Users Manual

FCC ID: 2AJ9T-AL20B

Users Manual

Download: PDF
FCCID_3952599

USER MANUAL
AL20B Fingerprint Lock with Touch Keypad
Version: 1.0
Date: November, 2017




                             1


                                              Table of Contents
Read Before Use ............................................................................................................ 1
      Safety Precautions .......................................................................................................................1
      Structure .............................................................................................................................................2
Basic Function ............................................................................................................... 3
      User Introduction .........................................................................................................................3
      Initialization ......................................................................................................................................4
      Random Password .......................................................................................................................4
      Voice Guide ......................................................................................................................................5
      Volume setting ...............................................................................................................................5
      Language setting .........................................................................................................................5
      Lockout mode ................................................................................................................................5
      Normal Open ..................................................................................................................................6
      Low Battery Warning ................................................................................................................. 6
      9V External Battery ......................................................................................................................7


      How to change handle direction ...................................................................................... 8
      Emergency Mechanical Key ................................................................................................. 9
How to Use .................................................................................................................. 10
      Register First Administrator ................................................................................................ 10
      Register Other Administrator ............................................................................................ 12
      Register Normal User .............................................................................................................. 13
      Delete Admin ............................................................................................................................... 14
      Delete Normal User ................................................................................................................. 15
      Back up enroll .............................................................................................................................. 16
      Volume setting ............................................................................................................................ 17
      Language setting ...................................................................................................................... 18
      Lockout mode ............................................................................................................................. 19
      Normal open mode ................................................................................................................. 20


Read Before Use
Safety Precautions
1. The factory setting of all new locks will allow ANY fingerprints to open them.
2. Please register at least one administrator for the newly installed lock. The lock cannot
   register any normal users without an administrator.
3. The lock is equipped with mechanical keys for manual unlocking. Please keep the
   mechanical keys at a safe place.
4. To power ON the lock, four alkaline AA batteries (not included) are required.
   Non-alkaline and rechargeable batteries ARE NOT RECOMMENDED.
5. Do not remove batteries when the lock is in working state.
6. Please replace the battery soon when the lock prompts of low battery.
7. If the lock does not have any activity for seven seconds it will go into sleep mode and
   prompts of time expired.
8. For best results, apply clean fingers to the fingerprint sensor.

                                          P a g e |1


Structure
               1
                                               5

               2
               3
                                               6
               4                                                    7

                                                                    8



1. Fingerprint Sensor                     5. Battery Area
2. Keypad & Card Detection Area           6. Louckout Switch
3. Mechanical Key Hole                    7. 9V Battery Interface
4. Handle                                 8. Speaker




                                  P a g e |2


Basic Function

User Introduction
          Group         Verification Mode                Function            Capacity

                            Fingerprint            Register / Delete User,   Max.100
   Administrator                                       Open The Door,
                             Password                  Access in menu        Max.100

                            Fingerprint                                      Max.100
    Normal User                                        Open the door
                             Password                                        Max.100


 Note:
     1.    The maximum fingerprint/password capacity is 100 for all groups.
     2.    The length of password is six digits.




                                          P a g e |3


Initialization
Initializing the lock means all data will be delete and restore to factory default setting.
Operation steps: Press the reset button on the back body of the lock, then touch the
keypad to power on the lock holding the reset button for 5 seconds until the lock
prompts the voice of “Restore to default settings, wait a moment”. After around 30
seconds, the lock prompts the voice of “completed”, and then the initialization is finished
completely.



Random Password
Random password = Users may enter any number of random digits before or after the
correct six digit password as long as the maximum number of digits entered is 32 or less.
For example: If the correct password is 123456, the random password can be
89123456807, 1234562363, 389123456, etc.



                                           P a g e |4


Voice Guide
After accessing the menu, the lock provides voice prompts before and after each
operation for easy configuration.

Volume Setting
The lock volume can be set, which has three modes, high volume mode, low volume
mode and silent mode.

Language Setting
Supports English / Spanish.or English / Portuguese.

Lockout Mode
When the lock set as lockout mode, only administrator can open the door, and also can
use the Lockout Switch to enable or disable the mode.



                                        P a g e |5


Normal Open
Normal open mode is to keep door always unlocked, which is fit for meeting room and
some places free to in or out.



Low Battery Warning
When the lock has a low battery a short beep and voice prompt of "Battery is low, please
replace" will be prompted".


Note: Access to menu steps is not allowed in low battery status.




                                        P a g e |6


9V External Battery
9V external battery is used to open doors in emergency.




Note: The above battery must be 9V alkaline battery (6LR61).



                                        P a g e |7


How To Change Handle Direction
1                   2                             3




4
                 Step:
                     1.    Remove the screws with a screwdriver.
                     2.    Take out the lock handle.
                     3.    Turn the handle in the opposite direction.
                     4.    Replace the screws.


                          P a g e |8


Emergency Mechanical Key
The mechanical key is used to open door when the lock has electronic malfunction.
Note: Keep the mechanical key at a safe place.




                                        P a g e |9


How to Use

Register First Administrator
                             Operating Steps
                   Touch the keypad to power ON the lock


                    Press 0 and # to access into menu


                         Enter 3 digit user number


                       Enter fingerprint or password



                                              Press # to continue
            Press * to complete
                                            registering another user




                                  P a g e | 10


Note:
    1.   Place one finger three times on fingerprint sensor to register fingerprint.
    2.   The length of password should be of six digits.
    3.   Default user number length is three digits, but one or two digit user numbers
         are accepted by pressing the # key.
    4.   Press * to cancel registration before the registration is complete.




                                         P a g e | 11


Register Other Administrator
                                    Operating Steps

                         Touch the keypad to power ON the lock


                           Press 0 and # to access into menu


                     Verify administrator by fingerprint or password


                     Press 1 to register user, and press # to continue


                                Enter 3 digit user number


                              Enter fingerprint or password



                                                     Enter # to continue
                  Enter * to complete
                                                  registering another admin



  Note: If you verify administrator by password, please end with button #.

                                        P a g e | 12


Register Normal User
                            Operating Steps
                  Touch the keypad to power on the lock

                   Press 0 and # to access into menu


              Verify administrator by fingerprint or password


             Press 2 to register user, and press # to continue


                      Enter fingerprint or password


                                               Enter # to continue
           Enter * to complete             registering another normal
                                                       user
                                                                        .




                                 P a g e | 13


Delete Admin
                              Operating Steps

                   Touch the keypad to power on the lock


                     Press 0 and # to access into menu


                Verify administrator by fingerprint or password


               Press 3 to delete admin, and press # to continue


                          Enter 3 digit user number


                                          Enter # to continue deleting
          Enter * to complete
                                                 another admin




                                  P a g e | 14


Delete Normal User
                                Operating Steps
                   Touch the keypad to power on the lock

                     Press 0 and # to access into menu


               Verify administrator by fingerprint or password


               Press 4 to delete user, and press # to continue


                         Enter 3 digit user number


                                         Enter # to continue deleting
          Enter * to complete
                                             another normal user




                                  P a g e | 15


Back Up Enroll
                               Operating Steps

                    Touch the keypad to power on the lock

                       Press 0 and # to access into menu


                 Verify administrator by fingerprint or password


             Press 5 to back up enroll, and press # to continue


                           Enter 3 digit user number

                         Enter fingerprint or passcode


                                            Enter # to continue backup
            Enter * to complete
                                               another information




                                   P a g e | 16


Volume Setting
                           Operating Steps

                 Touch the keypad to power on the lock

                   Press 0 and # to access into menu


             Verify administrator by fingerprint or password


             Press 6 to set volume, and press # to continue


             1. High volume 2. Low volume 3. Silent mode


                           Enter # to confirm




                               P a g e | 17


Language Setting
                                      Operating Steps

                           Touch the keypad to power on the lock

                             Press 0 and # to access into menu


                       Verify administrator by fingerprint or password


                      Press 7 to set language, and press # to continue


                            1. English 2. Spanish 3. Portuguese


                                      Enter # to confirm


Note: There are only two language mode, English/Spanish, or English/Portuguese. For
      example, if the lock is equipped with English/Spanish, selecting "3" (Portuguese),
      will still show Spanish mode.


                                         P a g e | 18


Lockout mode
                             Operating Steps


                   Press 0 and # to access into menu


               Verify administrator by fingerprint or password


          Press 8 to set lockout mode, and press # to continue


                            1. Enable 2. Disable


                             Enter # to confirm




                                 P a g e | 19


Normal open mode
                            Operating Steps

                  Touch the keypad to power on the lock


                   Press 0 and # to access into menu


              Verify administrator by fingerprint or password


         Press 9 to set normal open mode, and press # to continue


                          1. Enable 2. Disable


                            Enter # to confirm




                               P a g e | 20


Warning: Changes or modifications to this unit not expressly approved by the party responsible for
compliance could void the user’s authority to operate the equipment
Note: This equipment has been tested and found to comply with the?limits for a Class B digital device,
pursuant to Part 15 of the FCC Rules.These limits are designed to provide reasonable protection against
 harmful interference in a residential installation. This equipment generates,uses and can radiate radio
frequency energy and, if not installed and used in accordance with the instructions, may cause harmful
interference to radio communications. However, there is no guarantee that interference will not occur in a
 particular installation. If this equipment does cause harmful interference to radio or television reception,
 which can be determined by turning the equipment off and on, the user is encouraged to try to correct the
 interference by one or more?of the following measures:

 Reorient or relocate the receiving antenna
 Increase the separation between the equipment and receiver
 Connect the equipment into an outlet on a circuit different from that to which the receiver is connected
 Consult the dealer or an experienced radio/TV technician for help


“This equipment complies with FCC RF radiation exposure limits set forth for an uncontrolled environment.
 This equipment should be installed and operated with a minimum distance of 20 centimeters between the
 radiator and your body.”


ZK Building, Wuhe Road, Gangtou, Bantian, Buji Town,
Longgang District, Shenzhen China 518129
Tel: +86 755-89602345
Fax: +86 755-89602394
www.zkteco.com

© Copyright 2014. ZKTeco Inc. ZKTeco Logo is a registered trademark of ZKTeco or a related company. All other product and company
names mentioned are used for
                                                           P a g e | 21



Document Created: 2017-12-23 13:44:54
Document Modified: 2017-12-23 13:44:54

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC