RF Exposure

FCC ID: 2AI7B-W5

RF Exposure Info

Download: PDF
FCCID_4457810

OttLite Technologies, Inc.
TEST REPORT
SCOPE OF WORK
SAR Assessment– W5

REPORT NUMBER
190829003SZN-002

ISSUE DATE           [REVISED DATE]
16 September 2019    [--------------------]

PAGES
4


DOCUMENT CONTROL NUMBER
RF Exposure
© 2017 INTERTEK


                                                                                101, 201, Building B, No. 308 Wuhe Avenue, Zhangkengjing
                                                                                Community, GuanHu Subdistrict, LongHua District, ShenZhen.
                                                                                Tel: (86 755) 8601 6288
                                                                                Fax: (86 755) 8601 6751
                                                                                www.intertek.com
TEST REPORT                                                                                 Intertek No.: 190829003SZN-002


                                                          Test Report

Applicant                                    :           OttLite Technologies, Inc.
                                                         220 West 7th Avenue STE 100
                                                         Tampa, FL 33602 United States

Sample Description
Product                                      :           LED table lamp
Model No.                                    :           W5

Brand Name                                   :
Electrical Rating                            :           Input: DC 12V, 3A from adapter
                                                         Output: DC5V, 1A or DC9V, 1.1A by Wireless Charging
                                                         Output: DC5V, 2.1A by USB

Date Received                                :           29 August 2019
Date Test Conducted                          :           29 August 2019 to 12 September 2019

Test Requested                               :           Test for compliance with CFR 47 part 1
Test Method                                  :           Environmental evaluation and exposure limit according
                                                         to FCC CFR 47 part 1, 1.1307(c) and (d), 1.1310

Test Result                                  :           Pass
Conclusion                                   :           When determining of test conclusion, measurement
                                                         uncertainty of tests have been considered.

  ******************************** End of Page ********************************




Prepared and Checked By:                                                Approved By:




Jeff Liang                                                              Kidd Yang
Engineer                                                                Technical Supervisor
                                                                        Date: 16 September 2019
This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's
responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to
the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is
authorized to permit copying or distribution of this report and then only in its entirety. Any use of the Intertek name or one of its marks for
the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test
results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or
has ever been under an Intertek certification program.
                                   Intertek Testing Services Shenzhen Ltd. Longhua Branch
               101, 201, Building B, No. 308 Wuhe Avenue, Zhangkengjing Community, GuanHu Subdistrict, LongHua District, ShenZhen.
                                             Tel: (86 755) 8601 6288         Fax: (86 755) 8601 6751
Version: 01-November-2017                                       Page 1 of 4                                                          RF Exposure


TEST REPORT                                               Intertek No.: 190829003SZN-002


                                     Test Report
Test Setup Configuration




Note
- The RF exposure test is performed in the shield room.
- The test distance is between the edge of the charger and the geometric centre of probe.

Test Equipment List
    Name of instrument         Model      Manufacturer       Cal. Date        Due Date
   Exposure Level Tester      EHP-50F        Narda          01-Apr-2019      01-Apr-2020




Version: 01-November-2017                Page 2 of 4                              RF Exposure


TEST REPORT                                                          Intertek No.: 190829003SZN-002

Reference Limit:
Environmental evaluation and exposure limit according to FCC CFR 47 part 1, 1.1307(c)
and (d), 1.1310

According to FCC 1.1310: The criteria listed in the following table shall be used to evaluate
the environment impact of human exposure to radio frequency (RF) radiation.

LIMITS FOR MAXIMUM PERMISSIBLE EXPOSURE (MPE)
Frequency Range Electric Field           Magnetic Field     Power Density              Average Time
     (MHz)         strength (V/m)        Strength (A/m)       (mW/cm2)                   (minutes)
                       (A) Limits for Occupational/Controlled Exposure
    0.3 – 3.0            614                  1.63              (100) *                         6
                  (B) Limits for General Population/Uncontrolled Exposure
   0.3 – 1.34            614                  1.63              (100) *                         30
Note: * = Plane wave equivalent power density

Test Result:
H-Field Strength at 15 cm surrounding the EUT and 20cm above the top surface of the EUT
 Frequency       EUT           Probe        Probe        Probe           Probe        Probe
                                                                                                     Limits
   Range       Operation      Position     Position     Position        Position     Position
                                                                                                     (A/m)
   (MHz)        mode        Front (A/m)   Rear (A/m)   Left (A/m)     Right (A/m)   Top (A/m)
   0.110-      1% Battery
                              0.0233       0.0928           0.0344      0.0594       0.0234          1.63
   0.205         Level
                  50%
   0.110-
                Battery       0.0231       0.0925           0.0342      0.0593       0.0231          1.63
   0.205
                 Level
                  99%
   0.110-
                Battery       0.0233       0.0927           0.0344      0.0591       0.0233          1.63
   0.205
                 Level
   0.110-
                Stand-by      0.0023       0.0024           0.0231      0.0242       0.0241          1.63
   0.205

E-Field Strength at 15 cm surrounding the EUT and 20cm above the top surface of the EUT
 Frequency       EUT           Probe        Probe        Probe           Probe        Probe
                                                                                                     Limits
   Range       Operation      Position     Position     Position        Position     Position
                                                                                                     (V/m)
   (MHz)        mode        Front (V/m)   Rear (V/m)   Left (V/m)     Right (V/m)   Top (V/m)
   0.110-      1% Battery
                              0.6726       0.7984           0.8536      0.7775       1.0372           614
   0.205         Level
                  50%
   0.110-
                Battery       0.6724       0.7982           0.8536      0.7774       1.0371           614
   0.205
                 Level
                  99%
   0.110-
                Battery       0.6724       0.7983           0.8535      0.7774       1.0370           614
   0.205
                 Level
   0.110-
                Stand-by      0.6725       0.0372           0.0328      0.0592       0.0343           614
   0.205




Version: 01-November-2017                     Page 3 of 4                                       RF Exposure


TEST REPORT                                                Intertek No.: 190829003SZN-002

Configuration photo of the test:

For electronic filing, H-Field & E-Field Strength configuration photographs are saved with
filename: H-Field & E-Field Strength test setup photos.pdf.


  ****************************** End of Report******************************




Version: 01-November-2017                 Page 4 of 4                               RF Exposure



Document Created: 2019-09-22 16:17:01
Document Modified: 2019-09-22 16:17:01

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC