RF Exposure

FCC ID: 2AI88-BTPBT2017

RF Exposure Info

Download: PDF
FCCID_3817130

RF Exposure Compliance Requirement
The product belongs to standalone portable device base the FCC rule part 2.1093. The transmission
frequencies of the device are between 100 MHz and 6 GHz. The worst case test separation distance is
5mm.
The Max Conducted Output Power and SAR Test Exclusion Threshold (mW) are listed below:


 Transmit frequency       Max Conducted           Max Conducted          SAR Test Exclusion
        (GHz)           Output Power (dBm)      Output Power (mW)          Threshold (mW)
        2.402                    1                     1.259                     9.68
        2.441                    3                     1.995                     9.62
        2.480                    4                     2.512                     9.52


      Frequency                                                         Tune up max power
                          Nominal Power           Tolerance(dB)
        (MHz)                                                                 (dBm)
        2.402                  0dBm                     +/- 1                     1
        2.441                  2dBm                     +/- 1                     3
        2.480                  3dBm                     +/- 1                     4


The SAR Test Exclusion Threshold for 100 MHz to 6 GHz is calculated from:
1)   The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances
≤ 50 mm are determined by:
[(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)] ·
[√f(GHz)] ≤ 3.0 for 1-g SAR     and ≤ 7.5 for 10-g extremity SAR,      where
      f(GHz) is the RF channel transmit frequency in GHz
      Power and distance are rounded to the nearest mW and mm before calculation
     The result is rounded to one decimal place for comparison
The test exclusions are applicable only when the minimum test separation distance is ≤ 50 mm and for
transmission frequencies between 100 MHz and 6 GHz.        When the minimum test separation distance is <
5 mm, a distance of 5 mm is applied to determine SAR test exclusion.


According to SAR Exclusion Threshold in KDB 447498 (D01) General RF Exposure
Guidance v06, the SAR report is not required.



Document Created: 2018-04-11 16:41:19
Document Modified: 2018-04-11 16:41:19

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC