FCC Part 15.407(Wi-Fi B1&2&3&4) Report_Part 1

FCC ID: 2AIMRMITVMDZ22AB

Test Report

Download: PDF
FCCID_3904528

   Uni#nTrust
              @l
               J
                                                                Page 1 of 102                           Report No.: 180320001RFC—4




                                         FCC TEST REPORT


                                                  Product Name:              MI BOX
                                                       Trade Mark:           MI
                                                        Model No.:           MDZ—22—AB
                                                Report Number:               180320001RFC—4
                                                Test Standards:              FCC 47 CFR Part 15 Subpart E
                                                              FCC ID:        2AIMRMITVMDZ22AB
                                                      Test Result:           PASS
                                                   Date of Issue:            June 22, 2018



                                                                    Prepared for:

                                           Beijing Xiaomi Electronics Co.,Ltd
           Room 707,7F,Building 5,No 58,JinghaiWulu Road Beijing economic
                          & Technological Development Zone, Beijing, China


                                                                    Prepared by:
                  Shenzhen UnionTrust Quality and Technology Co., Ltd.
            16/F, Block A, Building 6, Baoneng Science and Technology Park,
              Qingxiang Road No.1, Longhua New District, Shenzhen, China
                                                    TEL: +86—755—2823 0888
                                                    FAX: +86—755—2823 0886




                    Tested by:                 —~]_|a
                                                 Ht‘enry L
                                                                                    Reviewed by:                     Jz
                                                                                                                   miang
                                             Project,    Engineer                                              Assistant Manager

                                                         |
                Approved by:                                                                  Date:
                                                   Billy Li
                                            Technical Director


Shenzhen UnionTrust Quality and Technology Co., Ltd.
Address: 16/F, Block A, Building 6, Baoneng Science and Technology Park, Qingxiang Road No.1, Longhua New District, Shenzhen, China
Tel: +86—755—28230888                  Fax: +86—755—28230886                  E—mail: info@uttlab.com                Http://www.uttlab.com


                                                               Page 2 of 102                          Report No.: 180320001RFC-4

Version
       Version No.                         Date                                                   Description
            V1.0                     June 22, 2018                                                   Original




Shenzhen UnionTrust Quality and Technology Co., Ltd.
Address: 16/F, Block A, Building 6, Baoneng Science and Technology Park, Qingxiang Road No.1, Longhua New District, Shenzhen, China
Tel: +86-755-28230888                  Fax: +86-755-28230886                  E-mail: info@uttlab.com               Http://www.uttlab.com


                                                                         Page 3 of 102                                  Report No.: 180320001RFC-4



                                                                        CONTENTS
1.   GENERAL INFORMATION ....................................................................................................................................... 4
     1.1  CLIENT INFORMATION ........................................................................................................................................ 4
     1.2  EUT INFORMATION ............................................................................................................................................ 4
          1.2.1 GENERAL DESCRIPTION OF EUT ............................................................................................................ 4
          1.2.2 DESCRIPTION OF ACCESSORIES.............................................................................................................. 4
     1.3 PRODUCT SPECIFICATION SUBJECTIVE TO THIS STANDARD ................................................................................. 5
     1.4 OTHER INFORMATION ......................................................................................................................................... 6
     1.5 DESCRIPTION OF SUPPORT UNITS ...................................................................................................................... 6
     1.6 TEST LOCATION ................................................................................................................................................. 6
     1.7 TEST FACILITY ................................................................................................................................................... 6
     1.8 DEVIATION FROM STANDARDS ............................................................................................................................ 7
     1.9 ABNORMALITIES FROM STANDARD CONDITIONS .................................................................................................. 7
     1.10 OTHER INFORMATION REQUESTED BY THE CUSTOMER ........................................................................................ 7
     1.11 MEASUREMENT UNCERTAINTY ........................................................................................................................... 7
2.   TEST SUMMARY ...................................................................................................................................................... 8
3.   EQUIPMENT LIST .................................................................................................................................................... 9
4.   TEST CONFIGURATION ........................................................................................................................................ 10
     4.1      ENVIRONMENTAL CONDITIONS FOR TESTING ...................................................................................................... 10
              4.1.1 NORMAL OR EXTREME TEST CONDITIONS ............................................................................................. 10
     4.2      TEST CHANNELS ............................................................................................................................................. 10
     4.3      EUT TEST STATUS .......................................................................................................................................... 11
     4.4      PRE-SCAN ....................................................................................................................................................... 11
     4.5      TEST SETUP .................................................................................................................................................... 11
              4.5.1 FOR RADIATED EMISSIONS TEST SETUP ................................................................................................ 11
              4.5.2 FOR CONDUCTED EMISSIONS TEST SETUP ............................................................................................ 13
              4.5.3 FOR CONDUCTED RF TEST SETUP ........................................................................................................ 13
     4.6      SYSTEM TEST CONFIGURATION ........................................................................................................................ 14
     4.7      DUTY CYCLE ................................................................................................................................................... 15
5.   RADIO TECHNICAL REQUIREMENTS SPECIFICATION .................................................................................... 18
     5.1      REFERENCE DOCUMENTS FOR TESTING ............................................................................................................ 18
     5.2      ANTENNA REQUIREMENT ................................................................................................................................. 18
     5.3      26 DB BANDWIDTH .......................................................................................................................................... 19
     5.4      6 DB BANDWIDTH ............................................................................................................................................ 26
     5.5      M AXIMUM CONDUCTED OUTPUT POWER ............................................................................................................ 29
     5.6      PEAK POWER SPECTRAL DENSITY ................................................................................................................... 33
     5.7      FREQUENCY STABILITY .................................................................................................................................... 45
     5.8      RADIATED EMISSIONS AND BAND EDGE MEASUREMENT .................................................................................... 48
     5.9      DYNAMIC FREQUENCY SELECTION ................................................................................................................... 89
     5.10     AC POWER LINE CONDUCTED EMISSION .......................................................................................................... 99
APPENDIX 1 PHOTOS OF TEST SETUP ................................................................................................................... 102
APPENDIX 2 PHOTOS OF EUT CONSTRUCTIONAL DETAILS ............................................................................... 102




Shenzhen UnionTrust Quality and Technology Co., Ltd.
Address: 16/F, Block A, Building 6, Baoneng Science and Technology Park, Qingxiang Road No.1, Longhua New District, Shenzhen, China
Tel: +86-755-28230888                  Fax: +86-755-28230886                  E-mail: info@uttlab.com               Http://www.uttlab.com


                                                               Page 4 of 102                          Report No.: 180320001RFC-4

1. GENERAL INFORMATION
   1.1 CLIENT INFORMATION
         Applicant:                             Beijing Xiaomi Electronics Co.,Ltd
                                                Room 707,7F,Building 5,No 58,JinghaiWulu Road Beijing economic &
         Address of Applicant:
                                                Technological Development Zone, Beijing, China
         Manufacturer:                          Beijing Xiaomi Electronics Co.,Ltd
                                                Room 707,7F,Building 5,No 58,JinghaiWulu Road Beijing economic &
         Address of Manufacturer:
                                                Technological Development Zone, Beijing, China


      1.2 EUT INFORMATION
      1.2.1       General Description of EUT
         Product Name:                          MI BOX
         Model No.:                             MDZ-22-AB
         Add. Model No.:                        MDZ-22-AC, MDZ-22-AD, MDZ-22-AE, MDZ-22-AF (See Note 1)
         Trade Mark:                            MI
         DUT Stage:                             Identical Prototype
                                                                              IEEE 802.11b/g/n
                                                2.4 GHz ISM Band:
                                                                              Bluetooth: V4.0
                                                                              IEEE 802.11a/n/ac                  5 180 MHz to 5 240 MHz
         EUT Supports Function:
                                                                              IEEE 802.11a/n/ac                  5 260 MHz to 5 320 MHz
                                                5 GHz U-NII Bands:
                                                                              IEEE 802.11a/n/ac                  5 500 MHz to 5 700 MHz
                                                                              IEEE 802.11a/n/ac                  5 745 MHz to 5 825 MHz
         Sample Received Date:       May 9, 2018
         Sample Tested Date:         May 18, 2018 to May 30, 2018
         Note 1: The additional model MDZ-22-AC, MDZ-22-AD, MDZ-22-AE, MDZ-22-AF is identical with the test
         model MDZ-22-AB except the model number for marketing purpose.

      1.2.2       Description of Accessories
                                                                         Adapter
         Trade Mark:                            MI
         Model No.:                             AY11BA-AF0522102
         Input:                                 100-240 V~50/60 Hz 0.5 A
         Output:                                5.2 V   2.1 A
         AC Cable:                              N/A
         DC Cable:                              1.05 Meter

                                                                      HDMI Cable
         Description:                           HDMI Cable
         Cable Type:                            Shielded without ferrite
         Length:                                1.05 Meter




Shenzhen UnionTrust Quality and Technology Co., Ltd.
Address: 16/F, Block A, Building 6, Baoneng Science and Technology Park, Qingxiang Road No.1, Longhua New District, Shenzhen, China
Tel: +86-755-28230888                  Fax: +86-755-28230886                  E-mail: info@uttlab.com               Http://www.uttlab.com


                                                               Page 5 of 102                          Report No.: 180320001RFC-4

      1.3 PRODUCT SPECIFICATION SUBJECTIVE TO THIS STANDARD
                                                5150 MHz to 5250 MHz
         Operational          Frequency         5250 MHz to 5350 MHz
         Band:                                  5470 MHz to 5725 MHz
                                                5 725 MHz to 5 850 MHz
         Support Standards:                     IEEE 802.11a/n/ac
         TPC Function:                          Not Support
         DFS Operational mode:                  Slave without radar Interference detection function
                                                IEEE 802.11a: OFDM(64QAM, 16QAM, QPSK, BPSK)
         Type of Modulation:                    IEEE 802.11n: OFDM(64QAM, 16QAM, QPSK, BPSK)
                                                IEEE 802.11ac: OFDM(256QAM, 64QAM, 16QAM, QPSK, BPSK)
                                                IEEE 802.11a/n-HT20/ac-VHT20: 20 MHz
         Channel Spacing:                       IEEE 802.11n-HT40/ac-VHT40: 40 MHz
                                                IEEE 802.11ac-VHT80: 80 MHz
                                                IEEE 802.11a: Up to 54 Mbps
                                                IEEE 802.11n-HT20: Up to MCS7
                                                IEEE 802.11n-HT40: Up to MCS7
         Data Rate:
                                                IEEE 802.11ac-VHT20: Up to MCS8
                                                IEEE 802.11ac-VHT40: Up to MCS9
                                                IEEE 802.11ac-VHT80: Up to MCS9
                                                5150 MHz to 5250 MHz:
                                                       4 for IEEE 802.11a/n-HT20/ac-VHT20
                                                       2 for IEEE 802.11n-HT40) /ac-VHT40
                                                       1 for IEEE 802.11acVHT80
                                                5250 MHz to 5350 MHz:
                                                       4 for IEEE 802.11a/n-HT20/ac-VHT20
                                                       2 for IEEE 802.11n-HT40)/ac-VHT40
                                                       1 for IEEE 802.11acVHT80
         Number of Channels:
                                                5470 MHz to 5725 MHz:
                                                       11 for IEEE 802.11a/n-HT20/ac-VHT20
                                                       5 for IEEE 802.11n-HT40/ac-VHT40
                                                       2 for IEEE 802.11ac-VHT80
                                                5725 MHz to 5850 MHz:
                                                       5 for IEEE 802.11a/n-HT20/ac-VHT20
                                                       2 for IEEE 802.11n-HT40/ac-VHT40
                                                       1 for IEEE 802.11ac-VHT80
         Antenna Type:                          PCB Antenna
                                                5150 MHz to 5250 MHz            1.9 dBi
                                                5250 MHz to 5350 MHz            1.9 dBi
         Antenna Gain:
                                                5470 MHz to 5725 MHz            1.9 dBi
                                                5725 MHz to 5850 MHz            1.9 dBi
                                                       Mode                       U-NII-1          U-NII-2A          U-NII-2C           U-NII-3
                                                IEEE 802.11a                        12.64             13.21            11.74                11.64
         Maximum EIRP (dBm):                    IEEE 802.11n-HT20                   11.75             11.75            11.67                10.78
                                                IEEE 802.11n-HT40                   7.98              7.95              7.69                7.79
                                                IEEE 802.11ac-VHT80                 8.38              8.62              8.59                8.47
         Normal Test Voltage:                   120V~60Hz
         Extreme Test Voltage:                  102 to 138 Vac


Shenzhen UnionTrust Quality and Technology Co., Ltd.
Address: 16/F, Block A, Building 6, Baoneng Science and Technology Park, Qingxiang Road No.1, Longhua New District, Shenzhen, China
Tel: +86-755-28230888                  Fax: +86-755-28230886                  E-mail: info@uttlab.com               Http://www.uttlab.com


                                                               Page 6 of 102                          Report No.: 180320001RFC-4

         Extreme Test
                                                -10 °C to +45 °C
         Temperature:


      1.4 OTHER INFORMATION
                                                   Operation Frequency Each of Channel
                                                 U-NII-1          U-NII-2A         U-NII-2C                                       U-NII-3
         IEEE 802.11a,                                                                                                        f = 5000 + 5k,
                                                               f = 5000 + 5k, k = 32 + 4n
         IEEE 802.11n-HT20,                                                                                                    k = 145 + 4n
         IEEE 802.11ac-VHT20                   n = 1,…, 4                n = 5,…, 8               n = 17,…, 27                  n = 1,…, 5
                                                                                                                              f = 5000 + 5k,
         IEEE 802.11n-HT40,                                    f = 5000 + 5k, k = 30 + 8n
                                                                                                                               k = 143 + 8n
         IEEE 802.11ac-VHT40
                                                n = 1, 2               n = 1,…, 5          n = 9,…, 13                            n = 1, 2
                                                               f = 5000 + 5k, k = 26 + 16n                                    f = 5000 + 5k,
         IEEE 802.11ac-VHT80
                                                  n=1                    n = 1, 2            n = 5, 6                             k = 155
         Note:
         f                        is the operating frequency (MHz);
         k                        is the operating channel.


      1.5 DESCRIPTION OF SUPPORT UNITS
       The EUT has been tested with associated equipment below.
       1) Support Equipment
            Description        Manufacturer           Model No.                                  Serial Number                 Supplied by
                Notebook                      Lenovo                       E450                   SL10G10780                    UnionTrust

       2) Support Cable
             Cable No.                    Description                  Connector                      Length                   Supplied by
                     1                   Antenna Cable                     SMA                      0.30 Meter                  UnionTrust


      1.6 TEST LOCATION


       Shenzhen UnionTrust Quality and Technology Co., Ltd.

       Address: 16/F, Block A, Building 6, Baoneng Science and Technology Park, Qingxiang Road No.1, Longhua
       New District, Shenzhen, China 518109
       Telephone: +86 (0) 755 2823 0888
       Fax: +86 (0) 755 2823 0886



      1.7 TEST FACILITY

       The test facility is recognized, certified, or accredited by the following organizations:

       CNAS-Lab Code: L9069
       The measuring equipment utilized to perform the tests documented in this report has been calibrated once a
       year or in accordance with the manufacturer's recommendations, and is traceable under the ISO/IEC/EN 17025
       to international or national standards. Equipment has been calibrated by accredited calibration laboratories.

       IC-Registration No.: 21600-1
       The 3m Semi-anechoic chamber of Shenzhen UnionTrust Quality and Technology Co., Ltd. has been registered
       by Certification and Engineering Bureau of Industry Canada for radio equipment testing with Registration No.:
Shenzhen UnionTrust Quality and Technology Co., Ltd.
Address: 16/F, Block A, Building 6, Baoneng Science and Technology Park, Qingxiang Road No.1, Longhua New District, Shenzhen, China
Tel: +86-755-28230888                  Fax: +86-755-28230886                  E-mail: info@uttlab.com               Http://www.uttlab.com


                                                               Page 7 of 102                          Report No.: 180320001RFC-4

       21600-1.

       A2LA-Lab Certificate No.: 4312.01
       Shenzhen UnionTrust Quality and Technology Co., Ltd. has been accredited by A2LA for technical competence
       in the field of electrical testing, and proved to be in compliance with ISO/IEC 17025: 2005 General
       Requirements for the Competence of Testing and Calibration Laboratories and any additional program
       requirements in the identified field of testing.

       FCC Accredited Lab.
       Designation Number: CN1194
       Test Firm Registration Number: 259480




      1.8 DEVIATION FROM STANDARDS
       None.

      1.9 ABNORMALITIES FROM STANDARD CONDITIONS
       None.
      1.10        OTHER INFORMATION REQUESTED BY THE CUSTOMER
       None.

      1.11        MEASUREMENT UNCERTAINTY
       Where relevant, the following measurement uncertainty levels have been estimated for tests performed on the
       Product as specified in CISPR 16-4-2. This uncertainty represents an expanded uncertainty expressed at
       approximately the 95% confidence level using a coverage factor of k=2.
         No.                          Item                                    Measurement Uncertainty
            1               Conducted emission 9KHz-150KHz                                                     ±3.8 dB
            2              Conducted emission 150KHz-30MHz                                                     ±3.4 dB
            3                Radiated emission 9KHz-30MHz                                                      ±4.9 dB
            4                Radiated emission 30MHz-1GHz                                                      ±4.7 dB
            5                Radiated emission 1GHz-18GHz                                                      ±5.1 dB
            6               Radiated emission 18GHz-26GHz                                                      ±5.2 dB
            7                Radiated emission 26GHz-40GHz                                                     ±5.2 dB




Shenzhen UnionTrust Quality and Technology Co., Ltd.
Address: 16/F, Block A, Building 6, Baoneng Science and Technology Park, Qingxiang Road No.1, Longhua New District, Shenzhen, China
Tel: +86-755-28230888                  Fax: +86-755-28230886                  E-mail: info@uttlab.com               Http://www.uttlab.com


                                                               Page 8 of 102                          Report No.: 180320001RFC-4

2. TEST SUMMARY
                                                FCC 47 CFR Part 15 Subpart E Test Cases
                   Test Item                      Test Requirement                    Test Method                                       Result
                                            FCC 47 CFR Part 15 Subpart C
                                                    Section 15.203
          Antenna Requirement                                                       ANSI C63.10-2013                                        PASS
                                            FCC 47 CFR Part 15 Subpart C
                                               Section 15.407(a)(1) (2)
              26 dB emission                FCC 47 CFR Part 15 Subpart E        KDB 789033 D02 v02r01
                                                                                                                                            PASS
                bandwidth                      Section 15.407 (a)(2)(5)                Section C.1
                                            FCC 47 CFR Part 15 Subpart E        KDB 789033 D02 v02r01
              6 dB bandwidth                                                                                                                PASS
                                                  Section 15.407 (e)                   Section C.2
           Maximum conducted                FCC 47 CFR Part 15 Subpart E        KDB 789033 D02 v02r01
                                                                                                                                            PASS
              output power                    Section 15.407 (a)(1)(2)(3)       Section E.3.a(Method PM)
           Peak Power Spectral              FCC 47 CFR Part 15 Subpart E        KDB 789033 D02 v02r01
                                                                                                                                            PASS
                 Density                      Section 15.407 (a)(1)(2)(3)               Section F
                                            FCC 47 CFR Part 15 Subpart E
            Frequency stability                                                     ANSI C63.10-2013                                        PASS
                                                  Section 15.407 (g)
                                            FCC 47 CFR Part 15 Subpart E
           Radiated Emissions
                                            Section 15.407 (b)(1)(2)(3)(4)(6)   KDB 789033 D02 v02r01
             and Band Edge                                                                                                                  PASS
                                            FCC 47 CFR Part 15 Subpart C      Section G.3, G.4, G.5, and G.6
              Measurement
                                                  Section 15.209/205
           Dynamic Frequency                FCC 47 CFR Part 15 Subpart E KDB 905462 D03 Client Without
                                                                                                                                            PASS
               Selection                          Section 15.407 (h)             DFS New Rules v01r02
                                            FCC 47 CFR Part 15 Subpart E
             AC Power Line                       Section 15.407 (b)(6)
                                                                                    ANSI C63.10-2013                                        PASS
           Conducted Emission               FCC 47 CFR Part 15 Subpart C
                                                    Section 15.207

       For Dynamic Frequency Selection
                          Test Case                                                                          Result
                     Channel Availability Check Time                                                          N/A1
                       U-NII Detection Bandwidth                                                              N/A1
                    Channel Closing Transmission Time                                                         PASS
                          Channel Move Time                                                                   PASS
                        DFS Detection Threshold                                                               N/A1
                        Non- Occupancy Period                                                                 N/A1
         Note:
         1) The EUT is slave, NA In this whole report not application.




Shenzhen UnionTrust Quality and Technology Co., Ltd.
Address: 16/F, Block A, Building 6, Baoneng Science and Technology Park, Qingxiang Road No.1, Longhua New District, Shenzhen, China
Tel: +86-755-28230888                  Fax: +86-755-28230886                  E-mail: info@uttlab.com               Http://www.uttlab.com


                                                               Page 9 of 102                          Report No.: 180320001RFC-4

3. EQUIPMENT LIST
                                                    Radiated Emission Test Equipment List
                                                                                Serial                        Cal. date            Cal. Due date
          Used           Equipment               Manufacturer   Model No.
                                                                               Number                       (mm dd, yyyy)         (mm dd, yyyy)
                       3M Chamber &
                                                ETS-LINDGREN               3M                N/A            Dec. 20, 2015         Dec. 19, 2018
                    Accessory Equipment
                          Receiver                     R&S              ESIB26             100114           Dec. 10, 2017         Dec. 10, 2018
                       EXA Spectrum
                                                   KEYSIGHT             N9010A         MY51440197            Dec.10, 2017         Dec. 10, 2018
                          Analyzer
                        Loop Antenna            ETS-LINDGREN              6502           00202525           Dec. 22, 2017         Dec. 22, 2018
                     Broadband Antenna          ETS-LINDGREN             3142E           00201566           Dec. 17, 2017         Dec. 17, 2018
                         Preamplifier                   HP               8447F          2805A02960          Dec. 10, 2017         Dec. 10, 2018
                       Horn Antenna             ETS-LINDGREN              3117           00164202           Dec. 17, 2017         Dec. 17, 2018
                       Horn Antenna
                                                ETS-LINDGREN            3117-PA          00201874           Dec. 17, 2017         Dec. 17, 2018
                       (Pre-amplifier)
                       Horn Antenna             ETS-LINDGREN             3116C           00200180           Dec. 17, 2017         Dec. 17, 2018
                       Horn Antenna
                                                ETS-LINDGREN           3116C-PA          00202652           Dec. 17, 2017         Dec. 17, 2018
                       (Pre-amplifier)
                        Multi device
                                                ETS-LINDGREN           7006-001          00160105                 N/A                   N/A
                         Controller
                    Band Rejection Filter
                                                  Micro-Tronics       BRM50702              G248             Jun. 21, 2017         Jun. 21, 2018
                   (2400MHz~2500MHz)
                    Band Rejection Filter
                                                  Micro-Tronics       BRM50716             G1868             Jun. 15, 2017         Jun. 15, 2018
                   (5150MHz~5880MHz)
                       Test Software                  Audix                e3                        Software Version: 9.160323


                                                      Conducted RF test Equipment List
                                                                               Serial                         Cal. date            Cal. Due date
          Used           Equipment              Manufacturer  Model No.
                                                                              Number                        (mm dd, yyyy)         (mm dd, yyyy)
                        EXA Spectrum
                                                  KEYSIGHT             N9010A          MY51440197            Dec.10, 2017         Dec. 10, 2018
                          Analyzer
                                                                                       1316.3003K07
                           Receiver                   R&S               ESR7                                Dec. 10, 2017         Dec. 10, 2018
                                                                                        -101181-K3
                       USB Wideband
                                                  KEYSIGHT            U2021XA          MY55430035           Dec. 10, 2017         Dec. 10, 2018
                       Power Sensor
                       USB Wideband
                                                  KEYSIGHT            U2021XA          MY55430023           Dec. 10, 2017         Dec. 10, 2018
                       Power Sensor
                      EXG-B RF Analog
                                                  KEYSIGHT             N5171B          MY53051777           Dec. 10, 2017         Dec. 10, 2018
                      Signal Generator
                      MXG X-Series RF
                        Vector Signal             KEYSIGHT             N5182B          MY51350267           Dec. 14, 2017         Dec. 14, 2018
                         Generator
                         DC Source                 KIKUSUI            PWR400L            LK003024           Sep. 14, 2017         Sep. 13, 2018
                      Temp & Humidity                                GL(U)04KA(
                                                     Espec                             16921H201P3          Sep. 14, 2017         Sep. 13, 2018
                          chamber                                        W)
                      Temp & Humidity                                                  58566133290
                                                    Votisch            VT4002                                Jun. 20, 2017         Jun. 20, 2018
                          chamber                                                          020


                                                   Conducted Emission Test Equipment List
                                                                                Serial                        Cal. date            Cal. Due date
          Used           Equipment               Manufacturer  Model No.
                                                                               Number                       (mm dd, yyyy)         (mm dd, yyyy)
                                                                            1316.3003K07
                           Receiver                 R&S          ESR7                                       Dec. 10, 2017         Dec. 10, 2018
                                                                             -101181-K3
                         Pulse Limiter              R&S        ESH3-Z2      0357.8810.54                    Dec. 10, 2017         Dec. 10, 2018
                             LISN                      R&S             ESH2-Z5          860014/024          Dec. 10, 2017         Dec. 10, 2018
                             LISN                ETS-Lindgren          3816/2SH          00201088           Dec. 10, 2017         Dec. 10, 2018
                        Test Software                 Audix                e3                        Software Version: 9.160323


Shenzhen UnionTrust Quality and Technology Co., Ltd.
Address: 16/F, Block A, Building 6, Baoneng Science and Technology Park, Qingxiang Road No.1, Longhua New District, Shenzhen, China
Tel: +86-755-28230888                  Fax: +86-755-28230886                  E-mail: info@uttlab.com               Http://www.uttlab.com


                                                              Page 10 of 102                          Report No.: 180320001RFC-4

4. TEST CONFIGURATION
   4.1 ENVIRONMENTAL CONDITIONS FOR TESTING
      4.1.1       Normal or Extreme Test Conditions
              Test Environment                                               Selected Values During Tests
                                                                                       Ambient
                Test Condition
                                                  Temperature (°C)                     Voltage            Relative Humidity (%)
                      TN/VN                            +15 to +35                          120V~60Hz                           20 to 75
                      TL/VL                               -10                                 102                              20 to 75
                      TH/VL                               +45                                 102                              20 to 75
                      TL/VH                                -10                                138                              20 to 75
                      TH/VH                                +45                                138                              20 to 75
         Remark:
         1) The EUT just work in such extreme temperature of -10 °C to +45 °C and the extreme voltage of 102 V to
            138 V, so here the EUT is tested in the temperature of -10 °C to +45 °C and the voltage of 102 V to 138
            V.
         2) VN: Normal Voltage; TN: Normal Temperature;
            TL: Low Extreme Test Temperature; TH: High Extreme Test Temperature;
            VL: Low Extreme Test Voltage; VH: High Extreme Test Voltage.


      4.2 TEST CHANNELS
                                                                                                 Test RF Channel Lists
                    Mode                      Tx/Rx Frequency
                                                                                Lowest(L)             Middle(M)        Highest(H)
                                                                               Channel 36               Channel 44               Channel 48
                                          5150 MHz to 5250 MHz
                                                                               5180 MHz                 5220 MHz                 5240 MHz
                                                                               Channel 52               Channel 60               Channel 64
              IEEE 802.11a                5250 MHz to 5350 MHz
                                                                               5260 MHz                 5300 MHz                 5320 MHz
           IEEE 802.11n-HT20
          IEEE 802.11ac-VHT20                                                 Channel 100              Channel 116              Channel 140
                                          5470 MHz to 5725 MHz
                                                                               5500 MHz                 5580 MHz                 5700 MHz
                                                                              Channel 149              Channel 157              Channel 165
                                          5725 MHz to 5850 MHz
                                                                               5745 MHz                 5785 MHz                 5825 MHz
                                                                              Channel 38                    --                  Channel 46
                                          5150 MHz to 5250 MHz
                                                                               5190 MHz                     --                   5230 MHz
                                                                              Channel 54                    --                  Channel 62
                                          5250 MHz to 5350 MHz
           IEEE 802.11n-HT40                                                   5270 MHz                     --                   5310 MHz
          IEEE 802.11ac-VHT40                                                 Channel 102              Channel 110              Channel 134
                                          5470 MHz to 5725 MHz
                                                                               5510 MHz                 5550 MHz                 5670 MHz
                                                                              Channel 151                   --                  Channel 159
                                          5725 MHz to 5850 MHz
                                                                               5755 MHz                     --                   5795 MHz
                                                                                   --                   Channel 42                   --
                                          5150 MHz to 5250 MHz
                                                                                   --                   5210 MHz                     --
                                                                                   --                   Channel 58                   --
                                          5250 MHz to 5350 MHz
                                                                                   --                   5290 MHz                     --
          IEEE 802.11ac-VHT80
                                                                              Channel 106                   --                  Channel 122
                                          5470 MHz to 5725 MHz
                                                                               5530 MHz                     --                   5610 MHz
                                                                                      --               Channel 155                     --
                                          5725 MHz to 5850 MHz
                                                                                      --                5775 MHz                       --




Shenzhen UnionTrust Quality and Technology Co., Ltd.
Address: 16/F, Block A, Building 6, Baoneng Science and Technology Park, Qingxiang Road No.1, Longhua New District, Shenzhen, China
Tel: +86-755-28230888                  Fax: +86-755-28230886                  E-mail: info@uttlab.com               Http://www.uttlab.com


                                                              Page 11 of 102                          Report No.: 180320001RFC-4

      4.3 EUT TEST STATUS
                   Mode                 Tx/Rx Function                                        Description
                                          1Tx/1Rx or            1.    Keep the EUT in transmitting mode with all kind of modulation
           IEEE 802.11a/n/ac
                                           2Tx/2Rx                    and all kind of data rate.

                                                                                      Power Setting
                     Mode
                                                                                      Channel 1 -13
         IEEE 802.11a                                                          Test used power level: ”50”
         IEEE 802.11n-HT20                                                     Test used power level: ”40”
         IEEE 802.11n-HT40                                                     Test used power level: ”40”
         IEEE 802.11ac-VHT20                                                   Test used power level: ”40”
         IEEE 802.11ac-VHT40                                                   Test used power level: ”40”
         IEEE 802.11ac-VHT80                                                   Test used power level: ”40”

                                                                     Test Software
         Test software name: cmd.exe;


      4.4 PRE-SCAN
       Pre-Scan has been conducted to determine the worst-case mode from all possible combinations between
       available modulations and data rates. Following rate(s) was (were) selected for the final test as listed below.
                                    Mode                                                           Worst-case data rates
                                 IEEE 802.11a                                                             6 Mbps
                              IEEE 802.11n-HT20                                                           MCS0
                              IEEE 802.11n-HT40                                                           MCS0
                             IEEE 802.11ac-VHT80                                                          MCS0


      4.5 TEST SETUP
      4.5.1       For Radiated Emissions test setup
                                                               Figure 1. Below 30MHz




Shenzhen UnionTrust Quality and Technology Co., Ltd.
Address: 16/F, Block A, Building 6, Baoneng Science and Technology Park, Qingxiang Road No.1, Longhua New District, Shenzhen, China
Tel: +86-755-28230888                  Fax: +86-755-28230886                  E-mail: info@uttlab.com               Http://www.uttlab.com


                                                              Page 12 of 102                          Report No.: 180320001RFC-4

                                                              Figure 2. 30MHz to 1GHz




                                                                Figure 3. Above 1GHz




Shenzhen UnionTrust Quality and Technology Co., Ltd.
Address: 16/F, Block A, Building 6, Baoneng Science and Technology Park, Qingxiang Road No.1, Longhua New District, Shenzhen, China
Tel: +86-755-28230888                  Fax: +86-755-28230886                  E-mail: info@uttlab.com               Http://www.uttlab.com


                                                              Page 13 of 102                          Report No.: 180320001RFC-4

      4.5.2       For Conducted Emissions test setup




      4.5.3       For Conducted RF test setup




                                                                 Normal Environment




Shenzhen UnionTrust Quality and Technology Co., Ltd.
Address: 16/F, Block A, Building 6, Baoneng Science and Technology Park, Qingxiang Road No.1, Longhua New District, Shenzhen, China
Tel: +86-755-28230888                  Fax: +86-755-28230886                  E-mail: info@uttlab.com               Http://www.uttlab.com


                                                              Page 14 of 102                          Report No.: 180320001RFC-4




                                                                 Extreme Environment


      4.6 SYSTEM TEST CONFIGURATION
       For emissions testing, the equipment under test (EUT) setup to transmit continuously to simplify the
       measurement methodology. Care was taken to ensure proper power supply voltages during testing. During
       testing, radiated emission were performed with the EUT set to transmit at the channel with highest output power
       as worst-case scenario. It was powered by a 120~60Hz. Only the worst case data were recorded in this test
       report.

       The signal is maximized through rotation and placement in the three orthogonal axes. The antenna height and
       polarization are varied during the search for maximum signal level. The antenna height is varied from 1 to 4
       meters. Radiated emissions are taken at three meters unless the signal level is too low for measurement at that
       distance. If necessary, a pre-amplifier is used and/or the test is conducted at a closer distance. Therefore, all
       final radiated testing was performed with the EUT in (see table below) orientation.

                                                                                                                         Worst-case axis
                  Frequency                              Mode                          Antenna Port
                                                                                                                          positioning
                 Above 1GHz                               1TX                              Chain 0                           Y axis

       All readings are extrapolated back to the equivalent three meter reading using inverse scaling with distance.
       Analyzer resolution is 100 kHz or greater for frequencies below 1000 MHz. The resolution is 1 MHz or greater
       for frequencies above 1000 MHz. The spurious emissions more than 20 dB below the permissible value are not
       reported.

       Radiated emission measurement were performed from the lowest radio frequency signal generated in the
       device which is greater than 9 kHz to the tenth harmonic of the highest fundamental frequency or to 40 GHz,
       whichever is lower.




Shenzhen UnionTrust Quality and Technology Co., Ltd.
Address: 16/F, Block A, Building 6, Baoneng Science and Technology Park, Qingxiang Road No.1, Longhua New District, Shenzhen, China
Tel: +86-755-28230888                  Fax: +86-755-28230886                  E-mail: info@uttlab.com               Http://www.uttlab.com


                                                              Page 15 of 102                          Report No.: 180320001RFC-4

      4.7 DUTY CYCLE
                                       Data                                    Duty                               1/ T
                                             On Time            Period                   Duty Cycle Duty Cycle             Average
                   Mode                rates                                  Cycle                             Minimum
                                              (msec)            (msec)                       (%)    Factor (dB)           Factor (dB)
                                      (Mbps)                                 (linear)                           VBW (kHz)
              IEEE 802.11a              6          1.396         1.413         0.99          98.80           0.00          0.01             -0.11
           IEEE 802.11n-HT20           MCS0        1.309         1.325         0.99          98.79           0.00          0.01             -0.11
           IEEE 802.11n-HT40           MCS0        0.649         0.666         0.97          97.45           0.11          1.54             -0.22
         IEEE 802.11ac-VHT80           MCS0        0.066         0.082         0.80          80.49           0.94          15.15            -1.89

         Remark:
         1) Duty cycle= On Time/ Period;
         2) Duty Cycle factor = 10 * log(1/ Duty cycle);
         3) Average factor = 20 log10 Duty Cycle.

         The test plot as follows
                                                                     IEEE 802.11a




Shenzhen UnionTrust Quality and Technology Co., Ltd.
Address: 16/F, Block A, Building 6, Baoneng Science and Technology Park, Qingxiang Road No.1, Longhua New District, Shenzhen, China
Tel: +86-755-28230888                  Fax: +86-755-28230886                  E-mail: info@uttlab.com               Http://www.uttlab.com


                                                              Page 16 of 102                          Report No.: 180320001RFC-4


                                                                  IEEE 802.11n-HT20




                                                                  IEEE 802.11n-HT40




Shenzhen UnionTrust Quality and Technology Co., Ltd.
Address: 16/F, Block A, Building 6, Baoneng Science and Technology Park, Qingxiang Road No.1, Longhua New District, Shenzhen, China
Tel: +86-755-28230888                  Fax: +86-755-28230886                  E-mail: info@uttlab.com               Http://www.uttlab.com


                                                              Page 17 of 102                          Report No.: 180320001RFC-4


                                                                IEEE 802.11ac-VHT80




Shenzhen UnionTrust Quality and Technology Co., Ltd.
Address: 16/F, Block A, Building 6, Baoneng Science and Technology Park, Qingxiang Road No.1, Longhua New District, Shenzhen, China
Tel: +86-755-28230888                  Fax: +86-755-28230886                  E-mail: info@uttlab.com               Http://www.uttlab.com


                                                              Page 18 of 102                          Report No.: 180320001RFC-4

5. RADIO TECHNICAL REQUIREMENTS SPECIFICATION
   5.1 REFERENCE DOCUMENTS FOR TESTING
          No.                      Identity                                             Document Title
                                                                Frequency allocations and radio treaty matters; general rules and
            1      FCC 47 CFR Part 2
                                                                regulations
            2      FCC 47 CFR Part 15                           Radio Frequency Devices
                                                                American National Standard for Testing Unlicesed Wireless
            3      ANSI C63.10-2013
                                                                Devices
                   KDB 789033 D02 General U-NII
                                                                Guidelines for compliance testing of unlicensed national
            4      Test Procedures New Rules
                                                                information infrastructure (U-NII) device part 15 subpart E
                   v02r01
                   KDB 905462 D06 802.11
            5                                                   Operation in U-NII bands -802.11 channel PLAN(§15.407)
                   Channel Plans New Rules v02
                                                                Compliance measurement procedures for Unlicensed –National
                   KDB 905462 D02 UNII DFS
                                                                Information Infrastructure devices operates in the frequency bands
            6      Compliance Procedures New
                                                                5250 MHz to 5350 MHz and 5470 MHz to 5725 MHz bands
                   Rules v02
                                                                incorporating dynamic frequency selection
                   KDB 905462 D03 Client Without
            7                                                   U-NII client devices without radar detection capability
                   DFS New Rules v01r02


      5.2 ANTENNA REQUIREMENT
                                                               Standard Requirement
         15.203 requirement:
         An intentional radiator shall be designed to ensure that no antenna other than that furnished by the
         responsible party shall be used with the device. The use of a permanently attached antenna or of an antenna
         that uses a unique coupling to the intentional radiator, the manufacturer may design the unit so that a broken
         antenna can be replaced by the user, but the use of a standard antenna jack or electrical connector is
         prohibited.
         15.407(a)(1) (2) requirement:
         The conducted output power limit specified in paragraph (a) of this section is based on the use of antennas
         with directional gains that do not exceed 6 dBi. Except as shown in paragraph (a) of this section, if
         transmitting antennas of directional gain greater than 6 dBi are used, the conducted output power and the
         peak power spectral density shall be reduced by the by the amount in dB that the directional gain of the
         antenna exceeds 6 dBi.
         EUT Antenna:
         Both antenna in the interior of the equipment and no consideration of replacement. The transmit signals are
         correlated with each other and the antenna gain of both chains is completely consistent, the best case
         directional gain of the antenna is 1.9 dBi.




Shenzhen UnionTrust Quality and Technology Co., Ltd.
Address: 16/F, Block A, Building 6, Baoneng Science and Technology Park, Qingxiang Road No.1, Longhua New District, Shenzhen, China
Tel: +86-755-28230888                  Fax: +86-755-28230886                  E-mail: info@uttlab.com               Http://www.uttlab.com


                                                              Page 19 of 102                          Report No.: 180320001RFC-4

      5.3 26 DB BANDWIDTH
         Test Requirement:            FCC 47 CFR Part 15 Subpart E Section 15.407 (a) (2)(5)
         Test Method:                 KDB 789033 D02 v02r01 Section C.1
         Limit:                       None; for reporting purposes only.
         Test Procedure:
         The output from the transmitter was connected to an attenuator and then to the input of the RF Spectrum
         analyzer.

         Spectrum analyzer according to the following Settings:
         a) Set RBW = approximately 1 % of the emission bandwidth.
         b) Set the VBW > RBW.
         c) Detector = Peak.
         d) Trace mode = max hold.
         e) Measure the maximum width of the emission that is 26 dB down from the peak of the emission. Compare
         this with the RBW setting of the analyzer. Readjust RBW and repeat measurement as needed until the
         RBW/EBW ratio is approximately 1 %.

         Note: The cable loss and attenuator loss were offset into measure device as an amplitude offset.
         Test Setup:           Refer to section 4.5.3 for details.
         Instruments Used: Refer to section 3 for details
         Test Mode:            Transmitter mode
         Test Results:         Pass
         Test Data:

                    Mode                             Channel                   26 dB Bandwidth (MHz)                99% Bandwidth (MHz)
                                                    36 (5180)                              24.98                              17.051
                                                    44 (5220)                              27.26                              16.943
                                                    48 (5240)                              30.16                              17.053
                                                    52 (5260)                              29.41                              17.083
               IEEE 802.11a                         60 (5300)                              29.09                              17.346
                                                    64 (5320)                              30.88                              17.091
                                                   100 (5500)                              23.51                              16.781
                                                   116 (5580)                              23.59                              16.884
                                                   140 (5700)                              21.63                              16.741
                                                   36 (5180)                               24.15                              17.870
                                                   44 (5220)                               29.07                              17.940
                                                   48 (5240)                               26.54                              18.059
                                                   52 (5260)                               30.70                              18.169
           IEEE 802.11n-HT20                       60 (5300)                               30.48                              18.135
                                                   64 (5320)                               29.53                              18.157
                                                   100 (5500)                              23.41                              17.815
                                                   116 (5580)                              21.20                              17.845
                                                   140 (5700)                              22.33                              17.863
                                                    38 (5190)                              43.70                              36.459
                                                    46 (5230)                              49.57                              36.186
                                                    54 (5270)                              53.15                              36.329
           IEEE 802.11n-HT40                        62 (5310)                              53.26                              36.190
                                                   102 (5510)                              44.39                              36.175
                                                   110 (5550)                              40.49                              36.186
                                                   134 (5670)                              43.05                              36.269

Shenzhen UnionTrust Quality and Technology Co., Ltd.
Address: 16/F, Block A, Building 6, Baoneng Science and Technology Park, Qingxiang Road No.1, Longhua New District, Shenzhen, China
Tel: +86-755-28230888                  Fax: +86-755-28230886                  E-mail: info@uttlab.com               Http://www.uttlab.com


                                                              Page 20 of 102                          Report No.: 180320001RFC-4

                                                    42 (5230)                              81.25                               75.711
                                                    58 (5290)                              97.06                              75.943
          IEEE 802.11ac-VHT80
                                                   106 (5530)                              81.11                              75.622
                                                   122 (5610)                              81.23                              75.684

       The test plot as follows:
                                                                      IEEE 802.11a
                                   Channel 36                                                             Channel 44




                                   Channel 48                                                             Channel 52




                                   Channel 60                                                             Channel 64




Shenzhen UnionTrust Quality and Technology Co., Ltd.
Address: 16/F, Block A, Building 6, Baoneng Science and Technology Park, Qingxiang Road No.1, Longhua New District, Shenzhen, China
Tel: +86-755-28230888                  Fax: +86-755-28230886                  E-mail: info@uttlab.com               Http://www.uttlab.com


                                                              Page 21 of 102                          Report No.: 180320001RFC-4

                                   Channel 100                                                           Channel 116




                                   Channel 140




                                                                  IEEE 802.11n-HT20
                                   Channel 36                                                             Channel 44




Shenzhen UnionTrust Quality and Technology Co., Ltd.
Address: 16/F, Block A, Building 6, Baoneng Science and Technology Park, Qingxiang Road No.1, Longhua New District, Shenzhen, China
Tel: +86-755-28230888                  Fax: +86-755-28230886                  E-mail: info@uttlab.com               Http://www.uttlab.com


                                                              Page 22 of 102                          Report No.: 180320001RFC-4

                                   Channel 48                                                             Channel 52




                                   Channel 60                                                             Channel 64




                                   Channel 100                                                           Channel 116




Shenzhen UnionTrust Quality and Technology Co., Ltd.
Address: 16/F, Block A, Building 6, Baoneng Science and Technology Park, Qingxiang Road No.1, Longhua New District, Shenzhen, China
Tel: +86-755-28230888                  Fax: +86-755-28230886                  E-mail: info@uttlab.com               Http://www.uttlab.com


                                                              Page 23 of 102                          Report No.: 180320001RFC-4

                                   Channel 140




                                                                  IEEE 802.11n-HT40
                                   Channel 38                                                             Channel 46




                                   Channel 54                                                             Channel 62




Shenzhen UnionTrust Quality and Technology Co., Ltd.
Address: 16/F, Block A, Building 6, Baoneng Science and Technology Park, Qingxiang Road No.1, Longhua New District, Shenzhen, China
Tel: +86-755-28230888                  Fax: +86-755-28230886                  E-mail: info@uttlab.com               Http://www.uttlab.com


                                                              Page 24 of 102                          Report No.: 180320001RFC-4

                                   Channel 102                                                           Channel 110




                                   Channel 134




Shenzhen UnionTrust Quality and Technology Co., Ltd.
Address: 16/F, Block A, Building 6, Baoneng Science and Technology Park, Qingxiang Road No.1, Longhua New District, Shenzhen, China
Tel: +86-755-28230888                  Fax: +86-755-28230886                  E-mail: info@uttlab.com               Http://www.uttlab.com


                                                              Page 25 of 102                          Report No.: 180320001RFC-4


                                                                IEEE 802.11ac-VHT80
                                   Channel 42                                                             Channel 58




                                   Channel 106                                                           Channel 122




Shenzhen UnionTrust Quality and Technology Co., Ltd.
Address: 16/F, Block A, Building 6, Baoneng Science and Technology Park, Qingxiang Road No.1, Longhua New District, Shenzhen, China
Tel: +86-755-28230888                  Fax: +86-755-28230886                  E-mail: info@uttlab.com               Http://www.uttlab.com


                                                              Page 26 of 102                          Report No.: 180320001RFC-4

      5.4 6 DB BANDWIDTH
         Test Requirement:            FCC 47 CFR Part 15 Subpart C Section 15.407 (e)
         Test Method:                 KDB 789033 D02 v02r01Section C.2
         Limit:                       Within the 5.725-5.85 GHz band, the minimum 6 dB bandwidth of U-NII devices shall
                                      be at least 500 kHz.
         Test Procedure:
         The output from the transmitter was connected to an attenuator and then to the input of the RF Spectrum
         Analyzer.

         Spectrum analyzer according to the following Settings:
         a) Set RBW = 100 kHz.
         b) Set the video bandwidth (VBW) ≥ 3 * RBW.
         c) Detector = Peak.
         d) Trace mode = max hold.
         e) Sweep = auto couple.
         f) Allow the trace to stabilize.
         g) Measure the maximum width of the emission that is constrained by the frequencies associated with the two
         outermost amplitude points (upper and lower frequencies) that are attenuated by 6 dB relative to the maximum
         level measured in the fundamental emission.

         Note: The cable loss and attenuator loss were offset into measure device as an amplitude offset.
         Test Setup:           Refer to section 4.5.3 for details.
         Instruments Used: Refer to section 3 for details
         Test Mode:            Transmitter mode
         Test Results:         Pass
         Test Data:

                                            Channel/               6 dB                  99%                   6 dB
                    Mode                   Frequency            Bandwidth             Bandwidth             Bandwidth              Pass / Fail
                                             (MHz)                (MHz)                 (MHz)                 Limit
                                           149 (5745)             16.28                 16.526              > 500 kHz                  Pass
               IEEE 802.11a                157 (5785)             15.97                 16.519              > 500 kHz                  Pass
                                           165 (5825)             16.30                 16.612              > 500 kHz                  Pass
                                           149 (5745)             17.29                 17.703              > 500 kHz                  Pass
           IEEE 802.11n-HT20               157 (5785)             16.08                 17.707              > 500 kHz                  Pass
                                           165 (5825)             17.63                 17.762              > 500 kHz                  Pass
                                           151 (5755)               35.30                36.172              > 500 kHz                 Pass
           IEEE 802.11n-HT40
                                           159 (5795)               35.79                36.231              > 500 kHz                 Pass
          IEEE 802.11ac-VHT80              155 (5775)               75.57                75.519              > 500 kHz                 Pass




Shenzhen UnionTrust Quality and Technology Co., Ltd.
Address: 16/F, Block A, Building 6, Baoneng Science and Technology Park, Qingxiang Road No.1, Longhua New District, Shenzhen, China
Tel: +86-755-28230888                  Fax: +86-755-28230886                  E-mail: info@uttlab.com               Http://www.uttlab.com


                                                              Page 27 of 102                          Report No.: 180320001RFC-4

       The test plot as follows:
                             IEEE 802.11a                                                            IEEE 802.11n-HT20
                                                                      Channel 149




                                                                      Channel 157




                                                                      Channel 165




Shenzhen UnionTrust Quality and Technology Co., Ltd.
Address: 16/F, Block A, Building 6, Baoneng Science and Technology Park, Qingxiang Road No.1, Longhua New District, Shenzhen, China
Tel: +86-755-28230888                  Fax: +86-755-28230886                  E-mail: info@uttlab.com               Http://www.uttlab.com


                                                              Page 28 of 102                          Report No.: 180320001RFC-4

                                                                  IEEE 802.11n-HT40
                                   Channel 151                                                           Channel 159




                             IEEE 802.11ac-VHT80
                                 Channel 155




Shenzhen UnionTrust Quality and Technology Co., Ltd.
Address: 16/F, Block A, Building 6, Baoneng Science and Technology Park, Qingxiang Road No.1, Longhua New District, Shenzhen, China
Tel: +86-755-28230888                  Fax: +86-755-28230886                  E-mail: info@uttlab.com               Http://www.uttlab.com


                                                              Page 29 of 102                          Report No.: 180320001RFC-4

      5.5 MAXIMUM CONDUCTED OUTPUT POWER
         Test Requirement: FCC 47 CFR Part 15 Subpart E Section 15.407 (a)(1)(2)(3)
         Test Method:           KDB 789033 D02 v02r01 Section E.3.a(Method PM)
         Limits:
         1. For the band 5.15-5.25 GHz.
             (i) For an outdoor access point operating in the band 5.15-5.25 GHz, the maximum conducted output
             power over the frequency band of operation shall not exceed 1 W provided the maximum antenna gain
             does not exceed 6 dBi. In addition, the maximum power spectral density shall not exceed 17 dBm in any
             1 megahertz band. If transmitting antennas of directional gain greater than 6 dBi are used, both the
             maximum conducted output power and the maximum power spectral density shall be reduced by the
             amount in dB that the directional gain of the antenna exceeds 6 dBi. The maximum e.i.r.p. at any
             elevation angle above 30 degrees as measured from the horizon must not exceed 125 mW (21 dBm).

               (ii) For an indoor access point operating in the band 5.15-5.25 GHz, the maximum conducted output
               power over the frequency band of operation shall not exceed 1 W provided the maximum antenna gain
               does not exceed 6 dBi. In addition, the maximum power spectral density shall not exceed 17 dBm in any
               1 megahertz band. If transmitting antennas of directional gain greater than 6 dBi are used, both the
               maximum conducted output power and the maximum power spectral density shall be reduced by the
               amount in dB that the directional gain of the antenna exceeds 6 dBi.

               (iii) For fixed point-to-point access points operating in the band 5.15-5.25 GHz, the maximum conducted
               output power over the frequency band of operation shall not exceed 1 W. In addition, the maximum
               power spectral density shall not exceed 17 dBm in any 1 megahertz band. Fixed point-to-point U-NII
               devices may employ antennas with directional gain up to 23 dBi without any corresponding reduction in
               the maximum conducted output power or maximum power spectral density. For fixed point-to-point
               transmitters that employ a directional antenna gain greater than 23 dBi, a 1 dB reduction in maximum
               conducted output power and maximum power spectral density is required for each 1 dB of antenna gain
               in excess of 23 dBi. Fixed, point-to-point operations exclude the use of point-to-multipoint systems,
               omnidirectional applications, and multiple collocated transmitters transmitting the same information. The
               operator of the U-NII device, or if the equipment is professionally installed, the installer, is responsible for
               ensuring that systems employing high gain directional antennas are used exclusively for fixed, point-to-
               point operations.

               (iv) For client devices in the 5.15-5.25 GHz band, the maximum conducted output power over the
               frequency band of operation shall not exceed 250 mW provided the maximum antenna gain does not
               exceed 6 dBi. In addition, the maximum power spectral density shall not exceed 11 dBm in any 1
               megahertz band. If transmitting antennas of directional gain greater than 6 dBi are used, both the
               maximum conducted output power and the maximum power spectral density shall be reduced by the
               amount in dB that the directional gain of the antenna exceeds 6 dBi.

         2.    For the 5.25-5.35 GHz and 5.47-5.725 GHz bands, the maximum conducted output power over the
               frequency bands of operation shall not exceed the lesser of 250 mW or 11 dBm + 10 log B, where B is
               the 26 dB emission bandwidth in megahertz. In addition, the maximum power spectral density shall not
               exceed 11 dBm in any 1 megahertz band. If transmitting antennas of directional gain greater than 6 dBi
               are used, both the maximum conducted output power and the maximum power spectral density shall be
               reduced by the amount in dB that the directional gain of the antenna exceeds 6 dBi.

         3.  For the band 5.725-5.85 GHz, the maximum conducted output power over the frequency band of
             operation shall not exceed 1 W. In addition, the maximum power spectral density shall not exceed 30
             dBm in any 500-kHz band. If transmitting antennas of directional gain greater than 6 dBi are used, both
             the maximum conducted output power and the maximum power spectral density shall be reduced by the
             amount in dB that the directional gain of the antenna exceeds 6 dBi. However, fixed point-to-point U-NII
             devices operating in this band may employ transmitting antennas with directional gain greater than 6 dBi
             without any corresponding reduction in transmitter conducted power. Fixed, point-to-point operations
             exclude the use of point-to-multipoint systems, omnidirectional applications, and multiple collocated
             transmitters transmitting the same information. The operator of the U-NII device, or if the equipment is
             professionally installed, the installer, is responsible for ensuring that systems employing high gain
             directional antennas are used exclusively for fixed, point-to-point operations.
         Test Procedure:

Shenzhen UnionTrust Quality and Technology Co., Ltd.
Address: 16/F, Block A, Building 6, Baoneng Science and Technology Park, Qingxiang Road No.1, Longhua New District, Shenzhen, China
Tel: +86-755-28230888                  Fax: +86-755-28230886                  E-mail: info@uttlab.com               Http://www.uttlab.com


                                                              Page 30 of 102                          Report No.: 180320001RFC-4

         1.    Connected the EUT’s antenna port to measure device by 10dB attenuator.
         2.    Method PM is used to perform output power measurement, trigger and gating function of wide band power
               meter is enabled to measure max output power of Tx on burst.

         Note: The cable loss and attenuator loss were offset into measure device as an amplitude offset.
         Test Setup:           Refer to section 4.5.3 for details.
         Instruments Used: Refer to section 3 for details
         Test Mode:            Transmitter mode
         Test Results:         Pass
         Test Data:

       Antenna gain and the maximum output power limit.

                     Frequency Band                               Antenna Gain (dBi))                         Peak Power Limits (dBm)

                          U-NII-1                                            1.9                                           24.00
                          U-NII-2A                                           1.9                                           24.00
                          U-NII-2C                                           1.9                                           24.00
                          U-NII-3                                            1.9                                           30.00


       For U-NII-1 Band:
                                           Channel/               Maximum conducted output
                                                                                                                     Limit
                  Mode                    Frequency                       power (dBm)                                               Pass / Fail
                                                                                                                    (dBm)
                                            (MHz)                 Meas Power      Corr’d Power
                                           36 (5180)                12.62            12.62                            24                Pass
              IEEE 802.11a                 44 (5220)                12.41            12.41                            24                Pass
                                           48 (5240)                12.64            12.64                            24                Pass
                                           36 (5180)                 11.68            11.68                           24                Pass
         IEEE 802.11n-HT20                 44 (5220)                 11.65            11.65                           24                Pass
                                           48 (5240)                11.75             11.75                           24                Pass
                                           38 (5190)                 7.87             7.98                            24                Pass
         IEEE 802.11n-HT40
                                           46 (5230)                   7.68                    7.79                   24                Pass
           IEEE 802.11ac-
                                42 (5210)           7.44                                       8.38                   24                Pass
               VHT80
         Remark:
         1. Corr’d Power = Meas Power + Duty Cycle Factor




Shenzhen UnionTrust Quality and Technology Co., Ltd.
Address: 16/F, Block A, Building 6, Baoneng Science and Technology Park, Qingxiang Road No.1, Longhua New District, Shenzhen, China
Tel: +86-755-28230888                  Fax: +86-755-28230886                  E-mail: info@uttlab.com               Http://www.uttlab.com



Document Created: 2019-07-08 00:28:36
Document Modified: 2019-07-08 00:28:36

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC