Test Report

FCC ID: 2AIRPYW710710

Test Report

Download: PDF
FCCID_3106522

                         Test Report No.:RF160506N054


                                                                 TEST REPORT
       Applicant                      Alpha Group Co., Ltd.
                                      AULDEYIND. AREA, WENGUAN RD.(CENTRAL), CHENGHAI, SHANTOU,
       Address
                                      GUANGDONG, CHINA


       Manufacturer or
                                      --
       Supplier

       Address                        --

       Product                        Fly ‘Em Fast! Jett


       Additional Name                REMOTE CONTROL-JETT

       Brand Name                     AULDEY

       Model                          YW710710

       Additional Model &
                                      EU710710, CA710710, US710710; See items 3.1
       Model Difference:

       Date of tests                  May 11, 2016 ~ May 30, 2016

       the tests have been carried out according to the requirements of the following standards:


            FCC Part 15, Subpart C, Section 15.227


       CONCLUSION: The submitted sample was found to COMPLY with the test requirement

                             Tested by Ryan Lu                                                              Approved by Chris Chen
                    Project Engineer / EMC Department                                                      Manager / EMC Department




                                                                                                                  Date: May 30, 2016
       This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is
       permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set
       forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or
       identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the
       information that you provided to us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our
       negligence, provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue
       within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the
       report contents. Unless specific mention, the uncertainty of measurement has been explicitly taken into account to declare the compliance or
       non-compliance to the specification

                                                         No. 34, Chenwulu Section, Guantai Rd., Houjie                                       Tel: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                                                    Town, Dongguan City,                                                    Fax: +86 769 8593 1080
Dongguan Branch                                                   Guangdong 523942, China                                    Email: DGservice@cn.bureauveritas.com
                                                                              Page 1 of 22                                                              Report Version 1


                        Test Report No.:RF160506N054



                                                        TABLE OF CONTENTS
          RELEASE CONTROL RECORD ............................................................................................................ 3
          1    SUMMARY OF TEST RESULTS ..................................................................................................... 4
          2    MEASUREMENT UNCERTAINTY................................................................................................... 4
          3    GENERAL INFORMATION .............................................................................................................. 5

              3.1     GENERAL DESCRIPTION OF EUT ........................................................................................... 5
              3.2     DESCRIPTION OF TEST MODES ............................................................................................. 6
              3.3     GENERAL DESCRIPTION OF APPLIED STANDARDS ............................................................ 6
              3.4     DESCRIPTION OF SUPPORT UNITS ....................................................................................... 6

          4    TEST TYPES AND RESULTS ......................................................................................................... 7

              4.1     RADIATED EMISSION MEASUREMENT .................................................................................. 7
                 4.1.1      LIMITS OF RADIATED EMISSION MEASUREMENT ...................................................... 7
                 4.1.2      TEST INSTRUMENTS ....................................................................................................... 8
                 4.1.3      TEST PROCEDURES ..................................................................................................... 10
                 4.1.4      DEVIATION FROM TEST STANDARD ........................................................................... 10
                 4.1.5      TEST SETUP ....................................................................................................................11
                 4.1.6      EUT OPERATING CONDITIONS .................................................................................... 12
                 4.1.7      TEST RESULTS .............................................................................................................. 12
              4.2     20dB BANDWIDTH MEASUREMENT...................................................................................... 18
                    4.2.1     LIMITS OF 20dB BANDWIDTH MEASUREMENT ......................................................... 18
                    4.2.2     TEST INSTRUMENTS ................................................................................................... 18
                    4.2.3     TEST PROCEDURE ...................................................................................................... 18
                    4.2.4     DEVIATION FROM TEST STANDARD .......................................................................... 19
                    4.2.5     TEST SETUP ................................................................................................................. 19
                    4.2.6     EUT OPERATING CONDITIONS................................................................................... 19
                    4.2.7     TEST RESULTS ............................................................................................................. 20

          5    PHOTOGRAPHS OF THE TEST CONFIGURATION .................................................................... 21
          6    APPENDIX A - MODIFICATIONS RECORDERS FOR ENGINEERING CHANGES TO THE EUT
               BY THE LAB .................................................................................................................................. 22




                                                       No. 34, Chenwulu Section, Guantai Rd., Houjie                                      Tel: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                                                  Town, Dongguan City,                                                   Fax: +86 769 8593 1080
Dongguan Branch                                                 Guangdong 523942, China                                   Email: DGservice@cn.bureauveritas.com
                                                                           Page 2 of 22                                                              Report Version 1


                     Test Report No.:RF160506N054


                                      RELEASE CONTROL RECORD

           ISSUE NO.                REASON FOR CHANGE                                               DATE ISSUED
           RF160506N054             Original release                                                 May 30, 2016




                                             No. 34, Chenwulu Section, Guantai Rd., Houjie                   Tel: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                                        Town, Dongguan City,                                Fax: +86 769 8593 1080
Dongguan Branch                                       Guangdong 523942, China                Email: DGservice@cn.bureauveritas.com
                                                             Page 3 of 22                                         Report Version 1


                     Test Report No.:RF160506N054


          1 SUMMARY OF TEST RESULTS
          The EUT has been tested according to the following specifications:
                     APPLIED STANDARD: FCC PART 15, SUBPART C , SECTION 15.227(2012-10)
            STANDARD
                                    TEST TYPE AND LIMIT                 RESULT                   REMARK
             SECTION
           §15.207 (a)              Conducted Emission                     N/A           EUT is powered by battery
            §15.209
                                     Radiated Emission                    PASS                   Compliant
            §15.227
            §15.215(c)              20dB Bandwidth Test                   PASS                   Compliant



          2 MEASUREMENT UNCERTAINTY
          Where relevant, the following measurement uncertainty levels have been estimated
          for tests performed on the EUT as specified in CISPR 16-4-2:
                      MEASUREMENT                          FREQUENCY                          UNCERTAINTY
                                                           9KHz ~ 30MHz                            2.90dB
                                                           30MHz ~ 1GHz                            3.62dB
                     Radiated emissions
                                                           1GHz ~ 18GHz                            5.03dB
                                                          18GHz ~ 40GHz                            4.84dB

          This uncertainty represents an expanded uncertainty expressed at approximately the
          95% confidence level using a coverage factor of k = 2.




                                         No. 34, Chenwulu Section, Guantai Rd., Houjie                        Tel: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                                    Town, Dongguan City,                                     Fax: +86 769 8593 1080
Dongguan Branch                                   Guangdong 523942, China                     Email: DGservice@cn.bureauveritas.com
                                                         Page 4 of 22                                              Report Version 1


                     Test Report No.:RF160506N054


          3 GENERAL INFORMATION
          3.1 GENERAL DESCRIPTION OF EUT

          PRODUCT                               Fly ‘Em Fast! Jett
          ADDITIONAL NAME                       REMOTE CONTROL-JETT
          MODEL NO.                             YW710710
          ADDITIONAL MODELS                     EU710710, CA710710, US710710
          FCC ID                                2AIRPYW710710
          NOMINAL VOLTAGE                       DC 3V(2*AAA*1.5V) from Battery
          MODULATION TYPE                       ASK
          OPERATING FREQUENCY                   27.145MHz
          NUMBER OF CHANNEL                     1
          ANTENNA TYPE                          Wire Antenna with 0dBi gain
          I/O PORTS                             Refer to user’s manual

          NOTE:
          1.   For a more detailed features description, please refer to the manufacturer’s specifications or the
               user's manual.

          2.   For the test results, the EUT had been tested with all conditions, but only the worst case was
               shown in test report.

          3.   Please refer to the EUT photo document (Reference No.: 160506N054) for detailed product photo.
          4.   Additional models EU710710, CA710710, US710710 are identical with the test model YW710710,
               except the export country and model no. for trading purpose.




                                          No. 34, Chenwulu Section, Guantai Rd., Houjie                   Tel: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                                     Town, Dongguan City,                                Fax: +86 769 8593 1080
Dongguan Branch                                    Guangdong 523942, China                Email: DGservice@cn.bureauveritas.com
                                                          Page 5 of 22                                         Report Version 1


                     Test Report No.:RF160506N054


          3.2 DESCRIPTION OF TEST MODES
          The EUT was tested under the following mode.


                                FREQUENCY                       TEST MODES
                                    27.145 MHz                    Transmitting

          3.3 GENERAL DESCRIPTION OF APPLIED STANDARDS


           The EUT is a RF Product. According to the specifications of the manufacturer, it
           must comply with the requirements of the following standards:

           FCC Part 15, Subpart C, 15.227
           ANSI C63.10-2013

           All test items have been performed and recorded as per the above standards.



          3.4 DESCRIPTION OF SUPPORT UNITS

             The EUT has been tested as an independent unit without any other necessary
             accessories or support units.




                                           No. 34, Chenwulu Section, Guantai Rd., Houjie                   Tel: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                                      Town, Dongguan City,                                Fax: +86 769 8593 1080
Dongguan Branch                                     Guangdong 523942, China                Email: DGservice@cn.bureauveritas.com
                                                           Page 6 of 22                                         Report Version 1


                     Test Report No.:RF160506N054


          4      TEST TYPES AND RESULTS

          4.1 RADIATED EMISSION MEASUREMENT

          4.1.1 LIMITS OF RADIATED EMISSION MEASUREMENT

              Emissions radiated outside of the specified bands, shall be according to the
              general radiated limits in 15.209 as following:
                     FREQUENCIES                 FIELD STRENGTH                   MEASUREMENT DISTANCE
                        (MHz)                    (microvolts/meter)                     (meters)
                      0.009 ~ 0.490                   2400/F(kHz)                            300
                      0.490 ~ 1.705                  24000/F(kHz)                             30
                       1.705 ~ 30.0                         30                                30
                          30 ~ 88                           100                                3
                         88 ~ 216                           150                                3
                        216 ~ 960                           200                                3
                        Above 960                           500                                3


              According to §15.227(a), the field strength of emissions from intentional radiators
              operated within these frequency bands shall comply with the following:
                                                 Field Strength of                        Field Strength of
               Frequency Range of
                                              Fundamental Emission                     Fundamental Emission
                  Fundamental
                                                      [Peak]                                  [Average]
                     [MHz]
                                                       µV/m]
                                                      [µ                                         µV/m]
                                                                                                [µ
                   26.96 – 27.28               100,000 (100 dBµV/m)                      10,000 (80 dBµV/m)
               NOTE:
               1. The lower limit shall apply at the transition frequencies.
               2. Emission level (dBuV/m) = 20 log Emission level (uV/m).
               3. As shown in 15.35(b), for frequencies above 1000MHz, the field strength limits are based on
                  average detector, however, the peak field strength of any emission shall not exceed the
                  maximum permitted average limits, specified above by more than 20dB under any condition of
                  modulation.




                                            No. 34, Chenwulu Section, Guantai Rd., Houjie                    Tel: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                                       Town, Dongguan City,                                 Fax: +86 769 8593 1080
Dongguan Branch                                      Guangdong 523942, China                 Email: DGservice@cn.bureauveritas.com
                                                            Page 7 of 22                                          Report Version 1


