RF Exposure Report

FCC ID: 2AIZN-X606D

RF Exposure Info

Download: PDF
FCCID_3872911

RF EXPOSURE
REPORT

Report No.: 18070496-FCC-H
Supersede Report No.: N/A
Applicant          INFINIX MOBILITY LIMITED
Product Name       Mobile phone
Model No.          X606D
Serial No.         N/A
Test Standard      FCC 2.1093
Test Date          May 11 to 22, 2018
Issue Date         May 23, 2018
Test Result            Pass       Fail
Equipment complied with the specification
Equipment did not comply with the specification




        Aaron Liang                      David Huang
       Test Engineer                     Checked By

                      This test report may be reproduced in full only
     Test result presented in this test report is applicable to the tested sample only


                                          Issued by:
                    SIEMIC (SHENZHEN-CHINA) LABORATORIES
                   Zone A, Floor 1, Building 2 Wan Ye Long Technology Park
       South Side of Zhoushi Road, Bao’ an District, Shenzhen, Guangdong China 518108
                 Phone: +86 0755 2601 4629801 Email: China@siemic.com.cn


                                          Test Report       18070496-FCC-H
                                          Page
                                          No.               2 of 9




                             Laboratories Introduction

SIEMIC, headquartered in the heart of Silicon Valley, with superior facilities in US and Asia, is one
of the leading independent testing and certification facilities providing customers with one-stop
shop services for Compliance Testing and Global Certifications.




In addition to testing and certification, SIEMIC provides initial design reviews and compliance
management throughout a project. Our extensive experience with China, Asia Pacific, North
America, European, and International compliance requirements, assures the fastest, most cost
effective way to attain regulatory compliance for the global markets.


                       Accreditations for Conformity Assessment
            Country/Region                                           Scope
                   USA                            EMC, RF/Wireless, SAR, Telecom
                 Canada                           EMC, RF/Wireless, SAR, Telecom
                  Taiwan                           EMC, RF, Telecom, SAR, Safety
               Hong Kong                                RF/Wireless, SAR, Telecom
                 Australia                         EMC, RF, Telecom, SAR, Safety
                  Korea                          EMI, EMS, RF, SAR, Telecom, Safety
                  Japan                            EMI, RF/Wireless, SAR, Telecom
                Singapore                                EMC, RF, SAR, Telecom
                  Europe                           EMC, RF, SAR, Telecom, Safety


                                      Test Report   18070496-FCC-H
                                      Page
                                      No.           3 of 9




This page has been left blank intentionally.


                                                                      Test Report                18070496-FCC-H
                                                                      Page
                                                                      No.                        4 of 9




CONTENTS

1.     REPORT REVISION HISTORY.............................................................................................................................5

2.     CUSTOMER INFORMATION ................................................................................................................................5

3.     TEST SITE INFORMATION ...................................................................................................................................5

4.     EQUIPMENT UNDER TEST (EUT) INFORMATION .........................................................................................6

5.     FCC §2.1093 - RADIOFREQUENCY RADIATION EXPOSURE EVALUATION: PORTABLE DEVICES. 8

5.1 RF EXPOSURE..........................................................................................................................................................8

5.2 TEST RESULT ...........................................................................................................................................................9


                                             Test Report   18070496-FCC-H
                                             Page
                                             No.           5 of 9




1. Report Revision History

         Report No.             Report Version             Description                Issue Date
      18070496-FCC-H                  NONE                   Original                 May 23, 2018




2. Customer information


Applicant Name          INFINIX MOBILITY LIMITED
Applicant Add           RMS 05-15, 13A/F SOUTH TOWER WORLD FINANCE CTR HARBOUR CITY 17
                        CANTON RD TST KLN HONG KONG
Manufacturer            INFINIX MOBILITY LIMITED
Manufacturer Add        RMS 05-15, 13A/F SOUTH TOWER WORLD FINANCE CTR HARBOUR CITY 17
                        CANTON RD TST KLN HONG KONG



3. Test site information
 Lab performing tests       SIEMIC (Shenzhen-China) LABORATORIES
                            Zone A, Floor 1, Building 2 Wan Ye Long Technology Park
 Lab Address                South Side of Zhoushi Road, Bao’ an District, Shenzhen, Guangdong China
                            518108
 FCC Test Site No.          535293
 IC Test Site No.           4842E-1
 Test Software              Radiated Emission Program-To Shenzhen v2.0


                                            Test Report   18070496-FCC-H
                                            Page
                                            No.           6 of 9




 4. Equipment under Test (EUT) Information
Description of EUT:             Mobile phone



Main Model:                     X606D


Serial Model:                   N/A


Date EUT received:              May 10, 2018


Test Date(s):                   May 11 to 22, 2018




Antenna Gain:                   Bluetooth/BLE: 1.97dBi




Antenna Type:                   PIFA Antenna


                                Bluetooth: GFSK, π /4DQPSK, 8DPSK
Type of Modulation:
                                BLE: GFSK



RF Operating Frequency (ies):   Bluetooth& BLE: 2402-2480 MHz



                                Bluetooth: 79CH
Number of Channels:
                                BLE: 40CH


Port:                           USB Port, Earphone Port

                                Adapter :
                                Model: A88-502000
                                Input: AC100-240V~50/60Hz,0.35A
                                Output: DC 5.0V, 2.0A
Input Power:                    Battery :
                                Model: BL-39HX
                                Rating: 3.85V, 3900mAh/4000mAh (min/typ)
                                        15.01Wh/15.40Wh (min/typ)
                                Limited charge voltage: 4.4V


                         Test Report   18070496-FCC-H
                         Page
                         No.           7 of 9



Trade Name :   Infinix



FCC ID:        2AIZN-X606D


                                             Test Report     18070496-FCC-H
                                             Page
                                             No.             8 of 9




 5. FCC §2.1093 - Radiofrequency radiation exposure evaluation: portable
      devices.



   5.1 RF Exposure

Standard Requirement:


According to §15.247 (i) and §1.1307(b)(1), systems operating under the provisions of this section shall be
operated in a manner that ensures that the public is not exposed to radio frequency energy level in excess of
the Commission’ s guidelines.




Routine SAR evaluation refers to that specifically required by § 2.1093, using measurements or computer
simulation. When routine SAR evaluation is not required, portable transmitters with output power greater
than the applicable low threshold require SAR evaluation to qualify for TCB approval.


result = P F / D
P= Maximum turn-up power in mW
F= Channel frequency in GHz
D= Minimum test separation distance in mm


                                         Test Report      18070496-FCC-H
                                         Page
                                         No.              9 of 9




 5.2 Test Result
 Bluetooth Mode:
                       Freque      Conducted     Tune Up       Max Tune       Max Tune
Modulation      CH       ncy        Power         Power            Up Power   Up Power   Result   Limit
                       (MHz)        (dBm)         (dBm)             (dBm)      (mW)
               Low      2402         0.543         1±1                2        1.585     0.49      3
  GFSK         Mid      2441         0.943         1±1                2        1.585     0.50      3
               High     2480         1.584         1±1                2        1.585     0.50      3
               Low      2402         0.350        0.5±1              1.5       1.413     0.44      3
π /4 DQPSK     Mid      2441         0.716        0.5±1              1.5       1.413     0.44      3
               High     2480         1.258        0.5±1              1.5       1.413     0.44      3
               Low      2402         0.599         1±1                2        1.585     0.49      3
 8-DPSK        Mid      2441         1.001         1±1                2        1.585     0.50      3
               High     2480         1.526         1±1                2        1.585     0.50      3


 BLE Mode:
                                   Conducted     Tune Up       Max Tune       Max Tune
                        Freq
Modulation      CH                  Power         Power            Up Power   Up Power   Result   Limit
                       (MHz)
                                    (dBm)         (dBm)             (dBm)      (mW)
               Low      2402         0.395        0.5±1              1.5       1.413     0.44      3
  GFSK         Mid      2440         0.492        0.5±1              1.5       1.413     0.44      3
               High     2480         1.250        0.5±1              1.5       1.413     0.44      3


 Result: Compliance
 No SAR measurement is required.



Document Created: 2018-05-29 15:20:51
Document Modified: 2018-05-29 15:20:51

© 2024 FCC.report