14_QUEST TestRpt JBP

FCC ID: 2AHZ5QUEST

Test Report

Download: PDF
FCCID_4181493

                                                   Page 1 of 23               Report No.: HK1812211958E




                            FCC TEST REPORT



                                            Test report
                                           On Behalf of
                          Shenzhen Huafurui Technology Co., Ltd.
                                                For
                                          Smart Phone
                                       Model No.: QUEST



                                     FCC ID: 2AHZ5QUEST

Prepared for :    Shenzhen Huafurui Technology Co., Ltd.
                  Unit 1401 &1402, 14/F, Jin qi zhi gu mansion (No. 4 building of Chong wen Garden),
                  Crossing of the Liu xian street and Tang ling road, Tao yuan street, Nan shan district,
                  Shenzhen,P.R. China


Prepared By :      Shenzhen HUAK Testing Technology Co., Ltd.
                   1F, B2 Building, Junfeng Zhongcheng Zhizao Innovation Park, Fuhai Street, Bao'an
                   District, Shenzhen City, China


Date of Test:     Dec. 28, 2018~Jan. 09, 2019
Date of Report:   Feb. 18, 2019
Report Number:    HK1812211958E


                                                                          Page 2 of 23           Report No.: HK1812211958E



                                               TEST RESULT CERTIFICATION
Applicant’s name ................. :                Shenzhen Huafurui Technology Co., Ltd.
                                                    Unit 1401 &1402, 14/F, Jin qi zhi gu mansion (No. 4 building of Chong
Address.................................. :         wen Garden), Crossing of the Liu xian street and Tang ling road, Tao
                                                    yuan street, Nan shan district, Shenzhen,P.R. China
Manufacture's Name ............ :                   Shenzhen Huafurui Technology Co., Ltd.
                                                    Unit 1401 &1402, 14/F, Jin qi zhi gu mansion (No. 4 building of Chong
Address.................................. :         wen Garden), Crossing of the Liu xian street and Tang ling road, Tao
                                                    yuan street, Nan shan district, Shenzhen,P.R. China
Factory's Name                                      Shenzhen Huafurui Technology Co., Ltd.
                                                    Unit 1401 &1402, 14/F, Jin qi zhi gu mansion (No. 4 building of Chong
Address.................................. :         wen Garden), Crossing of the Liu xian street and Tang ling road, Tao
                                                    yuan street, Nan shan district, Shenzhen,P.R. China
Product description                                 Smart Phone
Brand Name                                          CUBOT
Mode Name                                           QUEST
Standards ............................. :        FCC Rules and Regulations Part 15B
This publication may be reproduced in whole or in part for non-commercial purposes as long as the Shenzhen
HUAK Testing Technology Co., Ltd. is acknowledged as copyright owner and source of the material. Shenzhen
HUAK Testing Technology Co., Ltd. takes no responsibility for and will not assume liability for damages
resulting from the reader's interpretation of the reproduced material due to its placement and context.
Date of Test ........................................... :
Date (s) of performance of tests ............. :                   Dec. 28, 2018~Jan. 09, 2019
Date of Issue .......................................... :         Feb. 18, 2019
Test Result .............................................. :       Pass



                               Testing Engineer                :

                                                                                   (Gary Qian)

                               Technical Manager               :

                                                                                   (Eden Hu)


                               Authorized Signatory :


                                                                               (Jason Zhou)


                           Page 3 of 23         Report No.: HK1812211958E




Revision    Issue Date           Revisions               Revised By
 V1.0      Feb. 18, 2019        Initial Issue           Jason Zhou


                                                                              Page 4 of 23                           Report No.: HK1812211958E



                                                            TABLE OF CONTENTS
1. SYSTEM DESCRIPTION ............................................................................................................................... 5
2. MEASUREMENT UNCERTAINTY ................................................................................................................. 6
3. PRODUCT INFORMATION............................................................................................................................ 7
4. SUPPORT EQUIPMENT ................................................................................................................................ 8
5. TEST FACILITY ............................................................................................................................................. 9
6. TEST ITEMS AND THE RESULTS .............................................................................................................. 10
7. FCCLINE CONDUCTED EMISSION TEST ................................................................................................. 11
   7.1. LIMITS OF LINE CONDUCTED EMISSION TEST..................................................................................11
   7.2. BLOCK DIAGRAM OF TEST SETUP .....................................................................................................11
   7.3. PROCEDURE OF LINE CONDUCTED EMISSION TEST ..................................................................... 12
   7.4. TEST RESULT OF LINE CONDUCTED EMISSION TEST .................................................................... 13
8. FCC RADIATED EMISSION TEST .............................................................................................................. 15
   8.1. EXCEPT FOR CLASS A DIGITAL DEVICES, THE FIELD STRENGTH OF RADIATED EMISSIONS
   FROM UNINTENTIONAL RADIATORS AT A DISTANCE OF 3 METERS SHALL NOT EXCEED THE
   FOLLOWING VALUES: ................................................................................................................................ 15
   8.2. BLOCK DIAGRAM OF TEST SETUP .................................................................................................... 16
   8.3. PROCEDURE OF RADIATED EMISSION TEST ................................................................................... 17
   8.4. TEST RESULT OF RADIATED EMISSION TEST .................................................................................. 18
APPENDIX A: PHOTOGRAPHS OF TEST SETUP ........................................................................................ 22


                                                     Page 5 of 23               Report No.: HK1812211958E



1. SYSTEM DESCRIPTION
 EUT test procedure:
   1. Connect EUT and peripheral devices (PC) through USB port.
   2. Power on the EUT, use the software to transfer data between EUT and PC.
   3. Make sure the EUT operates normally during the test.


 Test Mode
TEST MODE DESCRIPTION
 NO.                        TEST MODE DESCRIPTION                                       WORST
  1                    USB (connection for data transferring)                              V
Note:
1. V means EMI worst mode
2. USB cable is provided by AGC-Lab.


                                                    Page 6 of 23              Report No.: HK1812211958E



2. MEASUREMENT UNCERTAINTY
                                                                        Measurement
                                Test                                                             Notes
                                                                         Uncertainty
                 Transmitter power conducted                              ±0.57 dB                (1)
                  Transmitter power Radiated                              ±2.20 dB                (1)
           Conducted spurious emission 9KHz-40 GHz                        ±2.20 dB                (1)
                     Occupied Bandwidth                                   ±0.01ppm                (1)
               Radiated Emission 30~1000MHz                                ±4.10dB                (1)
                Radiated Emission Above 1GHz                               ±4.32dB                (1)
              Conducted Disturbance0.15~30MHz                              ±3.20dB                (1)

Note: This uncertainty represents an expanded uncertainty expressed at approximately the 95% confidence
level using a coverage factor of k=2.


                                                      Page 7 of 23            Report No.: HK1812211958E



3. PRODUCT INFORMATION
Housing Type                 Plastic and metal

Hardware Version             A799_MAIN_PCB_V1.1

Software Version             CUBOT_CUBOT_QUEST_8123C_V01_20181122
EUT Input Rating             DC3.85V by battery or DC 5V by Micro-USB


                         I/O Port Information (   Applicable     Not Applicable)

                                             I/O Port of EUT
         I/O Port Type                       Number                    Specific           Tested With
           USB Port                               1                  0.8 Unshielded            1


                                                    Page 8 of 23                 Report No.: HK1812211958E



4. SUPPORT EQUIPMENT
  Device Type       Manufacturer       Model Name       Serial No.     Data Cable         Power Cable
       PC            Lenovo Inc.             --              --             --                 --
    Adapter          Lenovo Inc.             --              --             --          1.25m Unshielded

Note: All the above equipment/cables were placed in worse case positions to maximize emission signals
during emission test.


                                                     Page 9 of 23            Report No.: HK1812211958E



5. TEST FACILITY
Site                     Shenzhen HUAK Testing Technology Co., Ltd.
                         1F, B2 Building, Junfeng Zhongcheng Zhizao Innovation Park, Fuhai Street, Bao'an
Location
                         District, Shenzhen City, China
Designation Number       CN1229
Test Firm Registration Number : 616276

TEST EQUIPMENT OF CONDUCTED EMISSION TEST
                         Conducted Emission Shielding Room Test Site (744)
       Equipment       Manufacturer         Model              S/N          Cal. Date        Cal. Due
        Receiver           R&S              ESCI 7          HKE-010       Dec. 27, 2018    Dec. 26, 2019
      LISN                 R&S             ENV216           HKE-002       Dec. 27, 2018    Dec. 26, 2019
  Conducted test                           TS+ Rev
                         Tonscend                           HKE-081            N/A             N/A
    software                                2.5.0.0


TEST EQUIPMENT OF RADIATED EMISSION TEST
       Equipment       Manufacturer         Model              S/N          Cal. Date        Cal. Due
        Receiver           R&S             ESCI-7           HKE-010       Dec. 27, 2018    Dec. 26, 2019
Spectrum analyzer         Agilent          N9020A           HKE-048       Dec. 27, 2018    Dec. 26, 2019
    Preamplifier          EMCI           EMC051845SE        HKE-015       Dec. 27, 2018    Dec. 26, 2019
    Preamplifier          Agilent          83051A           HKE-016       Dec. 27, 2018    Dec. 26, 2019
   Loop antenna        Schwarzbeck       FMZB 1519 B        HKE-014       Dec. 27, 2018    Dec. 26, 2019
Broadband antenna      Schwarzbeck        VULB 9163         HKE-012       Dec. 27, 2018    Dec. 26, 2019
   Horn antenna        Schwarzbeck          9120D           HKE-013       Dec. 27, 2018    Dec. 26, 2019
   Antenna Mast           Keleto           CC-A-4M             N/A             N/A             N/A
 Position controller    Taiwan MF          MF7802           HKE-011       Dec. 27, 2018    Dec. 26, 2019
   Radiated test                           TS+ Rev
                         Tonscend                           HKE-082            N/A             N/A
      software                              2.5.0.0
     RF cable
                          Times           381806-001           N/A             N/A             N/A
   (9KHz-1GHz)
     RF cable             Times             1-40G           HKE-034       Dec. 27, 2018    Dec. 26, 2019


                                       Page 10 of 23       Report No.: HK1812211958E



6. TEST ITEMS AND THE RESULTS
  Test item      Test Requirement          Test Method      Class/Severity   Result
 CONDUCTED
               FCC Part 15.107 Rules     ANSI C63.4:2014       Class B        Pass
  EMISSION
  RADIATED
               FCC Part 15.109 Rules     ANSI C63.4:2014       Class B        Pass
  EMISSION


                                                       Page 11 of 23                Report No.: HK1812211958E


7. FCCLINE CONDUCTED EMISSION TEST
7.1. LIMITS OF LINE CONDUCTED EMISSION TEST
                                                              Maximum RF Line Voltage
             Frequency
                                                   Q.P.( dBuV)                        Average( dBuV)
          150kHz-500kHz                               66-56                                 56-46
           500kHz-5MHz                                  56                                    46
            5MHz-30MHz                                  60                                    50

Note:
1. The lower limit shall apply at the transition frequency.
2. The limit decreases linearly with the logarithm of the frequency in the range 0.15 MHz to 0.50MHz.

7.2. BLOCK DIAGRAM OF TEST SETUP


                                                    Page 12 of 23              Report No.: HK1812211958E


7.3. PROCEDURE OF LINE CONDUCTED EMISSION TEST
(1) The equipment was set up as per the test configuration to simulate typical actual usage per the user’s
      manual. When the EUT is a tabletop system, a wooden table with a height of 0.8 meters is used and is
      placed on the ground plane as per ANSI C63.4 (see Test Facility for the dimensions of the ground plane
      used). When the EUT is a floor-standing equipment, it is placed on the ground plane which has a 3-12
      mm non-conductive covering to insulate the EUT from the ground plane.
(2) Support equipment, if needed, was placed as per ANSI C63.4.
(3) All I/O cables were positioned to simulate typical actual usage as per ANSI C63.4.
(4) The EUT received DC5V power from PC with receive AC120V/60Hz power from a LISN.
(5) The EUT test program was started. Emissions were measured on each current carrying line of the EUT
      using a spectrum Analyzer / Receiver connected to the LISN powering the EUT. The LISN has two
      monitoring points: Line 1 (Hot Side) and Line 2 (Neutral Side). Two scans were taken: one with Line 1
      connected to Analyzer / Receiver and Line 2 connected to a 50 ohm load; the second scan had Line 1
      connected to a 50 ohm load and Line 2 connected to the Analyzer / Receiver.
(6) Analyzer / Receiver scanned from 150 kHz to 30MHz for emissions in each of the test modes.
(7) During the above scans, the emissions were maximized by cable manipulation.
(8) A scan was taken on both power lines, Line 1 and Line 2, recording at least the six highest emissions.
(9) Emission frequency and amplitude were recorded into a computer in which correction factors were used
      to calculate the emission level and compare reading to the applicable limit. If EUT emission level was
      less –2dB to the A.V. limit in Peak mode, then the emission signal was re-checked using Q.P and
      Average detector.

    The test data of the worst case condition (mode 1) was reported on the Summary Data page.


                                         Page 13 of 23       Report No.: HK1812211958E


7.4. TEST RESULT OF LINE CONDUCTED EMISSION TEST
                            LINE CONDUCTED EMISSION TEST-L


                            Page 14 of 23       Report No.: HK1812211958E



               LINE CONDUCTED EMISSION TEST-N




RESULT: PASS


                                                       Page 15 of 23               Report No.: HK1812211958E


8. FCC RADIATED EMISSION TEST
8.1. EXCEPT FOR CLASS A DIGITAL DEVICES, THE FIELD STRENGTH OF RADIATED EMISSIONS
FROM UNINTENTIONAL RADIATORS AT A DISTANCE OF 3 METERS SHALL NOT EXCEED THE
FOLLOWING VALUES:
       Frequency                           Distance                      Maximum Field Strength Limit
         (MHz)                                (m)                              (dBuV/m/ Q.P.)
             30~88                              3                                    40.0
            88~216                              3                                    43.5
            216~960                             3                                    46.0
           Above 960                            3                                    54.0


Note: The lower limit shall apply at the transition frequency.
8.1.1 The following table is the setting of spectrum analyzer and receiver:
                Spectrum Parameter                                                Setting
                Start ~Stop Frequency                                  9KHz~150KHz/RB 200Hz for QP
                Start ~Stop Frequency                                 150KHz~30MHz/RB 9KHz for QP
                Start ~Stop Frequency                               30MHz~1000MHz/RB 120KHz for QP
                                                                              1GHz~26.5GHz
                Start ~Stop Frequency
                                                                 1MHz/1MHz for Peak, 1MHz/10Hz for Average


                Receiver    Parameter                                             Setting
                Start ~Stop Frequency                                  9KHz~150KHz/RB 200Hz for QP
                Start ~Stop Frequency                                 150KHz~30MHz/RB 9KHz for QP
                Start ~Stop Frequency                               30MHz~1000MHz/RB 120KHz for QP


                                              Page 16 of 23            Report No.: HK1812211958E


8.2. BLOCK DIAGRAM OF TEST SETUP
                    System Diagram of Connections between EUT and Simulators




                                                               1-4m

                            EUT         3m                               Amplifier



            0.8 m
                                                                         Spectrum
                                                                          Analyzer

                      RADIATED EMISSION TEST SETUP ABOVE 1000MHz


                                                      Page 17 of 23               Report No.: HK1812211958E


8.3. PROCEDURE OF RADIATED EMISSION TEST
  1. Configure the EUT according to ANSI C63.4. The EUT was placed on the top of the turntable 0.8 meter
     above ground. The phase center of the receiving antenna mounted on the top of a height-variable
     antenna tower was placed 3 meters far away from the turntable.
  2. Power on the EUT and all the supporting units. The turntable was rotated by 360 degrees to determine
     the position of the highest radiation.
  3. The height of the broadband receiving antenna was varied between one meter and four meters above
     ground to find the maximum emissions field strength of both horizontal and vertical polarization.
   4. For each suspected emissions, the antenna tower was scan (from 1 M to 4 M) and then the turntable was
      rotated (from 0 degree to 360 degrees) to find the maximum reading.
  5. Set the test-receiver system to Peak or CISPR quasi-peak Detect Function with specified bandwidth
     under Maximum Hold Mode.
  6. For emissions above 1GHz, use 1MHz RBW and 3MHz VBW for peak reading. Then 1MHz RBW and
     3MHz VBW for average reading in spectrum analyzer. The EUT was placed on the top of the turntable 0.8
     meter above ground. The phase center of the receiving antenna mounted on the top of a height-variable
     antenna tower was placed 3 meters far away from the turntable.
  7. When the radiated emissions limits are expressed in terms of the average value of the emissions, and
     pulsed operation is employed, the measurement field strength shall be determined by averaging over one
     complete pulse train, including blanking intervals, as long as the pulse train does not exceed 0.1 seconds.
     As an alternative (provided the transmitter operates for longer than 0.1 seconds) or in cases where the
     pulse train exceeds 0.1 seconds, the measured field strength shall be determined from the average
     absolute voltage during a 0.1 second interval during which the field strength is at its maximum values.
   8.If the emissions level of the EUT in peak mode was 3 dB lower than the average limit specified, then
      testing will be stopped and peak values of EUT will be reported, otherwise, the emissions which do not
      have 3 dB margin will be repeated one by one using the quasi-peak method for below 1GHz.
  9. If the emission level of the EUT in peak mode was 10 dB lower than the limit specified, then testing could
     be stopped and the peak values of the EUT would be reported. Otherwise the emissions that did not have
     10 dB margin would be re-tested one by one using peak, quasi-peak or average method as specified and
     then reported in a data sheet.
 10. In case the emission is lower than 30MHz, loop antenna has to be used for measurement and the
       recorded data should be QP measured by receiver. High - Low scan is not required in this case.
 11. The test data of the worst case condition (mode 1) was reported on the Summary Data page.


                                         Page 18 of 23       Report No.: HK1812211958E


8.4. TEST RESULT OF RADIATED EMISSION TEST
                  RADIATED EMISSION TEST AT 3M DISTANCE-HORIZONTAL




RESULT: PASS


                                                   Page 19 of 23              Report No.: HK1812211958E



                        RADIATED EMISSION TEST AT 3M DISTANCE-VERTICAL




RESULT: PASS
Note: 1.Measurement = Reading + Factor, Over = Measurement – Limit.
     2. The “Factor” value can be calculated automatically by software of measurement system.


                            Page 20 of 23        Report No.: HK1812211958E



RADIATED EMISSION ABOVE 1GHZ TEST AT 3M DISTANCE –HORIZONTAL


                                                   Page 21 of 23              Report No.: HK1812211958E



                RADIATED EMISSION ABOVE 1GHZ TEST AT 3M DISTANCE –VERTICAL




Note: 1. Emissions range from 6GHz to 12.5GHz have 20dB margin. No recording in the test report.
      2. Factor=Antenna Factor + Cable loss - Amplifier gain, Margin=Measurement-Limit.
      3. The “Factor” value can be calculated automatically by software of measurement system.


                   Page 22 of 23           Report No.: HK1812211958E



APPENDIX A: PHOTOGRAPHS OF TEST SETUP
  FCC LINE CONDUCTED EMISSION TEST SETUP




     FCC RADIATED EMISSION TEST SETUP


              Page 23 of 23        Report No.: HK1812211958E



FCC RADIATED EMISSION TEST SETUP




     ----END OF REPORT----