RF Exposure Report

FCC ID: 2AI6DX96MINI

RF Exposure Info

Download: PDF
FCCID_3725189

RF EXPOSURE
REPORT

Report No.: 17071320-FCC-H
Supersede Report No.: N/A
Applicant          SHENZHEN AMEDIATECH TECHNOLOGY CO., LTD
Product Name       Smart TV BOX
Model No.          X96mini
Serial No.         N/A
Test Standard      FCC 2.1091:2017
Test Date          November 24, 2017 to January 11, 2018
Issue Date         January 11, 2018
Test Result            Pass      Fail
Equipment complied with the specification
Equipment did not comply with the specification




        Aaron Liang                     David Huang
       Test Engineer                    Checked By

                      This test report may be reproduced in full only
     Test result presented in this test report is applicable to the tested sample only


                                         Issued by:
                    SIEMIC (SHENZHEN-CHINA) LABORATORIES
                   Zone A, Floor 1, Building 2 Wan Ye Long Technology Park
       South Side of Zhoushi Road, Bao’ an District, Shenzhen, Guangdong China 518108
                 Phone: +86 0755 2601 4629801 Email: China@siemic.com.cn


                                          Test Report       17071320-FCC-H
                                          Page
                                          No.               2 of 9




                             Laboratories Introduction

SIEMIC, headquartered in the heart of Silicon Valley, with superior facilities in US and Asia, is one
of the leading independent testing and certification facilities providing customers with one-stop
shop services for Compliance Testing and Global Certifications.




In addition to testing and certification, SIEMIC provides initial design reviews and compliance
management throughout a project. Our extensive experience with China, Asia Pacific, North
America, European, and International compliance requirements, assures the fastest, most cost
effective way to attain regulatory compliance for the global markets.


                       Accreditations for Conformity Assessment
            Country/Region                                           Scope
                   USA                            EMC, RF/Wireless, SAR, Telecom
                 Canada                           EMC, RF/Wireless, SAR, Telecom
                  Taiwan                           EMC, RF, Telecom, SAR, Safety
               Hong Kong                                RF/Wireless, SAR, Telecom
                 Australia                         EMC, RF, Telecom, SAR, Safety
                  Korea                          EMI, EMS, RF, SAR, Telecom, Safety
                  Japan                            EMI, RF/Wireless, SAR, Telecom
                Singapore                                EMC, RF, SAR, Telecom
                  Europe                           EMC, RF, SAR, Telecom, Safety


                                      Test Report   17071320-FCC-H
                                      Page
                                      No.           3 of 9




This page has been left blank intentionally.


                                                               Test Report            17071320-FCC-H
                                                               Page
                                                               No.                    4 of 9




CONTENTS

1.    REPORT REVISION HISTORY ............................................................................................................ 5

2.    CUSTOMER INFORMATION ................................................................................................................ 5

3.    TEST SITE INFORMATION .................................................................................................................. 5

4.    EQUIPMENT UNDER TEST (EUT) INFORMATION ............................................................................. 6

5.    FCC §2.1091 - MAXIMUM PERMISSIBLE EXPOSURE (MPE) ............................................................. 7

5.1 APPLICABLE STANDARD ..................................................................................................................... 7

5.2 TEST RESULT ....................................................................................................................................... 8


                                             Test Report    17071320-FCC-H
                                             Page
                                             No.            5 of 9




1. Report Revision History

         Report No.              Report Version             Description                  Issue Date
      17071320-FCC-H                  NONE                    Original                January 11, 2018




2. Customer information


Applicant Name          SHENZHEN AMEDIATECH TECHNOLOGY CO., LTD
Applicant Add           No. 01, 2/F, A Plant, Block B, Minsheng Industrial Park, Longmei Road,Gaofeng
                        Community, Dalang Office, Longhua District, Shenzhen, China
Manufacturer            SHENZHEN AMEDIATECH TECHNOLOGY CO., LTD
Manufacturer Add        No. 01, 2/F, A Plant, Block B, Minsheng Industrial Park, Longmei Road,Gaofeng
                        Community, Dalang Office, Longhua District, Shenzhen, China



3. Test site information
 Lab performing tests       SIEMIC (Shenzhen-China) LABORATORIES
                            Zone A, Floor 1, Building 2 Wan Ye Long Technology Park
 Lab Address                South Side of Zhoushi Road, Bao’ an District, Shenzhen, Guangdong China
                            518108
 FCC Test Site No.          535293
 IC Test Site No.           4842E-1
 Test Software              Radiated Emission Program-To Shenzhen v2.0


                                          Test Report   17071320-FCC-H
                                          Page
                                          No.           6 of 9




 4. Equipment under Test (EUT) Information
Description of EUT:             Smart TV BOX



Main Model:                     X96mini


Serial Model:                   N/A


Date EUT received:              November 24, 2017


Test Date(s):                   November 24, 2017 to January 11, 2018


Antenna Gain:                   0dBi


Antenna Type:                   PCB antenna


Type of Modulation:             802.11b/g/n: DSSS, OFDM


RF Operating Frequency (ies):   WIFI: 802.11b/g/n(20M): 2412-2462 MHz


Number of Channels:             WIFI :802.11b/g/n(20M): 11CH



Port:                           Power Port, ETHERNET Port, HV Port, AV Port

Trade Name :                    N/A


FCC ID:                         2AI6DX96MINI


                                          Test Report       17071320-FCC-H
                                          Page
                                          No.               7 of 9




 5. FCC §2.1091 - Maximum Permissible exposure (MPE)



5.1 Applicable Standard

According to §1.1307(b)(1), systems operating under the provisions of this section shall be
operated in a manner that ensures that the public is not exposed to radio frequency energy level in
excess of the Commission’ s guidelines.


According to §1.1310 and §2.1091 RF exposure is calculated.


   Limits for General Population/Uncontrolled Exposure

                           Limits for General Population/Uncontrolled Exposure
 Frequency Range       Electric Field      Magnetic Field            Power Density   Averaging Time
       (MHz)           Strength (V/m)      Strength (A/m)              (mW/cm2)        (minutes)

      0.3-1.34              614                  1.63                   *(100)            30
      1.34-30              824/f                 2.19/f                *(180/f2)          30
      30-300               27.5                  0.073                    0.2             30
     300-1500                /                     /                    f/1500            30
   1500-100,000              /                     /                      1.0             30


f = frequency in MHz
* = Plane-wave equivalent power density


     )
                                             Test Report       17071320—FCC—H
     l E M l C
 S A Bureau Veritas Group Company            Page              8 of $




5.2 Test Result


                                                                                              Tune Up
                                                                                Conducted
   Type             Test mode          CH                  Freq (MHz)                          Power
                                                                            Power (dBm)
                                                                                               (dBm)
                                       Low                   2412                 7.56           74%1
                      802.11b          Mid                   2437                 7.46           74%1
                                       High                  2462                 7.08           74%1
                                       Low                   2412                 7.06           74%1
   Output
                      802.11g          Mid                   2437                 7.38           74%1
   power                                 —
                                       High                  2462                 7.77           74%1
                                       Low                   2412                 7.15           74%1
                      802.11n
                                       Mid                   2437                 7.03           74%1
                        (20M)
                                       High                  2462                 7.40           74%1



Predication of MPE limit at a given distance

                 PG
        S
               arR*

Where: S = power density (in appropriate units, e.g. mW/cm?)
       P = power input to the antenna (in appropriate units, e.g., mW).
       G = power gain of the antenna in the direction of interest relative to an isotropic radiator,
              the power gain factor, is normally numeric gain.
       R = distance to the center of radiation of the antenna (appropriate units, e.g., cm)


For the antenna manufacturer provide only used limited to ERP/EIRP or radiated spurious
emission test. The MPE evaluation as below:


                       Maximum output power at antenna input terminal: 8(dBm)
            Maximum output power at antenna input terminal: 6.310mW)
                                                      Prediction distance: >20 (cm)
                                                    Predication frequency: 2412 (MHz) Low frequency
Antenna Gain (typical):0(dBi)
Antenna Gain (typical):1.000 (numeric)
The worst case is power density at predication frequency at 20 cm: 0.00125(mW/cm?)


                                        Test Report   17071320-FCC-H
                                        Page
                                        No.           9 of 9




MPE limit for general population exposure at prediction frequency: 1.0 (mW/cm2)


0.00125(mW/cm2) < 1.0 (mW/cm2)


Result: Pass



Document Created: 2019-10-14 07:16:00
Document Modified: 2019-10-14 07:16:00

© 2024 FCC.report