RF Exposure

FCC ID: 2AI7B-MA70M

RF Exposure Info

Download: PDF
FCCID_4171557

OttLite Technologies, Inc.

TEST REPORT
SCOPE OF WORK
SAR ASSESSMENT– MA70M

REPORT NUMBER
181213013SZN-003

ISSUE DATE         [REVISED DATE]

21 January 2019    [---------------------]

PAGES
3


DOCUMENT CONTROL NUMBER
RF Exposure
© 2017 INTERTEK


                                                                               101, 201, Building B, No. 308 Wuhe Avenue, Zhangkengjing Community,
                                                                               GuanHu Subdistrict, LongHua District, ShenZhen.

                                                                               Tel: (86 755) 8601 6288
                                                                               Fax: (86 755) 8601 6751
    TEST REPORT                                                                www.intertek.com

                                                                   Test Report

Applicant:                  OttLite Technologies, Inc.                                                       Number:           181213013SZN-003

                            1715 N Westshore Blvd|Suite 950| Tampa, FL                                       Date:        21 January 2019
                            33607

Sample Description
   Product                            :         LED DESK LAMP
   Model No.                          :         MA70M

Brand Name                           :          OttLite
Electrical Rating                    :          Input: AC100-240V, 50/60Hz, 1A; Output: DC 12V, 2500mA for adapter
                                                DC5V, 1A output by wireless charger

Date Received                         :         13 December 2018

Date Test Conducted                   :         13 December 2018 to 27 December 2018

Test Requested                        :         Test for compliance with CFR 47 part 1

Test Method                              :      Environmental evaluation and exposure limit according to FCC
                                                CFR 47 part 1, 1.1307(c) and (d), 1.1310


Test Result                           :         Pass

Conclusion                            :         When determining of test conclusion, measurement uncertainty of tests have
                                                been considered.
.

**************************************************** End of Page ****************************************************

Prepared and Checked By:                                                            Approved By:




Jeff Liang                                                                          Kidd Yang
Engineer                                                                            Technical Supervisor
                                                                                    Date: 21 January 2019


This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility
and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with
the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to permit copying or distribution of this
report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service
must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does
not imply that the material, product, or service is or has ever been under an Intertek certification program.


                                             Intertek Testing Services Shenzhen Ltd. Longhua Branch
                       101, 201, Building B, No. 308 Wuhe Avenue, Zhangkengjing Community, GuanHu Subdistrict, LongHua District, ShenZhen.
                                                          Tel: (86 755) 8601 6288 Fax: (86 755) 8601 6751

Version: 01-November-2017                                                       Page 1 of 3                                                   RF Exposure


 TEST REPORT




                                         Test Report
Test Setup Configuration



                             20cm




                                              15 cm




Note

- The RF exposure test is performed in the shield room.
- The test distance is between the edge of the charger and the geometric centre of probe.



Test Equipment List
    Name of instrument             Model              Manufacturer    Cal. Date     Due Date
    Exposure Level Tester      ELT-4002304/03            Narda        21-Mar-18     21-Mar-19
         Field Probe              HI-6105                 ETS         21-Mar-18     21-Mar-19
     Laser Data Interface         HI-6113                 ETS         21-Mar-18     21-Mar-19




Version: 01-November-2017                             Page 2 of 3                           RF Exposure


 TEST REPORT



Reference Limit:
Environmental evaluation and exposure limit according to FCC CFR 47 part 1,
1.1307(c) and (d), 1.1310

According to FCC 1.1310: The criteria listed in the following table shall be used to evaluate
the environment impact of human exposure to radio frequency (RF) radiation.

LIMITS FOR MAXIMUM PERMISSIBLE EXPOSURE (MPE)
Frequency Range        Electric Field         Magnetic Field       Power Density       Average Time
     (MHz)            strength (V/m)          Strength (A/m)         (mW/cm2)            (minutes)
                            (A) Limits for Occupational/Controlled Exposure
     0.3 – 3.0               614                   1.63                (100)*                6
                       (B) Limits for General Population/Uncontrolled Exposure
    0.3 – 1.34               614                   1.63                (100)*               30
Note: * = Plane wave equivalent power density


Test Result:
H-Field Strength at 15 cm surrounding the EUT and 20cm above the top surface of the
EUT
                                  Probe
Frequency            EUT                       Probe          Probe        Probe         Probe
                                 Position                                                        Limits
  Range            Operation                  Position       Position     Position      Position
                                  Front                                                          (A/m)
  (MHz)             mode                     Rear (A/m)     Left (A/m)   Right (A/m)   Top (A/m)
                                  (A/m)
                 10% Battery
0.110-0.205                       0.041         0.037         0.042        0.039         0.035       1.63
                   Level
                 50% Battery
0.110-0.205                       0.042         0.034         0.041        0.036         0.032       1.63
                   Level
                 90% Battery
0.110-0.205                       0.040         0.036         0.038        0.038         0.034       1.63
                   Level
0.110-0.205        Stand-by       0.039         0.032         0.035        0.035         0.033       1.63


E-Field Strength at 15 cm surrounding the EUT and 20cm above the top surface of the
EUT
Frequency           EUT          Probe         Probe          Probe        Probe         Probe
                                                                                                    Limits
  Range           Operation     Position      Position       Position     Position      Position
                                                                                                    (V/m)
  (MHz)            mode        Front (V/m)   Rear (V/m)     Left (V/m)   Right (V/m)   Top (V/m)
                 10% Battery
0.110-0.205                       0.411         0.404         0.427        0.394         0.377        614
                    Level
                 50% Battery
0.110-0.205                       0.408         0.400         0.415        0.382         0.375        614
                    Level
                 90% Battery
0.110-0.205                       0.402         0.411         0.406        0.377         0.370        614
                    Level
0.110-0.205        Stand-by       0.385         0.381         0.395        0.370         0.367        614



       ************************************** End of Report**************************************



Version: 01-November-2017                            Page 3 of 3                              RF Exposure



Document Created: 2019-02-19 10:21:49
Document Modified: 2019-02-19 10:21:49

© 2024 FCC.report