                    * Standalone SAR test exclusion considerations



- Min. transmitting frequency                   =   2 480 MHz
- Min. test separation distance                 =   5 mm
-Max. Power with tune-up tolerance              =   -1.35 dBm     =   0.6531 mW
 (Measured Maximum power(Frame Average Output Power) = -1.85 dBm                               ± 0.5dB)




Step 1)
SAR Test exclusion thresholds for 100MHz to 6GHz at test separation distance            ≤ 50 mm =       Used
      [(max.power of channel, including tune-up torelance, mW)/(min. test separation distance, mm)] * [√f(GHz)]



 =[    0.6531   /   5   ]   * [ √ 2.480 ]   =   0.2057     ≤ 3, for 1g SAR


                                                           Thus, SAR for this device is not required.




Step 2)
SAR Test exclusion thresholds for 100MHz to 1500MHz at test separation distance               > 50 mm =     N/A
                [Threshold at 50mm in step 1) + (test separation distance - 50 mm) * (√f(MHz)/150] mW




Step 3)
SAR Test exclusion thresholds for 1500MHz to 6GHz at test separation distance > 50 mm                   =   N/A
                [Threshold at 50mm in step 1) + (test separation distance - 50 mm) * 10] mW