RF exposure

FCC ID: 2AJ9T-ALZ

RF Exposure Info

Download: PDF
FCCID_4144222

                                         FCC ID: 2AJ9T-ALZ

Portable device
According to §15.247(e)(i) and §1.1307(b)(1), systems operating under the provisions of this
section shall be operated in a manner that ensures that the public is not exposed to radio
frequency energy level in excess of the Commission’s guidelines.
According to KDB447498 D01 General RF Exposure Guidance V06
For 100 MHz to 6 GHz and test separation distances ≤ 50 mm, the 1-g and 10-g SAR test
exclusion thresholds are determined by the following:
[(max. power of channel, including tune-up tolerance, mW) / (min. test separation distance, mm)] •
[√f(GHz)] ≤ 3.0 for 1-g SAR, and ≤ 7.5 for 10-g extremity SAR, where
         • f(GHz) is the RF channel transmit frequency in GHz
         • Power and distance are rounded to the nearest mW and mm before calculation
         • The result is rounded to one decimal place for comparison
         • The values 3.0 and 7.5 are referred to as numeric thresholds in step b)
The test exclusions are applicable only when the minimum test separation distance is ≤ 50 mm,
and for transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation
distance is < 5 mm, a distance of 5 mm according to 4.1 f) is applied to determine SAR test
exclusion.
Maximum measured transmitter power:
ZigBee:
                Transmit                       Tune-up
                               Measured                    Max tune-up        Result
   Mode        Frequency                        power                                       1-g SAR
                              Power (dBm)                  power(dBm)       calculation
                 (GHz)                          (dBm)
                 2.405            4.46           -5±1            6            1.2340          3.00
  GFSK           2.440            5.17           -5±1            6            1.2348          3.00
                 2.480            6.35           -6±1            7            1.5785          3.00

Conclusion:
For the max result 1.5785< 3.0 for 1-g SAR extremity SAR, No SAR is required.


Sincerely,




Zhonglie Ge/Engineer
ZKTECO CO., LTD.