Test Report

FCC ID: 2AI53-MC601V

Test Report

Download: PDF
FCCID_3102180

                                            FCC PART 15.249
                                               TEST REPORT
                                                               For

                Shenzhen Merrytek Technology Co.,LTD
                 NO.3 Building,380 Xiangshan Avenue,Luotian,Songgang Town,Bao'an
                                 District,Shenzhen,Guangdong,China


                                         FCC ID: 2AI53-MC601V



           Report Type:                                         Product Type:
           Original Report                                     Lighting Control Switch


                     Test Engineer:        Rocky Xiao


                    Report Number: RDG160616051-00


                       Report Date:         2016-08-11
                                           Jerry Zhang
                      Reviewed By:         EMC Manager

                  Test Laboratory:         Bay Area Compliance Laboratories Corp. (Dongguan)
                                           No.69 Pulongcun, Puxinhu Industrial Zone,
                                           Tangxia, Dongguan, Guangdong, China
                                           Tel: +86-769-86858888
                                           Fax: +86-769-86858891
                                           www.baclcorp.com.cn




Note: This test report is prepared for the customer shown above and for the device described herein. It may not be duplicated or
used in part without prior written consent from Bay Area Compliance Laboratories Corp. (Dongguan).


Bay Area Compliance Laboratories Corp. (Dongguan)                                                                           Report No.: RDG160616051-00



                                                       TABLE OF CONTENTS

GENERAL INFORMATION .......................................................................................................................................3
 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) .....................................................................................3
 OBJECTIVE ...................................................................................................................................................................3
 RELATED SUBMITTAL(S)/GRANT(S) .............................................................................................................................3
 TEST METHODOLOGY ..................................................................................................................................................3
 TEST FACILITY .............................................................................................................................................................3
SYSTEM TEST CONFIGURATION ..........................................................................................................................4
  JUSTIFICATION .............................................................................................................................................................4
  EUT EXERCISE SOFTWARE ..........................................................................................................................................4
  EQUIPMENT MODIFICATIONS .......................................................................................................................................4
  SUPPORT EQUIPMENT LIST AND DETAILS ....................................................................................................................4
  EXTERNAL I/O CABLE..................................................................................................................................................4
  BLOCK DIAGRAM OF TEST SETUP ................................................................................................................................4
SUMMARY OF TEST RESULTS ...............................................................................................................................5

FCC§15.203 - ANTENNA REQUIREMENT..............................................................................................................6
  APPLICABLE STANDARD ..............................................................................................................................................6
  ANTENNA CONNECTOR CONSTRUCTION ......................................................................................................................6
FCC §15.207 (A) – AC LINE CONDUCTED EMISSIONS ......................................................................................7
  APPLICABLE STANDARD ..............................................................................................................................................7
  MEASUREMENT UNCERTAINTY ....................................................................................................................................7
  EUT SETUP ..................................................................................................................................................................7
  EMI TEST RECEIVER SETUP .........................................................................................................................................8
  TEST PROCEDURE ........................................................................................................................................................8
  CORRECTED AMPLITUDE & MARGIN CALCULATION ...................................................................................................8
  TEST EQUIPMENT LIST AND DETAILS ...........................................................................................................................9
  TEST RESULTS SUMMARY ............................................................................................................................................9
  TEST DATA ..................................................................................................................................................................9
FCC§15.205, §15.209&§15.249- RADIATED EMISSIONS ....................................................................................12
  APPLICABLE STANDARD ............................................................................................................................................12
  MEASUREMENT UNCERTAINTY ..................................................................................................................................12
  EUT SETUP ................................................................................................................................................................13
  TEST EQUIPMENT SETUP ............................................................................................................................................14
  TEST PROCEDURE ......................................................................................................................................................14
  CORRECTED AMPLITUDE & MARGIN CALCULATION .................................................................................................14
  TEST EQUIPMENT LIST AND DETAILS .........................................................................................................................15
  TEST DATA ................................................................................................................................................................15
FCC §15.215(C) – 20 DB BANDWIDTH TESTING ................................................................................................19
  APPLICABLE STANDARD ............................................................................................................................................19
  TEST PROCEDURE ......................................................................................................................................................19
  TEST EQUIPMENT LIST AND DETAILS .........................................................................................................................19
  TEST DATA ................................................................................................................................................................19




FCC Part 15.249                                                                                                                                         Page 2 of 20


Bay Area Compliance Laboratories Corp. (Dongguan)                              Report No.: RDG160616051-00

GENERAL INFORMATION
Product Description for Equipment under Test (EUT)
The Shenzhen Merrytek Technology Co.,LTD’s product, model number: MC601V (FCC ID: 2AI53-
MC601V) (the "EUT") in this report was a Lighting Control Switch, which was measured approximately:8
cm (L) x 4.3 cm (W) x 1.7 cm (H), rated input voltage: AC120.0V.


 All measurement and test data in this report was gathered from production sample serial number: 160616051
 (Assigned by BACL, Dongguan). The EUT was received on 2016-06-22.


Objective
This type approval report is prepared on behalf of Shenzhen Merrytek Technology Co.,LTD. in accordance
with Part 2-Subpart J, and Part 15-Subparts A, B and C of the Federal Communication Commissions rules.

The tests were performed in order to determine compliance with FCC Part 15, Subpart C, and section
15.203, 15.205,15.207, 15.209 and 15.249 rules.


Related Submittal(s)/Grant(s)
No related submittal.


Test Methodology
All measurements contained in this report were conducted with ANSI C63.10-2013, American National
Standard of Procedures for Compliance Testing of Unlicensed Wireless Devices.

All emissions measurement was performed and Bay Area Compliance Laboratories Corp. (Dongguan).


Test Facility
The Test site used by Bay Area Compliance Laboratories Corp. (Dongguan) to collect test data is located
on the No.69 Pulongcun, Puxinhu Industrial Zone, Tangxia, Dongguan, Guangdong, China

Test site at Bay Area Compliance Laboratories Corp. (Dongguan) has been fully described in reports
submitted to the Federal Communication Commission (FCC). The details of these reports have been found
to be in compliance with the requirements of Section 2.948 of the FCC Rules on February 06, 2015.

The Federal Communications Commission has the reports on file and is listed under FCC Registration No.:
273710. The test site has been approved by the FCC for public use and is listed in the FCC Public Access
Link (PAL) database.




FCC Part 15.249                                                                                   Page 3 of 20


Bay Area Compliance Laboratories Corp. (Dongguan)                                Report No.: RDG160616051-00

SYSTEM TEST CONFIGURATION
Justification
The system was configured for testing in engineering mode with maximum power output. The device
operating at 5770MHz.


EUT Exercise Software
No software was used in testing.


Equipment Modifications
No modifications were made to the EUT.


Support Equipment List and Details

       Manufacturer                  Description                      Model                 Serial Number
        Supersun                     LED LAMP                       SPSA191227                   N/A


External I/O Cable

                             Shielding                      Length
    Cable Description                    Ferrite Core                              From                To
                               Type                          (m)
      AC Power Line             No            No              2.0                  EUT               Lamp


Block Diagram of Test Setup

                                                                                    LISN1




                                                        Led Lamp      10cm   EUT




          Non-Conductive Table 80
          cm above Ground Plane

                                         1.5 Meter




FCC Part 15.249                                                                                    Page 4 of 20


Bay Area Compliance Laboratories Corp. (Dongguan)                 Report No.: RDG160616051-00


SUMMARY OF TEST RESULTS

                  FCC Rules                 Description of Test         Result

                   §15.203                 Antenna Requirement       Compliance

                  §15.207(a)               Conduction Emissions      Compliance

          15.205, §15.209, §15.249          Radiated Emissions       Compliance

                  §15.215 (c)                20 dB Bandwidth         Compliance




FCC Part 15.249                                                                   Page 5 of 20


Bay Area Compliance Laboratories Corp. (Dongguan)                            Report No.: RDG160616051-00

FCC§15.203 - ANTENNA REQUIREMENT
Applicable Standard
For intentional device, according to §15.203, an intentional radiator shall be designed to ensure that no
antenna other than that furnished by the responsible party shall be used.


Antenna Connector Construction
The EUT has an internal antenna, the antenna gain is 0dBi, fulfill the requirement of this section. Please
refer to the EUT photos.

