RF Test Report

FCC ID: 2AIRRINT116

Test Report

Download: PDF
FCCID_4199386

                         Test Report No.: RF190115N026



                                                                 TEST REPORT
   Applicant                        International Toy, Inc.

   Address                          2151 Michelson Drive STE 185, Irvine, California,United States 92612


   Manufacturer or
                                    International Toy, Inc.
   Supplier

   Address                          2151 Michelson Drive STE 185, Irvine, California,United States 92612

   Product                          AN19 SITH HOLOCRON

   Brand Name                       Disney

   Model                            400021017542

   Additional Model &
   Model Difference                 N/A

   Date of tests                    Jan. 15, 2019 ~ Feb. 13, 2019

   The submitted sample of the above equipment has been tested for according to the requirements of the
   following standards:

        FCC Part 15, Subpart C

   CONCLUSION: The submitted sample was found to COMPLY with the test requirement

                        Tested by Tom Chen                                                                Approved by Glyn He
                Project Engineer / EMC Department                                                      Supervisor/ EMC Department




                                                                                                              Date: Feb. 28, 2019
   This report is governed by, and incorporates by reference, CPS Conditions of Service as posted at the date of issuance of this report at
   http://www.bureauveritas.com/home/about-us/our-business/cps/about-us/terms-conditions/and is intended for your exclusive use. Any copying or
   replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This report
   sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or representative of the
   quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our
   report includes all of the tests requested by you and the results thereof based upon the information that you provided to us. Measurement uncertainty is
   only provided upon request for accredited tests. You have 60 days from date of issuance of this report to notify us of any material error or omission caused
   by our negligence or if you require measurement uncertainty; provided, however, that such notice shall be in writing and shall specifically address the issue
   you wish to raise. A failure to raise such issue within the prescribed time shall constitute you unqualified acceptance of the completeness of this report, the
   tests conducted and the correctness of the report contents.



                                                    No. 34, Chenwulu Section, Guantai Rd., Houjie                Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                                    Town, Dongguan City,                                         Fax: +86 769 8593 1080
Dongguan Branch
                                                    Guangdong 523942, China                                      Email: customerservice.dg@cn.bureauveritas.com
                                                                         Page 1 of 26                                                                Report Version 1


                        Test Report No.: RF190115N026


                                               TABLE OF CONTENTS
    RELEASE CONTROL RECORD ............................................................................................................ 3

    1      SUMMARY OF TEST RESULTS ..................................................................................................... 4

    2      MEASUREMENT UNCERTAINTY .................................................................................................. 4

    3      GENERAL INFORMATION .............................................................................................................. 5
        3.1      GENERAL DESCRIPTION OF EUT ......................................................................................... 5
        3.2      DESCRIPTION OF TEST MODES ........................................................................................... 6
        3.3      GENERAL DESCRIPTION OF APPLIED STANDARDS .......................................................... 6
        3.4      DESCRIPTION OF SUPPORT UNITS ..................................................................................... 6
    4      EMISSION TEST.............................................................................................................................. 7
        4.1    CONDUCTED EMISSION MEASUREMENT ........................................................................... 7
          4.1.1   LIMITS OF CONDUCTED EMISSION MEASUREMENT ................................................. 7
          4.1.2   TEST INSTRUMENTS ....................................................................................................... 7
          4.1.3   TEST PROCEDURE .......................................................................................................... 8
          4.1.4   DEVIATION FROM TEST STANDARD ............................................................................. 8
          4.1.5   TEST SETUP ..................................................................................................................... 9
          4.1.6   EUT OPERATING CONDITIONS ...................................................................................... 9
          4.1.7   TEST RESULTS .............................................................................................................. 10
        4.2    RADIATED EMISSION MEASUREMENT .............................................................................. 12
          4.2.1   LIMITS OF RADIATED EMISSION MEASUREMENT .................................................... 12
          4.2.2   TEST INSTRUMENTS ..................................................................................................... 13
          4.2.3   TEST PROCEDURE ........................................................................................................ 14
          4.2.4   DEVIATION FROM TEST STANDARD ........................................................................... 14
          4.2.5   TEST SETUP ................................................................................................................... 15
          4.2.6   EUT OPERATING CONDITIONS .................................................................................... 15
          4.2.7   TEST RESULTS .............................................................................................................. 16
        4.3. 20dB BANDWIDTH MEASUREMENT .................................................................................... 22
          4.3.1   LIMITS OF 20dB BANDWIDTH MEASUREMENT .......................................................... 22
          4.3.2   TEST INSTRUMENTS ..................................................................................................... 22
          4.3.3   TEST PROCEDURE ........................................................................................................ 23
          4.3.4   DEVIATION FROM TEST STANDARD ........................................................................... 23
          4.3.5   TEST SETUP ................................................................................................................... 23
          4.3.6   EUT OPERATING CONDITION ...................................................................................... 24
          4.3.7   TEST RESULTS .............................................................................................................. 24
    5      PHOTOGRAPHS OF THE TEST CONFIGURATION ................................................................... 25

    6      APPENDIX A – MODIFICATIONS RECORDERS FOR ENGINEERING CHANGES TO THE EUT
           BY THE LAB .................................................................................................................................. 26




                                                   No. 34, Chenwulu Section, Guantai Rd., Houjie              Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                                   Town, Dongguan City,                                       Fax: +86 769 8593 1080
Dongguan Branch
                                                   Guangdong 523942, China                                    Email: customerservice.dg@cn.bureauveritas.com
                                                                       Page 2 of 26                                                              Report Version 1


                    Test Report No.: RF190115N026


                                    RELEASE CONTROL RECORD

     ISSUE NO.                  REASON FOR CHANGE                                                         DATE ISSUED

     RF190115N026               Original release                                                          Feb. 28, 2019




                                      No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                      Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch
                                      Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                      Page 3 of 26                                                    Report Version 1


                    Test Report No.: RF190115N026


    1 SUMMARY OF TEST RESULTS

    The EUT has been tested according to the following specifications:


                               APPLIED STANDARD: FCC Part 15, Subpart C
      STANDARD
                              TEST TYPE AND LIMIT                    RESULT                     REMARK
       SECTION
         §15.203                Antenna Requirement                    PASS       No antenna connector is used.

         §15.207          AC Power Conducted Emission                  PASS        Meet the requirement of limit.

         §15.209                    Radiated Emission                  PASS        Meet the requirement of limit.

       §15.215 (c)                   20dB Bandwidth                    PASS        Meet the requirement of limit.




    2 MEASUREMENT UNCERTAINTY
    Where relevant, the following measurement uncertainty levels have been estimated for
    tests performed on the EUT as specified in CISPR 16-4-2:

                    MEASUREMENT                               FREQUENCY                           UNCERTAINTY
                  Conducted emissions                          9kHz~30MHz                                2.70dB
                                                             9KHz ~ 30MHz                                2.16dB
                   Radiated emissions
                                                            30MHz ~ 1GMHz                                4.04dB


    This uncertainty represents an expanded uncertainty expressed at approximately the 95%
    confidence level using a coverage factor of k=2.




                                        No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                        Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch
                                        Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                        Page 4 of 26                                                    Report Version 1


                    Test Report No.: RF190115N026

  3       GENERAL INFORMATION
      3.1 GENERAL DESCRIPTION OF EUT
      PRODUCT                             AN19 SITH HOLOCRON
      MODEL NO.                           400021017542
      ADDITIONAL MODELS                   N/A
      FCC ID                              2AIRRINT116
                                          DC 3.7V from Li-ion Battery
      POWER SUPPLY
                                          Charging: DC 5V from USB Host Unit
      MODULATION TYPE                     AM
      OPERATING FREQUENCY                 110KHz ~ 150KHz
      ANTENNA TYPE                        Coil Antenna with 0dBi
      CABLE SUPPLIED                      USB cable: Unshielded, detachable, 1m Max

      NOTES:
      1. For a more detailed features description, please refer to the manufacturer’s specifications or the user's
         manual.
      2. For the test results, the EUT had been tested with all conditions. But only the worst case was shown in
         test report.
      3. Please refer to the EUT photo document (Reference No.: 190115N026) for detailed product photo.




                                      No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                      Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch
                                      Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                      Page 5 of 26                                                    Report Version 1


                    Test Report No.: RF190115N026


  3.2    DESCRIPTION OF TEST MODES

    The EUT was tested under the following modes the final worst mode was marked in
    boldface and recorded in this report.

         TEST FREQUENCY                            TEST MODE                                 TEST VOLTAGE
              110 - 150KHz                    Transmiting+Charging                         DC 5V from Adapter




    3.3 GENERAL DESCRIPTION OF APPLIED STANDARDS
    The EUT is a RF Product. According to the specifications of the manufacturer, it must comply with the
    requirements of the following standards:


    FCC Part 15, Subpart C
    ANSI C63.10-2013

    All test items have been performed and recorded as per the above standards.




  3.4      DESCRIPTION OF SUPPORT UNITS


      The EUT has been tested as an independent unit together with other necessary
      accessories or support units. The following support units or accessories were used to
      form a representative test configuration during the tests.

             NO.     PRODUCT        BRAND          MODEL NO.              SERIAL NO.                     FCC ID
              1       Adapter       Apple              A1443                   N/A                         N/A
              2       Adapter       InFocus        C5010-C08N                  N/A                         N/A


             NO.             SIGNAL CABLE DESCRIPTION OF THE ABOVE SUPPORT UNITS
             1-2 N/A




                                    No. 34, Chenwulu Section, Guantai Rd., Houjie    Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                    Town, Dongguan City,                             Fax: +86 769 8593 1080
Dongguan Branch
                                    Guangdong 523942, China                          Email: customerservice.dg@cn.bureauveritas.com
                                                    Page 6 of 26                                                     Report Version 1


                    Test Report No.: RF190115N026

    4     EMISSION TEST
    4.1 CONDUCTED EMISSION MEASUREMENT
    4.1.1 LIMITS OF CONDUCTED EMISSION MEASUREMENT


                                            Class A (dBuV)                       Class B (dBuV)
          FREQUENCY (MHz)
                                         Quasi-peak   Average                Quasi-peak Average
                 0.15 - 0.5                 79          66                     66 - 56     56 - 46
                 0.50 - 5.0                 73          60                       56          46
                 5.0 - 30.0                 73          60                       60          50

        NOTES: (1) The lower limit shall apply at the transition frequencies.
               (2) The limit decreases in line with the logarithm of the frequency in the range of 0.15 to 0.50
                   MHz.
               (3) All emanations from a class A/B digital device or system, including any network of
                      conductors and apparatus connected thereto, shall not exceed the level of field strengths
                      specified above.


    4.1.2 TEST INSTRUMENTS
   Equipment                  Manufacturer  Model No.            Serial No.     Last Cal.           Next Cal.
   EMI Test Receiver          Rohde&Schwarz ESR7                 101494         Mar. 21,18          Mar. 20,19
   Artificial Mains
                              Rohde&Schwarz ENV216               101173         Mar. 03,18          Mar. 02,19
   Network
   Artificial Mains
                              Rohde&Schwarz ESH3-Z5              100317         Apr. 11,18          Apr. 10,19
   Network
                                                                 TK
   Voltage probe              SCHWARZBECK TK 9421                               Jan. 17,19          Jan. 16,20
                                                                 9421-176
                                                ADT_Cond_
   Test software              ADT                         N/A                   N/A                 N/A
                                                V7.3.7
     NOTES:
       1. The test was performed in shielded room 553.
       2. The calibration interval of the above test instruments is 12 months. And the calibrations are traceable
          to CEPREI/CHINA, GRGT/CHINA and NIM/CHINA.




                                     No. 34, Chenwulu Section, Guantai Rd., Houjie    Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                     Town, Dongguan City,                             Fax: +86 769 8593 1080
Dongguan Branch
                                     Guangdong 523942, China                          Email: customerservice.dg@cn.bureauveritas.com
                                                     Page 7 of 26                                                     Report Version 1


                    Test Report No.: RF190115N026

    4.1.3 TEST PROCEDURE

    The basic test procedure was in accordance with ANSI C63.4:2014 (section 7).

    a. The EUT was placed 0.4 meters from the conducting wall of the shielded room with
       EUT being connected to the power mains through a line impedance stabilization
       network (LISN). Other support units were connected to the power mains through
       another LISN. The two LISNs provide 50 Ohm/ 50uH of coupling impedance for the
       measuring instrument.

    b. Both lines of the power mains connected to the EUT were checked for maximum
       conducted interference.

    c. The frequency range from 150 kHz to 30 MHz was searched. Emission levels under
       (Limit – 20dB) were not recorded.

     NOTES:

     1. Q.P. and AV. are abbreviations of quasi-peak and average individually.
     2. "-": The Quasi-peak reading value also meets average limit and
        measurement with the average detector is unnecessary.
     3. Margin value = Emission level - Limit value
     4. Correction factor = Insertion loss + Cable loss
     5. Emission Level = Correction Factor + Reading Value



    4.1.4 DEVIATION FROM TEST STANDARD

    No deviation.




                                     No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                     Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch
                                     Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                     Page 8 of 26                                                    Report Version 1


                    Test Report No.: RF190115N026

    4.1.5 TEST SETUP

                            V e r t ic a l G r o u n d
                            R e f e r e n c e P la n e                                            T e s t R e c e iv e r


                            EUT
          40cm




                                                           80cm

           L IS N



                                                                              H o r iz o n t a l G r o u n d
                                                                              R e f e r e n c e P la n e

        N o t e : 1 .S u p p o r t u n it s w e r e c o n n e c t e d t o s e c o n d L IS N .
                 2 .B o t h o f L IS N s ( A M N ) a r e 8 0 c m f r o m E U T a n d a t le a s t 8 0 c m
                    f r o m o t h e r u n it s a n d o t h e r m e t a l p la n e s s u p p o r t u n it s .


    4.1.6 EUT OPERATING CONDITIONS
            a. Turned on the power of all equipment.
            b. EUT was operated according to the type description in manufacturer’s
                specifications or the User's Manual.




                                         No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                         Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch
                                         Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                         Page 9 of 26                                                    Report Version 1


                    Test Report No.: RF190115N026

    4.1.7 TEST RESULTS

       TEST MODE                Transmiting+Charging             6DB BANDWIDTH 9 kHz
                                DC 5V from Adapter Input
       TEST VOLTAGE                                              PHASE                        Line (L)
                                AC 120V 60Hz
       ENVIRONMENTAL
                                25deg.C, 55% RH                  TESTED BY                    Dragon
       CONDITIONS

                                                           Emission
                Freq.        Corr.   Reading Value                                    Limit               Margin
                                                             Level
       No.                  Factor      [dB (uV)]          [dB (uV)]           [dB (uV)]                   (dB)
                [MHz]        (dB)      Q.P.    AV.        Q.P.    AV.         Q.P.    AV.             Q.P.      AV.
         1     0.18856      10.03     14.52    4.07      24.55 14.10         64.10 54.10             -39.55 -40.00
         2     0.74424      10.13     9.69     5.90      19.82 16.03         56.00 46.00             -36.18 -29.97
         3     2.53380       9.97     1.99    -2.62      11.96   7.35        56.00 46.00             -44.04 -38.65
         4     3.59475       9.76     4.56    -2.53      14.32   7.23        56.00 46.00             -41.68 -38.77
         5     4.50557      10.02     4.97    -1.66      14.99   8.36        56.00 46.00             -41.01 -37.64
         6    16.78875       9.92     9.08     4.57      19.00 14.49         60.00 50.00             -41.00 -35.51

         REMARK:        The emission levels of other frequencies were very low against the limit.




                                      No. 34, Chenwulu Section, Guantai Rd., Houjie     Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                      Town, Dongguan City,                              Fax: +86 769 8593 1080
Dongguan Branch
                                      Guangdong 523942, China                           Email: customerservice.dg@cn.bureauveritas.com
                                                     Page 10 of 26                                                      Report Version 1


                    Test Report No.: RF190115N026




       TEST MODE                Transmiting+Charging             6DB BANDWIDTH 9 kHz
                                DC 5V from Adapter Input
       TEST VOLTAGE                                              PHASE                        Neutral (N)
                                AC 120V 60Hz
       ENVIRONMENTAL
                                25deg.C, 55% RH                  TESTED BY                    Dragon
       CONDITIONS

                                                           Emission
                Freq.        Corr.   Reading Value                                    Limit                Margin
                                                             Level
       No.                  Factor     [dB (uV)]           [dB (uV)]           [dB (uV)]                     (dB)
                [MHz]        (dB)     Q.P.    AV.         Q.P.    AV.         Q.P.    AV.             Q.P.          AV.
         1     0.16524      10.18    13.52    1.00       23.70 11.18         65.20 55.20             -41.50       -44.02
         2     0.70970      10.02    6.67    -0.73       16.69   9.29        56.00 46.00             -39.31       -36.71
         3     1.57425       9.98    1.43    -3.11       11.41   6.87        56.00 46.00             -44.59       -39.13
         4     2.43150       9.85    0.26    -3.25       10.11   6.60        56.00 46.00             -45.89       -39.40
         5     4.47002       9.73    5.39    -0.39       15.12   9.34        56.00 46.00             -40.88       -36.66
         6    16.51425       9.85    6.44     3.98       16.29 13.83         60.00 50.00             -43.71       -36.17

       REMARK:       The emission levels of other frequencies were very low against the limit.




                                      No. 34, Chenwulu Section, Guantai Rd., Houjie     Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                      Town, Dongguan City,                              Fax: +86 769 8593 1080
Dongguan Branch
                                      Guangdong 523942, China                           Email: customerservice.dg@cn.bureauveritas.com
                                                     Page 11 of 26                                                      Report Version 1


                    Test Report No.: RF190115N026

    4.2 RADIATED EMISSION MEASUREMENT
    4.2.1 LIMITS OF RADIATED EMISSION MEASUREMENT

      TEST STANDARD: FCC Part 15, Subpart C, Section 15.209

    Emissions radiated outside of the specified bands, shall be according to the general
    radiated limits as following:

                   FREQUENCIES                  FIELD STRENGTH                   MEASUREMENT DISTANCE
                      (MHz)                     (microvolts/meter)                     (meters)
                   0.009 – 0.490                  2400/F(kHz)                                    300
                   0.490 – 1.705                  24000/F(kHz)                                    30
                   1.705 – 30.0                        30                                         30
                      30 – 88                         100                                         3
                     88 – 216                         150                                         3
                     216 - 960                        200                                         3
                    Above 960                         500                                         3
          NOTES:
         1. The lower limit shall apply at the transition frequencies.
         2. Emission level (dBuV/m) = 20 log Emission level (uV/m).
         3. As shown in 15.35(b), for frequencies above 1000MHz, the field strength limits are based on average
             detector, however, the peak field strength of any emission shall not exceed the maximum permitted
             average limits, specified above by more than 20dB under any condition of modulation.
         4. The measured field strength was extrapolated to distance 30 meters, using the formula that the limit of
            field strength varies as the inverse distance square (40dB per decade of distance)
             Example:
             13.56MHz = 15848uV/m                       30m
                          = 84dBuV/m                    30m
                          = 84+20log(30/3)2             3m
                         =   124dBuV/m




                                      No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                      Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch
                                      Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                     Page 12 of 26                                                    Report Version 1


                    Test Report No.: RF190115N026

    4.2.2 TEST INSTRUMENTS
         FREQUENCY 9KHz-30MHz
          Equipment         Manufacturer                 Model No.          Serial No.      Last Cal.          Next Cal.
          EMI Test Receiver Rohde&Schwarz                ESR7               101564          Jan. 18,19         Jan. 17,20
          Active Loop
                            SCHWARZBECK                  FMZB 1519B         1519B-045 May 04,18                May 03,19
          Antenna
          Amplifier         Burgeon                      BPA-530      100210                Apr. 18,18         Apr. 18,19
                                                         ADT_Radiated
          Test Software             ADT                               N/A                   N/A                N/A
                                                         _V8.7.07
         NOTES: 1. The test was performed in 10m Chamber.
                2. The calibration interval of the above test instruments is 12 months. And the calibrations are
                 traceable to CEPREI/CHINA, GRGT/CHINA and NIM/CHINA.
                   3. The FCC Site Registration No. is 749762.


         FREQUENCY 30MHz-1GHz
         Equipment         Manufacturer                  Model No.          Serial No.            Last Cal.         Next Cal.
         EMI Test Receiver Rohde&Schwarz                 ESU40              100449                Mar. 21,18        Mar. 20,19
         Bilog Antenna     Teseq                         CBL 6111D          30643                 Aug.11,18         Aug. 10,19
         Amplifier         Burgeon                       BPA-530            100220                Apr. 18,18        Apr. 18,19
         3m Semi-anechoic
                           ETS-LINDGREN                  9m*6m*6m           NSEMC003              Feb. 10,19        Feb. 09,20
         Chamber
                                                         ADT_Radiated
          Test software             ADT                               N/A                         N/A               N/A
                                                         _V7.6.15.9.2
          NOTES: 1. The test was performed in 966 Chamber
                 2. The calibration interval of the above test instruments is 12 months. And the calibrations are
                    traceable to CEPREI/CHINA, GRGT/CHINA and NIM/CHINA.
                 3. The FCC Site Registration No. is 749762.




                                          No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                          Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch
                                          Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                         Page 13 of 26                                                    Report Version 1


                    Test Report No.: RF190115N026

    4.2.3 TEST PROCEDURE

    < Below 30MHz >
      a. The EUT was placed on the top of a rotating table 0.8 meters above the ground at
         a 10 meters Semi-anechoic chamber room. The table was rotated 360 degrees to
         determine the position of the highest radiation.
      b. The EUT was set 3 meters away from the interference-receiving antenna, which
         was mounted on the top of a variable-height antenna tower.
      c. The height of antenna is varied from one meter to four meters above the ground to
         determine the maximum value of the field strength. Both horizontal and vertical
         polarizations of the antenna are set to make the measurement.
      d. For each suspected emission, the EUT was arranged to its worst case and then
         the antenna was tuned to heights from 1 meter to 4 meters and the rotatable table
         was turned from 0 degrees to 360 degrees to find the maximum reading.
      e. The test-receiver system was set to quasi-peak detect function and specified
         bandwidth with maximum hold mode when the test frequency is below 1 GHz.
      f. For below 30MHz, a loop antenna with its vertical plane is place 3m from the EUT
         and rotated about its vertical axis for maximum response at each azimuth about the
         EUT. And the centre of the loop shall be 1m above the ground.
    <30MHz~1GHz >
      a. The EUT was placed on the top of a rotating table 0.8 meters above the ground at
         a 3 meters semi-anechoic chamber. The table was rotated 360 degrees to
         determine the position of the highest radiation.
      b. The EUT was set 3 meters away from the interference-receiving antenna, which
         was mounted on the top of a variable-height antenna tower.
      c. The antenna is a broadband antenna, and its height is varied from one meter to
         four meters above the ground to determine the maximum value of the field
         strength. Both horizontal and vertical polarizations of the antenna are set to make
         the measurement.
      d. For each suspected emission, the EUT was arranged to its worst case and then
         the antenna was tuned to heights from 1 meter to 4 meters and the rotatable table
         was turned from 0 degrees to 360 degrees to find the maximum reading.
      e. The test-receiver system was set to Peak Detect Function and Specified
         Bandwidth with Maximum Hold Mode.

      NOTES:
      1. The resolution bandwidth of test receiver/spectrum analyzer is 120kHz for Quasi-peak detection (QP) at
         frequency below 1GHz.
      2. Emission level(dBuV/m)=Raw Value(dBuV) + Correction Factor(dB/m)
      3. Correction Factor(dB/m) = Antenna Factor (dB/m) + Cable Factor (dB)
      4. Margin value = Emission level – Limit value.

    4.2.4 DEVIATION FROM TEST STANDARD

    No deviation.
                                    No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                    Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch
                                    Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                   Page 14 of 26                                                    Report Version 1


                    Test Report No.: RF190115N026


    4.2.5 TEST SETUP

    Below 30MHz test setup




    Below 1GHz test setup
                                                                       Ant. Tower
                                                                                                    1-4m
                                                       3m
                               EUT

                                                Turn Table

                        0.8m


                                                     Ground Plane

                                                    Spectrum




    Note: For the actual test configuration, please refer to the attached file (Test Setup Photo).




    4.2.6 EUT OPERATING CONDITIONS
         a. Turn on the power supply of the EUT.
         b. EUT was operated according to the type description in
            manufacturer’s specifications or the User's Manual.


                                     No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                     Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch
                                     Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                    Page 15 of 26                                                    Report Version 1


                    Test Report No.: RF190115N026

    4.2.7 TEST RESULTS


                                                                   FREQUENCY
        TEST MODE                   Transmiting+Charging                                      9 -150KHz
                                                                   RANGE
                                                             DETECTOR
                                    DC 5V from Adapter Input FUNCTION &
        TEST VOLTAGE                                                                          Quasi-Peak, 200Hz
                                    AC 120V 60Hz             RESOLUTION
                                                             BANDWIDTH
        ENVIRONMENTAL
                                    21deg. C, 67% RH               TESTED BY: Vincent
        CONDITIONS

                       ANTENNA POLARITY & TEST DISTANCE: HORIZONTAL AT 3M
                       Correction  Raw   Emission                  Antenna                                     Table
       No      Freq.                                 Limit  Margin
                         Factor    Value   Level                    Height                                     Angle
        .     (MHz)                               (dBuV/m)   (dB)
                        (dB/m)    (dBuV) (dBuV/m)                    (cm)                                    (Degree)
        1     0.035      -11.08    50.11   39.03    116.66  -77.63    100                                       257
        2     0.056      -11.42    36.99   25.57    112.65  -87.08    100                                        69
        3     0.064      -11.40    38.96   27.56    111.44  -83.88    100                                       112
        4     0.072      -11.38    34.02   22.64    110.50  -87.86    100                                       223
        5     0.112      -11.29    26.58   15.29    106.63  -91.34    100                                       233
        6     0.129      -11.25    31.13   19.88    105.42  -85.54    100                                        29

    REMARKS: 1. Peak detector quick scan is showed on the graph and final quasi-peak detector data is
                  measured corresponding to relevant limit and recorded in the data table.
               2. Negative sign (-) in the margin column signify levels below the limit.
               3. Frequency range scanned: 0.009-0.15MHz.
               4. Only emissions significantly above equipment noise floor are reported.




                                       No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                       Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch
                                       Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                      Page 16 of 26                                                    Report Version 1


                    Test Report No.: RF190115N026


                                                                 FREQUENCY
        TEST MODE                   Transmiting+Charging                                    9 -150KHz
                                                                 RANGE
                                                                 DETECTOR
                                    DC 5V from Adapter           FUNCTION &
        TEST VOLTAGE                                                                        Quasi-Peak, 200Hz
                                    Input AC 120V 60Hz           RESOLUTION
                                                                 BANDWIDTH
        ENVIRONMENTAL
                                    21deg. C, 67% RH             TESTED BY: Vincent
        CONDITIONS

                         ANTENNA POLARITY & TEST DISTANCE: VERTICAL AT 3M
                       Correction  Raw   Emission                    Antenna                                      Table
       No     Freq.                                   Limit  Margin
                        Factor     Value   Level                      Height                                      Angle
        .    (MHz)                                 (dBuV/m)   (dB)
                        (dB/m)    (dBuV) (dBuV/m)                      (cm)                                     (Degree)
        1    0.035      -11.08     49.08   38.00     116.66  -78.66     100                                        290
        2    0.056      -11.42     36.01   24.59     112.65  -88.06     100                                        352
        3    0.064      -11.40     37.89   26.49     111.44  -84.95     100                                        343
        4    0.072      -11.38     32.72   21.34     110.51  -89.17     100                                        360
        5    0.112      -11.29     24.85   13.56     106.63  -93.07     100                                        278
        6    0.129      -11.25     29.77   18.52     105.42  -86.90     100                                        356

    REMARKS: 1. Peak detector quick scan is showed on the graph and final quasi-peak detector data is
                  measured corresponding to relevant limit and recorded in the data table.
               2. Negative sign (-) in the margin column signify levels below the limit.
               3. Frequency range scanned: 0.009-0.15MHz.
               4. Only emissions significantly above equipment noise floor are reported.




                                       No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                       Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch
                                       Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                      Page 17 of 26                                                    Report Version 1


                    Test Report No.: RF190115N026


                                                                 FREQUENCY
        TEST MODE                   Transmiting+Charging                                    150KHz-30MHz
                                                                 RANGE
                                                                 DETECTOR
                                    DC 5V from Adapter           FUNCTION &
        TEST VOLTAGE                                                                        Quasi-Peak, 200Hz
                                    Input AC 120V 60Hz           RESOLUTION
                                                                 BANDWIDTH
        ENVIRONMENTAL
                                    21deg. C, 67% RH             TESTED BY: Vincent
        CONDITIONS

                 ANTENNA POLARITY & TEST DISTANCE: HORIZONTAL AT 3M
                 Correction  Raw   Emission                  Antenna                                           Table
       No Freq.                                Limit  Margin
                   Factor    Value   Level                    Height                                           Angle
        . (MHz)                             (dBuV/m)   (dB)
                  (dB/m)    (dBuV) (dBuV/m)                    (cm)                                          (Degree)
       1  0.277    -11.14    40.26   29.12    98.76   -69.64    100                                              43
       2   1.111   -10.92    23.27   12.35    67.34   -54.99    100                                             104
       3  3.428    -10.70    22.91   12.21    69.54   -57.33    100                                             299
       4  4.443    -10.67    26.46   15.79    69.54   -53.75    100                                             227
       5 12.223    -10.66    21.21   10.55    69.54   -58.99    100                                             246
       6 18.888    -10.24    20.15    9.91    69.54   -59.63    100                                             112

    REMARKS: 1. Peak detector quick scan is showed on the graph and final quasi-peak detector data is
                  measured corresponding to relevant limit and recorded in the data table.
               2. Negative sign (-) in the margin column signify levels below the limit.
               3. Frequency range scanned: 0.15-30MHz.
               4. Only emissions significantly above equipment noise floor are reported.




                                       No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                       Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch
                                       Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                      Page 18 of 26                                                    Report Version 1


                    Test Report No.: RF190115N026




                                                                 FREQUENCY
        TEST MODE                   Transmiting+Charging                                    150KHz-30MHz
                                                                 RANGE
                                                                 DETECTOR
                                    DC 5V from Adapter           FUNCTION &
        TEST VOLTAGE                                                                        Quasi-Peak, 200Hz
                                    Input AC 120V 60Hz           RESOLUTION
                                                                 BANDWIDTH
        ENVIRONMENTAL
                                    21deg. C, 67% RH             TESTED BY: Vincent
        CONDITIONS

                          ANTENNA POLARITY & TEST DISTANCE: VERTICAL AT 3M
                          Correction  Raw   Emission                  Antenna                                     Table
       No      Freq.                                   Limit  Margin
                           Factor     Value   Level                    Height                                     Angle
        .     (MHz)                                  (dBuV/m)  (dB)
                           (dB/m)    (dBuV) (dBuV/m)                    (cm)                                    (Degree)
        1     0.277        -11.14     40.27   29.13    98.76  -69.63     100                                        86
        2     0.832        -10.86     24.07   13.21    69.63  -56.42     100                                       199
        3     3.332        -10.72     22.79   12.07    69.54  -57.47     100                                       228
        4     4.444        -10.67     26.14   15.47    69.54  -54.07     100                                       324
        5     13.715       -10.74     21.03   10.29    69.54  -59.25     100                                       254
        6     19.428       -10.15     20.21   10.06    69.54  -59.48     100                                        34

    REMARKS: 1. Peak detector quick scan is showed on the graph and final quasi-peak detector data is
                  measured corresponding to relevant limit and recorded in the data table.
               2. Negative sign (-) in the margin column signify levels below the limit.
               3. Frequency range scanned: 0.15-30MHz
               4. Only emissions significantly above equipment noise floor are reported.




                                       No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                       Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch
                                       Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                      Page 19 of 26                                                    Report Version 1


                    Test Report No.: RF190115N026



                                                             FREQUENCY
        TEST MODE                   Transmiting+Charging                                         30-1000MHz
                                                             RANGE
                                                             DETECTOR
                                    DC 5V from Adapter Input FUNCTION &
        TEST VOLTAGE                                                                             Quasi-Peak, 120kHz
                                    AC 120V 60Hz             RESOLUTION
                                                             BANDWIDTH
        ENVIRONMENTAL
                                    23deg. C, 55% RH                 TESTED BY: Tank
        CONDITIONS

                        ANTENNA POLARITY & TEST DISTANCE: HORIZONTAL AT 3M
                          Correction  Raw   Emission                 Antenna   Table
                  Freq.                                Limit  Margin
        No.                 Factor    Value   Level                   Height  Angle
                 (MHz)                               (dBuV/m) (dB)
                            (dB/m)   (dBuV) (dBuV/m)                   (cm)  (Degree)
         1      30.000         -10.13        39.34         29.21          40.00         -10.79         200             0
         2       93.740        -18.99        37.43         18.44          43.50         -25.06         200             0
         3      183.810        -17.76        54.90         37.14          43.50          -6.36         200             0
         4      286.360        -13.41        48.29         34.88          46.00         -11.12         200             0
         5      350.100        -10.67        38.44         27.77          46.00         -18.23         200             0
         6      631.400         -4.98        30.24         25.26          46.00         -20.74         200             0

    REMARKS:         1. Peak detector quick scan is showed on the graph and final quasi-peak detector data is
                        measured corresponding to relevant limit and recorded in the data table.
                     2. Negative sign (-) in the margin column signify levels below the limit.
                     3. Frequency range scanned: 30MHz to 1000MHz.
                     4. Only emissions significantly above equipment noise floor are reported.




                                        No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                        Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch
                                        Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                       Page 20 of 26                                                    Report Version 1


                    Test Report No.: RF190115N026


                                                             FREQUENCY
        TEST MODE                   Transmiting+Charging                                        30-1000MHz
                                                             RANGE
                                                             DETECTOR
                                    DC 5V from Adapter Input FUNCTION &
        TEST VOLTAGE                                                                            Quasi-Peak, 120kHz
                                    AC 120V 60Hz             RESOLUTION
                                                             BANDWIDTH
        ENVIRONMENTAL
                                    21deg. C, 67% RH                 TESTED BY: Tank
        CONDITIONS

                        ANTENNA POLARITY & TEST DISTANCE: VERTICAL AT 3M
                          Correction Raw    Emission                 Antenna                                       Table
                  Freq.                                Limit  Margin
        No.                Factor     Value   Level                   Height                                      Angle
                 (MHz)                               (dBuV/m) (dB)
                           (dB/m)    (dBuV) (dBuV/m)                   (cm)                                      (Degree)
          1     36.930         -14.01       43.43        29.42         40.00        -10.58          100                0
          2      92.360        -19.19       41.01        21.82         43.50        -21.68          100                0
          3     203.210        -17.95       43.16        25.21         43.50        -18.29          100                0
          4     308.530        -12.37       34.77        22.40         46.00        -23.60          100                0
          5     361.190        -10.34       34.03        23.69         46.00        -22.31          100                0
          6     954.270         -0.28       34.14        33.86         46.00        -12.14          100                0

    REMARKS:         1. Peak detector quick scan is showed on the graph and final quasi-peak detector data is
                        measured corresponding to relevant limit and recorded in the data table.
                     2. Negative sign (-) in the margin column signify levels below the limit.
                     3. Frequency range scanned: 30MHz to 1000MHz.
                     4. Only emissions significantly above equipment noise floor are reported.




                                        No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                        Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch
                                        Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                       Page 21 of 26                                                    Report Version 1


                    Test Report No.: RF190115N026

    4.3. 20dB BANDWIDTH MEASUREMENT


    4.3.1 LIMITS OF 20dB BANDWIDTH MEASUREMENT
    The field strength of any emissions appearing between the band edges and out of band
    shall be attenuated at least 20 dB below the level of the unmodulated carrier or to the
    general limits in Section 15.209.

    4.3.2 TEST INSTRUMENTS

    Equipment                 Manufacturer          Model No.        Serial No.         Last Cal.        Next Cal.
    Power Sensor              Keysight              U2021XA          MY55060016         Jun. 13,18       Jun. 12,19
    Power Sensor              Keysight              U2021XA          MY55060018         Jun. 13,18       Jun. 12,19
    Power Meter               Anritsu               ML2495A          1139001            Apr. 13,18       Apr. 13,19
    Power Sensor              Anritsu               MA2411B          1531155            Apr. 13,18       Apr. 13,19
    Digital Multimeter        FLUKE                 15B              A1220010DG         Oct. 17, 18 Oct.16, 19
    Humid & Temp
                              Haida                 HD-2257          110807201          Sep.20,18        Sep. 19,19
    Programmable Tester
    Oscilloscope              Agilent         DSO9254A               MY51260160         Nov. 08,18       Nov. 07,19
    Signal Analyzer           Rohde & Schwarz FSV7                   102331             Nov. 04,18       Nov. 03,19
    Signal Generator          Agilent               N5183A             MY50140980 Jan. 02, 19 Jan. 01, 20
    Agile Signal
                              Agilent               8645A            Agilent            Oct. 27, 18 Oct. 26, 19
    Generator
    Spectrum Analyzer         Keysight              N9020A           MY55400499         Mar. 21,18       Mar. 20,19
    MXG-B RF Vector
                     Keysight                       N5182B           MY56200288         Jan. 02, 19 Jan. 01, 20
    Signal Generator
    BLUETOOTH
                              Rohde&Schwarz CBT32                    100811             Jul. 06, 18      Jul. 05, 19
    TESTER
    Attenuator                MINI                  BW-S10W2+ S130129FGE2 N/A                            N/A
    DC Source                 Keysight              E3642A           MY56146098         N/A              N/A
    NOTES:
       1. The test was performed in RF Oven room.
       2. The calibration interval of the above test instruments is 12 months and the calibrations are traceable
        to CEPREI/CHINA, GRGT/CHINA and NIM/CHINA.




                                        No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                        Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch
                                        Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                       Page 22 of 26                                                    Report Version 1


                    Test Report No.: RF190115N026


    4.3.3 TEST PROCEDURE
      a. Check the calibration of the measuring instrument using either an internal calibrator or a known signal
          from an external generator.

      b. Turn on the EUT and connect it to measurement instrument. Then set it to any one convenient
          frequency within its operating range. Set a reference level on the measuring instrument equal to the
          highest peak value.

      c. Measure the frequency difference of two frequencies that were attenuated 20dB from the reference level.
          Record the frequency difference as the emission bandwidth.

      d. Repeat above procedures until all frequencies measured were complete.




    4.3.4 DEVIATION FROM TEST STANDARD

    No deviation.



    4.3.5 TEST SETUP

                     EUT                                                SPECTRUM
                                                                        ANALYZER
                                             10dB ATTENUATION
                                             PAD




                                    No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                    Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch
                                    Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                   Page 23 of 26                                                    Report Version 1


                    Test Report No.: RF190115N026



    4.3.6 EUT OPERATING CONDITION


    a. Turn on the EUT.
    b. The EUT tested in Transmiting mode respectively.




    4.3.7 TEST RESULTS



                    TEST MODE                  CHANNEL FREQUENCY (KHz)                     20dB BANDWIDTH (Hz)

                Transmiting+Charging                         121.9204                                   792.0


                Lower & Upper Test Frequency Point                   Test Frequency
                                                                                                         P/F
                              (MHz)                                       (KHz)
                                    Lower                                121.5412                       PASS
                                    Upper                                122.3332                       PASS

    Test Data:




                                      No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                      Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch
                                      Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                     Page 24 of 26                                                    Report Version 1


                    Test Report No.: RF190115N026


    5      PHOTOGRAPHS OF THE TEST CONFIGURATION


     Please refer to the attached file (Test Setup Photo).




                                    No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                    Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch
                                    Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                   Page 25 of 26                                                    Report Version 1


                    Test Report No.: RF190115N026


   6 APPENDIX A – MODIFICATIONS RECORDERS FOR ENGINEERING
       CHANGES TO THE EUT BY THE LAB

    No any modifications were made to the EUT by the lab during the test.




    ---END---




                                    No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                    Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch
                                    Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                   Page 26 of 26                                                    Report Version 1



Document Created: 2019-03-13 09:53:15
Document Modified: 2019-03-13 09:53:15

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC