14_TPS360 TestRpt DXX, r1

FCC ID: 2AJ2B-TPS360

Test Report

Download: PDF
FCCID_3924376

                                                                                       Page 1 of 26




                     FCC Test Report

                          Report No.: AGC01684180501FE06




 FCC ID                         : 2AJ2B-TPS360

 APPLICATION PURPOSE            : Original Equipment

 PRODUCT DESIGNATION            : Handheld Fingerprint Terminal

 BRAND NAME                     : N/A

 MODEL NAME                     : TPS360

 CLIENT                         : Telepower Communication Co., Ltd

 DATE OF ISSUE                  : July 12, 2018
 STANDARD(S)
                                : FCC Part 15 Rules
 TEST PROCEDURE(S)
                                :
 REPORT VERSION                     V1.1




       Attestation of Global Compliance (Shenzhen) Co., Ltd

CAUTION:
This report shall not be reproduced except in full without the written permission of the test
laboratory and shall not be quoted out of context.


                                                               Report No.: AGC01684180501FE06
                                                                                   Page 2 of 26


                                   REPORT REVISE RECORD

Report Version   Revise Time   Issued Date     Valid Version              Notes

    V1.0              /        June 25, 2018      Invalid            Original Report

    V1.1             1st       July 12, 2018       Valid            Revise Report P5


                                                                                                               Report No.: AGC01684180501FE06
                                                                                                                                   Page 3 of 26


                                                               TABLE OF CONTENTS

1. VERIFICATION OF CONFORMITY.................................................................................................................. 4
2. GENERAL INFORMATION .............................................................................................................................. 5
3. MEASUREMENT UNCERTAINTY ................................................................................................................... 6
4. DESCRIPTION OF TEST MODES ................................................................................................................... 7
5. SYSTEM TEST CONFIGURATION .................................................................................................................. 8
   5.1. CONFIGURATION OF EUT SYSTEM........................................................................................................ 8
   5.2. EQUIPMENT USED IN EUT SYSTEM ....................................................................................................... 8
   5.3. SUMMARY OF TEST RESULTS ................................................................................................................ 8
6. TEST FACILITY ................................................................................................................................................ 9
7. RADIATED EMISSION ................................................................................................................................... 10
   7.1TEST LIMIT ................................................................................................................................................ 10
   7.2. MEASUREMENT PROCEDURE ............................................................................................................. 11
   7.3. TEST SETUP............................................................................................................................................ 13
   7.4. TEST RESULT.......................................................................................................................................... 14
8. FREQUENCY STABILITY .............................................................................................................................. 17
   8.1. MEASUREMENT PROCEDURE ............................................................................................................. 17
   8.2. TEST SET-UP (BLOCK DIAGRAM OF CONFIGURATION) .................................................................... 17
   8.3. MEASUREMENT RESULTS .................................................................................................................... 18
9. 20DB BANDWIDTH ........................................................................................................................................ 19
   9.1. MEASUREMENT PROCEDURE ............................................................................................................. 19
   9.2. TEST SET-UP (BLOCK DIAGRAM OF CONFIGURATION) .................................................................... 19
  9.3. MEASUREMENT RESULTS .................................................................................................................... 20
10. FCC LINE CONDUCTED EMISSION TEST ................................................................................................ 21
   10.1. LIMITS OF LINE CONDUCTED EMISSION TEST ................................................................................ 21
   10.2. BLOCK DIAGRAM OF LINE CONDUCTED EMISSION TEST .............................................................. 21
   10.3. PRELIMINARY PROCEDURE OF LINE CONDUCTED EMISSION TEST ........................................... 22
   10.4. FINAL PROCEDURE OF LINE CONDUCTED EMISSION TEST .......................................................... 22
  10.5. TEST RESULT OF LINE CONDUCTED EMISSION TEST .................................................................... 23
APPENDIX A: PHOTOGRAPHS OF TEST SETUP .......................................................................................... 25


                                                                         Report No.: AGC01684180501FE06
                                                                                             Page 4 of 26


1. VERIFICATION OF CONFORMITY
Applicant                  Telepower Communication Co., Ltd
                           5 Bld, Zone A, Hantian Technology Town,No.17 ShenHai RD, Nanhai District
Address
                           Foshan, China
Manufacturer               Telepower Communication Co., Ltd
                           5 Bld, Zone A, Hantian Technology Town,No.17 ShenHai RD, Nanhai District
Address
                           Foshan, China
Product Designation        Handheld Fingerprint Terminal
Brand Name                 N/A
Test Model                 TPS360
Date of test               May. 28, 2018~June 25, 2018
Deviation                  None
Condition of Test Sample Normal
Report Template            AGCRT-US-BR/RF
We hereby certify that:
The above equipment was tested by Attestation of Global Compliance (Shenzhen) Co., Ltd. The test data,
data evaluation, test procedures, and equipment configurations shown in this report were made in accordance
with the procedures given in ANSI C63.10 (2013) and the energy emitted by the sample EUT tested as
described in this report is in compliance with radiated emission limits of FCC Rules Part 15.225.



                     Tested By

                                          Donjon Huang(Huang
                                                                        June 25, 2018
                                               Dongyang)

                   Reviewed By


                                          Bart Xie(Xie Xiaobin)          July 12, 2018

                   Approved By

                                        Forrest Lei(Lei Yonggang)
                                                                         July 12, 2018
                                            Authorized Officer


                                                                         Report No.: AGC01684180501FE06
                                                                                             Page 5 of 26


2. GENERAL INFORMATION
A major technical description of EUT is described as following
Operation Frequency                          13.561MHz
Maximum field strength                       45.75dBμV/m@3m
Modulation                                   ASK
Number of channels                           1
Antenna Gain                                 0dBi
Antenna Designation                          Internal Antenna (Met 15.203 Antenna requirement)
Hardware Version                             MAIN-360D-V2.4
Software Version                             TPS360_V1.0.0
Power Supply                                 DC 3.8V by adapter


                                                                          Report No.: AGC01684180501FE06
                                                                                              Page 6 of 26


3. MEASUREMENT UNCERTAINTY
The uncertainty is calculated using the methods suggested in the “Guide to the Expression of Uncertainty in
measurement” (GUM) published by CISPR and ANSI.
- Uncertainty of Conducted Emission, Uc = ±3.2 dB
- Uncertainty of Radiated Emission below 1GHz, Uc = ±3.9 dB
- Uncertainty of Radiated Emission above 1GHz, Uc = ±4.8 dB


                                                                          Report No.: AGC01684180501FE06
                                                                                              Page 7 of 26


4. DESCRIPTION OF TEST MODES
  NO.                                     TEST MODE DESCRIPTION
   1                                               Transmitting
  Note:
  1. All the test modes can be supply by adapter, only the result of the worst case was recorded in the
  report, if no other cases.
  2. For Radiated Emission, 3axis were chosen for testing for each applicable mode.


                                                                 Report No.: AGC01684180501FE06
                                                                                     Page 8 of 26


5. SYSTEM TEST CONFIGURATION
5.1. CONFIGURATION OF EUT SYSTEM
   Configure:



                EUT                Accessory



5.2. EQUIPMENT USED IN EUT SYSTEM
 Item           Equipment            Model No.            ID or Specification         Remark
           Handheld Fingerprint
  1                                    TPS360               2AJ2B-TPS360                EUT
                Terminal
  2               Adapter         SC/10WA050200US            DC 5.0V 2A              Accessory
  3               Battery             HDT-7100            DC3.8V/ 3000mAh            Accessory
  4                   USB               N/A                      N/A                 Accessory


5.3. SUMMARY OF TEST RESULTS

  FCC RULES                       DESCRIPTION OF TEST                            RESULT
      §15.209                        Radiated Emission                           Compliant
      §15.207                       Conducted Emission                           Compliant
      §15.225                       Frequency Tolerance                          Compliant
      §15.225                         20dB bandwidth                             Compliant


                                                                       Report No.: AGC01684180501FE06
                                                                                           Page 9 of 26


6. TEST FACILITY
     Test Site         Attestation of Global Compliance (Shenzhen) Co., Ltd
                       1-2F., Bldg.2, No.1-4, Chaxi Sanwei Technical Industrial Park, Gushu, Xixiang,
     Location          Bao’an District B112-B113, Bldg.12, Baoan Bldg Materials Center, No.1 of Xixiang
                       Inner Ring Road, Baoan District, Shenzhen 518012
 NVLAP LAB CODE        600153-0
Designation Number     CN5028
                       Attestation of Global Compliance(Shenzhen) Co., Ltd is accredited by National
    Description
                       Voluntary Laboratory Accreditation program, NVLAP Code 600153-0

TEST EQUIPMENT OF RADIATED EMISSION TEST
  Equipment          Manufacturer           Model              S/N            Cal. Date       Cal. Due
TEST RECEIVER            R&S                 ESCI             10096        Jun.20, 2017     Jun.19, 2018
TEST RECEIVER            R&S                 ESCI             10096        Jun.18, 2018     Jun.17, 2019
  EXA Signal
                        Aglient            N9010A         MY53470504      Dec.08, 2017     Dec.07, 2018
   Analyzer
  Horn antenna     SCHWARZBECK            BBHA 9170           #768        Sep.20, 2017     Sep.19, 2018
  preamplifier          ChengYi         EMC184045SE          980508       Sep.15, 2017     Sep.14, 2018
  Active loop
   antenna               A.H.             SAS-562B             N/A        Feb.27, 2018      Feb.26, 2019
 (9K-30MHz)
Double-Ridged
                     ETS LINDGREN            3117           00034609      May.18, 2017     May.17, 2019
Waveguide Horn
  Broadband
                   SCHWARZBECK            BBV 9718          9718-205       Jun.20, 2017     Jun.19, 2018
 Preamplifier
  Broadband
                   SCHWARZBECK            BBV 9718          9718-205       Jun.18, 2018     Jun.17, 2019
 Preamplifier
   ANTENNA         SCHWARZBECK            VULB9168           D69250       Sep.28, 2017     Sep.27, 2018


TEST EQUIPMENT OF CONDUCTED EMISSION TEST
    Equipment          Manufacturer         Model             S/N             Cal. Date       Cal. Due
 TEST RECEIVER             R&S              ESPI            101206        Jun.20, 2017      Jun.19, 2018
 TEST RECEIVER             R&S              ESPI            101206        Jun.18, 2018      Jun.17, 2019
      LISN                 R&S            ESH2-Z5           100086        Aug.21, 2017     Aug.20, 2018


                            ®
                                3       mitues
                                        TF      MA t ol
                                Attestation of Global Compliance
                                                                                                                         Report No.: AGC01684180501FEO6
                                                                                                                                                             Page 10 of 26


    7. RADIATED EMISSION
    7.A1TEST LIMIT
    Standard FCC15.225 for within the 13.110MHz—14.010MHz band
                Frequencies                   Field Strength at 3O0m                      Field Strength at 30m                         Field Strength at 3m
                   (MHz)                          (micorvolts/meter)                                 (dBuV/m)                                     (dBuV/m)
             13.553~13.567                                15.848                                           84                                          124
             13.410~13.553
             13.567~13.710                                  g*                                           PA                                            90.5
             13.110~13.410
             13.710~14.010                                   106                                         40.5                                          $o.5
    According to 15.35, on any frequency or frequencies below or equal to 1000 MHz, the limits Shown are based
    on measuring equipment employing a CISPR quasi—peak detector function and related measurement
    bandwidths, unless otherwise specified the limit on peak radio frequency emissions is 20dB above the
    maximum permitted average emission limit applicable to the equipment under test.

    Standard FCC 15.209 for outside of the 13.110MH2z—14.010MHz band

    Frequency                                Distance                                                                Field Strengths Limit
    (MHz)                                    Meters                                       u V/m                                          dB(pV)/m
    0.009 ~ 0.490                            300                                          2400/F (KkHz)
    0.490 ~ 1.705                            30                                           24000/F(kHz)
    1.705 ~ 30                               30                                           30
    30 ~ 88                                  3                                            100                                            40.0
    88 ~ 216                                 3                                            150                                            43.5
    216 ~ 960                                3                                            200                                            46.0
    960 ~ 1000                               3                                            500                                            54.0
    Above        1000                        3                                            Other:74.0 dB(uV)/m (Peak) 54.0 dB(uV)/m (Average)
    Remark:           (1) Emission level dBu V = 20 log Emission level u V/m
                      (2) The smaller limit shall apply at the cross point between two frequency bands.
                      (3) Distance is the distance in meters between the measuring instrument, antenna and the closest
                           point of any part of the device or system.




The results ’m,6tison|
                  o thisfeaes report refer only to the sample(s) tested unless otherwise stated and the sample(s) are retained for 30 days only. The document
is issued by/A 6§€ this doc(fia it cannot be reproduced except in full with our prior written permission. The more details and the authenticity of the report will be
confirmed t;!?ttp://www.agc-«drS t.com.
            o

                                                      Tel: +86—755 2908 1955            Fax: +86—755 2600 8484             E—mail: agc@age—cert.com             @ 400 089 2118
                                                      Add: 2/F. , Building 2, No.1—4, Chaxi Sanwei Technical Industrial Park,Gushu, Xixiang, Bacan District, Shenzhen, Guangdong China


                                                                           Report No.: AGC01684180501FE06
                                                                                              Page 11 of 26


7.2. MEASUREMENT PROCEDURE
 1. The EUT was placed on the top of the turntable 0.8 meter above ground. The phase center of the
    receiving antenna mounted on the top of a height-variable antenna tower was placed 3 meters far away
    from the turntable.
 2. Power on the EUT and all the supporting units. The turntable was rotated by 360 degrees to determine
    the position of the highest radiation.
 3. The height of the broadband receiving antenna was varied between one meter and four meters above
    ground to find the maximum emissions field strength of both horizontal and vertical polarization.
 4. For each suspected emissions, the antenna tower was scan (from 1 M to 4 M) and then the turntable was
    rotated (from 0 degree to 360 degrees) to find the maximum reading.
 5. Set the test-receiver system to Peak or CISPR quasi-peak Detect Function with specified bandwidth
    under Maximum Hold Mode.
 6. For emissions above 1GHz, use 1MHz VBW and RBW for peak reading. Then 1MHz RBW and 10Hz
    VBW for average reading in spectrum analyzer.
 7. When the radiated emissions limits are expressed in terms of the average value of the emissions, and
    pulsed operation is employed, the measurement field strength shall be determined by averaging over one
    complete pulse train, including blanking intervals, as long as the pulse train does not exceed 0.1 seconds.
    As an alternative (provided the transmitter operates for longer than 0.1 seconds) or in cases where the
    pulse train exceeds 0.1 seconds, the measured field strength shall be determined from the average
    absolute voltage during a 0.1 second interval during which the field strength is at its maximum values.
 8.If the emissions level of the EUT in peak mode was 3 dB lower than the average limit specified, then
    testing will be stopped and peak values of EUT will be reported, otherwise, the emissions which do not
    have 3 dB margin will be repeated one by one using the quasi-peak method for below 1GHz.
 9. For testing above 1GHz, the emissions level of the EUT in peak mode was lower than average limit (that
    means the emissions level in peak mode also complies with the limit in average mode), then testing will
    be stopped and peak values of EUT will be reported, otherwise, the emissions will be measured in
    average mode again and reported.
 10. In case the emission is lower than 30MHz, loop antenna has to be used for measurement and the
 recorded data should be QP measured by receiver. High - Low scan is not required in this case.


                                                                         Report No.: AGC01684180501FE06
                                                                                            Page 12 of 26


The following table is the setting of spectrum analyzer and receiver.
               Spectrum Parameter                                            Setting
               Start ~Stop Frequency                               9KHz~150KHz/RB 200Hz for QP
               Start ~Stop Frequency                               150KHz~30MHz/RB 9KHz for QP
               Start ~Stop Frequency                             30MHz~1000MHz/RB 120KHz for QP


              Receiver Parameter                                             Setting
               Start ~Stop Frequency                               9KHz~150KHz/RB 200Hz for QP
               Start ~Stop Frequency                               150KHz~30MHz/RB 9KHz for QP
               Start ~Stop Frequency                             30MHz~1000MHz/RB 120KHz for QP


                                                           Report No.: AGC01684180501FE06
                                                                              Page 13 of 26


7.3. TEST SETUP
                  Radiated Emission Test-Setup Frequency Below 30MHz




                   RADIATED EMISSION TEST SETUP 30MHz-1000MHz


                                                                       Report No.: AGC01684180501FE06
                                                                                          Page 14 of 26


7.4. TEST RESULT
                                 RADIATED EMISSION BELOW 30MHZ
EUT:               Handheld Fingerprint Terminal      Model Name             TPS360
Temperature:       20 ℃                               Relative Humidtity:    48%
Pressure:          1010 hPa                           Test Voltage :         DC 3.8V
Test Mode :        Mode 1                             Polarization :


                              Correction
 Frequency       Reading                     Result         Limit      Margin          Polar     Detector
                               Factor
   MHz           dBuV/m         dB/m        dBuV/m        dBuV/m            dB     Side/Face
  13.5610          51.95        -6.29        45.66          124         -78.34         Side       Peak
  27.1220          37.86        -7.03        30.83          69.5        -38.67         Side       Peak
  13.5610          52.04        -6.29        45.75          124         -78.25         Face       Peak
  27.1220          37.38        -7.03        30.35          69.5        -39.15         Face       Peak


Note: Other emissions from 9 kHz to 30 MHz are considered as ambient noise. No recording in the test
       report.


                                                                Report No.: AGC01684180501FE06
                                                                                   Page 15 of 26


                             RADIATED EMISSION 30MHz- 1GHZ
EUT:           Handheld Fingerprint Terminal   Model Name            TPS360
Temperature:   20 ℃                            Relative Humidtity:   48%
Pressure:      1010 hPa                        Test Voltage :        DC 3.8V
Test Mode :    Mode 1                          Polarization :        Horizontal




RESULT: PASS


                                                                          Report No.: AGC01684180501FE06
                                                                                             Page 16 of 26




EUT:               Handheld Fingerprint Terminal       Model Name              TPS360
Temperature:       20 ℃                                Relative Humidtity:     48%
Pressure:          1010 hPa                            Test Voltage :          DC 3.8V
Test Mode :        Mode 1                              Polarization :          Vertical




RESULT: PASS
Note:
    Factor=Antenna Factor + Cable loss, Margin=Result-Limit.
    The “Factor” value can be calculated automatically by software of measurement system.
    The mode 1 is the worst case, and only the data of the worst case recorded in this test report.


                               ®
  A\G
                                       3       TF
                                               mize
                                                       H 1 J
                                       Attestation of Global Compliance
                                                                                                                                                  :
                                                                                                                                Report No.: AGC01684180501FEO6
                                                                                                                                                                    Page 17 of 26


    8. FREQUENCY STABILITY
    8.1. MEASUREMENT PROCEDURE
           1. Connect EUT RF output port to the Spectrum Analyzer through an RF attenuator
           2. Set the EUT Work on the operation frequency.
           3. Set SPA Centre Frequency = Operation Frequency, RBW= 1 KHz, VBW >3 X RBW.
           4. Set SPA Trace 1 Max hold, then View.
           5. The test extreme voltage is to change the primary supply voltage from 85 to 115 percent of the nominal
             value
           6. Extreme temperature rule is —20°C~50°C.



    8.2. TEST SET—UP (BLOCK DIAGRAM OF CONFIGURATION)

                  Spectrum Analyzer
                       1                                                                  OVE
                       A
                           H_ HH
                              o
                                                                                          «2          O EUT—
                           i                         +                                    *
     LOk
     EoL




The results ,n' & virl fii@;}" kreport refer only to the sample(s) tested unless otherwise stated and the sample(s) are retained for 30 days only. The document
is issued by/A C§€ this docu/fi it cannot be reproduced except in full with our prior written permission. The more details and the authenticity of the report will be
confirmed tfittp://www.agc-% t.com.
              o

Attestatic m                     ® )        i                Tel: +86—755 2908 1955            Fax: +86—755 2600 8484             E—mail: agc@age—cert.com             @ 400 089 2118
                           iN¥                               Add: 2/F. , Building 2, No.1—4, Chaxi Sanwei Technical Industrial Park,Gushu, Xixiang, Bacan District, Shenzhen, Guangdong China


  AG                        °s 7 1 & m
                               Attestation of Global Compliance
                                                                                                                         Report No.: AGC01684180501FEO6
                                                                                                                                                             Page 18 of 26


    8.3. MEASUREMENT RESULTS

    Operating frequency: 13.561MHz


    Voltage vs. Frequency Stability (Test Temperature: 20°C)


         Voltage(V)                  Fr'\é'gj;fiéir?&fiz)                    Max'(l\t/l)fi‘g)afi"”                         Limit(MHz)                           Conclusion
             3.8                         13.56139
            3.42                         13.56138                                0.00040                                0.001356                                 PaASS
            4.18                         13.56140

    Temperature vs. Frequency Stability (Test Voltage: 5.0V)


        Temperature                  Fr'\é'gj;fiéir?&fiz)                    Max'(,\afi‘g)afi"”                            Limit(MHz)                           Conclusion
           — 20°C                        13.56138
            A10°C                        13.56137
             0°C                         13.56137
            10°C                         13.56139
            e                            Te tamss                                0.00039                                0.001356                                 Pass
              30°C                         13.56136
              40°C                         13.56138
              50°C                         13.56139




The results ’r.z6tison|
                   o thisfea
                           ost report refer only to the sample(s) tested unless otherwise stated and the sample(s) are retained for 30 days only. The document
is issued by/A C§€ this docu/® it cannot be reproduced except in full with our prior written permission. The more details and the authenticity of the report will be
confirmed tfittp://www.agc-% t.com.
            o

                                  pliance             Tel: +86—755 2908 1955            Fax: +86—755 2600 8484             E—mail: agc@agc—cert.com             @ 400 089 2118
                                                      Add: 2/F. , Building 2, No.1—4, Chaxi Sanwei Technical Industrial Park,Gushu, Xixiang, Bacan District, Shenzhen, Guangdong China


                            ®
  A\G
                                      3       TF
                                              mize
                                                      H 1 J
                                      Attestation of Global Compliance
                                                                                                                                                 :
                                                                                                                               Report No.: AGC01684180501FEO6
                                                                                                                                                                   Page 19 of 26


    9. 20DB BANDWIDTH
    9.1. MEASUREMENT PROCEDURE
       1. Connect EUT RF output port to the Spectrum Analyzer through an RF attenuator
       2. Set the EUT Work on the operation frequency.
       3. Set SPA Centre Frequency = Operation Frequency, RBW= 1 KHz, VBW >3 X RBW.
       4. Set SPA Trace 1 Max hold, then View.


    9.2. TEST SET—UP (BLOCK DIAGRAM OF CONFIGURATION)

                                                                                                 Spectrum Analyzer




                                                                                  RF Cable
                                                                                              SE               T




                    EUT




The results ,n. virl fii@;}" kreport refer only to the sample(s) tested unless otherwise stated and the sample(s) are retained for 30 days only. The document
is issued by/A  this doc@ it cannot be reproduced except in full with our prior written permission. The more details and the authenticity of the report will be
confirmed tfittp://www.agc-% t.com.
             o

Attestatic                      ® )        i                Tel: +86—755 2908 1955            Fax: +86—755 2600 8484             E—mail: agc@age—cert.com             @ 400 089 2118
                          iN¥                               Add: 2/F. , Building 2, No.1—4, Chaxi Sanwei Technical Industrial Park,Gushu, Xixiang, Bacan District, Shenzhen, Guangdong China


                                                  Report No.: AGC01684180501FE06
                                                                     Page 20 of 26


9.3. MEASUREMENT RESULTS

TEST ITEM                20DB BANDWIDTH

TEST MODE                Mode1


                        Test Data (kHz)                          Criteria
             Operate channel              2.858                   PASS


                                                                              Report No.: AGC01684180501FE06
                                                                                                 Page 21 of 26


10. FCC LINE CONDUCTED EMISSION TEST
10.1. LIMITS OF LINE CONDUCTED EMISSION TEST

                                                               Maximum RF Line Voltage
             Frequency
                                                    Q.P.( dBuV)                        Average( dBuV)
          150kHz~500kHz                                66-56                                 56-46
           500kHz~5MHz                                   56                                    46
           5MHz~30MHz                                    60                                    50
Note:
1. The lower limit shall apply at the transition frequency.
2. The limit decreases linearly with the logarithm of the frequency in the range 0.15 MHz to 0.50 MHz.


10.2. BLOCK DIAGRAM OF LINE CONDUCTED EMISSION TEST



                  EUT & Support
                  Units


                                                                          Report No.: AGC01684180501FE06
                                                                                             Page 22 of 26


10.3. PRELIMINARY PROCEDURE OF LINE CONDUCTED EMISSION TEST
1. The equipment was set up as per the test configuration to simulate typical actual usage per the user’s
   manual. When the EUT is a tabletop system, a wooden table with a height of 0.8 meters is used and is
   placed on the ground plane as per ANSI C63.10 (see Test Facility for the dimensions of the ground plane
   used). When the EUT is a floor-standing equipment, it is placed on the ground plane which has a 3-12
   mm non-conductive covering to insulate the EUT from the ground plane.
2. Support equipment, if needed, was placed as per ANSI C63.10.
3. All I/O cables were positioned to simulate typical actual usage as per ANSI C63.10.
4. All support equipments received AC120V/60Hz power from a LISN, if any.
5. The EUT received charging voltage by adapter which received 120V/60Hzpower by a LISN..
6. The test program was started. Emissions were measured on each current carrying line of the EUT using a
   spectrum Analyzer / Receiver connected to the LISN powering the EUT. The LISN has two monitoring
   points: Line 1 (Hot Side) and Line 2 (Neutral Side). Two scans were taken: one with Line 1 connected to
   Analyzer / Receiver and Line 2 connected to a 50 ohm load; the second scan had Line 1 connected to a
   50 ohm load and Line 2 connected to the Analyzer / Receiver.
7. Analyzer / Receiver scanned from 150 kHz to 30MHz for emissions in each of the test modes.
8. During the above scans, the emissions were maximized by cable manipulation.
9. The test mode(s) were scanned during the preliminary test.

Then, the EUT configuration and cable configuration of the above highest emission level were recorded for
reference of final testing.


10.4. FINAL PROCEDURE OF LINE CONDUCTED EMISSION TEST
1.   EUT and support equipment was set up on the test bench as per step 2 of the preliminary test.
2.    A scan was taken on both power lines, Line 1 and Line 2, recording at least the six highest emissions.
     Emission frequency and amplitude were recorded into a computer in which correction factors were used
     to calculate the emission level and compare reading to the applicable limit. If EUT emission level was
     less –2dB to the A.V. limit in Peak mode, then the emission signal was re-checked using Q.P and Average
     detector.
3.    The test data of the worst case condition(s) was reported on the Summary Data page.


                                                         Report No.: AGC01684180501FE06
                                                                            Page 23 of 26


10.5. TEST RESULT OF LINE CONDUCTED EMISSION TEST
                          LINE CONDUCTED EMISSION TEST LINE -L




RESULT: PASS


                                                      Report No.: AGC01684180501FE06
                                                                         Page 24 of 26


               Line Conducted Emission Test Line -N




RESULT: PASS


                                   Report No.: AGC01684180501FE06
                                                      Page 25 of 26


APPENDIX A: PHOTOGRAPHS OF TEST SETUP
 RADIATED EMISSION TEST SETUP BELOW 1GHz


                                 Report No.: AGC01684180501FE06
                                                    Page 26 of 26


FCC LINE CONDUCTED EMISSION TEST SETUP




        ----END OF REPORT----



Document Created: 2018-07-12 14:38:06
Document Modified: 2018-07-12 14:38:06

© 2024 FCC.report