RF Test Report

FCC ID: 2AIHFZYO5

Test Report

Download: PDF
FCCID_3086226

         ORLAB}                                                                                      REPORT No. : SZ16050138E02
          M



                               FCC TEST REPORT


             APPLICANT                                 Guilin Zhishen Information Technology Co., Ltd.

             PRODUCT NAME                              Digital Camera Stabilizer

             MODEL NAME                                Smooth II

             TRADE NAME                                N/A

              BRAND NAME                               AJ
              FCC ID                                   2AIHFZYO5

             STANDARD(S)                               47 CFR Part 15 Subpart B

             TEST DATE                                 2016—06—28 to 2016—07—18

              ISSUE DATE                               2016—07—20




             SHENZHEN MORLAB (GO                                                              SFECHNOLOGY Co., Ltd.


NOTE: This document is issued by MORLAB, the test report shall not be reproduced except in full without prior written permission of the
company. The test results apply only to the particular sample(s) tested and to the specific tests carried out which is available on request for
validation and information confirmed at our website.


                                          FL1—3, Building A, FeiYang Science Park, No.8 LongChang Road,         Tel: 86—755—36698555   Fax: 86—755—36698525
MORLAB GROUP                              Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http:/www.morlab.cn    E—mail: service@mortab.cn


                                                                                                       REPORT No.:SZ16050138E02



                                                               DIRECTORY

 1. TECHNICAL INFORMATION ·········································································································· 5


 1.1. APPLICANT INFORMATION ··············································································································· 5
 1.2. EQUIPMENT UNDER TEST (EUT) DESCRIPTION················································································ 5


 2. TEST RESULTS ······························································································································ 6


 2.1. APPLIED REFERENCE DOCUMENTS ································································································· 6


 3. TEST CONDITIONS SETTING ······································································································· 7


 3.1. TEST MODE ···································································································································· 7
 3.2. TEST SETUP AND EQUIPMENTS LIST ······························································································· 8
 3.2.1. CONDUCTED EMISSION ··························································································································8
 3.2.2. RADIATED EMISSION ·······························································································································9


 4. 47 CFR PART 15B REQUIREMENTS ·························································································· 11


 4.1. CONDUCTED EMISSION ················································································································· 11
 4.1.1. REQUIREMENT ····································································································································· 11
 4.1.2. TEST DESCRIPTION ····························································································································· 11
 4.1.3. TEST RESULT ······································································································································· 11
 4.2. RADIATED EMISSION ····················································································································· 14
 4.2.1. REQUIREMENT ····································································································································· 14
 4.2.2. TEST DESCRIPTION ····························································································································· 14
 4.2.3. FREQUENCY RANGE OF MEASUREMENT ····························································································· 15
 4.2.4. TEST RESULT ······································································································································· 15


 ANNEX A TEST UNCERTAINTY ······································································································ 18


 ANNEX B TESTING LABORATORY INFORMATION ····································································· 19


 1.       IDENTIFICATION OF THE RESPONSIBLE TESTING LABORATORY ······················································ 19
 2.       IDENTIFICATION OF THE RESPONSIBLE TESTING LOCATION ··························································· 19




MORLAB GROUP
                                            FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,         Tel: 86-755-36698555   Fax: 86-755-36698525
                                            Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                                 Page 2 0f 19


                                                                                                     REPORT No.:SZ16050138E02


 3.         ACCREDITATION CERTIFICATE ······································································································· 19
 4.         TEST ENVIRONMENT CONDITIONS ································································································· 19




                                                               Change History
  Issue                Date                                                        Reason for change
      1.0          2016-07-20                                                            First edition




MORLAB GROUP
                                          FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,         Tel: 86-755-36698555   Fax: 86-755-36698525
                                          Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                               Page 3 0f 19


  ORLAB:                                                                              REPORT No. : SZ16050138E02
   «w
                              Test Report Declaration

   Applicant                        Guilin Zhishen Information Technology Co., Ltd.

   Applicant Address                6F, Bldg 13, Creative Industrial Park, Guimo Road

    Manufacturer                    Guilin Zhishen Information Technology Co., Ltd.

    Manufacturer Address            6F, Bldg 13, Creative Industrial Park, Guimo Road

    Product Name                    Digital Camera Stabilizer

    Model Name                      Smooth II

    Brand Name                       E

    HW Version                      V1.0

    SW Version                      V1.0

    Test Standards                  47 CFR Part 15 Subpart B

    Test Result                      PASS




               Tested by             ;            Pe'\?f SL :71)/}
                                                 Peng Shiqing(Test Engineer)


               Reviewed by           _:               Xiro X[QAg
                                                     Xiao Xiong (-EIMC Manager)


               Approved by            _:           ZEM Dya
                                                    ZeanDexin (Chief Engineer )




                           FL1—3, Building A, FeiYang Science Park, No.8 LongChang Road,         Tel: 86—755—36698555    Fax: 86—755—36698525
MORLAB GROUP               Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Fittp://www.morlab.cn   E—mail: service@morlab.cn

                                                                                                                                 Page 4 Of 19


                                                                                        REPORT No.:SZ16050138E02



 1. Technical Information
 Note: Provided by applicant


 1.1. Applicant Information
  Company:         Guilin Zhishen Information Technology Co., Ltd.
  Address:         6F, Bldg 13, Creative Industrial Park, Guimo Road


 1.2. Equipment under Test (EUT) Description
                 EUT Type: Digital Camera Stabilizer
                 Serial No: (N/A, marked #1 by test site)
        Hardware Version: V1.0
         Software Version: V1.0
            Rated Voltage: 3.7V
           Rated Current: 400mA


          Power Supply : Battery
                              Brand Name:


                              Model No.:                      18650 锂电池
                              Serial No.:                     (N/A ,marked #1 by test site)
                              Capacity:                       2000mAh
                              Rated Voltage:                  3.7V
                              Charge Limit:                   4.20V±0.05 V

 NOTE:

  1.   The EUT supports ISM 2.4GHz Bluetooth band. It is equipped with a Micro-B USB port which

       can be connected to the ancillary.

  2.   For a more detailed description, please refer to specification or user’s manual supplied by the

       applicant and/or manufacturer.




MORLAB GROUP
                             FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,         Tel: 86-755-36698555   Fax: 86-755-36698525
                             Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                  Page 5 0f 19


                                                                                        REPORT No.:SZ16050138E02



 2. Test Results
 2.1. Applied Reference Documents
 The objective of the report is to perform testing according to 47 CFR Part 15 Subpart B:

         No.    Identity                                           Document Title
         1      47 CFR Part 15(July 12, 2016 Radio Frequency Devices
                Edition)

 Test detailed items/section required by FCC rules and results are as below:

         No.   Section     Description                             Test Date                                        Result
         1     15.107      Conducted Emission                      2016.07.14                                       PASS
         2     15.109      Radiated Emission                       2016.07.14                                       PASS

 NOTE: The tests were performed according to the method of measurements prescribed in ANSI
 C63.4-2014.




MORLAB GROUP
                             FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,         Tel: 86-755-36698555   Fax: 86-755-36698525
                             Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                  Page 6 0f 19


                                                                                     REPORT No.:SZ16050138E02



 3.     Test Conditions Setting
 3.1. Test Mode

 1       The first test mode
         The EUT configuration of the emission tests is EUT + Battery + PC.
         During the measurement, the EUT was connected with a PC through the Micro-B USB
         port, the EUT was kept upgrading software and charging by the PC.
 2       The second test mode
         The EUT configuration of the emission tests is USB Line + Battery + Charger + PC.
         During the measurement, battery was put into charger which was connected with a PC
         through the USB Line, the battery was kept charging by the PC.
 Note: All test modes were performed, only the worse mode(The first test mode) was record in
 the report.




MORLAB GROUP
                          FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,         Tel: 86-755-36698555   Fax: 86-755-36698525
                          Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                               Page 7 0f 19


                                                                                       REPORT No.:SZ16050138E02



 3.2. Test Setup and Equipments List

 3.2.1. Conducted Emission

 A. Test Setup:




 The EUT is placed on a 0.8m high insulating table, which stands on the grounded conducting floor,
 and keeps 0.4m away from the grounded conducting wall. The EUT is connected to the power
 mains through a LISN which provides 50Ω/50µH of coupling impedance for the measuring
 instrument. A Pulse Limiter is used to protect the measuring instrument. The factors of the whole
 test system are calibrated to correct the reading.
 The power strip or extension cord has been investigated to make sure that the LISN integrity in
 maintained with respect to the impedance characteristics as prescribed in ANSI C63.4-2014       at
 Clause 4.3.

 B. Equipments List:

  Description       Manufacturer              Model                      Serial No.                 Cal. Date              Due. Date
    Receiver            Narda             PMM 9010                     595WX11007                  2016.01.13             2017.01.12
    Receiver            Narda             PMM 9060                     001WX11001                  2015.11.26              2016.11.25
      LISN          Schwarzbeck           NSLK 8127                         812744                 2016.01.13             2017.01.12
  Pulse Limiter                               VTSD
                    Schwarzbeck                                               9391                 2016.01.13             2017.01.12
     (20dB)                                  9561-D
       PC               Apple                 A1370               C02FQ2PYDDQW                           N/A                     N/A




MORLAB GROUP
                            FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,         Tel: 86-755-36698555   Fax: 86-755-36698525
                            Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                 Page 8 0f 19


                                                                                     REPORT No.:SZ16050138E02



 3.2.2. Radiated Emission

 A. Test Setup:
    1.   For radiated emissions from 30MHz to1GHz




    2.   For radiated emissions above 1GHz




MORLAB GROUP
                          FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,         Tel: 86-755-36698555   Fax: 86-755-36698525
                          Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                               Page 9 0f 19


                                                                                          REPORT No.:SZ16050138E02


 The test is performed in a 3m Semi-Anechoic Chamber; the antenna factor, cable loss and so on of
 the site (factors) is calculated to correct the reading. The EUT is placed on a 0.8m high insulating
 Turn Table, and keeps 3m away from the Test Antenna, which is mounted on a variable-height
 antenna master tower.

 For the test Antenna:

 In the frequency range above 30MHz, Bi-Log Test Antenna (30MHz to 1GHz) and Horn Test
 Antenna (above 1GHz) are used. Test Antenna is 3m away from the EUT. Test Antenna height is
 varied from 1m to 4m above the ground to determine the maximum value of the field strength. The
 emission levels at both horizontal and vertical polarizations should be tested.

 B. Equipments List:

 Description       Manufacturer                  Model                       Serial No.                 Cal. Date              Due. Date
   MXE EMI
                         Agilent               N9038A                      MY54130016                  2016.01.13             2017.01.12
   Receiver
Semi-Anechoic
                     Albatross               9m*6m*6m                             (n.a.)               2016.01.13             2017.01.12
  Chamber
 Test Antenna -
                   Schwarzbeck              VULB 9163                         9163-274                 2016.01.13             2017.01.12
     Bi-Log
 Test Antenna -
                   Schwarzbeck             BBHA 9120D                        9120D-963                 2016.01.13             2017.01.12
      Horn
      PC                 Apple                   A1370                C02FQ2PYDDQW                           N/A                     N/A




MORLAB GROUP
                               FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,         Tel: 86-755-36698555   Fax: 86-755-36698525
                               Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                   Page 10 0f 19


                                                                                         REPORT No.:SZ16050138E02




 4.       47 CFR Part 15B Requirements
 4.1. Conducted Emission

 4.1.1. Requirement

 According to FCC section 15.107, the radio frequency voltage that is conducted back onto the AC
 power line on any frequency within the band 150kHz to 30MHz shall not exceed the limits in the
 following table, as measured using a 50µH/50Ω line impedance stabilization network (LISN).

    Frequency range                                              Conducted Limit (dBµV)
         (MHz)                                Quasi-peak                                                  Average
        0.15 - 0.50                               66 to 56                                                 56 to 46
          0.50 - 5                                    56                                                        46
           5 - 30                                     60                                                        50
 NOTE:
 a) The limit subjects to the Class B digital device.
 b) The lower limit shall apply at the band edges.
 c) The limit decreases linearly with the logarithm of the frequency in the range 0.15 - 0.50MHz.


 4.1.2. Test Description

 See section 3.2.1 of this report.


 4.1.3. Test Result

 The maximum conducted interference is searched using Peak (PK), Quasi-peak (QP) and
 Average (AV) detectors; the emission levels more than the AV and QP limits, and that have narrow
 margins from the AV and QP limits will be re-measured with AV and QP detectors. Tests for both L
 phase and N phase lines of the power mains connected to the EUT are performed. All test modes
 are considered, refer to recorded points and plots below.




MORLAB GROUP
                              FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,         Tel: 86-755-36698555   Fax: 86-755-36698525
                              Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                  Page 11 0f 19


                                                                                       REPORT No.:SZ16050138E02




                                                (Plot A: L Phase)



          Fre.    Emission Level (dBµV)                         Limit (dBµV)
   No.                                                                                            Power-line               Verdict
         (MHz)    Quai-peak          Average           Quai-peak              Average
   1      0.15      59.38              38.32               66.00                56.00                                      PASS
   2     0.435      32.87              11.34               57.86                47.86                                      PASS
   3     0.505      31.54              22.62               56.00                46.00                                      PASS
                                                                                                   Neutral
   4      0.59      41.58              30.34               56.00                46.00                                      PASS
   5     16.155     27.62              23.82               60.00                50.00                                      PASS
   6     16.68      27.61              24.00               60.00                50.00                                      PASS




MORLAB GROUP
                            FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,           Tel: 86-755-36698555    Fax: 86-755-36698525
                            Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China     Http://www.morlab.cn    E-mail: service@morlab.cn

                                                                                                                                   Page 12 0f 19


                                                                                        REPORT No.:SZ16050138E02




                                                (Plot B: N Phase)



           Fre.    Emission Level (dBµV)                         Limit (dBµV)
    No.                                                                                            Power-line               Verdict
          (MHz)    Quai-peak          Average           Quai-peak              Average
     1     0.15      55.23              32.03               66.00                56.00                                      PASS
     2    0.515      30.40              23.81               56.00                46.00                                      PASS
     3    0.595      41.02              28.79               56.00                46.00                                      PASS
                                                                                                    Neutral
     4     1.23      33.15              26.31               56.00                46.00                                      PASS
     5     1.72      32.44              25.11               56.00                46.00                                      PASS
     6    16.685     28.82              22.65               60.00                50.00                                      PASS

 Result: Pass




MORLAB GROUP
                             FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,           Tel: 86-755-36698555    Fax: 86-755-36698525
                             Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China     Http://www.morlab.cn    E-mail: service@morlab.cn

                                                                                                                                    Page 13 0f 19


                                                                                         REPORT No.:SZ16050138E02



 4.2. Radiated Emission


 4.2.1. Requirement

 According to FCC section 15.109 (a), the field strength of radiated emissions from unintentional
 radiators at a distance of 3 meters shall not exceed the following values:

              Frequency          Field Strength Limitation at 3m Measurement Dist
             range (MHz)                    (µV/m)                                            (dBµV/m)
              30.0 - 88.0                      100                                            20log 100
             88.0 - 216.0                      150                                            20log 150
             216.0 - 960.0                     200                                            20log 200
             Above 960.0                       500                                            20log 500

 As shown in FCC section 15.35 (b), for frequencies above 1000MHz, the field strength limits are
 based on average detector. When average radiated emission measurements are specified in this
 part, including emission measurements below 1000MHz, there also is a limit on the radio
 frequency emissions, as measured using instrumentation with a peak detector function,
 corresponding to 20dB above the maximum permitted average limit for the frequency being
 investigated unless a different peak emission limit is otherwise specified in the rules.

 Note:

 1)   The tighter limit shall apply at the boundary between two frequency range.
 2)   Limitation expressed in dBµV/m is calculated by 20log Emission Level (µV/m).
 3)   If measurement is made at 3m distance, then F.S Limitation at 3m distance is adjusted by
      using the formula of Ld1 = Ld2 * (d2/d1)2.
      Example:
      F.S Limit at 30m distance is 30µV/m, then F.S Limitation at 3m distance is adjusted as
      Ld1 = L1 = 30µV/m * (10)2 = 100 * 30µV/m


 4.2.2. Test Description

 See section 3.2.2 of this report.




MORLAB GROUP
                              FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,         Tel: 86-755-36698555   Fax: 86-755-36698525
                              Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                  Page 14 0f 19


                                                                                        REPORT No.:SZ16050138E02



 4.2.3. Frequency range of measurement

 According to 15.33(b) (1), the frequency range of radiated measurement for the EUT is listed in the
 following table:




 4.2.4. Test Result

 The maximum radiated emission is searched using PK, QP and AV detectors; the emission levels
 more than the limits, and that have narrow margins from the limits will be re-measured with AV and
 QP detectors. Both the vertical and the horizontal polarizations of the Test Antenna are considered
 to perform the tests. All test modes are considered, refer to recorded points and plots below.

 The amplitude of spurious emissions which are attenuated more than 20 dB below the permissible
 value need not be reported.

 Note: All radiated emission tests were performed in X, Y, Z axis direction, and only the worst axis
 test condition was recorded in this test report.

 A. Upgrading Software Test Mode:




MORLAB GROUP
                             FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,         Tel: 86-755-36698555   Fax: 86-755-36698525
                             Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                 Page 15 0f 19


                                                                                       REPORT No.:SZ16050138E02




                     (Plot A: 30MHz – 6GHz, Test Antenna Vertical)


  No.     Fre.       Pk            QP                AV           Limit-PK          Limit-QP      Limit-AV          ANT            Verdict
          MHz      dBµV/m      dBµV/m            dBµV/m           dBµV/m             dBµV/m        dBµV/m
  1      44.568     N.A.         26.09             N.A.              N.A.              40.00          N.A.               V         PASS
  2      65.207     N.A.         31.68             N.A.              N.A.              40.00          N.A.               V         PASS
  3     157.472     N.A.         39.60             N.A.              N.A.              43.50          N.A.               V         PASS
  4     400.275     N.A.         28.58             N.A.              N.A.              46.00          N.A.               V         PASS
  5     1361.104   40.00          N.A.            35.99             74.00               N.A.         54.00               V         PASS
  6     2324.690   42.88          N.A.            36.12             74.00               N.A.         54.00               V         PASS




MORLAB GROUP
                            FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,         Tel: 86-755-36698555       Fax: 86-755-36698525
                            Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn       E-mail: service@morlab.cn

                                                                                                                                    Page 16 0f 19


                                                                                        REPORT No.:SZ16050138E02




                     (Plot B: 30MHz – 6GHz, Test Antenna Horizontal)


   No.     Fre.       Pk            QP                AV           Limit-PK          Limit-QP      Limit-AV          ANT            Verdict
           MHz      dBµV/m      dBµV/m            dBµV/m           dBµV/m            dBµV/m        dBµV/m
   1      65.207     N.A.         23.79              N.A.             N.A.             40.00          N.A.                H         PASS
   2     118.623     N.A.         29.58              N.A.             N.A.             43.50          N.A.                H         PASS
   3     155.044     N.A.         38.96              N.A.             N.A.             43.50          N.A.                H         PASS
   4     243.667     N.A.         41.82              N.A.             N.A.             46.00          N.A.                H         PASS
   5     1344.458   40.16          N.A.             33.12            74.00              N.A.         54.00                H         PASS
   6     2689.616   43.79          N.A.             35.48            74.00              N.A.         54.00                H         PASS

 Result: Pass




MORLAB GROUP
                             FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,         Tel: 86-755-36698555       Fax: 86-755-36698525
                             Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn       E-mail: service@morlab.cn

                                                                                                                                     Page 17 0f 19


                                                                                      REPORT No.:SZ16050138E02



 Annex A         Test Uncertainty
 The uncertainty is calculated using the methods suggested in the "Guide to the Expression of
 Uncertainty in Measurement" (GUM) published by ISO.
 Uncertainty of Conducted Emission:            ±1.8dB
 Uncertainty of Radiated Emission:             ±3.1dB




MORLAB GROUP
                           FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,         Tel: 86-755-36698555   Fax: 86-755-36698525
                           Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                               Page 18 0f 19


                                                                                       REPORT No.:SZ16050138E02



 Annex B          Testing Laboratory Information

 1. Identification of the Responsible Testing Laboratory
  Company Name:                             Shenzhen Morlab Communications Technology Co., Ltd.
  Department:                               Morlab Laboratory
  Address:                                  FL.3, Building A, FeiYang Science Park, No.8 LongChang
                                            Road, Block 67, BaoAn District, ShenZhen, GuangDong
                                            Province, P. R. China
  Responsible Test Lab Manager:             Mr. Su Feng
  Telephone:                                +86 755 36698555
  Facsimile:                                +86 755 36698525


 2. Identification of the Responsible Testing Location

  Name:                                     Shenzhen Morlab Communications Technology Co., Ltd.
                                            Morlab Laboratory
  Address:                                  FL.3, Building A, FeiYang Science Park, No.8 LongChang
                                            Road, Block 67, BaoAn District, ShenZhen, GuangDong
                                            Province, P. R. China


 3. Accreditation Certificate
  Accredited Testing Laboratory:            The FCC registration number is 695796.
                                            (Shenzhen Morlab Communications Technology Co., Ltd.)


 4. Test Environment Conditions
 During the measurement, the environmental conditions were within the listed ranges:

  Temperature (°C):                         15 - 35
  Relative Humidity (%):                    30 - 60
  Atmospheric Pressure (kPa):               86 - 106



                                     ***** END OF REPORT *****




MORLAB GROUP
                            FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,         Tel: 86-755-36698555   Fax: 86-755-36698525
                            Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                Page 19 0f 19



Document Created: 2019-10-31 19:28:41
Document Modified: 2019-10-31 19:28:41