RF Exposure

FCC ID: 2AI88-1126882

RF Exposure Info

Download: PDF
FCCID_3486487

RF Exposure Compliance Requirement
The product belongs to standalone portable device base the FCC rule part 2.1093. The transmission
frequencies of the device are between 100 MHz and 6 GHz. The worst case test separation distance is
5mm.
The Max Conducted Output Power and SAR Test Exclusion Threshold (mW) are listed below:


 Transmit frequency       Max Conducted           Max Conducted          SAR Test Exclusion
        (GHz)           Output Power (dBm)      Output Power (mW)          Threshold (mW)
        2.402                    2                     1.585                    9.68
        2.441                    2                     1.585                    9.62
        2.480                    2                     1.585                    9.52


     Frequency                                                          Tune up max power
                         Nominal Power            Tolerance(dB)
       (MHz)                                                                  (dBm)
        2.402                  1dBm                     +/- 1                     2
        2.441                  1dBm                     +/- 1                     2
        2.480                  1dBm                     +/- 1                     2


The SAR Test Exclusion Threshold for 100 MHz to 6 GHz is calculated from:
1) The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances
≤ 50 mm are determined by:
[(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)] ·
[√f(GHz)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR,          where
     f(GHz) is the RF channel transmit frequency in GHz
     Power and distance are rounded to the nearest mW and mm before calculation
    The result is rounded to one decimal place for comparison
The test exclusions are applicable only when the minimum test separation distance is ≤ 50 mm and for
transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation distance is <
5 mm, a distance of 5 mm is applied to determine SAR test exclusion.


According to SAR Exclusion Threshold in KDB 447498 (D01) General RF Exposure
Guidance v06, the SAR report is not required.