Result: Compliant.




FCC Part 15.249                                                                                Page 6 of 20


Bay Area Compliance Laboratories Corp. (Dongguan)                          Report No.: RDG160616051-00

FCC §15.207 (a) – AC LINE CONDUCTED EMISSIONS
Applicable Standard
FCC§15.207


Measurement Uncertainty
Compliance or non- compliance with a disturbance limit shall be determined in the following manner:

If Ulab is less than or equal to Ucispr of Table 1, then:
–compliance is deemed to occur if no measured disturbance level exceeds the disturbance limit;
–non - compliance is deemed to occur if any measured disturbance level exceeds the disturbance limit.
If Ulab is greater than Ucispr of Table 1, then:
–compliance is deemed to occur if no measured disturbance level, increased by (Ulab − Ucispr), exceeds the
disturbance limit;
–non - compliance is deemed to occur if any measured disturbance level, increased by (Ulab − Ucispr),
exceeds the disturbance limit.

Based on CISPR 16-4-2-2011, measurement uncertainty of conducted disturbance at mains port using AMN at
Bay Area Compliance Laboratories Corp. (Dongguan) is 3.12 dB (150 kHz to 30 MHz).

                                         Table 1 – Values of Ucispr

                                Measurement                                            Ucispr
Conducted disturbance at mains port using AMN (150 kHz to 30 MHz)                      3.4 dB


EUT Setup




FCC Part 15.249                                                                                 Page 7 of 20


Bay Area Compliance Laboratories Corp. (Dongguan)                            Report No.: RDG160616051-00

The setup of EUT is according with per ANSI C63.10-2013 measurement procedure. The specification
used was with the FCC Part 15.207 limits.

The spacing between the peripherals was 10 cm.

The EUT was connected to a 120 VAC/60 Hz power source.


EMI Test Receiver Setup
The EMI test receiver was set to investigate the spectrum from 150 kHz to 30 MHz.

During the conducted emission test, the EMI test receiver was set with the following configurations:

                               Frequency Range                      IF B/W
                              150 kHz – 30 MHz                       9 kHz



Test Procedure
During the conducted emission test, the adapter of laptop was connected to the first LISN.

Maximizing procedure was performed on the six (6) highest emissions of the EUT.

All data was recorded in the Quasi-peak and average detection mode.


Corrected Amplitude & Margin Calculation
The basic equation is as follows:

VC = VR + AC + VDF
Cf = AC + VDF

Herein,
VC (cord. Reading): corrected voltage amplitude
VR: reading voltage amplitude
Ac: attenuation caused by cable loss
VDF: voltage division factor of AMN
Cf: Correction Factor

The “Margin” column of the following data tables indicates the degree of compliance within the
applicable limit. For example, a margin of 7dB means the emission is 7dB below the maximum limit. The
equation for margin calculation is as follows:

        Margin = Limit – Corrected Amplitude




FCC Part 15.249                                                                              Page 8 of 20


Bay Area Compliance Laboratories Corp. (Dongguan)                                Report No.: RDG160616051-00

Test Equipment List and Details

                                                                      Serial       Calibration   Calibration
       Manufacturer              Description          Model
                                                                     Number           Date        Due Date
            R&S               EMI Test Receiver      ESCS 30       830245/006      2015-12-10    2016-12-09

            R&S                    L.I.S.N           ESH3-Z5       892107/021      2015-07-16    2016-07-15

            R&S              Two-line V-network      ENV 216      3560.6550.12     2015-11-26    2016-11-25

            R&S                 Test Software         EMC32       Version8.53.0       N/A            N/A

   * Statement of Traceability: Bay Area Compliance Laboratories Corp. (Dongguan) attests that all calibrations
    have been performed, traceable to National Primary Standards and International System of Units (SI).


Test Results Summary
According to the recorded data in following table, the EUT complied with the FCC Part 15.207, with the
worst margin reading of:

                           23.1 dB at 0.429420 MHz in the Line conducted mode


Test Data
     Environmental Conditions

              Temperature:           26.3°C
         Relative Humidity:           57 %
            ATM Pressure:           100.9 kPa

     The testing was performed by Rocky Xiao on 2016-06-24.




FCC Part 15.249                                                                                    Page 9 of 20


Bay Area Compliance Laboratories Corp. (Dongguan)                                                  Report No.: RDG160616051-00

    Test Mode: Transmitting

     AC120 V, 60 Hz, Line:


                           70

                                                                                                              Quasi-Peak Limit
                           60

                                                                                                                   Average Limit
                           50


                           40
            Level in dBμ




                           30


                           20


                           10


                            0


                           -10
                             150k         300   400 500     800 1M         2M    3M     4M 5M 6     8 10M             20M     30M
                                                                     Frequency in Hz




     Frequency                      Quasi Peak       Bandwidth                  Corr.      Margin       Limit
                                                                     Line                                                   Comment
       (MHz)                         (dBμV)            (kHz)                    (dB)        (dB)       (dBμV)
      0.151200                         39.2            9.000          L1        10.2        26.7         65.9             Compliance
      0.429420                         27.9               9.000       L1        10.2        29.4            57.3          Compliance
      0.468757                         27.3               9.000       L1        10.1        29.2            56.5          Compliance
      1.239175                         24.3               9.000       L1        10.4        31.7            56.0          Compliance
      1.279307                         22.1               9.000       L1        10.4        33.9            56.0          Compliance
      2.518372                         24.1               9.000       L1        10.4        31.9            56.0          Compliance

     Frequency                       Average         Bandwidth                  Corr.      Margin       Limit
                                                                     Line                                                   Comment
       (MHz)                         (dBμV)            (kHz)                    (dB)        (dB)       (dBμV)
      0.166371                         26.1            9.000          L1        10.1        29.0         55.1             Compliance
      0.429420                         24.2               9.000       L1        10.2        23.1            47.3          Compliance
      0.446873                         23.4               9.000       L1        10.2        23.5            46.9          Compliance
      0.930151                         17.2               9.000       L1        10.4        28.8            46.0          Compliance
      1.239175                         18.7               9.000       L1        10.4        27.3            46.0          Compliance
      1.259081                         17.1               9.000       L1        10.4        28.9            46.0          Compliance




FCC Part 15.249                                                                                                             Page 10 of 20


Bay Area Compliance Laboratories Corp. (Dongguan)                                                 Report No.: RDG160616051-00

     AC120 V, 60 Hz, Neutral:



                          70

                                                                                                            Quasi-Peak Limit
                          60

                                                                                                               Average Limit
                          50


                          40
           Level in dBμ




                          30


                          20


                          10


                           0


                          -10
                            150k       300    400 500      800 1M       2M     3M     4M 5M 6     8 10M           20M     30M
                                                                    Frequency in Hz




     Frequency                     Quasi Peak           Bandwidth              Corr.      Margin           Limit
                                                                      Line                                               Comment
       (MHz)                        (dBμV)                (kHz)                (dB)        (dB)           (dBμV)
      0.150000                        36.3                9.000        N       10.2        29.7             66.0        Compliance
      0.409372                        27.9                9.000        N        10.2       29.8            57.7         Compliance
      0.495646                        25.8                9.000        N        10.1       30.3            56.1         Compliance
      0.786832                        22.8                9.000        N        10.3       33.2            56.0         Compliance
      1.385415                        25.7                9.000        N        10.4       30.3            56.0         Compliance
     15.126541                        23.4                9.000        N        10.7       36.6            60.0         Compliance

     Frequency                      Average             Bandwidth              Corr.      Margin           Limit
                                                                      Line                                               Comment
       (MHz)                        (dBμV)                (kHz)                (dB)        (dB)           (dBμV)
      0.167702                        27.3                9.000        N       10.1        27.8             55.1        Compliance
      0.429420                        20.5                9.000        N        10.2       26.8            47.3         Compliance
      0.446873                        20.6                9.000        N        10.1       26.3            46.9         Compliance
      1.239175                        18.9                9.000        N        10.4       27.1            46.0         Compliance
      1.363512                        17.1                9.000        N        10.4       28.9            46.0         Compliance
     15.126541                        22.8                9.000        N        10.7       27.2            50.0         Compliance




FCC Part 15.249                                                                                                           Page 11 of 20


Bay Area Compliance Laboratories Corp. (Dongguan)                           Report No.: RDG160616051-00

FCC§15.205, §15.209&§15.249- RADIATED EMISSIONS
Applicable Standard

As per FCC§15.249 (a), except as provided in paragraph (b) of this section, the field strength of
emissions from intentional radiators operated within these frequency bands shall comply with the
following:


            Fundamental         Field strength of fundamental       Field strength of harmonics
             frequency                 (millivolts/meter)                (microvolts/meter)

            902–928 MHz                      50                                 500

          2400–2483.5 MHz                    50                                 500

           5725–5875 MHz                     50                                 500

           24.0–24.25 GHz                    250                                2500


  As per FCC§15.249 (c), Field strength limits are specified at a distance of 3 meters.

 (d) Emissions radiated outside of the specified frequency bands, except for harmonics, shall be attenuated
  by at least 50 dB below the level of the fundamental or to the general radiated emission limits in §15.209,
  whichever is the lesser attenuation.


Measurement Uncertainty
Compliance or non- compliance with a disturbance limit shall be determined in the following manner:

If Ulab is less than or equal to Ucispr of Table 1, then:
–compliance is deemed to occur if no measured disturbance level exceeds the disturbance limit;
–non - compliance is deemed to occur if any measured disturbance level exceeds the disturbance limit.
If Ulab is greater than Ucispr of Table 1, then:
–compliance is deemed to occur if no measured disturbance level, increased by (Ulab − Ucispr), exceeds the
disturbance limit;
–non - compliance is deemed to occur if any measured disturbance level, increased by (Ulab − Ucispr),
exceeds the disturbance limit.

Based on CISPR 16-4-2: 2011, measurement uncertainty of radiated emission at a distance of 3m at Bay
Area Compliance Laboratories Corp. (Dongguan) is: 30M~200MHz: 4.58 dB for Horizontal, 4.59 dB for
Vertical; 200M~1GHz: 4.83 dB for Horizontal, 5.85 dB for Vertical; 1G~6GHz: 4.45 dB, 6G~18GHz: 5.23
dB




FCC Part 15.249                                                                               Page 12 of 20


Bay Area Compliance Laboratories Corp. (Dongguan)                              Report No.: RDG160616051-00

                                          Table 1 – Values of Ucispr

                                        Measurement                                             Ucispr
Radiated disturbance (electric field strength at an OATS or in a SAC) (30 MHz to 1000 MHz)      6.3 dB
Radiated disturbance (electric field strength in a FAR)           (1 GHz to 6 GHz)              5.2 dB
Radiated disturbance (electric field strength in a FAR)           (6 GHz to 18 GHz)             5.5 dB


EUT Setup
Below 1 GHz:




Above 1 GHz:




The radiated emission and out of band emission tests were performed in the 3 meters chamber test site,
using the setup accordance with the ANSI C63.10-2013 The specification used was the FCC 15.209/15.205
and FCC 15.249 limits.


FCC Part 15.249                                                                                Page 13 of 20


Bay Area Compliance Laboratories Corp. (Dongguan)                            Report No.: RDG160616051-00

Test Equipment Setup
The system was investigated from 30 MHz to 40 GHz.

During the radiated emission test, the EMI test receiver & Spectrum Analyzer Setup were set with the
following configurations:

              Frequency Range            RBW         Video B/W        IF B/W          Detector
             30 MHz – 1000 MHz          120 kHz        300 kHz        120 kHz            QP
                                         1MHz           3 MHz            /               PK
                  Above 1 GHz
                                         1MHz           10 Hz            /              Ave.


Test Procedure
Maximizing procedure was performed on the highest emissions to ensure that the EUT complied with all
installation combinations.

All data was recorded in the Quasi-peak detection mode from 30 MHz to 1GHz, peak and average
detection mode above 1 GHz.


Corrected Amplitude & Margin Calculation
The Corrected Amplitude is calculated by adding the Antenna Factor and Cable Loss, and subtracting the
Amplifier Gain from the Meter Reading. The basic equation is as follows:

        Corrected Amplitude = Meter Reading + Antenna Factor + Cable Loss - Amplifier Gain

The “Margin” column of the following data tables indicates the degree of compliance with the applicable
limit. For example, a margin of 7dB means the emission is 7dB below the limit. The equation for margin
calculation is as follows:

        Margin = Limit –Corrected Amplitude




FCC Part 15.249                                                                                Page 14 of 20


Bay Area Compliance Laboratories Corp. (Dongguan)                               Report No.: RDG160616051-00

Test Equipment List and Details

                                                                     Serial       Calibration   Calibration
       Manufacturer            Description          Model
                                                                    Number           Date        Due Date
           R&S             EMI Test Receiver         ESCI           100224        2015-08-03    2016-08-02
          Sunol
                                 Antenna             JB3           A060611-3      2014-11-06     2017-11-05
         Sciences
            HP                 Amplifier            8447E         2434A02181      2015-09-01     2016-09-01
          Agilent          Spectrum Analyzer       E4440A         SG43360054      2015-11-23     2016-11-22
       ETS-Lindgren          Horn Antenna            3115          9808-5557      2015-09-06     2018-09-06
        Mini-Circuit           Amplifier         ZVA-213-S+        054201245      2016-02-19     2017-02-19
           R&S             Spectrum Analyzer       FSP 38            100478       2016-05-09     2017-05-09
        Ducommun                                                  1007726-01
                               Horn Antenna     ARH-4223-02                       2014-06-16     2017-06-15
       Technolagies                                                   1304
                                                    QLW-
          Quinstar               Amplifier                       15964001001      2015-09-06     2016-09-06
                                                 18405536-JO
           N/A                 Coaxial Cable         14m             N/A          2016-05-06     2017-05-06
           N/A                 Coaxial Cable          8m             N/A          2016-05-06     2017-05-06
        Ducommun                                                  1007726-01
                               Horn Antenna     ARH-2823-02                       2014-06-16     2017-06-15
       Technolagies                                                  1302

   * Statement of Traceability: Bay Area Compliance Laboratories Corp. (Dongguan) attests that all calibrations
    have been performed, traceable to National Primary Standards and International System of Units (SI).


Test Data
     Environmental Conditions

             Temperature:            27.1 oC
        Relative Humidity:            48 %
            ATM Pressure:           100.1 kPa

    The testing was performed by Rocky Xiao on 2016-06-27.

     Test Mode: Transmitting




FCC Part 15.249                                                                                    Page 15 of 20


Bay Area Compliance Laboratories Corp. (Dongguan)                       Report No.: RDG160616051-00

Test Mode: Transmitting

30MHz-1GHz:

     Horizontal




                    Receiver                    Correction     Cord.
    Frequency                                                               Limit        Margin
                    Reading        Detector      Factor        Amp.
      (MHz)                                                               (dBμV/m)        (dB)
                    (dBμV)                       (dB/m)      (dBμV/m)
     30.0000          24.65          QP             0.95      25.60         40.00         14.40
     103.7200         25.80          QP             -8.60     17.20         43.50         26.30
     213.3300         31.44          QP             -8.94     22.50         43.50         21.00
     336.5200         26.05          QP             -5.15     20.90         46.00         25.10
     384.0500         25.49          QP             -4.09     21.40         46.00         24.60
     451.9500         24.23          QP             -2.43     21.80         46.00         24.20




FCC Part 15.249                                                                         Page 16 of 20


Bay Area Compliance Laboratories Corp. (Dongguan)                       Report No.: RDG160616051-00

Vertical




                    Receiver                    Correction     Cord.
    Frequency                                                               Limit        Margin
                    Reading        Detector      Factor        Amp.
      (MHz)                                                               (dBμV/m)        (dB)
                    (dBμV)                       (dB/m)      (dBμV/m)
     30.0000         27.55           QP              0.95     28.50         40.00         11.50
     41.6400         42.85           QP              -7.65    35.20         40.00          4.80
     61.0400         40.29           QP             -12.89    27.40         40.00         12.60
     89.1700         35.62           QP             -12.02    23.60         43.50         19.90
     127.0000        28.00           QP              -5.60    22.40         43.50         21.10
     188.1100        35.18           QP              -8.28    26.90         43.50         16.60




FCC Part 15.249                                                                         Page 17 of 20


 Bay Area Compliance Laboratories Corp. (Dongguan)                         Report No.: RDG160616051-00


                   Receiver             Rx Antenna     Cable   Amplifier   Corrected
Frequency                                                                                Limit     Margin
            Reading                  Polar    Factor    loss    Gain       Amplitude
  (MHz)                 Detector                                                       (dBμV/m)     (dB)
            (dBμV)                   (H/V) (dB(1/m))   (dB)      (dB)      (dBμV/m)
   5770      71.08         PK          H       32.15    5.49    26.57        82.15       114.00     31.85
   5770      49.86        AV           H       32.15    5.49    26.57        60.93       94.00      33.07
   5770       87.3         PK          V       32.15    5.49    26.57        98.37       114.00     15.63
   5770      65.56        AV           V       32.15    5.49    26.57        76.63       94.00      17.37
   5725       29.4         PK          V       32.15    5.60    26.63        40.52       74.00      33.48
  11540      34.51         PK          V       37.90    8.94    26.10        55.25       74.00      18.75
  11540      22.37        AV           V       37.90    8.94    26.10        43.11       54.00      10.89
  17310      29.53         PK          V       41.36   13.25    25.63        58.51        74.00     15.49
  17310      17.18        AV           V       41.36   13.25    25.63        46.16       54.00      7.84
   6875       31.3         PK          V       33.28    6.31    26.51        44.38       74.00      29.62
   6875      18.87        AV           V       33.28    6.31    26.51        31.95       54.00      22.05
  10425      30.02         PK          V       36.99    8.29    25.66        49.64       74.00      24.36
  10425      17.58        AV           V       36.99    8.29    25.66        37.20       54.00      16.80




 FCC Part 15.249                                                                           Page 18 of 20


Bay Area Compliance Laboratories Corp. (Dongguan)                               Report No.: RDG160616051-00

FCC §15.215(c) – 20 dB BANDWIDTH TESTING
Applicable Standard
Intentional radiators operating under the alternative provisions to the general emission limits, as contained
in §§ 15.217 through 15.257 and in Subpart E of this part, must be designed to ensure that the 20 dB
bandwidth of the emission, or whatever bandwidth may otherwise be specified in the specific rule section
under which the equipment operates, is contained within the frequency band designated in the rule section
under which the equipment is operated.

Test Procedure
1. Check the calibration of the measuring instrument using either an internal calibrator or a known signal
   from an external generator.
2. Position the EUT on the test table without connection to measurement instrument. Turn on the EUT.
   Then set it to any one convenient frequency within its operating range. Set a reference level on the
   measuring instrument equal to the highest peak value.
3. Measure the frequency difference of two frequencies that were attenuated 20 dB from the reference
   level. Record the frequency difference as the emission bandwidth.
4. Repeat above procedures until all frequencies measured were complete.

Test Equipment List and Details

                                                                     Serial       Calibration Calibration
      Manufacturer            Description           Model
                                                                    Number           Date      Due Date

           R&S           Spectrum Analyzer          FSP 38           100478        2015-11-23    2016-11-22
                                                    EMDCB-
       E-Microwave          DC Blocking                           0E01201047       2016-05-06    2017-05-06
                                                     00036
            N/A             Coaxial Cable            0.1m             N/A          2016-05-06    2017-05-06

   * Statement of Traceability: Bay Area Compliance Laboratories Corp. (Dongguan) attests that all calibrations
    have been performed, traceable to National Primary Standards and International System of Units (SI).


Test Data
     Environmental Conditions

              Temperature:              28.4 °C
         Relative Humidity:              40 %
            ATM Pressure:              100.3 kPa

    * The testing was performed by Rocky Xiao on 2016-07-06.

      Test Result: Compliant.

       Please refer to following tables and plots




FCC Part 15.249                                                                                    Page 19 of 20


Bay Area Compliance Laboratories Corp. (Dongguan)                       Report No.: RDG160616051-00

    Test Mode: Transmitting

                                  Frequency           20 dB Bandwidth
                                    (MHz)                  (MHz)
                                     5770                   3.208



                                              Middle Channel




                                    ***** END OF REPORT *****