RF Exposure Info

FCC ID: 2AJ55HOLYSTONEDE

RF Exposure Info

Download: PDF
FCCID_4221897

                                   SGS-CSTC Standards Technical Services Co., Ltd.
                                   Shenzhen Branch




                                                                         Report No.: SZEM181200116303
                                                                         Page:        1 of 8
1    Cover page


          RF Exposure Evaluation Report
Application No.:                 SZEM1812001163CR
Applicant:                       Xiamen Huoshiquan Import & Export CO., LTD
Address of Applicant:            Room 703, No. 813-2 Xiahe Road, Siming District, XIAMEN, China

Equipment Under Test (EUT):
Product Name:               RC Quadcopter
Model No.:                       HS270, HS370, HS720, HS181, HS700D, HS110G, HS200G, HS161,
                                 HS161G, HS161D, HS161R, HS161PRO, HS161S, HS165, HS165D,
                                 HS165G, HS350, HS350D, HS350G, HS310, DE21, DE21G, DE22, DE22G,
                                 DE23, DE23G, DE24, DE24G, DE25, DE25G, DE26, DE26G, DE27, DE27G,
                                 DE28, DE28G, DE29, DE29G, DE31, DE32, DE33, DE34, DE35, DE35W,
                                 DE36, DE36W, DE37, DE37W, DE38, DE39, DE41, DE42, DE43, DE44,
                                 DE45, DE46, DE47, DE48, DE49, DE51, DE52, DE53, DE54, DE55, DE56,
                                 DE57, DE58, DE59, DE61, DE62, DE63, DE64, DE65, DE65W, DE66, DE67,
                                 DE68, DE68W, DE69 ♣
♣                                Please refer to section 4 of this report which indicates which model was
                                 actually tested and which were electrically identical.
FCC ID:                          2AJ55HOLYSTONEDE
Standards:                       47 CFR Part 1.1307
                                 47 CFR Part 1.1310
Date of Receipt:                 2018-12-29
Date of Test:                    2019-01-08 to 2019-02-25
Date of Issue:                   2019-03-08
Test Result :                    PASS*

*   In the configuration tested, the EUT complied with the standards specified above.




            Keny Xu
      EMC Laboratory Manager


                             SGS-CSTC Standards Technical Services Co., Ltd.
                             Shenzhen Branch
                                                              Report No.: SZEM181200116303
                                                              Page:       2 of 8

2 Version

                                        Revision Record
      Version        Chapter         Date                     Modifier     Remark

      01                             2019-03-08                            Original




  Authorized for issue by:




                                Bill Chen /Project Engineer




                                Eric Fu /Reviewer


                                                SGS-CSTC Standards Technical Services Co., Ltd.
                                                Shenzhen Branch
                                                                                                      Report No.: SZEM181200116303
                                                                                                      Page:       3 of 8

3         Contents
                                                                                                                                                            Page
1       COVER PAGE .............................................................................................................................................. 1

2       VERSION ...................................................................................................................................................... 2

3       CONTENTS .................................................................................................................................................. 3

4       GENERAL INFORMATION .......................................................................................................................... 4
    4.1     GENERAL DESCRIPTION OF EUT ................................................................................................................. 4
    4.2     TEST LOCATION .......................................................................................................................................... 5
    4.3     TEST FACILITY ............................................................................................................................................ 5
    4.4     DEVIATION FROM STANDARDS ..................................................................................................................... 6
    4.5     ABNORMALITIES FROM STANDARD CONDITIONS............................................................................................ 6
    4.6     OTHER INFORMATION REQUESTED BY THE CUSTOMER ................................................................................. 6
5       RF EXPOSURE EVALUATION .................................................................................................................... 7
    5.1 RF EXPOSURE COMPLIANCE REQUIREMENT ................................................................................................ 7
       5.1.1 Limits ................................................................................................................................................ 7
       5.1.2 Test Procedure ................................................................................................................................ 7
    4.1.3 EUT RF EXPOSURE EVALUATION ............................................................................................................... 8


                            SGS-CSTC Standards Technical Services Co., Ltd.
                            Shenzhen Branch
                                                               Report No.: SZEM181200116303
                                                               Page:       4 of 8


4   General Information

4.1 General Description of EUT
    Power supply:               Plane:Rechargeable battery DC 3.7V 1000mAh 3.7Wh(Charge by USB)
    Modulation Type:            802.11b: DSSS (CCK, DQPSK, DBPSK)
                                802.11g/n: OFDM (64QAM, 16QAM, QPSK, BPSK)
    Number of Channels:         802.11b/g/n(HT20):11
    Operation Frequency:        802.11b/g/n(HT20): 2412MHz to 2462MHz

    Sample Type:                Mobile production

    Channel Spacing:            5MHz
    Antenna Gain:               2dBi
    Antenna Type:               Integral


    Declaration of EUT Family Grouping:

    Model No.: HS270, HS370, HS720, HS181, HS700D, HS110G, HS200G, HS161, HS161G, HS161D,
    HS161R, HS161PRO, HS161S, HS165, HS165D, HS165G, HS350, HS350D, HS350G, HS310,
    DE21, DE21G, DE22, DE22G, DE23, DE23G, DE24, DE24G, DE25, DE25G, DE26, DE26G, DE27,
    DE27G, DE28, DE28G, DE29, DE29G, DE31, DE32, DE33, DE34, DE35, DE35W, DE36, DE36W,
    DE37, DE37W, DE38, DE39, DE41, DE42, DE43, DE44, DE45, DE46, DE47, DE48, DE49, DE51,
    DE52, DE53, DE54, DE55, DE56, DE57, DE58, DE59, DE61, DE62, DE63, DE64, DE65, DE65W,
    DE66, DE67, DE68, DE68W, DE69

    Only the model HS161 was tested, since the electrical circuit design, layout, components used,
    internal wiring and functions were identical for the above models, with only difference on colour,
    appearance and packaging.


                              SGS-CSTC Standards Technical Services Co., Ltd.
                              Shenzhen Branch
                                                                Report No.: SZEM181200116303
                                                                Page:       5 of 8




4.2 Test Location
    All tests were performed at:
    SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch
    No. 1 Workshop, M-10, Middle section, Science & Technology Park, Shenzhen, Guangdong, China
    518057
    Telephone: +86 (0) 755 2601 2053    Fax: +86 (0) 755 2671 0594
    No tests were sub-contracted.

4.3 Test Facility
    The test facility is recognized, certified, or accredited by the following organizations:
    • CNAS (No. CNAS L2929)
    CNAS has accredited SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch EMC
    Lab to ISO/IEC 17025:2005 General Requirements for the Competence of Testing and Calibration
    Laboratories (CNAS-CL01 Accreditation Criteria for the Competence of Testing and Calibration
    Laboratories) for the competence in the field of testing.
    • A2LA (Certificate No. 3816.01)
    SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen EMC Laboratory is accredited by the
    American Association for Laboratory Accreditation(A2LA). Certificate No. 3816.01.
    • VCCI
    The 3m Fully-anechoic chamber for above 1GHz, 10m Semi-anechoic chamber for below 1GHz,
    Shielded Room for Mains Port Conducted Interference Measurement and Telecommunication Port
    Conducted Interference Measurement of SGS-CSTC Standards Technical Services Co., Ltd. have been
    registered in accordance with the Regulations for Voluntary Control Measures with Registration No.: G-
    20026, R-14188, C-12383 and T-11153 respectively.
    • FCC –Designation Number: CN1178
    SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen EMC Laboratory has been recognized
    as an accredited testing laboratory.
    Designation Number: CN1178. Test Firm Registration Number: 406779.
    • Innovation, Science and Economic Development Canada
    SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen EMC Laboratory has been recognized
    by ISED as an accredited testing laboratory.
    CAB identifier: CN0006.
    IC#: 4620C.


                   SGS-CSTC Standards Technical Services Co., Ltd.
                   Shenzhen Branch
                                             Report No.: SZEM181200116303
                                             Page:       6 of 8


4.4 Deviation from Standards
   None.

4.5 Abnormalities from Standard Conditions
   None.

4.6 Other Information Requested by the Customer
   None.


                                 SGS-CSTC Standards Technical Services Co., Ltd.
                                 Shenzhen Branch
                                                                     Report No.: SZEM181200116303
                                                                     Page:       7 of 8


5       RF Exposure Evaluation

5.1     RF Exposure Compliance Requirement
5.1.1 Limits
        According to FCC Part1.1310: The criteria listed in the following table shall be used to evaluate the
        environment impact of human exposure to radio frequency (RF) radiation as specified in part1.1307(b)




F= Frequency in MHz
Friis Formula
Friis transmission formula: Pd = (Pout*G)/(4* Pi * R 2)
Where
Pd = power density in mW/cm2
Pout = output power to antenna in mW
G = gain of antenna in linear scale
Pi = 3.1416

R = distance between observation point and center of the radiator in cm
Pd id the limit of MPE, 1 mW/cm2 . If we know the maximum gain of the antenna and the total power input to
the antenna, through the calculation, we will know the distance r where the MPE limit is reached.

5.1.2 Test Procedure
        Software provided by client enabled the EUT to transmit and receive data at lowest, middle and
        highest channel individually.


                               SGS-CSTC Standards Technical Services Co., Ltd.
                               Shenzhen Branch
                                                                    Report No.: SZEM181200116303
                                                                    Page:       8 of 8


4.1.3 EUT RF Exposure Evaluation

Antenna Gain: 2dBi
Antenna Gain: The maximum Gain measured in fully anechoic chamber is 1.58 in linear scale.
Output Power Into Antenna & RF Exposure Evaluation Distance:


 Channel       Frequency    Max Conducted        Output Power        Power Density       Limit    Result
                 (MHz)        Peak Output          to Antenna         at R = 20 cm
                             Power (dBm)              (mW)             (mW/cm2)
  Lowest         2412             21.37              137.09               0.043           1.0      PASS


Note: Refer to report No. SZEM181200116302 for EUT test Max Conducted Peak Output Power value.
The distance r (4th column) calculated from the Fries transmission formula is far greater than 20 cm separation
requirement.



                                            - End of the Report -