RF Exposure Info

FCC ID: 2AJ55HOLYSTONEJX

RF Exposure Info

Download: PDF
FCCID_4036423

                                                           SGS-CSTC Standards Technical Services Co., Ltd.
                                                           Shenzhen Branch

No. 1 Workshop, M-10, Middle section, Science & Technology Park,
Shenzhen, Guangdong, China 518057
Telephone:   +86 (0) 755 2601 2053                                                                                              Report No.: SZEM180700671005
Fax:         +86 (0) 755 2671 0594
                                                                                                                                Page:      1 of 9
Email:       ee.shenzhen@sgs.com

1          Cover page


                   RF Exposure Evaluation Report
Application No.:                                           SZEM1807006710CR
Applicant:                                                 Xiamen Huoshiquan Import & Export CO., LTD
Address of Applicant:       Room 703, No. 813-2 Xiahe Road, Siming District, XIAMEN China
Equipment Under Test (EUT):
Product Name:               RC quadcopter
Model No.:                                                 HS700, HS700D, HS700G, HS710, HS165, HS165G, HS165G, HS120D,
                                                           HS120G, HS130D, HS130G, HS500, HS600, HS800, HS900, HS510, HS610,
                                                           HS810, HS910, HS550, HS650, HS760, HS770, HS880, HS660, HS9001,
                                                           CD200D, CD600, HS500G, HS600G, HS800G, HS900G, HS510G, HS550G,
                                                           HS610G, HS650G, HS660G, HS760G, HS770G, HS880G, HS910G,
                                                           HS500D, HS600D, HS800D, HS900D, HS510D, HS610D, HS810D, HS910D,
                                                           HS650D, HS660D, HS760D, HS770D, HS880D, HS410, HS510, HS175,
                                                           HS176, HS320, HS330 ♣
♣                                                          Please refer to section 4.1 of this report which indicates which model was
                                                           actually tested and which were electrically identical.
FCC ID:                                                    2AJ55HOLYSTONEJX
Standards:                                                 47 CFR Part 1.1307 (2016)
                                                           47 CFR Part 1.1310 (2016)
Date of Receipt:                                           2018-07-26
Date of Test:                                              2018-07-26 to 2018-09-04
Date of Issue:                                             2018-09-12
Test Result :                                                 PASS*

*        In the configuration tested, the EUT complied with the standards specified above.




                   Keny Xu
             EMC Laboratory Manager
The manufacturer should ensure that all products in series production are in conformity with the product sample detailed in this report.
If the product in this report is used in any configuration other than that detailed in the report, the manufacturer must ensure the new
system complies with all relevant standards. Any mention of SGS International Electrical Approvals or testing done by SGS
International Electrical Approvals in connection with, distribution or use of the product described in this report must be approved by SGS
International Electrical Approvals in writing.
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com/en/Terms-and-Conditions.aspx and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com/en/Terms-and-Conditions/Terms-e-Document.aspx. Attention is drawn to the limitation of
liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention
only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights
and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification
of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the
sample(s) tested and such sample(s) are retained for 30 days only.


                                                           SGS-CSTC Standards Technical Services Co., Ltd
                                                           Shenzhen Branch.
                                                                                                                                  Report No.: SZEM180700671005
                                                                                                                                  Page:       2 of 9

2 Version

                                                                                       Revision Record
                 Version                     Chapter                             Date                                         Modifier                           Remark

                 01                                                              2018-09-12                                                                      Original




         Authorized for issue by:




                                                                      Bill Chen /Project Engineer




                                                                      Eric Fu /Reviewer




This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com/en/Terms-and-Conditions.aspx and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com/en/Terms-and-Conditions/Terms-e-Document.aspx. Attention is drawn to the limitation of
liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention
only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and
obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the
content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s)
tested and such sample(s) are retained for 30 days only.


                                                           SGS-CSTC Standards Technical Services Co., Ltd
                                                           Shenzhen Branch.
                                                                                                                                  Report No.: SZEM180700671005
                                                                                                                                  Page:       3 of 9

3           Contents
                                                                                                                                                                                                   Page
1         COVER PAGE .............................................................................................................................................. 1

2         VERSION ...................................................................................................................................................... 2

3         CONTENTS .................................................................................................................................................. 3

4         GENERAL INFORMATION .......................................................................................................................... 4
     4.1       GENERAL DESCRIPTION OF EUT ................................................................................................................. 4
     4.2       TEST LOCATION .......................................................................................................................................... 6
     4.3       TEST FACILITY ............................................................................................................................................ 6
     4.4       DEVIATION FROM STANDARDS ..................................................................................................................... 7
     4.5       ABNORMALITIES FROM STANDARD CONDITIONS............................................................................................ 7
     4.6       OTHER INFORMATION REQUESTED BY THE CUSTOMER ................................................................................. 7
5         RF EXPOSURE EVALUATION .................................................................................................................... 8
     5.1 RF EXPOSURE COMPLIANCE REQUIREMENT ................................................................................................ 8
        5.1.1 Limits ................................................................................................................................................ 8
        5.1.2 Test Procedure ................................................................................................................................ 8
     4.1.3 EUT RF EXPOSURE EVALUATION ............................................................................................................... 9




This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com/en/Terms-and-Conditions.aspx and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com/en/Terms-and-Conditions/Terms-e-Document.aspx. Attention is drawn to the limitation of
liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention
only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and
obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the
content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s)
tested and such sample(s) are retained for 30 days only.


                                                           SGS-CSTC Standards Technical Services Co., Ltd
                                                           Shenzhen Branch.
                                                                                                                                  Report No.: SZEM180700671005
                                                                                                                                  Page:       4 of 9

4            General Information

4.1 General Description of EUT
             Power supply:                                  DC 7.4V

           Frequency Range:                                    UNII Band                  IEEE 802.11a                                              5745-5825                        5
                                                               III

                                                                                          IEEE 802.11n 20MHz                                        5745-5825                        5

           Data Modulation:                                 For 802.11a: OFDM(BPSK/QPSK/16QAM/64QAM)
                                                            For 802.11n: OFDM(8PSK/QPSK/16QAM/64QAM)
           Antenna Type:                                    Monopole
           Antenna Gain:                                    Antenna 1:2dBi Antenna 2:2dBi

                                                            Two antennas can not simultaneous transmission.


             Power supply:                                 RX: Rechargeable battery 7.4V 2800mAh(Charge by USB)
             Operation Frequency                           2417MHz to 2466MHz
             Modulation Type:                              GFSK
             Number of Channels:                           50
             Channel Spacing:                              1MHz
             Antenna Type:                                 Monopole
             Antenna Gain:                                 Antenna 1:2dBi Antenna 2:2dBi

                                                           Two antennas can not simultaneous transmission.
Remark:
The 5GHz camera needs to be used with the drone, 5GHz camera and drone can simultaneous transmission,
drone has an FCC ID: 2AJ55HOLYSTONEMJ.




This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com/en/Terms-and-Conditions.aspx and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com/en/Terms-and-Conditions/Terms-e-Document.aspx. Attention is drawn to the limitation of
liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention
only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and
obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the
content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s)
tested and such sample(s) are retained for 30 days only.


                                                           SGS-CSTC Standards Technical Services Co., Ltd
                                                           Shenzhen Branch.
                                                                                                                                  Report No.: SZEM180700671005
                                                                                                                                  Page:       5 of 9


              Declaration of EUT Family Grouping:

              Model No.: HS700, HS700D, HS700G, HS710, HS165, HS165G, HS165G, HS120D, HS120G, HS130D,
              HS130G, HS500, HS600, HS800, HS900, HS510, HS610, HS810, HS910, HS550, HS650, HS760,
              HS770, HS880, HS660, HS9001, CD200D, CD600, HS500G, HS600G, HS800G, HS900G, HS510G,
              HS550G, HS610G, HS650G, HS660G, HS760G, HS770G, HS880G, HS910G, HS500D, HS600D,
              HS800D, HS900D, HS510D, HS610D, HS810D, HS910D, HS650D, HS660D, HS760D, HS770D,
              HS880D, HS410, HS510, HS175, HS176, HS320, HS330

              Only the model HS700 was tested, since the electrical circuit design, layout, components used, internal
              wiring and functions were identical for the above models, with only the colour, appearance, package and
              assort is different.




This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com/en/Terms-and-Conditions.aspx and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com/en/Terms-and-Conditions/Terms-e-Document.aspx. Attention is drawn to the limitation of
liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention
only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and
obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the
content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s)
tested and such sample(s) are retained for 30 days only.


                                                           SGS-CSTC Standards Technical Services Co., Ltd
                                                           Shenzhen Branch.
                                                                                                                                  Report No.: SZEM180700671005
                                                                                                                                  Page:       6 of 9



4.2 Test Location
           All tests were performed at:
           SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch
           No. 1 Workshop, M-10, Middle section, Science & Technology Park, Shenzhen, Guangdong, China
           518057
           Telephone: +86 (0) 755 2601 2053                                      Fax: +86 (0) 755 2671 0594
           No tests were sub-contracted.

4.3 Test Facility
            The test facility is recognized, certified, or accredited by the following organizations:
            • CNAS (No. CNAS L2929)
            CNAS has accredited SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch EMC
            Lab to ISO/IEC 17025:2005 General Requirements for the Competence of Testing and Calibration
            Laboratories (CNAS-CL01 Accreditation Criteria for the Competence of Testing and Calibration
            Laboratories) for the competence in the field of testing.
            • A2LA (Certificate No. 3816.01)
            SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen EMC Laboratory is accredited by the
            American Association for Laboratory Accreditation(A2LA). Certificate No. 3816.01.
            • VCCI
            The 3m Fully-anechoic chamber for above 1GHz, 10m Semi-anechoic chamber for below 1GHz,
            Shielded Room for Mains Port Conducted Interference Measurement and Telecommunication Port
            Conducted Interference Measurement of SGS-CSTC Standards Technical Services Co., Ltd. have
            been registered in accordance with the Regulations for Voluntary Control Measures with Registration
            No.: G-20026, R-14188, C-12383 and T-11153 respectively.
            • FCC –Designation Number: CN1178
            SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen EMC Laboratory has been recognized
            as an accredited testing laboratory.
            Designation Number: CN1178. Test Firm Registration Number: 406779.
            • Industry Canada (IC)
            Two 3m Semi-anechoic chambers and the 10m Semi-anechoic chamber of SGS-CSTC Standards
            Technical Services Co., Ltd. Shenzhen Branch EMC Lab have been registered by Certification and
            Engineering Bureau of Industry Canada for radio equipment testing with Registration No.: 4620C-1,
            4620C-2, 4620C-3.




This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com/en/Terms-and-Conditions.aspx and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com/en/Terms-and-Conditions/Terms-e-Document.aspx. Attention is drawn to the limitation of
liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention
only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and
obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the
content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s)
tested and such sample(s) are retained for 30 days only.


                                                           SGS-CSTC Standards Technical Services Co., Ltd
                                                           Shenzhen Branch.
                                                                                                                                  Report No.: SZEM180700671005
                                                                                                                                  Page:       7 of 9

4.4 Deviation from Standards
            None.

4.5 Abnormalities from Standard Conditions
           None.

4.6 Other Information Requested by the Customer
            None.




This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com/en/Terms-and-Conditions.aspx and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com/en/Terms-and-Conditions/Terms-e-Document.aspx. Attention is drawn to the limitation of
liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention
only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and
obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the
content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s)
tested and such sample(s) are retained for 30 days only.


                                                           SGS-CSTC Standards Technical Services Co., Ltd
                                                           Shenzhen Branch.
                                                                                                                                  Report No.: SZEM180700671005
                                                                                                                                  Page:       8 of 9

5              RF Exposure Evaluation

5.1           RF Exposure Compliance Requirement
5.1.1 Limits
               According to FCC Part1.1310: The criteria listed in the following table shall be used to evaluate the
               environment impact of human exposure to radio frequency (RF) radiation as specified in part1.1307(b)




F= Frequency in MHz
Friis Formula
Friis transmission formula: Pd = (Pout*G)/(4* Pi * R 2)
Where
Pd = power density in mW/cm2
Pout = output power to antenna in mW
G = gain of antenna in linear scale
Pi = 3.1416

R = distance between observation point and center of the radiator in cm
Pd id the limit of MPE, 1 mW/cm2 . If we know the maximum gain of the antenna and the total power input to
the antenna, through the calculation, we will know the distance r where the MPE limit is reached.

5.1.2 Test Procedure
               Software provided by client enabled the EUT to transmit and receive data at lowest, middle and
               highest channel individually.




This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com/en/Terms-and-Conditions.aspx and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com/en/Terms-and-Conditions/Terms-e-Document.aspx. Attention is drawn to the limitation of
liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention
only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and
obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the
content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s)
tested and such sample(s) are retained for 30 days only.


                                                           SGS-CSTC Standards Technical Services Co., Ltd
                                                           Shenzhen Branch.
                                                                                                                                  Report No.: SZEM180700671005
                                                                                                                                  Page:       9 of 9

4.1.3 EUT RF Exposure Evaluation
For 2.4GHz
Antenna 1 Gain: 2dBi
Antenna 2 Gain: 2dBi
Antenna Gain: The maximum Gain measured in fully anechoic chamber is 1.59 in linear scale.
Output Power Into Antenna & RF Exposure Evaluation Distance:
   Channel                Frequency                   Max Conducted                          Output Power                          Power Density                         Limit            Result
                               (MHz)                     Peak Output                            to Antenna                           at R = 20 cm
                                                        Power (dBm)                                   (mW)                              (mW/cm2)
    Lowest                      2417                             -10.4                                 0.09                               0.00003                          1.0             PASS
Note: Refer to report No. SZEM180700671002 for EUT test Max Conducted Peak Output Power value.
The distance r (4th column) calculated from the Fries transmission formula is far greater than 20 cm separation
requirement.


For 5GHz
Antenna 1 Gain: 2dBi
Antenna 2 Gain: 2dBi
Antenna Gain: The maximum Gain measured in fully anechoic chamber is 1.59 in linear scale.
Output Power Into Antenna & RF Exposure Evaluation Distance:


   Channel                Frequency                   Max Conducted                          Output Power                          Power Density                         Limit            Result
                               (MHz)                     Peak Output                            to Antenna                           at R = 20 cm
                                                        Power (dBm)                                   (mW)                              (mW/cm2)
    Lowest                      5745                             12.75                                18.84                                 0.006                          1.0             PASS


Note: Refer to report No. SZEM180700671004 for EUT test Max Conducted Peak Output Power value.
The distance r (4th column) calculated from the Fries transmission formula is far greater than 20 cm separation
requirement.

So, Simultaneous transmission SAR test is not required, because the Max. sum of the MPE ratios is
     0.00003+0.006=0.00603<1.


                                                                                   - End of the Report -




This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com/en/Terms-and-Conditions.aspx and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com/en/Terms-and-Conditions/Terms-e-Document.aspx. Attention is drawn to the limitation of
liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention
only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and
obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the
content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s)
tested and such sample(s) are retained for 30 days only.



Document Created: 2018-10-13 01:35:40
Document Modified: 2018-10-13 01:35:40

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC