Test Report

FCC ID: 2AJ2A-ANCHORV1

Test Report

Download: PDF
FCCID_4039713

                                              TEST REPORT
                                             No.: 18-1-0039001T03a



                                                           According to:
                                                          FCC Regulations
                                                            Part 15.517




                                                                 for

                                            Intel Deutschland GmbH

                                            Shooting Star Mini Anchor



                                            FCC ID: 2AJ2A-ANCHORV1



                                            Laboratory Accreditation and Listings



                                                                                     Voluntary Controls for Electromagnetic
                                                        Industry Canada
                                                                                                  Emissions
                                                       Reg. No.: 3462D-1
                                                       Reg. No.: 3462D-2                          Reg. No.:
           Accredited EMC-Test Laboratory              Reg. No.: 3462D-3                      R-20013, C-20009,
                                                                                              T-20006, G-20013




                                                                                               MRA US-EU 0003

                                      accredited according to DIN EN ISO/IEC 17025

                                                       CETECOM GmbH
                               Laboratory Radio Communications & Electromagnetic Compatibility
                                           Im Teelbruch 116 • 45219 Essen • Germany
                                  Registered in Essen, Germany, Reg. No.: HRB Essen 8984
                                Tel.: + 49 (0) 20 54 / 95 19-954 • Fax: + 49 (0) 20 54 / 95 19-964
                                    E-mail: info@cetecom.com • Internet: www.cetecom.com


                                            Laboratory Accreditation and Listings




                                                                                                                       Page 1 of 26
The test results relate only to the individual items which have been tested. This report shall not be reproduced in parts without the
written approval of the testing laboratory                                         © Copyright: All rights reserved by CETECOM


Test Report 18-1-0039001T03a, Page 2 of 26


Table of contents

1. SUMMARY OF TEST RESULTS................................................................................................................... 3
  1.1. Tests measurement overview according of US CFR Title 47, Subpart 15C: ................................................ 3
  1.2. Attestation:.................................................................................................................................................... 4
2. ADMINISTRATIVE DATA ............................................................................................................................ 5
  2.1. Identification of the testing laboratory .......................................................................................................... 5
  2.2. Test location ................................................................................................................................................. 5
  2.3. Organizational items ..................................................................................................................................... 5
  2.4. Applicant’s details ........................................................................................................................................ 5
  2.5. Manufacturer’s details .................................................................................................................................. 5
3. EQUIPMENT UNDER TEST (EUT) .............................................................................................................. 6
  3.1. TECHNICAL DATA OF MAIN EUT DECLARED BY APPLICANT ...................................................... 6
  3.2. EUT: Type, S/N etc. and short descriptions used in this test report ............................................................. 6
  3.3. Auxiliary Equipment (AE): Type, S/N etc. and short descriptions ............................................................... 6
  3.4. EUT set-ups .................................................................................................................................................. 7
  3.5. EUT operating modes ................................................................................................................................... 7
4. DESCRIPTION OF TEST SYSTEM SET-UP’S ........................................................................................... 8
  4.1. Test system set-up for radiated magnetic field measurements below 30 MHz ............................................. 8
  4.2. Test system set-up for radiated electric field measurement 30 MHz to 960MHz ......................................... 9
  4.3. Test system set-up for radiated electric field measurement above 960MHz .............................................. 10
5. MEASUREMENTS ........................................................................................................................................ 11
  5.1. Transmission time measurement ................................................................................................................ 11
  5.2. 10 dB bandwidth measurement ................................................................................................................... 12
  5.3. General Limit - Radiated field strength emissions below 30 MHz ............................................................. 13
  5.4. General Limit - Radiated field strength emissions, 30 MHz – 960 MHz ................................................... 15
  5.5. General Limit – Radiated field strength emissions, above 960 MHz ......................................................... 17
  5.6. Radiated emissions in the GPS bands ......................................................................................................... 19
  5.7. Fundamental emission peak power ............................................................................................................. 20
  5.8. Antenna requirement according to FCC 15.203 ......................................................................................... 20
  5.9. Measurement uncertainties ...................................................................................................................... 21
6. ABBREVIATIONS USED IN THIS REPORT ............................................................................................ 22
7. ACCREDITATION DETAILS OF CETECOM’S LABORATORIES AND TEST SITES .................... 22
8. INSTRUMENTS AND ANCILLARY ........................................................................................................... 23
  8.1. Used equiment “CTC” ............................................................................................................................. 23
9. VERSIONS OF TEST REPORTS (CHANGE HISTORY) ........................................................................ 26


Table of annex
Separate document annex 1: Measurement diagrams
Separate document annex 2: External photographs of EUT
Separate document annex 3: Test set-up photographs
Separate document annex 4: Internal photographs of EUT

The listed attachments are an integral part of this report.




CETECOM_TR18_1_0039001T03a


Test Report 18-1-0039001T03a, Page 3 of 26


1. Summary of test results
The test results apply exclusively to the test samples as presented in this report. The CETECOM GmbH
does not assume responsibility for any conclusions and generalizations taken in conjunction with other
specimens or samples of the type of the item presented to tests. Also we refer on special conditions which
the applicant should fulfill according §2.927 to §2.948, special focus regarding modification of the
equipment and availability of sample equipment for market surveillance tests.
The presented Equipment Under Test (in this report, hereinafter referred as EUT) supports radiofrequency
technologies with similar UWB technology and operating frequency range at 3.1 to 4.8 GHz. Other implemented
wireless technologies were not considered within this test report.

Following test cases have been performed to show compliance with valid Part 15.209/15.517 of the FCC CFR
Title 47 Rules, Edition 4th November 2014.

1.1. Tests measurement overview according of US CFR Title 47, Subpart 15C:
                                             References & Limits                            EUT
                                                                                   EUT     opera-
  Test cases           Port                                                                           Result
                                  FCC Standard               Test Limit           set-up    ting
                                                                                           mode
                                                   TX-Mode
 Transmission        Antenna
                     terminal      §15.517(a)(5)                   -                2         1       passed
     time
                     (radiated)

     10 dB           Antenna
                     terminal        §15.517(b)          3.1 GHz – 10.6 GHz         1        1,2      passed
   bandwidth
                     (radiated)
                    Enclosure +                         Emissions in restricted
                      Inter-          §15.209                                       1         1       passed
   Radiated                                              bands must meet the
   emissions        connecting                          general field-strength
                      cables         §15.517(c)             radiated limits         1         1       passed
                     (radiated)
                    Enclosure +
    Radiated          Inter-
  emissions in      connecting       §15.517(d)               -85.3 dBm             1         1       passed
 the GPS bands        cables
                     (radiated)
               Enclosure +
  Fundamental    Inter-
 emission peak connecting            §15.517(e)       0 dBm for RBW=50 MHz          1         1       passed
     power       cables
                     (radiated)
    Antenna
                         -            §15.203                      -                -         -       passed
  requirement
* See chapter 3.4




CETECOM_TR18_1_0039001T03a


Test Report 18-1-0039001T03a, Page 4 of 26

1.2. Attestation:
I declare that all measurements were performed by me or under my supervision and that all measurements have been performed and are correct
to my best knowledge and belief to Industry Canada standards. All requirements as shown in above table are met in accordance with enumerated
standards.
                           Digital unterschrieben von                                                                       Digital unterschrieben von
                           Niels Jeß                                                                                        Piotr Sardyko
                           DN: cn=Niels Jeß,                                                                                DN: cn=Piotr Sardyko,
                           o=CETECOM GmbH,                                                                                  o=CETECOM GmbH,
                           ou=Branch Duesseldorf,                                                                           ou=Radio Communications
                           email=niels.jess@cetecom.c
                                                                                                                            & EMC,
                           om, c=DE
                           Datum: 2018.09.14 14:09:04                                                                       email=piotr.sardyko@ceteco
                           +02'00'                                                                                          m.com, c=DE
......................................................                                             ....................................................
Dipl.-Ing. Niels Jeß                                                                                                   B.Sc. Piotr Sardyko
Responsible for test section                                                                                 Responsible for test report




CETECOM_TR18_1_0039001T03a


Test Report 18-1-0039001T03a, Page 5 of 26


2. Administrative Data
2.1. Identification of the testing laboratory
Company name:                                                         CETECOM GmbH
Address:                                                              Im Teelbruch 116
                                                                      45219 Essen - Kettwig
                                                                      Germany
Responsible for testing laboratory:                                   Dipl.-Ing. Rachid Acharkaoui
Deputy:                                                               Dipl.-Ing. Niels Jeß

2.2. Test location
2.2.1. Test laboratory “CTC”
Company name:                                                         see chapter 2.1. Identification of the testing laboratory

2.3. Organizational items

Responsible for test report and
project leader:                                                       B.Sc. Piotr Sardyko
Receipt of EUT:                                                       2018-07-16
Date(s) of test:                                                      2018-07-16 to 2018-07-17
Date of report:                                                       2018-09-14
       -----------------------------------------------------------------------------------------------------------------------------------------------------

Version of template:             13.02

2.4. Applicant’s details

Applicant’s name:                                                     Intel Deutschland GmbH
Address:                                                              Am Campeon 10-12
                                                                      85579 Neubiberg
                                                                      Germany

Contact person:                                                       Gäde-Tsangas, Andreas Dr.

2.5. Manufacturer’s details

Manufacturer’s name:                                                  please see Applicant's details

Address:                                                              please see Applicant's details




CETECOM_TR18_1_0039001T03a


Test Report 18-1-0039001T03a, Page 6 of 26


3. Equipment under test (EUT)
3.1. TECHNICAL DATA OF MAIN EUT DECLARED BY APPLICANT
Main function                          Anchor
Device type                            Mobile Device
Frequency range                        6000 MHz - 7000 MHz
Type of modulation                     BPSK with BPM
Number of channels                     1 UWB channels
EMISSION DESIGNATOR(S)                 IEEE 802.15.4-2011 UWB
Antenna Type                            Integrated
                                        External, no RF- connector
                                        External, separate RF-connector
MAX Field strength (radiated):         54 dBμV/m@3m distance and 1 MHz RBW
Power supply                            DC power supply: 5 V
EUT sample type                         Production                  Pre-Production                   Engineering
FCC label attached                      yes                         no


3.2. EUT: Type, S/N etc. and short descriptions used in this test report
Short
                                                                        S/N                 HW                SW
descrip-                EUT                     Type
                                                                   serial number       hardware status   software status
tion*)
                                         Shooting Star Mini
 EUT A                Anchor                                         1000007                DVT              WW29
                                              Anchor

             Anchor (only for Time       Shooting Star Mini
 EUT B                                                               8330205                DVT              WW35
              Measurement test)               Anchor
*) EUT short description is used to simplify the identification of the EUT in this test report.
3.3. Auxiliary Equipment (AE): Type, S/N etc. and short descriptions
AE          Auxiliary Equipment      Type                      S/N           HW                   SW
short                                                          serial number hardware             software status
descrip-                                                                     status
tion *)
                                                                                                  Windows 10 + PuTTY
  AE 1      Notebook                 HP EliteBook 8540w        -                   -
                                                                                                  Release 0.68

            Power Bank
  AE 2                               Huawei AP007              -                   -              -
            13000 mAh/46.8Wh

  AE 3      USB cable                2m                        -                   -              -

                                                                                                  Windows 10 + Intel
                                                                                                  ILT Network Manager
  AE 4      Notebook                 HP ZBook 15 G3            -                   -
                                                                                                  dd2c478, Firmware
                                                                                                  3.2.228

                                     Intel Deutschland
  AE 5      Coordinator              GmbH, IntelPN                  8330207            DVT                WW35
                                     J97409-002

                                     Intel Deutschland
  AE 6      Sniffer                  GmbH, IntelPN                  8330210            DVT                WW35
                                     J97409-002



CETECOM_TR18_1_0039001T03a


Test Report 18-1-0039001T03a, Page 7 of 26


             Portable charger         LITE 2600 3.7V Li-
  AE 7                                                          3363223         -            -
             Battery                  Ion, 2600mAh

             USB cable to connect
  AE 8                                1.5 m                     -               -            -
             EUT B and AE7

                                                                MAC: 94-
             Intel NUC Kit            Product code:
  AE 9                                                          C6-91-1D-       -            -
             NUC7i5BNKP               BOXNUC7i5BNK
                                                                F5-AB

             TP-LINK USB 3.0 to
                                                                21681440015
  AE 10      Gigabit Ethernet         Model: UE300                          -                -
                                                                47 UN/1.0
             Network Adapter

             USB cable to connect
  AE 11                               1.5 m                     -               -            -
             AE7 and AE10

             LAN cable to connect
  AE 12                               0.5 m                     -               -            -
             AE10 and AE11

             Mains adapter for
  AE 13                               -                         -               -            -
             AE10
*) AE short description is used to simplify the identification of the auxiliary equipment in this test report.


3.4. EUT set-ups

 EUT set-up
                       Combination of EUT and AE                                      Remarks
   no.*)

                                                                    Radiated RF-setup, AE1 and AE2 are used
    set. 1            EUT A + AE 1 + AE 3 + AE 4
                                                                    temporary for EUT placing into operation

    set. 2                EUT B + AE 4 to AE 13                        Transmission time measurement test
*) EUT set-up no. is used to simplify the identification of the EUT set-up in this test report.


3.5. EUT operating modes
    EUT
                      Description of operating modes
  operating                                                                   Additional information
 mode no.*)

              TX, channel 5, PRF 64 MHz, datarate 850k,
                                                               Continuous TX-Mode, set-up by special software
    op. 1        PreambleCode default auf channel 5,
                                                                           and with help of PC.
                           PreambleCode 9
                 TX, channel 5, PRF 64 MHz, datarate
                                                               Continuous TX-Mode, set-up by special software
    op. 2      6800k, PreambleCode default auf channel
                                                                           and with help of PC.
                          5, PreambleCode 9
*) EUT operating mode no. is used to simplify the test report.




CETECOM_TR18_1_0039001T03a


Test Report 18-1-0039001T03a, Page 8 of 26


4. Description of test system set-up’s
4.1. Test system set-up for radiated magnetic field measurements below 30 MHz


 Specification:              ANSI C63.4-2014 §5.3, §8.2.1, §8.3.1.1+§8.3.2.1 , ANSI C63.10-2013 chapter
                             6.4 (§6.4.4.2)

 General Description:        Evaluating the radiated field emissions are done first by an exploratory emission
                             measurement and a final measurement for most critical frequencies determined.
                             The loop antenna was placed at 1 m height above ground plane and 3 m
                             measurement distance from set-up for investigations. Because of reduced
                             measurement distance, correction data were applied, as stated in chapter “General
                             Limit - Radiated field strength emissions below 30 MHz“. The tests are performed
                             in the semi anechoic room recognized by the regulatory commission.

 Schematic:




 Testing method:             Exploratory, preliminary measurement                 Final measurement on critical frequencies
                             The EUT and it’s associated accessories are          Based on the exploratory measurements, the most
                             placed on a non-conductive position manipulator      critical frequencies are re-measured by main-
                             (tipping device) of 0.8 m height which is placed     taining the EUT’s worst-case operation mode,
                             on the turntable. By rotating the turntable (step    cable position, etc.
                             90°, range 0°to 360°) and the EUT itself either on
                             3-orthogonal axis (portable equipment) or 2-         First a frequency zoom around the critical
                             orthogonal axis (defined operational position of     frequency is done to locate the frequency more
                             EUT), the emission spectrum was recorded. The        precisely. After this step, for all identified critical
                             loop antenna was moved at least to                   frequencies, the maximum peak was determined.
                             2-perpendicular axes (antenna vector in direction
                             of EUT and parallel to EUT) in order to maximize     Following parameters were varied: the turntable
                             the emissions. The results are documented in a       angle continuously in the range 0 to 360 degree,
                             diagram. Critical frequencies (low margin to         the EUT itself either over 3-orthogonal axis (not
                             limit) are saved within a data reduction table for   defined usage position) or 2-orthogonal axis
                             further investigations. If various operating modes   (defined usage position).
                             are supported, further investigations are made to
                             find the worst-case. Also the interconnection        On the determined worst-case position, a final
                             cables and equipment position were varied in         measurement with necessary bandwidth and
                             order to maximize the emissions.                     detector according standard has been carried out.

 Formula:                    EC = ER + AF + CL + DF - GA               AF =Antenna factor
                                                                       CL = Cable loss
                             M = LT-EC                                 DF= Distance correction factor
                                                                       EC = Electrical field – corrected value
                                                                       ER = Receiver reading
                                                                       GA= Gain of pre-amplifier (if used)
                                                                       LT = Limit
                                                                       M = Margin
                             All units are dB-units, positive margin means value is below limit.

 Distance correction:        Reference for applied correction (extrapolating) factors due to reduced
                             measurement distance:
                             ANSI C63.10:2013, §6.4.4.2 - Equations (2) + (3) + (4)



CETECOM_TR18_1_0039001T03a


Test Report 18-1-0039001T03a, Page 9 of 26

4.2. Test system set-up for radiated electric field measurement 30 MHz to 960MHz


 Specification:              ANSI C63.4-2014 chapter 8.2.3, ANSI C63.10-2013 chapter 6.5

 General Description:        Evaluating the field emissions have to be done first by an exploratory emissions
                             measurement and a final measurement for most critical frequencies. The tests are
                             performed in a NSA-compliant semi anechoic room (SAR) recognized by the
                             regulatory commissions.

 Schematic:




 Testing method:             Exploratory, preliminary measurements                Final measurement on critical frequencies
                             The EUT and its associated accessories are placed    Based on the exploratory measurements, the most
                             on a non-conductive position manipulator (tipping    critical frequencies are re-measured by main-
                             device) of 0.8 m height which is placed on the       taining the EUT’s worst-case operation mode, cable
                             turntable. By rotating the turntable (range 0° to    position, etc. either on 10m OATS or 3m semi-
                             360°, step 90°) and the EUT itself either on 3-      anechoic room.
                             orthogonal axis (portable equipment) or 2-
                             orthogonal axis (defined operational position of     First a frequency zoom around the critical frequency
                             EUT) the emission spectrum and it’s                  is done to locate the frequency more precisely. After
                             characteristics was recorded with an EMI-            this step, for all identified critical frequencies, the
                             receiver, broadband antenna and software.            maximum peak was determined.

                             Measurement antenna: horizontal and vertical,        Following parameters were varied: the turntable
                             heights: 1,0 m and 1,82 m as worst-case              angle continuously in the range 0 to 360 degree, the
                             determined by an exploratory emission                EUT itself either over 3-orthogonal axis (not
                             measurements. The results are documented in a        defined usage position) or 2-orthogonal axis
                             diagram. Critical frequencies (low margin to         (defined usage position). The measurement antenna
                             limit) are saved within a table for further          height between 1 m and 4 m.
                             investigations. If various operating modes are
                             supported, further investigations are made to find   On the determined worst-case position, a final
                             the worst-case of them. Also the interconnection     measurement with necessary bandwidth and
                             cables and equipment position were varied in         detector according standard has been carried out.
                             order to maximize the emissions.

 Formula:                    EC = ER + AF + CL + DF - GA (1)           AF = Antenna factor
                                                                       CL = Cable loss
                             M = LT - EC         (2)                   DF = Distance correction factor (if used)
                                                                       EC = Electrical field – corrected value
                                                                       ER = Receiver reading
                                                                       GA = Gain of pre-amplifier (if used)
                                                                       LT = Limit
                                                                       M = Margin
                             All units are dB-units, positive margin means value is below limit.




CETECOM_TR18_1_0039001T03a


Test Report 18-1-0039001T03a, Page 10 of 26

4.3. Test system set-up for radiated electric field measurement above 960MHz


 Specification:              ANSI C63.10-2013, chapter 10.3

 General Description:        The tests are performed in a CISPR 16-1-4:2010 compliant fully anechoic room
                             (FAR) recognized by the regulatory commission. The measurement distance was
                             set to 1 m or 3 m. Horn antennas are used for frequency range 1 GHz to 40 GHz.
                             The EUT is aligned within 3 dB beam width of the measurement antenna with three
                             orthogonal axis measurements on the EUT.

 Schematic:




 Testing method:             Exploratory, preliminary measurements
                             The EUT and its associated accessories are placed on a non-conductive position manipulator (tipping
                             device) of 1.55 m height which is placed on the turntable. By rotating the turntable continuously (range
                             0° to 360°) and the EUT itself either on 3-orthogonal axis (portable equipment) or 2-orthogonal axis
                             (defined operational position of EUT) the emission spectrum and it’s characteristics was recorded with
                             an EMI-receiver, broadband antenna and software.
                             The measurements are performed in horizontal and vertical polarization of the measurement antennas.
                             The results are documented in a diagram. Also the interconnection cables and equipment position were
                             varied in order to maximize the emissions.

 Formula:                    EC = ER + AF + CL + DF - GA (1)           EC = Electrical field – corrected value
                                                                       ER = Receiver reading
                             M = LT - EC         (2)                   M = Margin
                                                                       LT = Limit
                                                                       AF = Antenna factor
                                                                       CL = Cable loss
                                                                       DF = Distance correction factor (if used)
                                                                       GA = Gain of pre-amplifier (if used)
                             All units are dB-units, positive margin means value is below limit.




CETECOM_TR18_1_0039001T03a


Test Report 18-1-0039001T03a, Page 11 of 26


5. Measurements
5.1. Transmission time measurement
5.1.1. Test location and equipment
  Ref.-No.




                                Equipment                                        Type                             Serial-No.


Conducted measurement
714     Spectrum Analyzer                                         R&S FSU67                           104023
133     Antenna                                                   EMCO 3115                           9012-3629
-       RF Amplifier                                              Wright Technologies ASG18B-4010     -


5.1.2. Reference
 FCC                    §15.517 (5)


5.1.3. EUT settings:
The EUT is switched on.

5.1.4. Test condition and measurement test set-up
 EUT-grounding                               none          with power supply    additional connection
 Equipment set up                            table top 1.5 m height              floor standing
 Climatic conditions                        Temperature: (22±3°C)                Rel. humidity: (40±20)%

5.1.5. Measurement method and analyzer settings:
The measurement is made radiated. The EUT B is placed in the FAC. AEs are laying on the table not far from the
door of the FAC. The intentional radiators are coordinator and sniffer. Anchor, coordinator and sniffer are working
together as a system. The manufacturer provides the following description of the work of the whole system:

Anchors are placed in the environment where indoor drone flights take place. A number of anchors are spatially
separated to bound the drone flying 3D space. Those anchors will function as location reference (conceptually
similar to Indoor satellites), so that each Indoor Drone can calculate their own locations based on the relative
measurements between each drone and each anchor.
Coordinator is a special case of an anchor. Coordinator is responsible for scheduling network operations,
approving anchors/drones to join the network, clock synchronization across the network, etc.
Sniffer is a special case of an anchor. Sniffer is responsible for receiving all anchors messages and pass the anchor
reported data to UWB server for anchor location computation. Sniffer is also responsible for publishing anchor
locations to respective anchors, and for transmitting Drone control center or network management center
originated commands to control UWB network operations.
Anchor/Coordinator/Sniffer selection can been done by switch in HW ie. PCB/HW/mechanics/FW are identical in
Anchor/Coordinator/Sniffer functionality.

The EUT B should NOT transmit outside of the whole system. In the first measurement EUT B and all AEs are
ON. The door of the FAC is closed. It is measured, whether the EUT B transmits outside of the whole system. The
measurement is made in time domain by the central frequency of the channel. Measurement duration 60 s. RBW
= 1 MHz. The measurement shows that the EUT doesn’t transmit respectively works properly.

In the second measurement EUT B and all AEs are also ON. In the first 30 s of the measurement the door of the
FAC is open. After these 30 s the door is closed. It is checked whether the EUS B transmits when the
communication with the whole system is interrupted. The measurement shows that the EUT stopes to transmit in
a few seconds after its disconnection from the whole system.

5.1.6. RESULTS
When the communication with the intentional radiators is ceased, the EUT stopes to transmit.

5.1.6.1. VERDICT: PASS. For graphical results pls. see annex 1 to this test report.




CETECOM_TR18_1_0039001T03a


Test Report 18-1-0039001T03a, Page 12 of 26

5.2. 10 dB bandwidth measurement
5.2.1. Test location and equipment
  Ref.-No.




                                        Equipment                                       Type                              Serial-No.


714              Spectrum Analyzer                                       R&S FSU67                            104023
133              Antenna                                                 EMCO 3115                            9012-3629
-                RF Amplifier                                            Wright Technologies ASG18B-4010      -


5.2.2. Reference
 FCC                           §15.517 5b


5.2.3. Test condition and measurement test set-up
 EUT-grounding                                       none         with power supply    additional connection
 Equipment set up                                    table top                          floor standing
 Climatic conditions                                Temperature: (22±3°C)               Rel. humidity: (40±20)%

5.2.4. EUT Settings:
The measurement is made radiated. The EUT was instructed to transmit continuously with maximum power (if
adjustable) according applicants declared and applicable settings.
Different characteristics have been checked, e.g. data rates which EUT can operate if applicable.

5.2.5. Measurement method:
The frequency at which the maximum power level is measured with the peak detector is designated fM (RBW=1
MHz, VBW= 3 MHz, peak detection, maxhold). The outermost 1 MHz segments above and below fM, where the
peak power falls by 10 dB relative to the level at fM, are designated as fH and fL. The UWB transmission, and the
-10 dB bandwidth (B - 10), is defined as (fH - fL). -10 dB bandwidth should be ≥500 MHz and must be contained
between 3100 MHz and 10.600 MHz.

5.2.6. Spectrum-Analyzer settings:
     Span                                  1.5 GHz
     Resolution Bandwidth                  ANSI 63.10-2013, chapter 10.1
     (RBW)
     Video Bandwidth (VBW)                 Minimum 3 times the resolution bandwidth
     Sweep time                            Auto-coupled
     Detector                              Peak detector
     Sweep mode                            Repetitive Mode, MAX-HOLD, trace stabilization

5.2.7. Results:

                          The frequency
                                                    Power at the             Lowest                 Highest                  -10 dB
        Op.                  with the
                                                    frequency fM,       frequency bound        frequency bound             bandwidth,
       Mode:             maximum power
                                                       [dBm]                fL, [MHz]              fH, [MHz]                 [MHz]
                            fM, [MHz]
             1                 6409,5                  -25,42                 6199,3                 6752,2                    552,9

             2                 6333,1                   -26,5                 6142,3                 6831,6                    689,3
Remark: For graphical results pls. see annex 1 to this test report.
The operation mode No 1 shows the highest power value. This mode will be used furthermore for other
measurements.

VERDICT: PASS




CETECOM_TR18_1_0039001T03a


Test Report 18-1-0039001T03a, Page 13 of 26

5.3. General Limit - Radiated field strength emissions below 30 MHz
5.3.1. Test location and equipment
 test location      CETECOM Essen (Chapter. 2.2.1)         Please see Chapter. 2.2.2               Please see Chapter. 2.2.3
 test site          441 EMI SAR  487 SAR NSA              347 Radio.lab.                                          
 receiver           377 ESCS30        001 ESS                                                                    
 spectr. analys.    584 FSU           120 FSEM            264 FSEK                                               
 antenna            574 BTA-L         133 EMCO3115        302 BBHA9170  289 CBL 6141             030 HFH-Z2  021 EMCO6502
 signalling         757 CMW500  371 CBT32                 547 CMU           594 CMW500
 otherwise          400 FTC40x15E  401 FTC40x15E          110 USB LWL  482 Filter Matrix         378 RadiSense
 DC power           456 EA 3013A  457 EA 3013A            459 EA 2032-50  268 EA- 3050           494 AG6632A  498 NGPE 40
 line voltage       230 V 50 Hz via public mains           060 120 V 60 Hz via PAS 5000



5.3.2. Requirements
         FCC             Part 15, Subpart C, §15.205 & §15.209
         ANSI            C63.10-2013
      Frequency                     Field strength limit             Distance
                                                                                                          Remarks
        [MHz]                [μV/m]               [dBμV/m]             [m]
    0.009 – 0.490         2400/f (kHz)     67.6 – 20Log(f) (kHz)       300        Correction factor used due to measurement distance of 3 m
    0.490 – 1.705        24000/f (kHz)     87.6 – 20Log(f) (kHz)       30         Correction factor used due to measurement distance of 3 m
      1.705 – 30               30                   29.5               30         Correction factor used due to measurement distance of 3 m



5.3.3. Test condition and test set-up
 EUT-grounding                                none          with power supply  additional connection
 Equipment set up                             table top                              floor standing
 Climatic conditions                         Temperature: (22±3°C)                   Rel. humidity: (40±20)%
                                              9 – 150 kHz             RBW/VBW = 200 Hz           Scan step = 80 Hz
                       Scan data              150 kHz – 30 MHz RBW/VBW = 9 kHz                   Scan step = 4 kHz
                                              other:
 EMI-Receiver or Scan-Mode                    6 dB EMI-Receiver Mode  3dB Spectrum analyser Mode
 Analyzer Settings Detector                  Peak (pre-measurement) and Quasi-PK/Average (final if applicable)
                   Mode:                     Repetitive-Scan, max-hold
                   Sweep-Time                Coupled – calibrated display if continuous signal otherwise adapted to EUT’s individual
                                             transmission duty-cycle
General measurement procedures               Please see chapter “Test system set-up radiated magnetic field measurements below 30 MHz”



5.3.4. Measurement Results
The results are presented below in summary form only. For more information please consult the diagrams included
in annex 1.

                                                    OP-
  Measurement
                         Frequency range            mode                        Remark                      Detector          Result
      No
                                                     no.

                                                                   Op. mode- worst case. Laying
         1                9 kHz-30 MHz                 1
                                                                            position.
                                                                                                             Peak             passed

                                                                   Op. mode- worst case. Standing
         2                9 kHz-30 MHz                 1
                                                                             position.
                                                                                                             Peak             passed




CETECOM_TR18_1_0039001T03a


Test Report 18-1-0039001T03a, Page 14 of 26

5.3.5. Correction factors due to reduced meas. distance (f< 30 MHz)

The used correction factors when the measurement distance is reduced compared to regulatory measurement
distance, are calculated according Extrapolation formulas valid for EUT’s with maximum dimension of
0.625xLambda. Formula 2+3+4 as presented in ANSI C63.10, Chapter 6.4.4 are used for the calculations of proper
extrapolation factors.




CETECOM_TR18_1_0039001T03a


Test Report 18-1-0039001T03a, Page 15 of 26

5.4. General Limit - Radiated field strength emissions, 30 MHz – 960 MHz
5.4.1. Test location and equipment
 test location      CETECOM Essen (Chapter. 2.2.1)        Please see Chapter. 2.2.2               Please see Chapter. 2.2.3
 test site          441 EMI SAR  487 SAR NSA
 receiver           377 ESCS30        001 ESS            489 ESU 40       620 ESU 26
 spectr. analys.    584 FSU           120 FSEM           264 FSEK
 antenna            574 BTA-L         133 EMCO3115       302 BBHA9170  289 CBL 6141      030 HFH-Z2  477 GPS
 signalling         392 MT8820A  371 CBT32               547 CMU          594 CMW
 otherwise          400 FTC40x15E  401 FTC40x15E         110 USB LWL  482 Filter Matrix
 DC power           456 EA 3013A  457 EA 3013A           459 EA 2032-50  268 EA- 3050    494 AG6632A  498 NGPE
 line voltage       230 V 50 Hz via public mains          060 120 V 60 Hz via PAS 5000



5.4.2. Requirements/Limits
                                              Part 15 Subpart B, §15.109, class B
                     FCC
                                              Part 15 Subpart C, §15.209 @ frequencies defined in §15.205
                                              C63.4-2014
                     ANSI
                                              C63.10-2013
                                                                      Radiated emissions limits, 3 meters
                         Frequency [MHz]
                                                        QUASI Peak [µV/m]                          QUASI-Peak [dBµV/m]
                              30 - 88                         100                                         40.0
     Limit
                             88 - 216                         150                                         43.5
                            216 - 960                         200                                         46.0
                            above 960                         500                                         54.0



5.4.3. Restricted bands of operation (FCC §15.205/ RSS-Gen, Issue 4 Chapter 8.9, Table 4)
                   MHz                            MHz                                   MHz                              GHz
  0.090-0.110                      16.42-16.423                         399.9-410                          4.5-5.15
  0.495-0.505                      16.69475-16.69525                    608-614                            5.35-5.46
  2.1735-2.1905                    16.80425-16.80475                    960-1240                           7.25-7.75
  4.125-4.128                      25.5-25.67                           1300-1427                          8.025-8.5
  4.20725-4.20775                  37.5-38.25                           1645.5-1646.5                      9.3-9.5
  6.215-6.218                      73-74.6                              1660-1710                          10.6-12.7
  6.26775-6.26825                  74.8-75.2                            1718.8-1722.2                      13.25-13.4
  6.31175-6.31225                  108-121.94                           2200-2300                          14.47-14.5
  8.291-8.294                      123-138                              2310-2390                          15.35-16.2
  8.362-8.366                      149.9-150.05                         2483.5-2500                        17.7-21.4
  8.37625-8.38675                  156.52475-156.52525                  2690-2900                          22.01-23.12
  8.41425-8.41475                  156.7-156.9                          3260-3267                          23.6-24.0
  12.29-12.293                     162.0125-167.17                      3332-3339                          31.2-31.8
  12.51975-12.52025                167.72-173.2                         3345.8-3358                        36.43-36.5
  12.57675-12.57725                240-285                              3600-4400                          --
  13.36-13.41                      322-335.4                            --                                 --
  Remark: only spurious emissions are allowed within these frequency bands not exceeding the limits per §15.209




CETECOM_TR18_1_0039001T03a


Test Report 18-1-0039001T03a, Page 16 of 26



5.4.4. Test condition and measurement test set-up
 EUT-grounding                                none          with power supply  additional connection
 Equipment set up                             table top 0.8m height                  floor standing
 Climatic conditions                         Temperature: (22±3°C)                   Rel. humidity: (40±20)%
 EMI-Receiver        Scan frequency range:    30 – 1000 MHz  other:
(Analyzer) Settings Scan-Mode                 6 dB EMI-Receiver Mode  3 dB spectrum analyser mode
                     Detector                Peak / Quasi-peak
                     RBW/VBW                 100 kHz/300 kHz
                     Mode:                   Repetitive-Scan, max-hold
                     Scan step               80 kHz
                     Sweep-Time              Coupled – calibrated display if continuous tx-signal otherwise adapted to EUT’s individual
                                             duty-cycle
 General measurement procedures              Please see chapter “Test system set-up for electric field measurement in the range 30 MHz
                                              to 1 GHz”



5.4.5. MEASUREMENT RESULTS
The results are presented below in summary form only. For more information please consult the diagrams included
in annex 1.

                                                      OP-
  Measurement
                       Frequency range                mode                       Remark                       Detector           Result
      No
                                                       no.

                                                                     Op. mode- worst case. Laying
        1             30 MHz - 960 MHz                   1                                                      Peak            passed
                                                                              position.

                                                                    Op. mode- worst case. Standing
        2             30 MHz - 960 MHz                   1                                                      Peak            passed
                                                                              position.




CETECOM_TR18_1_0039001T03a


Test Report 18-1-0039001T03a, Page 17 of 26

5.5. General Limit – Radiated field strength emissions, above 960 MHz
5.5.1. Test location and equipment
 Ref.-No.




                                 Equipment                                             Type                            Serial-No.


Frequency range 960 MHz – 18000 MHz
Measurement in FAR 2 with the distance between the EUT and the antenna 1 m
714    Spectrum Analyzer                                                 R&S FSU67                         104023
549    Antenna                                                           R&S HF907                         100334
338    RF Amplifier                                                      Miteq JS4-00102600-38-5P          838697
Measurement in FAR 2 with the distance between the EUT and the antenna 3 m
714    Spectrum Analyzer                                                 R&S FSU67                         104023
133    Antenna                                                           EMCO 3115                         9012-3629
-      RF Amplifier                                                      Wright Technologies ASG18B-4010   -
Frequency range 18000 MHz – 40000 MHZ
Measurement in FAR 2 with the distance between the EUT and the antenna 1 m
714    Spectrum Analyzer                                                 R&S FSU67                         104023
302    Antenna                                                           BBHA9170                          155
688    RF Amplifier                                                      Miteq JS-18004000-40-8P           1750117


5.5.2. Requirements/Limits
                              Part 15.517 5(c)
                FCC
                              Part 15.521 (h)
                              C63.4-2014
               ANSI
                              C63.10-2013
              Frequency
                                                                           Limits, EIRP in dBm
                [MHz]
              960-1610                                                            −75.3
              1610-1990                                                           −53.3
              1990-3100                                                           −51.3
             3100-10600                                                           −41.3
            10600- 40000                                                          −51.3

5.5.3. Measurement method:
Measurement method is described in general in chapter 4.4.
Due to the fact that limits especially in frequency range 960 MHz – 1990 MHz and 10600 MHz – 40 GHz are
very low, the measurement distance for these frequency ranges is reduced to 1m. The spectrum analyzer is
placed immediately after the receiving antenna. Preferably short RF cable is used for the connection of the
antenna and the spectrum analyzer.
                     Frequency range                                     Measurement distance
                           [MHz]                                                   [m]
                         960-1990                                                    1
                        1990-10600                                                   3
                       10600- 40000                                                  1

5.5.4. Test condition and measurement test set-up
 EUT-grounding                                none          with power supply  additional connection
 Equipment set up                             table top 1.5m height                 floor standing
 Climatic conditions                         Temperature: (22±3°C)                  Rel. humidity: (40±20)%
Spectrum- Scan frequency range:               1 – 18 GHz  18 – 25 GHz  18 – 40 GHz  other:
Analyzer     Scan-Mode                        6 dB EMI-Receiver Mode  3 dB Spectrum analyser Mode
settings     Detector                        RMS
             RBW/VBW                         1 MHz / 3 MHz
             Mode:                           Repetitive-Scan, max-hold
             Sweep-Time                      ≤ 1 ms over each measurement bin
General measurement procedures               Please see chapter “Test system set-up for radiated electric field measurements above 1 GHz”




CETECOM_TR18_1_0039001T03a


Test Report 18-1-0039001T03a, Page 18 of 26

5.5.5. Measurement Results

The results are presented below in summary form only. For more information please consult the diagrams
included in annex 1.

                                              OP-
  Measurement
                     Frequency range          mode            Remark              Detector     Result
      No
                                               no.

       1          960 MHz – 1610 MHz           1       Op. mode- worst case.       RMS         passed


       2          1610 MHz – 1990 MHz          1       Op. mode- worst case.       RMS         passed


       3          1990 MHz – 3100 MHz          1       Op. mode- worst case.       RMS         passed


       4          3100 MHz – 5500 MHz          1       Op. mode- worst case.       RMS         passed


       5          5500 MHz – 7250 MHz          1       Op. mode- worst case.       RMS         passed

                                                     Op. mode- worst case. RBW
                      fc=6480 MHz                     = 1 MHz. VBW= 3 MHz.
       6                                       1                                   RMS         passed
                      BW=600MHz                      BW = 600 MHz. SWT = 600
                                                     ms. MaxHold. Auto Sweep.

       7         7250 MHz – 10600 MHz          1       Op. mode- worst case.       RMS         passed


       8        10600 MHz – 15000 MHz          1       Op. mode- worst case.       RMS         passed


       9        15000 MHz – 18000 MHz          1       Op. mode- worst case.       RMS         passed


       10       18000 MHz – 40000 MHz          1       Op. mode- worst case.       RMS         passed

Remark : see diagrams in annex 1 for more details.




CETECOM_TR18_1_0039001T03a


Test Report 18-1-0039001T03a, Page 19 of 26

5.6. Radiated emissions in the GPS bands
5.6.1. Test location and equipment
 Ref.-No.




                                 Equipment                                             Type                              Serial-No.


Measurement in FAR 2 with the distance between the EUT and the antenna 3 m
714    Spectrum Analyzer                                                 R&S FSU67                           104023
133    Antenna                                                           EMCO 3115                           9012-3629
-      RF Amplifier                                                      Wright Technologies ASG18B-4010     -


5.6.2. Requirements/Limits
                 FCC          Part 15.517 5(d)
                              C63.4-2014
              ANSI
                              C63.10-2013
            Frequency
                                                                           Limits, EIRP in dBm
              [MHz]
            1164-1240                                                             -85.3
            1559-1610                                                             -85.3

5.6.3. Test condition and measurement test set-up
 EUT-grounding                                none          with power supply  additional connection
 Equipment set up                             table top 1.5m height                 floor standing
 Climatic conditions                         Temperature: (22±3°C)                  Rel. humidity: (40±20)%
Spectrum- Scan-Mode                           6 dB EMI-Receiver Mode  3 dB Spectrum analyser Mode
Analyzer     Detector                        RMS
settings     RBW/VBW                         1 kHz / 3 kHz
             Mode:                           Repetitive-Scan, max-hold
             Sweep-Time                      ≤ 1 ms over each measurement bin
General measurement procedures               Please see chapter “Test system set-up for radiated electric field measurements above 1 GHz”



5.6.4. Measurement Results
The results are presented below in summary form only. For more information please consult the diagrams
included in annex 1.

                                                        OP-
  Measurement
                          Frequency range               mode                    Remark                     Detector         Result
      No
                                                         no.

             1               1164-1240                     1           Op. mode- worst case.                RMS             passed


             2               1559-1610                     1           Op. mode- worst case.                RMS             passed

Remark : see diagrams in annex 1 for more details.




CETECOM_TR18_1_0039001T03a


Test Report 18-1-0039001T03a, Page 20 of 26

5.7. Fundamental emission peak power
5.7.1. Test location and equipment FAR
 Ref.-No.




                                 Equipment                                             Type                                 Serial-No.


Measurement in FAR 2 with the distance between the EUT and the antenna 3 m
714    Spectrum Analyzer                                                 R&S FSU67                             104023
133    Antenna                                                           EMCO 3115                             9012-3629
-      RF Amplifier                                                      Wright Technologies ASG18B-4010       -


5.7.2. Requirements/Limits
                               FCC                                      Part 15.517 5(e)

                                                                        C63.4-2014
                               ANSI
                                                                        C63.10-2013
                            Frequency
                                                                                                Limits, EIRP in dBm
                              [MHz]
        Frequency with the highest radiated emission
       contained within a 50 MHz bandwidth from the                                                        0
         measurement according to FCC 15.517 5(c)

5.7.3. Test condition and measurement test set-up
 EUT-grounding                                 none          with power supply  additional connection
 Equipment set up                              table top 1.5m height                 floor standing
 Climatic conditions                          Temperature: (22±3°C)                  Rel. humidity: (40±20)%
Spectrum- Scan-Mode                            6 dB EMI-Receiver Mode  3 dB Spectrum analyser Mode
Analyzer     Detector                         MaxPeak
settings     RBW/VBW                          50 MHz / 80 MHz
             Mode:                            Repetitive-Scan, max-hold
             Sweep-Time                       ≤ 1 ms over each measurement bin
General measurement procedures                Please see chapter “Test system set-up for radiated electric field measurements above 1 GHz”



5.7.4. Measurement Results
The results are presented below in summary form only. For more information please consult the diagrams
included in annex 1.

                                                              OP-
  Measurement                                      Pmax,
                    fc, [MHz] fmax, [MHz]                     mode                          Remark                         Detector      Result
      No                                          [dBm]
                                                               No

            1          6480          6487.5        -6.55         1                Op. mode- worst case.                     RMS          passed

Remark: frequency with the highest radiated emission contained within a 50 MHz bandwidth from the
measurement according to FCC 15.517 5(c) is the frequency inside of the fundamental emission.

5.8. Antenna requirement according to FCC 15.203
The antenna is permanently affixed to the module.




CETECOM_TR18_1_0039001T03a


Test Report 18-1-0039001T03a, Page 21 of 26

5.9. Measurement uncertainties

The reported uncertainties are calculated based on the standard uncertainty multiplied with the appropriate
coverage factor k, such that a confidence level of approximately 95% is achieved.
For uncertainty determination, each component used in the concrete measurement set-up was taken in account and
it’s contribution to the overall uncertainty according it’s statistical distribution calculated.

Following table shows expectable uncertainties for each measurement type performed.

                                                                       Calculated uncertainty based on a
     RF-Measurement           Reference         Frequency range                                                      Remarks
                                                                           confidence level of 95%
 Conducted emissions                      9 kHz - 150 kHz          4.0 dB
                             CISPR 16-2-1                                                                               -
 (U CISPR)                                150 kHz - 30 MHz         3.6 dB
 Radiated emissions                       30 MHz - 1 GHz           4.2 dB
                             CISPR 16-2-3                                                                            E-Field
 Enclosure                                1 GHz - 18 GHz           5.1 dB
 Disturbance power           CISPR 16-2-2 30 MHz - 300 MHz         -                                                    -
                                                                                                                Substitution
 Power Output radiated            -           30 MHz - 4 GHz       3.17 dB
                                                                                                                method
                                                                   Cel- Cel-
                                              Set-up No.                         BT1     W1     W2         --
                                                                    C1     C2
 Power Output conducted           -           9 kHz - 12.75 GHz    N/A 0.60       0.7   0.25   N/A         --           -
                                              12.75 - 26.5GHz      N/A 0.82        --   N/A    N/A         --
 Conducted emissions              -           9 kHz - 2.8 GHz      0.70 N/A      0.70   N/A    0.69        --    N/A - not
 on RF-port                                   2.8 GHz - 12.75GHz   1.48 N/A      1.51   N/A    1.43        --    applicable
                                              12.75 GHz - 18GHz    1.81 N/A      1.83   N/A    1.77        --
                                              18 GHz - 26.5GHz     1.83 N/A      1.85   N/A    1.79        --
 Power density                    -           1 – 2.8GHz           1.40 dB                                      --
                                                                   0.1272 ppm (Delta Marker)                    Frequency
 Occupied bandwidth               -           9 kHz - 4 GHz                                                     error
                                                                   1.0 dB                                       Power
                                  -                                0.1272 ppm (Delta Marker)                    Frequency
 Emission bandwidth                           9 kHz - 4 GHz                                                     error
                                  -                                See above: 0.70 dB                           Power
 Frequency stability              -           9 kHz - 20 GHz       0.0636 ppm                                         -
                                              150 kHz - 30 MHz     5.0 dB                                       Magnetic
 Radiated emissions                           30 MHz - 1 GHz       4.2 dB                                       field
                                  -
 Enclosure                                    1 GHz - 20 GHz       3.17 dB                                      E-field
                                                                                                                Substitution
Table: measurement uncertainties, valid for conducted/radiated measurements




CETECOM_TR18_1_0039001T03a


Test Report 18-1-0039001T03a, Page 22 of 26


6. Abbreviations used in this report
 The abbreviations
 ANSI                    American National Standards Institute
 AV , AVG, CAV           Average detector
 EIRP                    Equivalent isotropically radiated power, determined within a separate measurement
 EGPRS                   Enhanced General Packet Radio Service
 EUT                     Equipment Under Test
 FCC                     Federal Communications Commission, USA
 IC                      Industry Canada
 n.a.                    not applicable
 Op-Mode                 Operating mode of the equipment
 PK                      Peak
 RBW                     resolution bandwidth
 RF                      Radio frequency
 RSS                     Radio Standards Specification, Dokuments from Industry Canada
 Rx                      Receiver
 TCH                     Traffic channel
 Tx                      Transmitter
 QP                      Quasi peak detector
 VBW                     Video bandwidth
 ERP                     Effective radiated power



7. Accreditation details of CETECOM’s laboratories and test sites

 Ref.-   Accreditation                  Valid for laboratory area or test site
 No.      Certificate                                                                               Accreditation Body
 -          D-PL-                                                                             DAkkS, Deutsche
                         All laboratories and test sites of CETECOM GmbH, Essen
         12047-01-01                                                                          Akkreditierungsstelle GmbH
 337                 Radiated Measurements 30 MHz to 1 GHz, 3 m / 10 m (OATS)
 487                 Radiated Measurements 30 MHz to 1 GHz, 3 m (SAR)                         FCC, Federal Communications
      (MRA US-EU
 558                 Radiated Measurements above 1 GHz, 3 m (FAR)                             Commission
          0003)
 348                 Mains Ports Conducted Interference Measurements                          Laboratory Division, USA
 348                 Telecommunication Ports Conducted Interference Measurem.
 337        --       Radiated Measurements 30 MHz to 1 GHz, 3 m / 10 m (OATS)
                                                                                              ISED, Industry Canada
 487    3462D-2      Radiated Measurements 30 MHz to 1 GHz, 3 m (SAR)
                                                                                              Certification and Engineering
 550    3462D-2      Radiated Measurements 1 GHz to 6 GHz, 3 m (SAR)
                                                                                              Bureau
 558    3462D-3      Radiated Measurements above 1 GHz, 3 m (FAR)
 487     R- 4452     Radiated Measurements 30 MHz to 1 GHz, 3 m (SAR)
                                                                                              VCCI, Voluntary Control Council
 550    G- 20013     Radiated Measurements 1 GHz to 6 GHz, 3 m (SAR)
                                                                                              for Interference by Information
 348    C- 20009     Mains Ports Conducted Interference Measurements
                                                                                              Technology Equipment, Japan
 348    T- 20006     Telecommunication Ports Conducted Interference Measurem.
 OATS = Open Area Test Site, SAR = Semi Anechoic Room, FAR = Fully Anechoic Room




CETECOM_TR18_1_0039001T03a


Test Report 18-1-0039001T03a, Page 23 of 26


8. Instruments and Ancillary
8.1. Used equiment “CTC”
The “Ref.-No” in the left column of the following tables allows the clear identification of the laboratory
equipment.


8.1.1. Test software and firmware of equipment
  Ref.-No.




                            Equipment                            Type                  Serial-No.       Version of Firmware or Software during the test


001          EMI Test Receiver                         ESS                      825132/017          Firm.= 1.21 , OTP=2.0, GRA=2.0
012          Signal Generator (EMS-cond.)              SMY 01                   839069/027          Firm.= V 2.02
013          Power Meter (EMS cond.)                   NRVD                     839111/003          Firm.= V 1.51
017          Digital Radiocommunication Tester         CMD 60 M                 844365/014          Firmware = V 3.52 .22.01.99, DECT = D2.87 13.01.99
053          Audio Analyzer                            UPA3                     860612/022          Firm. V 4.3
119          RT Harmonics Analyzer dig. Flickermeter   B10                      G60547              Firm.= V 3.1DHG
140          Signal Generator                          SMHU                     831314/006          Firm.= 3.21
261          Thermal Power Sensor                      NRV-Z55                  825083/0008         EPROM-Datum 02.12.04, SE EE 1 B
262          Power Meter                               NRV-S                    825770/0010         Firm.= 2.6
263          Signal Generator                          SMP 04                   826190/0007         Firm.=3.21
                                                                                                    UNIT Firmware= 4.04, SW-Main=4.04, SW-BBP=1.04,
295          Racal Digital Radio Test Set              6103                     1572
                                                                                                    SW-DSP=1.02, Hardboot=1.02, Softboot=2.02
                                                                                                    R&S Test Firmware =3.53 /3.54 (current Testsoftw. f.
298          Univ. Radio Communication Tester          CMU 200                  832221/091
                                                                                                    all band used
323          Digital Radiocommunication Tester         CMD 55                   825878/0034         Firm.= 3.52 .22.01.99
335          CTC-EMS-Conducted                         System EMS Conducted     -                   EMC 32 V 8.52
340          Digital Radiocommunication Tester         CMD 55                   849709/037          Firm.= 3.52 .22.01.99
355          Power Meter                               URV 5                    891310/027          Firm.= 1.31
365          10V Insertion Unit 50 Ohm                 URV5-Z2                  100880              Eprom Data = 31.03.08
366          Ultra Compact Simulator                   UCS 500 M4               V0531100594         Firm. UCS 500=001925/3.06a02, rc=ISMIEC 4.10
371          Bluetooth Tester                          CBT32                    100153              CBT V5,30+ SW-Option K55, K57
377          EMI Test Receiver                         ESCS 30                  100160              Firm.= 2.30, OTP= 02.01, GRA= 02.36
378          Broadband RF Field Monitor                RadiSense III            03D00013SNO-08      Firm.= V.03D13
389          Digital Multimeter                        Keithley 2000            0583926             Firm. = A13 (Mainboard) A02 (Display)
                                                                                                    Firm.= 4.50 #005, IPL=4.01#001,OS=4.02#001,
392          Radio Communication Tester                MT8820A                  6K00000788          GSM=4.41#013, W-CDMA= 4.54#004, scenario=
                                                                                                    4.52#002
                                                                                                    R&S Test Firmware Base=5.14, Mess-Software=
436          Univ. Radio Communication Tester          CMU 200                  103083
                                                                                                    GSM:5.14 WCDMA:5.14 (current Testsoftw. F. all band
441          CTC-SAR-EMI Cable Loss                    System EMI field (SAR)   -                   EMC 32 Version 8.52
442          CTC-SAR-EMS                               System EMS field (SAR)   -                   EMC 32 Version 8.40
                                                       System CTC-FAR-EMI-
443          CTC-FAR-EMI-RSE                                                    -                   Spuri 7.2.5 or EMC 32 Ver. 9.15.00
                                                       RSE
444          CTC-FAR-EMS field                         System-EMS-Field (FAR)   -                   EMC 32 Version 9.15.00
                                                                                                    R&S Test Firmware Base=5.14, GSM=5.14
460          Univ. Radio Communication Tester          CMU 200                  108901
                                                                                                    WCDMA=5.14 (current Testsoftw.,f. all band to be used,
489          EMI Test Receiver                         ESU40                    1000-30             Firmware=4.43 SP3, Bios=V5.1-16-3, Spec. =01.00
491          ESD Simulator dito                        ESD dito                 dito307022          V 2.30
524          Voltage Drop Simulator                    VDS 200                  0196-16             Software Nr: 000037 Version V4.20a01
526          Burst Generator                           EFT 200 A                0496-06             Software Nr. 000034 Version V2.32
527          Micro Pulse Generator                     MPG 200 B                0496-05             Software-Nr. 000030 Version V2.43
528          Load Dump Simulator                       LD 200B                  0496-06             Software-Nr. 000031 Version V2.35a01
                                                                                                    R&S Test Firmware Base=5.14, GSM=5.14
546          Univ. Radio Communication Tester          CMU 200                  106436
                                                                                                    WCDMA=5.14 (current Testsoftw.,f. all band to be used
                                                                                                    R&S Test Firmware Base=V5.1403 (current Testsoftw.,
547          Univ. Radio Communication Tester          CMU 200                  835390/014
                                                                                                    f. all band used, GSM = 5.14 WCDMA: = 5.14
584          Spectrum Analyzer                         FSU 8                    100248              2.82_SP3
                                                                                                    R&S Test Firmware Base=5.01, GSM=5.02 WCDMA=
597          Univ. Radio Communication Tester          CMU 200                  100347
                                                                                                    not installed, Mainboard= µP1=V.850
598          Spectrum Analyzer                         FSEM 30                  831259/013          Firmware Bios 3.40 , Analyzer 3.40 Sp 2
607          Signal Generator                          SMR 20                   832033/011          V1.25
620          EMI Test Receiver                         ESU 26                   100362              4.43_SP3
642          Wideband Radio Communication Tester       CMW 500                  126089              Setup V03.26, Test programm component V03.02.20
670          Univ. Radio Communication Tester          CMU 200                  106833              µP1 =V8.50, Firmware = V.20
689          Vector Signal Generator                   SMU200                   100970              02.20.360.142
                                                                                                    CBT V 5.40, FW: V.2.41 (FPGA Digital, V. 3.09 FPGA
692          Bluetooth Tester                          CBT 32                   100236
                                                                                                    RF)




CETECOM_TR18_1_0039001T03a


Test Report 18-1-0039001T03a, Page 24 of 26



8.1.2. Single instruments and test systems
 Ref.-No.




                                                                                                                              calibration
                                                                                                                              Interval of



                                                                                                                                                Remark
                           Equipment                             Type               Serial-No.             Manufacturer                                      Cal
                                                                                                                                                             due

001         EMI Test Receiver                         ESS                     825132/017              Rohde & Schwarz         12 M          -            16.05.2018
005         AC - LISN (50 Ohm/50µH, test site 1)      ESH2-Z5                 861741/005              Rohde & Schwarz         12 M          -            15.05.2018
007         Single-Line V-Network (50 Ohm/5µH)        ESH3-Z6                 892563/002              Rohde & Schwarz         12 M          -            17.05.2018
009         Power Meter (EMS-radiated)                NRV                     863056/017              Rohde & Schwarz         24 M          -            15.05.2019
016         Line Impedance Simulating Network         Op. 24-D                B6366                   Spitzenberger+Spies     36 M          -            30.05.2019
021         Loop Antenna (H-Field)                    6502                    9206-2770               EMCO                    36 M          -            30.04.2018
030         Loop Antenna (H-field)                    HFH-Z2                  879604/026              Rohde & Schwarz         36 M          -            30.04.2018
033         RF-current probe (100kHz-30MHz)           ESH2-Z1                 879581/18               Rohde & Schwarz         24 M          -            15.05.2019
057         relay-switch-unit (EMS system)            RSU                     494440/002              Rohde & Schwarz         pre-m         1a
060         power amplifier (DC-2kHz)                 PAS 5000                B6363                   Spitzenberger+Spies     -             3
086         DC - power supply, 0 -10 A                LNG 50-10               -                       Heinzinger Electronic   pre-m         2
087         DC - power supply, 0 -5 A                 EA-3013 S               -                       Elektro Automatik       pre-m         2
091         USB-LWL-Converter                         OLS-1                   007/2006                Ing. Büro Scheiba       -             4
099         passive voltage probe                     ESH2-Z3                 299.7810.52             Rohde & Schwarz         36 M          -            30.04.2018
100         passive voltage probe                     Probe TK 9416           without                 Schwarzbeck             36 M          -            30.04.2018
110         USB-LWL-Converter                         OLS-1                   -                       Ing. Büro Scheiba       -             4
119         RT Harmonics Analyzer dig. Flickermeter   B10                     G60547                  BOCONSULT               36 M          -            30.05.2019
133         horn antenna 18 GHz (Meas 1)              3115                    9012-3629               EMCO                    36 M          1c           10.03.2020
134         horn antenna 18 GHz (Subst 2)             3115                    9005-3414               EMCO                    36 M          -            10.03.2020
136         adjustable dipole antenna (Dipole 1)      3121C-DB4               9105-0697               EMCO                    36 M          -            30.04.2018
140         Signal Generator                          SMHU                    831314/006              Rohde & Schwarz         24 M          -            30.05.2018
248         attenuator                                SMA 6dB 2W              -                       Radiall                 pre-m         2
249         attenuator                                SMA 10dB 10W            -                       Radiall                 pre-m         2
252         attenuator                                N 6dB 12W               -                       Radiall                 pre-m         2
256         attenuator                                SMA 3dB 2W              -                       Radiall                 pre-m         2
257         hybrid                                    4031C                   04491                   Narda                   pre-m         2
260         hybrid coupler                            4032C                   11342                   Narda                   pre-m         2
261         Thermal Power Sensor                      NRV-Z55                 825083/0008             Rohde & Schwarz         24 M          -            30.05.2018
262         Power Meter                               NRV-S                   825770/0010             Rohde & Schwarz         24 M          -            30.05.2018
263         Signal Generator                          SMP 04                  826190/0007             Rohde & Schwarz         36 M          -            30.05.2019
265         peak power sensor                         NRV-Z33, Model 04       840414/009              Rohde & Schwarz         24 M          -            30.05.2018
266         Peak Power Sensor                         NRV-Z31, Model 04       843383/016              Rohde & Schwarz         24 M          -            30.05.2018
267         notch filter GSM 850                      WRCA 800/960-6EEK       9                       Wainwright GmbH         pre-m         2
270         termination                               1418 N                  BB6935                  Weinschel               pre-m         2
271         termination                               1418 N                  BE6384                  Weinschel               pre-m         2
272         attenuator (20 dB) 50 W                   Model 47                BF6239                  Weinschel               pre-m         2
273         attenuator (10 dB) 100 W                  Model 48                BF9229                  Weinschel               pre-m         2
274         attenuator (10 dB) 50 W                   Model 47 (10 dB) 50 W   BG0321                  Weinschel               pre-m         2
275         DC-Band                                   Model 7003 (N)          C5129                   Weinschel               pre-m         2
276         DC-Band                                   Model 7006 (SMA)        C7061                   Weinschel               pre-m         2
279         power divider                             1515 (SMA)              LH855                   Weinschel               pre-m         2
298         Univ. Radio Communication Tester          CMU 200                 832221/091              Rohde & Schwarz         pre-m         3
300         AC LISN (50 Ohm/50µH, 1-phase)            ESH3-Z5                 892 239/020             Rohde & Schwarz         12 M          -            17.05.2018
301         attenuator (20 dB) 50W, 18GHz             47-20-33                AW0272                  Lucas Weinschel         pre-m         2
302         horn antenna 40 GHz (Meas 1)              BBHA9170                155                     Schwarzbeck             36 M          -            14.03.2020
303         horn antenna 40 GHz (Subst 1)             BBHA9170                156                     Schwarzbeck             36 M          -            20.03.2020
331         Climatic Test Chamber -40/+180 Grad       HC 4055                 43146                   Heraeus Vötsch          24 M          -            30.10.2018
341         Digital Multimeter                        Fluke 112               81650455                Fluke                   24 M          -            30.05.2018
342         Digital Multimeter                        Voltcraft M-4660A       IB 255466               Voltcraft               24 M          -            17.05.2019
347         laboratory site                           radio lab.              -                       -                       -             5
348         laboratory site                           EMI conducted           -                       -                       -             5
354         DC - Power Supply 40A                     NGPE 40/40              448                     Rohde & Schwarz         pre-m         2
355         Power Meter                               URV 5                   891310/027              Rohde & Schwarz         24 M          -            30.05.2018
357         power sensor                              NRV-Z1                  861761/002              Rohde & Schwarz         24 M          -            24.05.2019
371         Bluetooth Tester                          CBT32                   100153                  R&S                     36 M          -            30.05.2019
373         Single-Line V-Network (50 Ohm/5µH)        ESH3-Z6                 100535                  Rohde & Schwarz         12 M          -            17.05.2018
377         EMI Test Receiver                         ESCS 30                 100160                  Rohde & Schwarz         12 M          -            15.05.2018
392         Radio Communication Tester                MT8820A                 6K00000788              Anritsu                 12 M          -            18.05.2018
                                                                              126.0604.0003.3.3.3.2   LUFFT Mess u.
405         Thermo-/Hygrometer                        OPUS 10 THI                                                             24 M          -            30.03.2019
                                                                              2                       Regeltechnik
431         Model 7405                                Near-Field Probe Set    9305-2457               EMCO                    -             4
436         Univ. Radio Communication Tester          CMU 200                 103083                  Rohde & Schwarz         12 M          -            24.05.2018
439         UltraLog-Antenna                          HL 562                  100248                  Rohde & Schwarz         36 M          -            10.03.2020
454         Oscilloscope                              HM 205-3                9210 P 29661            Hameg                   -             4
456         DC-Power supply 0-5 A                     EA 3013 S               207810                  Elektro Automatik       pre-m         2
459         DC -Power supply 0-5 A , 0-32 V           EA-PS 2032-50           910722                  Elektro Automatik       pre-m         2
460         Univ. Radio Communication Tester          CMU 200                 108901                  Rohde & Schwarz         12 M          -            16.06.2018
463         Universal source                          HP3245A                 2831A03472              Agilent                 -             4
466         Digital Multimeter                        Fluke 112               89210157                Fluke USA               24 M          -            30.05.2018


CETECOM_TR18_1_0039001T03a


Test Report 18-1-0039001T03a, Page 25 of 26
 Ref.-No.




                                                                                                                                   calibration
                                                                                                                                   Interval of



                                                                                                                                                     Remark
                             Equipment                           Type                    Serial-No.             Manufacturer                                      Cal
                                                                                                                                                                  due

467         Digital Multimeter                        Fluke 112                   89680306                Fluke USA                36 M          -            30.04.2018
468         Digital Multimeter                        Fluke 112                   90090455                Fluke USA                36 M          -            30.04.2018
477         ReRadiating GPS-System                    AS-47                       -                       Automotive Cons. Fink    -             3
480         power meter (Fula)                        NRVS                        838392/031              Rohde & Schwarz          24 M          -            16.05.2019
482         filter matrix                             Filter matrix SAR 1         -                       CETECOM (Brl)            -             1d
                                                      System EMI field (SAR)                              ETS Lindgren /
487         System CTC NSA-Verification SAR-EMI                                   -                                                24 M          -            31.03.2019
                                                      NSA                                                 CETECOM
489         EMI Test Receiver                         ESU40                       1000-30                 Rohde & Schwarz          12 M          -            18.05.2019
                                                      WRCG 1709/1786-
502         band reject filter                                                    SN 9                    Wainwright               pre-m         2
                                                      1699/1796-
503         band reject filter                        WRCG 824/849-814/859-       SN 5                    Wainwright               pre-m         2
517         relais switch matrix                      HF Relais Box Keithley      SE 04                   Keithley                 pre-m         2
523         Digital Multimeter                        L4411A                      MY46000154              Agilent                  24 M          -            18.05.2019
529         6 dB Broadband resistive power divider    Model 1515                  LH 855                  Weinschel                pre-m         2
530         10 dB Broadband resistive power divider   R 416110000                 LOT 9828                -                        pre-m         2
546         Univ. Radio Communication Tester          CMU 200                     106436                  R&S                      12 M          -            30.03.2018
547         Univ. Radio Communication Tester          CMU 200                     835390/014              Rohde & Schwarz          12 M          -            05.07.2018
549         Log.Per-Antenna                           HL025                       1000060                 Rohde & Schwarz          36/12 M       -            31.07.2018
            System CTC S-VSWR Verification SAR-       System EMI Field SAR S-                             ETS
550                                                                               -                                                24 M          -            30.03.2019
            EMI                                       VSWR                                                Lindgren/CETECOM
557         System CTC-OTA-2                          R&S TS8991                  -                       Rohde & Schwarz          12 M          5            30.09.2016
                                                      System CTC FAR S-
558         System CTC FAR S-VSWR                                                 -                       CTC                      24 M          -            08.08.2019
                                                      VSWR
574         Biconilog Hybrid Antenna                  BTA-L                       980026L                 Frankonia                36/12 M       -            31.03.2019
584         Spectrum Analyzer                         FSU 8                       100248                  Rohde & Schwarz          pre-m         -
597         Univ. Radio Communication Tester          CMU 200                     100347                  Rohde & Schwarz          pre-m         -
600         power meter                               NRVD (Reserve)              834501/018              Rohde & Schwarz          24 M          -            17.05.2019
601         medium-sensitivity diode sensor           NRV-Z5 (Reserve)            8435323/003             Rohde & Schwarz          24 M          -            15.05.2019
602         peak power sensor                         NRV-Z32 (Reserve)           835080                  Rohde & Schwarz          24 M          -
611         DC power supply                           E3632A                      KR 75305854             Agilent                  pre-m         2
612         DC power supply                           E3632A                      MY 40001321             Agilent                  pre-m         2
613         Attenuator                                R416120000 20dB 10W         Lot. 9828               Radiall                  pre-m         2
616         Digitalmultimeter                         Fluke 177                   88900339                Fluke                    24 M          -            30.05.2018
617         Power Splitter/Combiner                   ZFSC-2-2-S+                 S F987001108            Mini Circuits            -             2
618         Power Splitter/Combiner                   50PD-634                    600994                  JFW Industries USA       -             2
619         Power Splitter/Combiner                   50PD-634                    600995                  JFW Industries, USA      -             3
620         EMI Test Receiver                         ESU 26                      100362                  Rohde-Schwarz            12 M          -            16.05.2018
621         Step Attenuator 0-139 dB                  RSP                         100017                  Rohde & Schwarz          pre-m         2
625         Generic Test Load USB                     Generic Test Load USB       -                       CETECOM                  -             2
                                                                                  201.0999.9302.6.4.1.4
627         data logger                               OPUS 1                                              G. Lufft GmbH            24 M          -            30.03.2019
                                                                                  3
634         Spectrum Analyzer                         FSM (HF-Unit)               826188/010              Rohde & Schwarz          pre-m         2
                                                      HDMI cable with Ethernet
637         High Speed HDMI with Ethernet 1m                                      -                       KogiLink                 -             2
                                                      1m
638         HDMI Kabel with Ethernet 1,5 m flach      HDMI cable with Ethernet    -                       Reichelt                 -             2
640         HDMI cable 2m rund                        HDMI cable 2m rund          -                       Reichelt                 -             2
641         HDMI cable with Ethernet                  Certified HDMI cable with   -                       PureLink                 -             2
642         Wideband Radio Communication Tester       CMW 500                     126089                  Rohde&Schwarz            12 M          -            24.05.2018
644         Amplifierer                               ZX60-2534M+                 SN865701299             Mini-Circuits            -             -
670         Univ. Radio Communication Tester          CMU 200                     106833                  Rohde & Schwarz          24 M          -            30.05.2018
671         DC-power supply 0-5 A                     EA-3013S                    -                       Elektro Automatik        pre-m         2
678         Power Meter                               NRP                         101638                  Rohde&Schwarz            pre-m         -
683         Spectrum Analyzer                         FSU 26                      200571                  Rohde & Schwarz          12 M          -            17.05.2018
                                                                                                          Narda Safety Test
686         Field Analyzer                            EHP-200A                    160WX30702                                       24 M          -            29.03.2019
                                                                                                          Solutions
687         Signal Generator                          SMF 100A                    102073                  Rohde&Schwarz            12 M          -            17.05.2018
688         Pre Amp                                   JS-18004000-40-8P           1750117                 Miteq                    pre-m         -
690         Spectrum Analyzer                         FSU                         100302/026              Rohde&Schwarz            12 M          -            16.05.2018
691         OSP120 Base Unit                          OSP120                      101183                  Rohde & Schwarz          12 M          -            22.05.2018
692         Bluetooth Tester                          CBT 32                      100236                  Rohde & Schwarz          36 M          -            29.05.2020
697         Power Splitter                            ZN4PD-642W-S+               165001445               Mini-Circuits            -             2
                                                      MA 4010-KT080-XPET-         MA4170-KT100-
703         INNCO Antennen Mast                                                                           INNCO                    pre-m         -
                                                      ZSS3                        XPET-
                                                                                  CO3000/933/3841051
704         INNCON Controller                         CO 3000-4port                                       INNCO Systems GmBh       pre-m         -
                                                                                  6/L
711         Harmonic Mixer 90 GHz - 140GHz            RPG FS-Z140                 101004                  RPG                      12 M          -            22.02.2018
712         Harmonic Mixer 75 GHz - 110GHz            FS-Z110                     101468                  Rohde & Schwarz          12 M          -            22.02.2018
713         Harmonic Mixer, 50 GHz - 75GHz            FS-Z75                      101022                  Rohde & Schwarz          12 M          -            22.05.2018
714         Signal Analyzer 67GHz                     FSW67                       104023                  Rohde & Schwarz          24 M          -            03.03.2019
                                                                                                          RPG Radiometer
715         Harmonic Mixer, 140 GHz - 220GHz          FS-Z220                     101009                                           12 M          -            03.08.2018
                                                                                                          Physics
716         Harmonic Mixer 220 GHz to 325 GHZ         FS-Z325                     101005                  RPG Radiometer Physics   12 M          -            13.02.2018
747         Spectrum Analyzer                         FSU 26                      200152                  Rohde & Schwarz          12 M          -            18.05.2018



CETECOM_TR18_1_0039001T03a


Test Report 18-1-0039001T03a, Page 26 of 26
 Ref.-No.




                                                                                                                                        calibration
                                                                                                                                        Interval of



                                                                                                                                                          Remark
                          Equipment                             Type                    Serial-No.               Manufacturer                                          Cal
                                                                                                                                                                       due

748         Pickett-Potter Horn Antenna              FH-PP 4060                   010001                   Radiometer Physiscs          -             -
749         Pickett-potter Horn Antenna              FH-PP 60-90                  010003                   Radiometer Physics           -             -
750         Pickett-Potter Horn Antenna              FH-PP 140-220                010011                   Radiometer Physics           -             -
757         CMW500 wide. Radio Comm.                 CMW500                       158150                   Rohde & Schwarz              12 M          -            01.05.2017




8.1.3. Legend

Note / remarks                            Calibrated during system calibration:
                               1a         System CTC-SAR-EMS (Ref.-No. 442)
                               1b         System-CTC-EMS-Conducted (Ref.-No. 335)
                               1c         System CTC-FAR-EMI-RSE (Ref.-No . 443)
                               1d         System CTC-SAR-EMI (Ref.-No . 441)
                               1e         System CTC-OATS (EMI radiated) (Ref.-No. 337)
                               1f         System CTC-CTIA-OTA (Ref.-No . 420)
                               1g         System CTC-FAR-EMS (Ref.-No . 444)
                               2          Calibration or equipment check immediately before measurement
                               3          Regulatory maintained equipment for functional check or support purpose
                               4          calibration of this equipment
                                          Ancillary equipment    without has no effect
                                                                         calibration   onmechanical
                                                                                     e.g. measuring result
                                                                                                    equipment or monitoring equipment
                               5          Test System


Interval of calibration        12 M       12 month
                               24 M       24 month
                               36 M       36 month
                               24/12 M    Calibration every 24 months, between this every 12 months internal validation
                               36/12 M    Calibration every 36 months, between this every 12 months internal validation
                               Pre-m      Check before starting the measurement
                               -          Without calibration




9. Versions of test reports (change history)

            Version           Applied changes                                                                                       Date of release
              --              Initial release                                                                                        2018-09-14
              --              --                                                                                                          --
              --              --                                                                                                          --




CETECOM_TR18_1_0039001T03a



Document Created: 2018-09-17 13:24:39
Document Modified: 2018-09-17 13:24:39

© 2025 FCC.report
This site is not affiliated with or endorsed by the FCC