LAKE X USER MANUAL

FCC ID: 2AJ5K-LAKE-X

Users Manual

Download: PDF
FCCID_4505960

USER GUIDE


  Main Screen



Run Mode                                                   Set temperature
Shows current                                              Shows current
Run mode                                                   Set temperature
                                                           Room temperature
                                                           Shows current
                                                           room temoerature
Fan Status
Shows current
Fan status                                                  System Mode
                                                            Shows current
Humidity                                                    system mode
Shows current
Humidity                                                    Time
                                                            Shows current
                                                            time


                                                            WIFI
                                                            Shows current
                                                            WiFi status




  Specifications
     Temperature Sensor   SHT20
     Accuracy             ±1°C
     Temperature Range    Heating: 40°F – 90°F (4°C – 32°C)
                          Cooling: 50°F – 99°F (10°C – 37°C)
     Operating Temp/      0~45°C, 5~95% RH (non-condensing)
     Humidity Range
     Screen Resolution    320x480 TFT LCD
     Power Supply         AC 24V
     Size                 100x100x20 mm
     Housing Material     PC
     IP Rank              IP20
     WiFi                 2.4GHz only

                                1


Thermostat Functions

 Functions                 Descriptions
 System Modes              Off, Heat, Cool, Auto, Emergency
 Fan                       Auto, On
 Run Modes                 Timing, Eco, Away, Hold, Temporary
 Room Temperature          Detects the current room temperature.
 Display
 Humidity Display          Detects the room humidity level
 Compressor Protection     Controls the start and stop time intervals of
                           the compressor.
 WiFi Connection           Direct WiFi connection for updates and app
                           access.
 Timing Programming        User can preset a temperature value or
                           range to start at a certain time and day(s).
                           The timing program will continue until the
                           next schedule or when overwritten by
                           another mode/program.
 Away Mode                 Energy saving mode when you’re away from
                           home. Recommended to preset a wide
                           temperature range.
 ECO Mode                  Energy saving mode when you’re home or
                           away. Recommended to have a smaller
                           preset range than your Away mode.
 Filter Monitor            Reminds you when it’s time to change the
                           filter according to your preset timer.
 Key Lock                  Lock the controls to prevent others from
                           operating the thermostat.
 Pre-cooling/ Preheating   Calculates the best time period to execute
                           scheduled commands.




                                  2


App Pairing
    From the main screen, tap on        Then select the Parameters
         the settings icon.                       option.




    Swipe LEFT to get to the next       Swipe LEFT again to get to
             screen.                        the next screen.




     Follow the app download            Create your account and pair
    instructions on this screen.           the thermostat device.




                                    3


Symbol Guide
 Symbol          Name                Description

   @      soemmete       meggponnerten
   A      Standby/Main   Standby mode/ Main Screen

   @      Settings       Enter settings screen

    'fi    Away           Away mode activation

   &      EcO            ECO mode activation

          Off            Turns off all relay outputs

   $      Auto           System runs in Auto mode

   :      Heat           Heater activation

          Cool           AC activation
          Emergency      E}r]r:;grj:gcy heating for heat pump


   {1‘}   Timing         Timed schedules for preset temp

    &     Hold           Holding current set temperature

          Fan Auto       Fan runs automatically

          Fan On         Fan turns on

   KX     Parameters     Enter parameters screen

   >      WiFi           WiFi connectivity


Operations
1) System mode selection


In the main interface press      to enter the system mode selection

interface. You can switch the system mode by selecting OFF         , AUTO

     , HEAT       , COOL       and EMER         (heat pump only). After

selecting a mode, tap the check  button for it to take effect. When OFF

     is selected, the thermostat turns off all relay outputs.

Note that not all homes will have every mode option available and depends

on your HVAC system. The thermostat determines which modes are active

according to the HVAC system type.

2) View or modify the set temperature

In the main interface, when a system mode is selected the currently set

temperature is displayed directly above the screen. Press - or + touch pads

to adjust the set temperature value. When the task mode is in Timing mode,

the set temperature value will be automatically changed to a temporary hold.

In ECO or Away mode, the set temperature value cannot be adjusted under

the main interface. The temperature settings of ECO and Away are set in the

system parameter settings.


                                       5


3) Run mode selection

From the main interface, swiping left to the second page takes you to Run

Mode. To activate a Run Mode option, the thermostat System Mode cannot

be OFF. The Run Mode can be switched by selecting the TIMING          , ECO

    , AWAY       , and HOLD        icons.

   TIMING mode

   TIMING is in the system parameter settings. If no timing schedule is

   turned on, the default set temperature is executed. (The mode does not

   change automatically.) If the device is in TIMING mode, there will be an

   icon      displayed on the main interface screen.

   ECO mode

   This is an energy saving mode to use when you’re home or away. This

   mode will maintain the room temperature to stay within the preset

   cooling or heating temperature range. When activated, the ECO icon

   will display on the standby and main interface screens. The range can be

   adjusted within the Parameters settings, and it is recommended to have

   a smaller preset temperature range than your Away mode.




                                     6


AWAY mode

This is an energy saving mode to use when you’re away from home. This

mode will maintain the room temperature to stay within the preset

cooling or heating temperature range. When activated, the AWAY icon

     will display on the standby and main interface screens. The range

can be adjusted within the Parameters settings, and it is recommended

to have a larger preset temperature range than your ECO mode.

Hold mode

This mode will maintain the current set temperature. In the hold mode,

the icon      is displayed in the Task Mode position of the main

interface.

Temporary Mode

When the system is in the TIMING run mode, the thermostat can be

entered into the temporary mode by modifying the current set

temperature. The current set temperature will hold until the next timer

schedule takes effect. Temporary mode can be cancelled by selecting

another task mode.




                                   7


4) Fan mode selection

From the main interface, swiping left to the third page takes you to Fan

Mode. You can switch the fan mode by selecting the ON          or AUTO

icons. After clicking a mode, tap the submit button for your selection to take

effect. Note that some homes have no fans, so this option will not be

available depending on your HVAC system.

5) Settings

Press the settings icon     in the main interface to enter the Setting

selection interface. The available System mode options are WiFi          ,

Parameters       , and Timing     .

   WiFi – Setting WiFi

   WiFi setting interface as shown:




                                      8


Select your WiFi network name, enter your password, and connect to the

WiFi network. Also note that the WiFi icon   in the main interface

screen will appear when WiFi is connected.

Parameters Setting

The Parameter setting interface allows you to adjust your thermostat

with numerous different features and settings.




                                  9


        Parameter           Default Setting                   Ranges
1    Time/Date          2018-11-20 1:11AM
2    System Type        Heat only             Heat only conventional
                         conventional         Cool only conventional
                                              1 stage heat and cool conventional
                                              2 stage heat pump with Aux
                                              1 stage heat pump with Aux and Emer
                                              2 stage heat and cool conventional
                                              2 stage heat pump with Aux and Emer
                                              2 stage heat pump with Aux
3    Fan Control In     0                     0 - Thermostat control fan (default)
      Heating                                 1 - Equipment control fan
4    O/B Terminal       0                     0 - Directional valve opens with cooling
      Energized                                (default)
                                              1 - Reversing valve opens with heating
5    Away Heating       40℉ / 4℃              °F range: 40 - 90
      Temp                                    °C range: 4 - 32
6    Away Cooling       99℉ / 37℃             °F range: 50 - 99
      Temp                                    °C range: 10 - 37
7    ECO Heating        64℉ / 18℃             °F range: 40 - 90
      Temp                                    °C range: 4 - 32
8    ECO Cooling        79℉ / 26℃             °F range: 50 - 99
      Temp                                    °C range: 10 - 37
 9   Brightness         80                    Value range: 0 - 100
10   Dead band          2℉ / 1.5℃             °F range: 2 - 9
                                              °C range: 1.5 - 5
11   Temperature Unit   F                     °F - Fahrenheit
                                              °C - Celsius
12   1st Stage          2℉ / 1℃               °F range: 1 - 3
      Hysteresis                              °C range: 0.5 - 1.5
13   2nd Stage          2℉ / 1℃               °F range: 1 - 3
      Hysteresis                              °C range: 0.5 - 1.5
14   3rd Stage          2℉ / 1℃               °F range: 1 - 3
      Hysteresis                              °C range: 0.5 - 1.5
15   Furnace Filter     90                    Value range: 0 - 360, step value: 30,
                                              A value of 0 means that the function is
                                               turned off.
16   Recovery           0                     0 - not enabled
                                              1 - enabled
17   Compressor         5                     Value range: 0 - 5 mins
      Protect
18   Heat Temp Range    90℉ / 32℃             °F range: 40 - 90
                                              °C range: 4 - 32


                                         10


19   Cool Temp Range    50℉ / 10℃        °F range: 50 - 99
                                         °C range: 10 - 37
20   Extend Fan On      0                0 - no delay
      Time Heat                          90 - 90 seconds delay
21   Extend Fan On      0                0 - no delay
      Time Cool                          90 - 90 seconds delay
22   Key Lock           Disable          Disable / Enable
23   Temp Calibration   0                °F range: -9 - 9
                                         °C range: -4.5 - 4.5
24   Standby            1 min            30s - no button operation in 30
                                          seconds to enter standby
                                         1min - 1 minute without key operation
                                          to enter standby (default)
                                         2min - no button operation in 2 minutes
                                          to enter standby
                                         5min - 5 minutes without button
                                          operation to enter standby
                                         10min - no button operation in 10
                                          minutes to enter standby
                                         Never - no standby
25   Reset Thermostat   0                Adjust this value to 1 and confirm. All
                                          parameters will then be restored to
                                          the factory settings
26   Factory Test                        Factory test related content


 TIMING Setting

 A TIMING schedule will activate the thermostat at the preset time and

 will keep the room temperature within your preset range.




                                    11


Tap    to add a new timer; tap     to delete a timer; keep the switch in

the ON position      to enable the timer;      means the timer is off.

Tap the schedule to edit it. You may modify the time, days of the week,

and adjust the heat and cool temperature ranges. Note that up to 12

timers can be set.

Key Lock

Password setting:

Each time you enable the key lock you will need to enter a new password.

This password will save until Key Lock is disabled.

When the Standby parameter is set to “Never” and the Key Lock is

enabled, the Key Lock will activate once the thermostat has been idle for

30 seconds.

When the Standby time is set to any other time value and the Key Lock is

enabled, the main interface will lock immediately.

When the system is locked, changing the main interface state, System

Mode or Setting will require you to input the Key Lock password.

Also when the system is locked, the ECO and Away modes will be not be

able to be toggled from the standby screen.


                                  12


Filter Monitoring

To enable this function, you must first modify the number of filter days in

the parameter settings. The thermostat will keep track of the number of

days the filter is used. When the recorded number of days reaches the

preset value, the main display will flash with the filter icon   to prompt

you to replace or clean the filter.

Pre-cooling/preheating

This function works with your TIMING schedules. When the pre-

cooling/preheating function is enabled, the thermostat will calculate how

far in advance it should start so that once the scheduled time arrives, the

desired room temperature range has already been achieved. The

“Recovery” character will be shown on the main display screen when pre-

cooling/preheating has been initiated.

Error Codes

If an issue occurs during your normal operation, an Error code may be

displayed on the main screen to prompt you to repair the equipment.




                                      13


  Displayed Error Code                     Error Code Description
  Er                                       Temperature/Humidity sensor failure
  Lo                                       Low temperature warning
  Hi                                       High temperature warning


FCC Compliance
This device complies with Part 15 of the FCC Rules. Operation is subject to
the following two
conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference
that may cause undesired operation.
Attention that changes or modification not expressly approved by the party
responsible for compliance could void the user’s authority to operate the
equipment.
Note: This product has been tested and found to comply with the limits for a
Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This product generates, uses, and can radiate radio
frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular
installation. If this product does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off
and on, the user is encouraged to try to correct the interference by one or
more of the following measures:
—Reorient or relocate the receiving antenna.
—Increase the separation between the equipment and receiver.
—Connect the equipment into an outlet on a circuit different from that to
which the receiver is
connected.
—Consult the dealer or an experienced radio/TV technician for help

This equipment should be installed and operated with a minimum distance
20cm between the radiator and your body.


                                      14


HaiLin Energy Technology Inc.
Add: Huilongguan International Information Industry Base,
Changping District, Beijing, 102206, P.R.China
Tel: +86 10 52816622
Fax:+86 10 52816633
E-mail: trade@sinohailin.com.cn
http://en.hailin.com/
Version 1.0



Document Created: 2019-08-20 15:14:57
Document Modified: 2019-08-20 15:14:57

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC