Range

          Number of Channels             1

          Antenna Type                   Coil Antenna

          Antenna Gain                   0dBi

          Power supply                       DC 6V via 4*AA Batteries




    1.2 Related Submittal(s) / Grant (s)
        This submittal(s) (test report) is intended for FCC ID: 2AJ9T-TL400B filing to comply with Section
        15.207&15.209 of the FCC Part 15 Subpart C Rules.



    1.3 Test Methodology
        Both conducted and radiated testing was performed according to the procedures in ANSI C63.10
        (2013) and Radiated testing was performed at an antenna to EUT distance 3 meters.




    1.4 Special Accessories

        Not available for this EUT intended for grant.



    1.5 Equipment Modifications
        Not available for this EUT intended for grant.




TRF No:FCC 15.247/A                           Page 4 of 17              Report No: ES171027986W02 Ver.1.0


                                                                                   Access to the World




    1.6 Test Facility

       Site Description
       EMC Lab.           : Accredited by CNAS, 2016.10.24
                            The certificate is valid until 2022.10.28
                            The Laboratory has been assessed and proved to be in compliance
                            with CNAS-CL01: 2006(identical to ISO/IEC17025: 2005)
                            The Certificate Registration Number is L2291

                          : Accredited by TUV Rheinland Shenzhen, 2010.5.25
                            The Laboratory has been assessed according to the requirements
                            ISO/IEC 17025.
                          : Accredited by FCC, August 03, 2017
                            Designation Number: CN1204
                            Test Firm Registration Number: 882943

                          : Accredited by Industry Canada, November 24, 2015
                            The Certificate Registration Number is 4480A-2




TRF No:FCC 15.247/A                     Page 5 of 17                Report No: ES171027986W02 Ver.1.0


                                                                                              Access to the World


 2. System Test Configuration

    2.1 EUT Configuration
        The EUT configuration for testing is installed on RF field strength measurement to meet the
        Commissions requirement and operating in a manner which intends to maximize its emission
        characteristics in a continuous normal application.


    2.2 EUT Exercise
        The Transmitter was operated in the normal operating mode. The TX frequency was fixed which was
        for the purpose of the measurements.




    2.3 Test Procedure

        2.3.1 Radiated Emissions
               The EUT is a placed on as turn table which is 0.8 m above ground plane. The turn table shall
               rotate 360 degrees to determine the position of maximum emission level. EUT is set 3m away
               from the receiving antenna which varied from 1m to 4m to find out the highest emission. And
               also, each emission was to be maximized by changing the polarization of receiving antenna
               both horizontal and vertical. In order to find out the max. emission, the relative positions of this
               hand-held transmitter(EUT) was rotated through three orthogonal axes according to the
               requirements in Section 13.1.4.1 of ANSI C63.10-2013.



    2.4 Limitation
        (1) Radiated Emission

           FCC Part 15, Subpart C Section 15.209 limit of radiated emission for frequency below 1000GHz.
             The emissions from an intentional radiator shall not exceed the field strength level specified in
             the following table:
              Frequency                   Field strength            Distance(m)            Field strength at 3m
                 (MHz)                         V/m                                              dBV/m
              0.009~0.490                  2400/F(KHz)                   300                  See the remark
              0.490~1.705                  2400/F(KHz)                    30
               1.705~30.0                        30                       30
                   30-88                        100                        3                         40
                  88-216                        150                        3                        43.5
                  216-960                       200                        3                         46
               Above 960                        500                        3                         54

        Remark:    1. Emission level in dBuV/m=20 log (uV/m)
                   2. Measurement was performed at an antenna to the closed point of EUT distance of
                   meters.
                   3. Distance extrapolation factor =40log(Specific distance/ test distance)( dB);
                   Limit line=Specific limits(dBuV) + distance extrapolation factor.


TRF No:FCC 15.247/A                          Page 6 of 17                      Report No: ES171027986W02 Ver.1.0


                                                                                    Access to the World




 3. Summary of Test Results
                FCC Rule                       Description Of Test                 Result
                 15.207                   AC Power Conducted Emission              N/ANote

                 15.209                         Radiated Emission                   Pass

   Note: The EUT power supply is DC 6V via 4*AA batteries




TRF No:FCC 15.247/A                      Page 7 of 17                Report No: ES171027986W02 Ver.1.0


                                                                                             Access to the World


 4. CONDUCTED EMISSION TEST

     4.1 Applicable Standard
According to FCC Part 15.207(a)


     4.2 Conformance Limit
                                     Conducted Emission Limit
           Frequency(MHz)                           Quasi-peak                  Average
               0.15-0.5                                66-56                      56-46
                0.5-5.0                                  56                        46
               5.0-30.0                                  60                        50
Note: 1. The lower limit shall apply at the transition frequencies
       2. The limit decreases in line with the logarithm of the frequency in the range of 0.15 to
          0.50MHz.


     4.3 Test Configuration
Test according to clause 7.3 conducted emission test setup


     4.4 Test Procedure
The EUT was placed on a table which is 0.8m above ground plane.
Maximum procedure was performed on the highest emissions to ensure EUT compliance.
Repeat above procedures until all frequency measured were complete.


     4.5 Measurement Equipment Used:
   EQUIPMENT                   MFR              MODEL             SERIAL           LAST CAL.          Due. CAL
       TYPE                                    NUMBER            NUMBER
   Test Receiver        Rohde & Schwarz         ESCS30          828985/018       May 20, 2017       May 19, 2018
      L.I.S.N.            Schwarzbeck          NNLK8129          8129203         May 20, 2017       May 19, 2018
 50Ω Coaxial Switch          Anritsu             MP59B            M20531              N/A                 N/A




TRF No:FCC 15.247/A                           Page 8 of 17                   Report No: ES171027986W02 Ver.1.0


                                                                                       Access to the World




    4.6 Test Result

        N/A
        The EUT power supply is DC 6V via 4*AA batteries, So this test item is not applicable.




TRF No:FCC 15.247/A                        Page 9 of 17                Report No: ES171027986W02 Ver.1.0


                                                                                   Access to the World


 5. Radiated Emission Test


    5.1 Measurement Procedure

1. The EUT was placed on a turn table which is 0.8m above ground plane.
2. Maximum procedure was performed on the six highest emissions to ensure EUT compliance.
3. And also, each emission was to be maximized by changing the polarization of receiving antenna both
   horizontal and vertical.
4. Repeat above procedures until all frequency measured was complete.

   When spectrum scanned from 9KHz to 150KHz setting resolution bandwidth 200Hz and video bandwidth
   1kHz.
   EMI Test Receiver         Setting
   Attenuation               Auto
   RB                        200Hz
   VB                        1kHz
   Detector                  QP
   Trace                     Max hold

   When spectrum scanned from 150KHz to 30MHz setting resolution bandwidth 9 kHz and video bandwidth
   30kHz.
   EMI Test Receiver         Setting
   Attenuation               Auto
   RB                        9kHz
   VB                        30kHz
   Detector                  QP
   Trace                     Max hold

   When spectrum scanned from 30 MHz to 1GHz setting resolution bandwidth 120 kHz and video bandwidth
   300kHz.
   EMI Test Receiver          Setting
   Attenuation                Auto
   RB                         120kHz
   VB                         300kHz
   Detector                   QP
   Trace                      Max hold




TRF No:FCC 15.247/A                      Page 10 of 17               Report No: ES171027986W02 Ver.1.0


                                                                                        Access to the World




    5.2 Test SET-UP (Block Diagram of Configuration)
       (A) Radiated Emission Test Set-Up, Frequency Below 30MHz



               Turntable                       3m
                               EUT

                                                                                                 Test
                                           0.8 m
                                                                                                Receiver

               Ground Plane                                     Coaxial Cable



     (B) Radiated Emission Test Set-Up, Frequency Below 1000MHz




                                                   3m

                       Turntable
                                                                                              1m to 4m
                                     EUT
               Spectrum
               Analyzer                                 0.8m


                     Ground Plane                                            Coaxial Cable




    5.3 Measurement Equipment Used:

  EQUIPMENT                   MFR             MODEL           SERIAL            LAST CAL.           DUE CAL.
      TYPE                                   NUMBER          NUMBER
 EMI Test Receiver     Rohde & Schwarz          ESU        1302.6005.26      May 21, 2017         May 20, 2018
   Pre-Amplifier             HP                8447F        2944A07999       May 20, 2017         May 19, 2018
  Bilog Antenna          Schwarzbeck        VULB9163            142          May 20, 2017         May 19, 2018
  Loop Antenna              ARA             PLA-1030/B         1029          May 20, 2017         May 19, 2018
  Horn Antenna           Schwarzbeck        BBHA 9170      BBHA9170399       May 21, 2017         May 20, 2018
  Horn Antenna           Schwarzbeck        BBHA 9120          D143          May 20, 2017         May 19, 2018
      Cable              Schwarzbeck          AK9513          ACRX1          May 21, 2017         May 20, 2018
      Cable              Rosenberger            N/A           FP2RX2         May 21, 2017         May 20, 2018
      Cable              Schwarzbeck          AK9513          CRPX1          May 21, 2017         May 20, 2018
      Cable              Schwarzbeck          AK9513          CRRX2          May 21, 2017         May 20, 2018




TRF No:FCC 15.247/A                        Page 11 of 17                  Report No: ES171027986W02 Ver.1.0


                                                                                         EMITEK
           5.4      Measurement Result

 Note: the amplitude of spurious emission that is attenuated by more than 20dB below the permissible
 Limit.
       Operation Mode:             ON                       Test Date :       November 12, 2017
       Frequency Range:            9KHz~30MHz               Temperature :     24°C
       Test Result:                PASS                     Humidity :        53 %
       Measured Distance:          3m                       Test By:          KK
      X:
140.0        dBuv
                                                                                           Limit1:     ——
130

120

110

100

90

80

70

60

50

40

30
20.0
   0.003                                         (MHz]                                                 0.150
120.0 dBu¥/m


110

100

90

80

70

60

50

40

30

20

10
0.0
     0.150                   0.5                 (MHz]                 5                               30.000


TRF No : FCC 15.247/A                       Page 12 of 17                   Report No: ES171027986W02 Ver.1.0


                                                               EMITEK
¥:
140.0 dBuy
                                                                 Limit1:   ——
130                                                              Margin:   «——

120

110

100

90

so
zo
so
50

40
30
20.0
     0.003                         (MHz]                                   0.150

120.0        dBu¥/m
                                                                 Limit1:   —
110                                                              Margin:   i«

100

90

80

70

60

50

40

30

20

10
0.0
     0.150              0.5        (MHz]      5                            30.000




TRF No : FCC 15.247/A         Page 13 of 17       Report No: ES171027986W02 Ver.1.0


                                                                                             EMITEK
Z:
140.0 aBuy
                                                                                               Limit1:   =——
130                                                                                            Margin:   w«

120

110

100

90

80

70

60

50

40

30
20.0
   0.003                                             (MHz]                                               0.150
120.0 dBu¥/m


110                                                                                            Margin:   «——

100

90

80

70

60

50

40

30

20

10
0.0
     0.150                   0.5                     (MHz]               5                               30.000
       Note: the Fundamental Emission is less than the spurious emission Limit, the bandage test is not need.




TRF No : FCC 15.247/A                           Page 14 of 17                  Report No: ES171027986W02 Ver.1.0


                                                                                                                 EMITEK
  Operation Mode:                           ON                            Test Date :              November 12, 2017
  Frequency Range:                          30~1000MHz                    Temperature :            24°C
  Test Result:                              PASS                          Humidity :               53 %
  Measured Distance:                        3m                            Test By:                 KK
        80.0     dBu¥/m
                                                                                                                Limitl:    ——
                                                                                                                Margim:    —
        70


        60



        50



        w L__LO_L_LLLFr———



             20.000     40      5o   60 70 00                     CIS]                  a00       400     500 600 700      1000.000
   Site 3m Chamber #3                                                Polarization:    Horizontal               Temperature:     24 C
   Limit: (RE)FCC PART 15 CLASS B                                        Power:    DC 6V                       Humidity:        53%
   Mode: 125KHz TX
   Note:


                               Reading       Correct   Measure—                                  Antenna     Table
   No. Mk.            Freq.     Level        Factor     ment      Limit     Over                 Height    Degree
                      MHz        dBuv         08       dBuV/im    dBuV/im    dB       Detector     m        degree   Comment
    1           36.0007          30.67      —16.54      14.13      40.00 —25.87            OP
    2           56.0007          29.95      —14.69      15.26      40.00 —24.74            OP
    $           80.9274          26.82       —16.50     10.32      40.00 —29.68            OP
    4          111.7380          25.98       —16.00      9.98      4350 —33.52         OP
    6          333.6865          26.01      —11.18      14.83       46.00 —31.17       OP
    6 *        625.0780          26.49       4.80       21.69      46.00 —24.31        P




  *:Maximum data              x:Overlimit     Fover margin                                                 Operator:. LQZ


TRF No : FCC 15.247/A                                     Page 15 of 17                           Report No: ES171027986W02 Ver.1.0


                                                                                                             EMITEK
       80.0    dBu¥/m
                                                                                                                Limit1:   —
                                                                                                                Margin:   —
       70


       co


       50


       we T
          TT—————H


       ksscT
        20000  40
 Site 3m Chamber #3
                    5o 60 70 90

 Limit: (RE)FCC PART 15 CLASS B
                                                                (MHz)
                                                                   Polarization: Vemcal
                                                                      Power: DC 6V
                                                                                                      soo    600 700
                                                                                                              Temperature:
                                                                                                              Humidity:
                                                                                                                          1000.000
                                                                                                                               24C
                                                                                                                               53 %
 Mode: 125KHz TX
 Note:

                          Reading        Correct   Measure—                                Antenna Table
 No. Mk.         Freq.     Level         Factor     ment      Limit      Over              Height   Degree
                 MHz        dBuy          dB       dBuVim     dBuVim      dB    Detector     cm     degree    Comment
   1           36.0007      28.21       —16.54      11.67     40.00 —28.33       P
   2          43.6584       26.30       —14.24      12.06     40.00 —27.94        OP
   3           56.3947      27.82       —14.83      12.99     40.00 —27.01       P
   4           78.1388      3243        —19.83      12.60     40.00 —27.40       P
   5          104.1701      26.24       —15.61      10.63     43.50 —3287         OP
   6 * 687.1506             27.35        —3.92      2343      46.00 —22.57       OP




 *:Maximum data          x:Over limit     Fover margin                                              Operator:     LQZ




TRF No : FCC 15.247/A                                    Page 16 of 17                       Report No: ES171027986W02 Ver.1.0


                                                                                             Access to the World


  6. Antenna Application

     Antenna Requirement

              Standard                                             Requirement
                                   An intentional radiator shall be designed to ensure that no antenna other
                                   than that furnished by the responsible party shall be used with the
                                   device. The use of a permanently attached antenna or of an antenna
                                   that uses a unique coupling to the intentional radiator shall be
                                   considered sufficient to comply with the provisions of this section. The
                                   manufacturer may design the unit so that a broken antenna can be
                                   replaced by the user, but the use of a standard antenna jack or electrical
                                   connector is prohibited. This requirement does not apply to carrier
        FCC CRF Part 15.203
                                   current devices or to devices operated under the provisions of §15.211,
                                   §15.213, §15.217, §15.219, or §15.221. Further, this requirement does
                                   not apply to intentional radiators that must be professionally installed,
                                   such as perimeter protection systems and some field disturbance
                                   sensors, or to other intentional radiators which, in accordance with
                                   §15.31(d), must be measured at the installation site. However, the
                                   installer shall be responsible for ensuring that the proper antenna is
                                   employed so that the limits in this part are not exceeded.


For intentional device, according to FCC 47 CFR Section 15.203, an intentional radiator shall be designed to
ensure that no antenna other than that furnished by the responsible party shall be used with the device. if
transmitting antennas of directional gain greater than 6dBi are used, the power shall be reduced by the amount
in dB that the directional gain of the antenna exceeds 6dBi.



Result
The EUT’S antenna is coil antenna, The antenna’s gain is 0dBi and meets the requirement. and the antenna
can’t be replaced by the user,which in accordance to section 15.203.
The antenna dimension: 0.02*2+0.04*2=0.12m<0.625*λ(0.625*c/f=1500m), the detail see the internal Photo.




TRF No:FCC 15.247/A                           Page 17 of 17                  Report No: ES171027986W02 Ver.1.0



Document Created: 2017-12-18 13:32:37
Document Modified: 2017-12-18 13:32:37

© 2024 FCC.report