MPE - DXX

FCC ID: 2AI6Y-GUARDIAN

RF Exposure Info

Download: PDF
FCCID_4129307

RF Exposure Requirements:          §1.1307(b)(1) and §1.1307(b)(2): Systems operating under the provisions of
                                   this section shall be operated in a manner that ensures that the public is not
                                   exposed to radio frequency energy levels in excess of the Commission’s
                                   guidelines.

RF Radiation Exposure Limit:       §1.1310: As specified in this section, the Maximum Permissible Exposure
                                   (MPE) Limit shall be used to evaluate the environmental impact of human
                                   exposure to radiofrequency (RF) radiation as specified in Sec. 1.1307(b), except
                                   in the case of portable devices which shall be evaluated according to the
                                   provisions of Sec. 2.1093 of this chapter.

                          MPE Limit: EUT’s operating frequencies @ 905-924.8; Limit for Uncontrolled
                          exposure: f/1500 mW/cm2 = 0.617 mW/cm2Equation from page 18 of OET 65, Edition
                          97-01

                          S = PG / 4R2       or    R = √(PG / 4S)

                 where, S = Power Density (mW/cm2)
                        P = Power Input to antenna (mW)
                        G = Antenna Gain (numeric value)
                        R = Distance (cm)

Test Results:

Max Fundamental field strength: 88.08 dBuV/m @ 924.8 MHz
EIRP = P + G = E + 20Log(d) – 104.77
P = E – G + 20 Log (d) – 104.77
P = -8.15 dBm = 0.153 mW




                                                           FCC
                                                                Pwr.
Frequency Con. Pwr. Con. Pwr. Ant. Gain Ant. Gain                       Limit                     Distance
                                                              Density         2        Margin                  Result
  (MHz)    (dBm)     (mW)       (dBi)   numeric                       (mW/cm   )                    (cm)
                                                             (mW/cm2)
   924.8        -8.15      0.153          1        1.259      0.00004   0.617          0.61696         20        Pass


The safe distance where Power Density is less than the MPE Limit listed above was found to be 20 cm.



Document Created: 2018-12-06 09:36:37