                     Test Report No.:RF160506N054


          4.1.2 TEST INSTRUMENTS

                Below 30MHz
            Equipment               Manufacturer          Model No.           Serial No.      Last Cal.      Next Cal.
            Spectrum Analyzer       Agilent               E4446A              MY46180622 Nov. 25,15          Nov. 24,16
            Spectrum Analyzer
                                    Rohde&Schwarz FSV40                       101003          Nov. 25,15     Nov. 24,16
            (10Hz–40GHz)
            Signal Analyzer         Rohde&Schwarz FSV7                        102331          Nov. 25,15     Nov. 24,16
            EMI Test Receiver       Rohde&Schwarz ESVS10                      841431/004      Nov. 25,15     Nov. 24,16
            Loop antenna
                                    Daze                  ZN30900A            0708            Dec. 05,15     Dec. 05,16
            (9kHz~30MHz)
            Bilog Antenna           Teseq                 CBL 6111D           27089           Jun. 27, 15    Jun. 26, 16
            Horn Antenna
                                    ETS -Lindgren         3117                00062558        Oct. 18, 15    Oct. 17, 16
            (1GHz -18GHz)
            Amplifier
                                    SONOMA                310D                186955          Nov. 25,15     Nov. 24,16
            (9kHz-1GHz)
            Pre-Amplifier
                                    Agilent               8449B               3008A00409      Nov. 25,15     Nov. 24,16
            (100MHz-26.5GHz)
            Digital Multimeter      FLUKE                 15B           A1220010DG Oct. 30, 15               Oct. 29, 16
            10m Semi-anechoic                             21.4m*12.1m*8
                                    CHANGLING                           NSEMC006   Nov. 25,15                Nov. 24,16
            Chamber                                       .8m
                                                          ADT_Radiated
            Test Software           ADT                                 N/A        N/A                       N/A
                                                          _V7.6.15.9.2


                NOTE: 1. The calibration interval of the above test instruments is 12 months or 24 months and
                            the calibrations are traceable to CEPREI/CHINA, GRGT/CHINA and NIM/CHINA.
                         2. The test was performed in 10m Chamber
                         3. The FCC Site Registration No. is 502831.




                                              No. 34, Chenwulu Section, Guantai Rd., Houjie                      Tel: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                                         Town, Dongguan City,                                   Fax: +86 769 8593 1080
Dongguan Branch                                        Guangdong 523942, China                   Email: DGservice@cn.bureauveritas.com
                                                              Page 8 of 22                                            Report Version 1


                     Test Report No.:RF160506N054



                Below 1G
             Equipment              Manufacturer      Model No.           Serial No.      Last Cal.      Next Cal.
             EMI Test Receiver      Rohde&SchwarzESR7                     101494          Apr. 05,16     Apr. 04,17
             Signal and Spectrum    Rohde&Schwar
                                                 FSV40                    101003          Apr. 05,16     Apr. 04,17
             Analyzer               z
             Bilog Antenna          Teseq        CBL 6111D                30643           Jul. 16, 15    Jul. 15, 16
             Horn Antenna
                                    ETS -Lindgren 3117                    00062558        May 30, 14     May 29, 16
             (1GHz -18GHz)
             GPS Generator+
                                    TOJOIN            GNSS-5000A          E1-010119       Aug. 08, 14    Aug. 07, 16
             Antenna
             3m Semi-anechoic       ETS-LINDGRE
                                                9m*6m*6m     NSEMC003    Mar. 12,16                      Mar. 11,18
             Chamber                N
                                                ADT_Radiated
             Test Software          ADT                      N/A         N/A                             N/A
                                                _V7.6.15.9.2
                                    SCHWARZBEC
             Horn Antenna                       BBHA 9170    BBHA9170242 Mar. 12,16                      Mar. 11,17
                                    K
             Amplifier
                                  SONOMA              310D                186955          Mar. 04,16     Mar. 03, 17
             (9kHz-1GHz)
             Pre-Amplifier(1-18G) HP                  8449B               3008A00409      Apr. 25,16     Apr. 24,17
             Pre-Amplifier
                                  EMCI                EMC 184045          980102          Nov. 20,15     Nov. 19,16
             (18GHz-40GHz)
                                                      ADT_Radiated
             Test Software          ADT                            N/A                    N/A            N/A
                                                      _V7.6.15.9.2
             BLUETOOTH              Rohde&Schwar
                                                 CBT32                    100811          Sep. 01,15     Aug. 31,16
             TESTER                 z


                NOTE:
                1. The test was performed in 966 Chamber.
                2. The calibration interval of the above test instruments are 12, 24 or 36 months and the
                calibrations are traceable to CEPREI/CHINA, GRGT/CHINA and NIM/CHINA.
                3. The horn antenna is used only for the measurement of emission frequency above1GHz if
                tested.
                4. The FCC Site Registration No. is 494399.




                                          No. 34, Chenwulu Section, Guantai Rd., Houjie                      Tel: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                                     Town, Dongguan City,                                   Fax: +86 769 8593 1080
Dongguan Branch                                    Guangdong 523942, China                   Email: DGservice@cn.bureauveritas.com
                                                          Page 9 of 22                                            Report Version 1


                     Test Report No.:RF160506N054


          4.1.3 TEST PROCEDURES

          The basic test procedure was in accordance with ANSI C63.4 (section 12).

           a. The EUT was placed on the top of a rotating table 1.5 meters above the
              ground at a chamber room. The table was rotated 360 degrees to determine
              the position of the highest radiation.
           b. The EUT was set 3 meters away from the interference-receiving antenna,
              which was mounted on the top of a variable-height antenna tower.
           c. The height of antenna is varied from one meter to four meters above the
              ground to determine the maximum value of the field strength. Both horizontal
              and vertical polarizations of the antenna are set to make the measurement.
           d. For each suspected emission, the EUT was arranged to its worst case and
              then the antenna was tuned to heights from 1 meter to 4 meters and the
              rotatable table was turned from 0 degrees to 360 degrees to find the
              maximum reading.
           e. The test-receiver system was set to quasi-peak detect function and specified
              bandwidth with maximum hold mode when the test frequency is below 1 GHz.
           f. During the test, each emission was maximized by: having the EUT
              continuously working, investigated all operating modes, rotated about all 3 axis
              (X, Y & Z) and considered typical configuration to obtain worst position,
              manipulating interconnecting cables, For battery operated equipment, the
              equipment tests shall be perform using new battery. The turntable was rotated
              to maximize the emission level.
           g. For below 30MHz, a loop antenna with its vertical plane is place 3m from the
              EUT and rotated about its vertical axis for maximum response at each azimuth
              about the EUT. And the centre of the loop shall be 1m above the ground.
           NOTE:

            1. The resolution bandwidth of test receiver/spectrum analyzer is 120kHz for Quasi-peak detection
               (QP) at frequency below 1GHz.
            2. Emission level(dBuV/m)=Raw Value(dBuV) + Correction Factor(dB/m)
            3. Correction Factor(dB/m) = Antenna Factor (dB/m) + Cable Factor (dB)
            4. Margin value = Emission level – Limit value.
            5. Fundamental AV value =PK Emission +duty cycle.


          4.1.4 DEVIATION FROM TEST STANDARD

           No deviation.

                                         No. 34, Chenwulu Section, Guantai Rd., Houjie                   Tel: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                                    Town, Dongguan City,                                Fax: +86 769 8593 1080
Dongguan Branch                                   Guangdong 523942, China                Email: DGservice@cn.bureauveritas.com
                                                        Page 10 of 22                                         Report Version 1


                     Test Report No.:RF160506N054


          4.1.5 TEST SETUP
          Below 30MHz




          30MHz~1GHz



                                                                    Ant. Tower
                                                                                         1-4m
                                                   3m
                                EUT

                                            Turn Table

                         1.5m


                                                  Ground Plane

                                                 Spectrum




          For the actual test configuration, please refer to the attached file (Test Setup Photo).



                                       No. 34, Chenwulu Section, Guantai Rd., Houjie                   Tel: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                                  Town, Dongguan City,                                Fax: +86 769 8593 1080
Dongguan Branch                                 Guangdong 523942, China                Email: DGservice@cn.bureauveritas.com
                                                      Page 11 of 22                                         Report Version 1


                      Test Report No.:RF160506N054

          4.1.6 EUT OPERATING CONDITIONS


                a. Turned on the power of equipment.
                b. Hold down the TX of button, then the EUT was operating.
                c. EUT was operated according to the type used was description in
                      manufacturer’s specifications or the User's Manual.

          4.1.7 TEST RESULTS

             FIELD STRENGTH OF FUNDAMENTAL


             ANTENNA POLARITY: 0°
                                       Correction         Raw            Emission
                            Freq.                                                             Limit         Margin
                No.                     Factor            Value            Level
                           (MHz)                                                            (dBuV/m)         (dB)
                                        (dB/m)           (dBuV)          (dBuV/m)
                 *       27.14(PK)       -10.17           77.38             67.21             100           -32.79
                 *       27.14(AV)       -10.01             -               57.20             80            -22.80


             ANTENNA POLARITY: 90°
                                       Correction         Raw            Emission
                            Freq.                                                             Limit         Margin
                No.                     Factor            Value            Level
                           (MHz)                                                            (dBuV/m)         (dB)
                                        (dB/m)           (dBuV)          (dBuV/m)
                 *       27.14(PK)       -10.17           84.30             74.13             100           -25.87
                 *       27.14(AV)       -10.01             -               64.12             80            -15.88

              REMARKS: 1. Emission level (dBuV/m) = Raw Value (dBuV) + Correction Factor (dB/m).
                            2. Correction Factor (dB/m) = Antenna Factor (dB/m) + Cable Factor (dB).
                            3. The other emission levels were very low against the limit.
                            4. Margin value = Emission level – Limit value.
                            5. “ * “: Fundamental frequency.
                            6. The average value of fundamental frequency is: Average value = Peak value +AV
                                factor, where the AV factor is calculated from following formula: AV factor=20 log
                                (Duty cycle) = 20 log (31.58%) = -10.01dB, Please see page 12~13 for plotted duty.




                                            No. 34, Chenwulu Section, Guantai Rd., Houjie                        Tel: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                                       Town, Dongguan City,                                     Fax: +86 769 8593 1080
Dongguan Branch                                      Guangdong 523942, China                     Email: DGservice@cn.bureauveritas.com
                                                           Page 12 of 22                                              Report Version 1


                     Test Report No.:RF160506N054


          Duty Cycle:

                 Tp = 65.136ms

                 Ton = Ton1 * Number+ Ton2 * Number+ Ton3 * Number
                     =0.4522*11 +1.2696 *7+6.7072 *1
                       = 20.5686ms

                 Duty Cycle = Ton / Tp * 100% = 20.5686/65.136= 31.58%


          Tp=65.136ms




                                       No. 34, Chenwulu Section, Guantai Rd., Houjie                   Tel: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                                  Town, Dongguan City,                                Fax: +86 769 8593 1080
Dongguan Branch                                 Guangdong 523942, China                Email: DGservice@cn.bureauveritas.com
                                                      Page 13 of 22                                         Report Version 1


                     Test Report No.:RF160506N054


          Ton1=0.4522ms




          Ton2= 1.2696ms




                                       No. 34, Chenwulu Section, Guantai Rd., Houjie                   Tel: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                                  Town, Dongguan City,                                Fax: +86 769 8593 1080
Dongguan Branch                                 Guangdong 523942, China                Email: DGservice@cn.bureauveritas.com
                                                      Page 14 of 22                                         Report Version 1


                     Test Report No.:RF160506N054



          Ton3= 6.7072ms




                                       No. 34, Chenwulu Section, Guantai Rd., Houjie                   Tel: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                                  Town, Dongguan City,                                Fax: +86 769 8593 1080
Dongguan Branch                                 Guangdong 523942, China                Email: DGservice@cn.bureauveritas.com
                                                      Page 15 of 22                                         Report Version 1


                     Test Report No.:RF160506N054



                                                                        DETECTOR
          FREQUENCY RANGE                   30MHz ~ 1GHz                                             Quasi-Peak (QP)
                                                                        FUNCTION


                             ANTENNA POLARITY & TEST DISTANCE: HORIZONTAL AT 3 M
                              EMISSION                                     ANTENNA         TABLE         RAW       CORRECTION
                   FREQ.                         LIMIT       MARGIN
          NO.                  LEVEL                                        HEIGHT         ANGLE        VALUE        FACTOR
                   (MHz)                       (dBuV/m)       (dB)
                              (dBuV/m)                                       (cm)         (Degree)      (dBuV)        (dB/m)
            1      53.90            15.03        40.00         -24.97          200              0        38.40        -23.37
            2      107.32           15.94        43.50         -27.56          200              0        34.79        -18.85
            3      135.43           15.56        43.50         -27.94          200              0        33.16        -17.60
            4      190.26           15.66        43.50         -27.84          200              0        35.72        -20.06
            5      380.04           19.04        46.00         -26.96          200              0        30.67        -11.63
            6      461.58           21.50        46.00         -24.50          200              0        30.41         -8.91
          REMARKS:
                 1. Emission level (dBuV/m) = Raw Value (dBuV) + Correction Factor (dB/m).
                 2. Correction Factor (dB/m) = Antenna Factor (dB/m) + Cable Factor (dB).
                 3. The other emission levels were very low against the limit.
                 4. Margin value = Emission level – Limit value.




                                                No. 34, Chenwulu Section, Guantai Rd., Houjie                        Tel: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                                           Town, Dongguan City,                                     Fax: +86 769 8593 1080
Dongguan Branch                                          Guangdong 523942, China                     Email: DGservice@cn.bureauveritas.com
                                                               Page 16 of 22                                              Report Version 1


                     Test Report No.:RF160506N054



                                                                        DETECTOR
          FREQUENCY RANGE                   30MHz ~ 1GHz                                             Quasi-Peak (QP)
                                                                        FUNCTION


                               ANTENNA POLARITY & TEST DISTANCE: VERTICAL AT 3 M
                              EMISSION                                     ANTENNA         TABLE         RAW       CORRECTION
                   FREQ.                         LIMIT       MARGIN
          NO.                  LEVEL                                        HEIGHT         ANGLE        VALUE        FACTOR
                   (MHz)                       (dBuV/m)       (dB)
                              (dBuV/m)                                       (cm)         (Degree)      (dBuV)        (dB/m)
            1      53.90            26.48        40.00         -13.52          100              0        49.85        -23.37
            2      80.61            22.71        40.00         -17.29          100              0        45.74        -23.03
            3      107.32           24.95        43.50         -18.55          100              0        43.80        -18.85
            4      135.43           24.42        43.50         -19.08          100              0        42.02        -17.60
            5      162.14           19.97        43.50         -23.53          100              0        38.64        -18.67
            6      190.26           17.59        43.50         -25.91          100              0        37.65        -20.06
          REMARKS:
                 1. Emission level (dBuV/m) = Raw Value (dBuV) + Correction Factor (dB/m).
                 2. Correction Factor (dB/m) = Antenna Factor (dB/m) + Cable Factor (dB).
                 3. The other emission levels were very low against the limit.
                 4. Margin value = Emission level – Limit value.




                                                No. 34, Chenwulu Section, Guantai Rd., Houjie                        Tel: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                                           Town, Dongguan City,                                     Fax: +86 769 8593 1080
Dongguan Branch                                          Guangdong 523942, China                     Email: DGservice@cn.bureauveritas.com
                                                               Page 17 of 22                                              Report Version 1


                     Test Report No.:RF160506N054


          4.2     BANDWIDTH MEASUREMENT
          4.2.1 LIMITS OF BANDWIDTH MEASUREMENT
          The field strength of any emissions appearing between the band edges and out of band shall
          be attenuated at least 20 dB below the level of the unmodulated carrier or to the general limits
          in Section 15.209.


                       FREQUENCY                              Limits
                          (MHz)                                [MHz]
                         27.145                         within 26.96-27.28



          4.2.2 TEST INSTRUMENTS

          Equipment                 Manufacturer          Model No.       Serial No.          Last Cal.     Next Cal.
          Power Sensor              Keysight              U2021XA         MY55060016 Oct. 12, 15            Oct.11, 16
          Power Sensor              Keysight              U2021XA         MY55060018 Oct. 12, 15            Oct.11, 16
          Digital Multimeter        FLUKE                 15B             A1220010DG Oct. 12, 15            Oct.11, 16
          Humid & Temp
                                    Haida                 HD-2257         110807201           Sep.07,15     Sep. 06,16
          Programmable Tester
          Oscilloscope              Agilent         DSO9254A MY51260160 Nov. 28,15                          Nov. 27,16
          Signal Analyzer           Rohde & Schwarz FSV7     102331     Nov. 09,15                          Nov. 08,16
          Signal Generator          Agilent               N5183A           MY50140980 Nov. 09,15            Nov. 08,16
          ESG Vector Signal
                                    Agilent               E4438C           MY49072505 Apr. 22, 16           Apr. 21, 17
          Generator
          BLUETOOTH
                                    Rohde&Schwarz CBT32                   100811              Sep. 01,15    Aug. 31,16
          TESTER
          NOTE:
             1. The test was performed in RF Oven room.
             2. The calibration interval of the above test instruments is 12 months and the calibrations are
                traceable to CEPREI/CHINA, GRGT/CHINA and NIM/CHINA.




                                              No. 34, Chenwulu Section, Guantai Rd., Houjie                        Tel: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                                         Town, Dongguan City,                                     Fax: +86 769 8593 1080
Dongguan Branch                                        Guangdong 523942, China                     Email: DGservice@cn.bureauveritas.com
                                                             Page 18 of 22                                               Report Version 1


                     Test Report No.:RF160506N054


          4.2.3 TEST PROCEDURE

            a. Check the calibration of the measuring instrument using either an internal
               calibrator or a known signal from an external generator.
            b. Turn on the EUT and connect it to measurement instrument. Then set it to any
               one convenient frequency within its operating range. Set a reference level on the
               measuring instrument equal to the highest peak value.
            c. Measure the frequency difference of two frequencies that were attenuated 20dB
               from the reference level. Record the frequency difference as the emission
               bandwidth.
            d. Repeat above procedures until all frequencies measured were complete.


          4.2.4 DEVIATION FROM TEST STANDARD

           No deviation.



          4.2.5 TEST SETUP



                          EUT                                               SPECTRUM

                                          10dB ATTENUATION PAD              ANALYZER




          4.2.6 EUT OPERATING CONDITIONS
                   Same as item 4.1.6




                                        No. 34, Chenwulu Section, Guantai Rd., Houjie                   Tel: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                                   Town, Dongguan City,                                Fax: +86 769 8593 1080
Dongguan Branch                                  Guangdong 523942, China                Email: DGservice@cn.bureauveritas.com
                                                       Page 19 of 22                                         Report Version 1


                     Test Report No.:RF160506N054


          4.2.7 TEST RESULTS


                  Lower & Upper Test Frequency Point              Test Frequency
                                                                                              P/F
                                (MHz)                                  (MHz)
                                Lower                                  26.96                PASS
                                Upper                                  27.28                PASS

           Test Data:




                                       No. 34, Chenwulu Section, Guantai Rd., Houjie                   Tel: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                                  Town, Dongguan City,                                Fax: +86 769 8593 1080
Dongguan Branch                                 Guangdong 523942, China                Email: DGservice@cn.bureauveritas.com
                                                      Page 20 of 22                                         Report Version 1


                     Test Report No.:RF160506N054


          5     PHOTOGRAPHS OF THE TEST CONFIGURATION

           Please refer to the attached file (Test Setup Photo).




                                       No. 34, Chenwulu Section, Guantai Rd., Houjie                   Tel: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                                  Town, Dongguan City,                                Fax: +86 769 8593 1080
Dongguan Branch                                 Guangdong 523942, China                Email: DGservice@cn.bureauveritas.com
                                                      Page 21 of 22                                         Report Version 1


                     Test Report No.:RF160506N054


          6     APPENDIX A - MODIFICATIONS RECORDERS FOR
                ENGINEERING CHANGES TO THE EUT BY THE LAB


           No any modifications are made to the EUT by the lab during the test.




           ---END---




                                       No. 34, Chenwulu Section, Guantai Rd., Houjie                   Tel: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                                  Town, Dongguan City,                                Fax: +86 769 8593 1080
Dongguan Branch                                 Guangdong 523942, China                Email: DGservice@cn.bureauveritas.com
                                                      Page 22 of 22                                         Report Version 1



Document Created: 2016-06-22 14:23:06
Document Modified: 2016-06-22 14:23:06

© 2024 FCC.report