RF Exposure

FCC ID: 2AI7B-A13

RF Exposure Info

Download: PDF
FCCID_4280498

OttLite Technologies, Inc.
TEST REPORT
SCOPE OF WORK
SAR Assessment– A13

REPORT NUMBER
190411011SZN-003

ISSUE DATE            [REVISED DATE]
28 April 2019         [--------------------]

PAGES
4


DOCUMENT CONTROL NUMBER
RF Exposure
© 2017 INTERTEK


                                                                                101, 201, Building B, No. 308 Wuhe Avenue, Zhangkengjing
                                                                                Community, GuanHu Subdistrict, LongHua District, ShenZhen.
                                                                                Tel: (86 755) 8601 6288
                                                                                Fax: (86 755) 8601 6751
                                                                                www.intertek.com
TEST REPORT                                                                                 Intertek No.: 190411011SZN-003


                                                          Test Report

Applicant                                    :           OttLite Technologies, Inc.
                                                         1715 N Westshore Blvd, Suite 950,
                                                         Tampa, FL 33607, USA

Sample Description
Product                                      :           Wireless Charger
Model No.                                    :           A13
Brand Name                                   :           OttLite
Electrical Rating                            :           Input: AC100-240V, 50/60Hz, 1A; Output: DC 12V, 2A for
                                                         adapter
                                                         DC5V, 1A output by wireless charger

Date Received                                :           11 April 2019
Date Test Conducted                          :           11 April 2019 to 25 April 2019

Test Requested                               :           Test for compliance with CFR 47 part 1
Test Method                                  :           Environmental evaluation and exposure limit according
                                                         to FCC CFR 47 part 1, 1.1307(c) and (d), 1.1310

Test Result                                  :           Pass
Conclusion                                   :           When determining of test conclusion, measurement
                                                         uncertainty of tests have been considered.

  ******************************** End of Page ********************************




Prepared and Checked By:                                                Approved By:




Jeff Liang                                                              Kidd Yang
Engineer                                                                Technical Supervisor
                                                                        Date: 28 April 2019

This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's
responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to
the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is
authorized to permit copying or distribution of this report and then only in its entirety. Any use of the Intertek name or one of its marks for
the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test
results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or
has ever been under an Intertek certification program.
                                   Intertek Testing Services Shenzhen Ltd. Longhua Branch
               101, 201, Building B, No. 308 Wuhe Avenue, Zhangkengjing Community, GuanHu Subdistrict, LongHua District, ShenZhen.
                                             Tel: (86 755) 8601 6288         Fax: (86 755) 8601 6751
Version: 01-November-2017                                       Page 1 of 4                                                          RF Exposure


TEST REPORT                                               Intertek No.: 190411011SZN-003


                                     Test Report
Test Setup Configuration


                                   20cm




                                             15 cm




Note
- The RF exposure test is performed in the shield room.
- The test distance is between the edge of the charger and the geometric centre of probe.

Test Equipment List
  Name of instrument             Model         Manufacturer     Cal. Date     Due Date
 Exposure Level Tester      ELT-4002304/03        Narda       14-Mar-2019    14-Mar-2020
       Field Probe              HI-6105            ETS        30-Aug-2018    30-Aug-2019
  Laser Data Interface          HI-6113            ETS        26-Jun-2018    26-Jun-2019




Version: 01-November-2017                 Page 2 of 4                             RF Exposure


TEST REPORT                                                         Intertek No.: 190411011SZN-003

Reference Limit:
Environmental evaluation and exposure limit according to FCC CFR 47 part 1, 1.1307(c)
and (d), 1.1310

According to FCC 1.1310: The criteria listed in the following table shall be used to evaluate
the environment impact of human exposure to radio frequency (RF) radiation.

LIMITS FOR MAXIMUM PERMISSIBLE EXPOSURE (MPE)
Frequency Range Electric Field           Magnetic Field     Power Density             Average Time
     (MHz)         strength (V/m)        Strength (A/m)       (mW/cm2)                  (minutes)
                       (A) Limits for Occupational/Controlled Exposure
    0.3 – 3.0            614                  1.63              (100) *                        6
                  (B) Limits for General Population/Uncontrolled Exposure
   0.3 – 1.34            614                  1.63              (100) *                        30
Note: * = Plane wave equivalent power density

Test Result:
H-Field Strength at 15 cm surrounding the EUT and 20cm above the top surface of the EUT
 Frequency       EUT           Probe        Probe        Probe          Probe        Probe
                                                                                                    Limits
   Range       Operation      Position     Position     Position       Position     Position
                                                                                                    (A/m)
   (MHz)        mode        Front (A/m)   Rear (A/m)   Left (A/m)    Right (A/m)   Top (A/m)
                 10%
   0.110-
                Battery       0.054         0.058           0.051       0.055        0.047          1.63
   0.205
                 Level
                 50%
   0.110-
                Battery       0.058         0.054           0.052       0.057        0.043          1.63
   0.205
                 Level
                 90%
   0.110-
                Battery       0.054         0.056           0.058       0.058        0.046          1.63
   0.205
                 Level
   0.110-
                Stand-by      0.049         0.044           0.045       0.045        0.044          1.63
   0.205

E-Field Strength at 15 cm surrounding the EUT and 20cm above the top surface of the EUT
 Frequency       EUT           Probe        Probe        Probe          Probe        Probe
                                                                                                    Limits
   Range       Operation      Position     Position     Position       Position     Position
                                                                                                    (V/m)
   (MHz)        mode        Front (V/m)   Rear (V/m)   Left (V/m)    Right (V/m)   Top (V/m)
                 10%
   0.110-
                Battery       0.471         0.464           0.455       0.472        0.418           614
   0.205
                 Level
                 50%
   0.110-
                Battery       0.424         0.441           0.418       0.409        0.411           614
   0.205
                 Level
                 90%
   0.110-
                Battery       0.411         0.427           0.431       0.442        0.408           614
   0.205
                 Level
   0.110-
                Stand-by      0.408         0.451           0.421       0.468        0.412           614
   0.205




Version: 01-November-2017                     Page 3 of 4                                      RF Exposure


TEST REPORT                                                 Intertek No.: 190411011SZN-003

Configuration photo of the test:

For electronic filing, H-Field Strength configuration photographs are saved with filename: H-
Field Strength test photos.pdf.

For electronic filing, E-Field Strength configuration photographs are saved with filename: E-
Field Strength test photos.pdf.



  ****************************** End of Report******************************