Test Report

FCC ID: 2AHVH43345806

Test Report

Download: PDF
FCCID_4145029

        A
  Ga CTC Laboratories, Inc.
     1—2/F., Building 2, Jiaquan Building, Guanlan High—Tech Park, Shenzhen, Guangdong, China
     Tel : +86—755—27521059
     Fax: +86—755—27521011




                                    EMC TEST REPORT
Product name........................... : LED TV

Trad@Ma@rk.................lcccclll.}}. : AMTC, Hitachi

Model Name............................. : MUAV4360Y—34580

Adding Model ........................... : MUAVA43**Y—34580 (* can from 0 to 9,A to Z ); 43C61, C43M6

Test Standards ......................... : FCC CFR Title 47 Part 15 Subpart B

FCC ID...2....n0ncccnerere en eeeks : 2AHVH43345806

R@pOFt MO. ...z : GTI20190096F

APPIIC@Nt ...............cccceeeke : Shen Zhen MTC Co.,LTD
Address of applicant .............. :_MTC Industry Park, 1st Lilang Road, Xialilang community, Nanwan
                                      street, Longgang district, Shenzhen, China
Date of Receipt................_. : Jan. 16, 2019

Date of Test Date...................... : Jan. 16, 2019 to Jan. 21, 2019

Date Of ISSU@. ......................l.l}. : Jan. 21, 2019


    T@St F@SUIt........cceeneneeneeneenenrrenees : Pass *

    * In the configuration tested, the EUT complied with the standards specified above




                                                                                                C
   The FCC mark as shown above can be used, under the responsibility of the manufacturer, all necessary
   steps have been enforced to assure that all production units of the same equipment will continue to comply
   with the Federal Communications Commission‘s requirements.




                                                                                       CTC Laboratories, Inc.
                                     1—2/F., Building 2, Jiaquan Building, Guanlan High—Tech Park, Shenzhen, Guangdong, China
                                            Tel.: (86)755—27521059                   Fax.: (86)755—27521011         Hittp://www.sz—ctc.org.cn
  n PERxXWIATLkKEREEERA
    Certfication and Accredtation Adrminitration of the People‘s Republic of China
                                                                                     For anti—fake verification, please visit the official website of Certification and
                                                                                     Accreditation Administration of the People‘s Republic of China : yz.cncaic.ch


      A
pclos
                                                                                             Page 2 of 34                          Report No.: GTI20190096F




                   GENERAL DESCRIPTION OF EUT
                   Equipment                                               LED TV
                   Model Name                                              MUAV4360Y—34580
                   Adding Model                                            MUAV43**Y—34580 (* can from 0 to 9,A to Z); 43C61, C43M6
                   Model Difference                                        Just different colors and trademarks, the other is the same
                   Manufacturer                                            Shen Zhen MTC Co.,LTD
                                                                           MTC Industry Park, 1st Lilang Road, Xialilang community,
                   Manufacturer Address
                                                                           Nanwan street, Longgang district, Shenzhen, China
                   Factory                                                 Shen Zhen MTC Co.,LTD
                                                                          MTC Industry Park, 1st Lilang Road, Xialilang community,
                   Factory Address
                                                                          Nanwan street, Longgang district, Shenzhen, China
                                                                          Based on the application, features, or specification exhibited
                                                                          in User‘s Manual, the EUT is considered as as both an ITE
                   Product Description                                    /Computing Device & a Sound and Television Broadcast
                                                                          Receiver. More details of EUT technical specification, please
                                                                           refer to the User‘s Manual.
                   Power Rating                                            INPUT: AC100—240V, 78W, 50/60Hz




                                                         Compiled By:                            ) in               )0""‘3

                                                                                                           (Jim Jiang)


                                                         Reviewed By:                                    O’”“jbwo

                                                                                                           (Cary Luo)



                                                         Approved By:
                                                                                                        ( 1 Allér~ CH’/;'IL_J
                                                                                                      «[A


                                                                                                         (Walter Chen)

This test report may be duplicated completely for legal use with the approval of the applicant. It should not be
reproduced except in full, without the written approval of our laboratory. The client should not use it to claim
product endorsement by CTC. The test results in the report only apply to the tested sample. The test report
shall be invalid without all the signatures of testing engineers, reviewer and approver. Any objections must
be raised to CTC within 15 days since the date when the report is received. It will not be taken into
consideration beyond this limit.




                                                                                     CTC Laboratories, Inc.
                                   1—2/F., Building 2, Jiaquan Building, Guanlan High—Tech Park, Shenzhen, Guangdong, China
                                          Tel.: (86)755—27521059                   Fax.: (86)755—27521011         Hittp://www.sz—ctc.org.cn
n PERxXWIATLkKEREEERA
  Certfication and Accrediation Adrminitration of the People‘s Republic of China
                                                                                   For anti—fake verification, please visit the official website of Certification and
                                                                                   Accreditation Administration of the People‘s Republic of China : yz.cncaic.ch


                                                                                    Page 3 of 34                                 Report No.: GTI20190096F



                                                                   Table of Contents                                                                         Page


1       TEST SUMMARY........................................................................................................................................... 4
     TEST PROCEDURES ACCORDING TO THE TECHNICAL STANDARDS: ............................................................................. 4
     1.1    TEST FACILITY ............................................................................................................................................. 5
     1.2    MEASUREMENT UNCERTAINTY ............................................................................................................. 5
2       GENERAL INFORMATION ......................................................................................................................... 6
     2.1        DESCRIPTION OF TEST MODES ............................................................................................................... 6
     2.2        DESCRIPTION TEST PERIPHERAL AND EUT PERIPHERAL .............................................................. 7
     2.3        MEASUREMENT INSTRUMENTS EQUIPMENTS LIST ........................................................................ 8
3       CONDUCTED EMISSION MEASUREMENT ........................................................................................... 9
     3.1        LIMITS OF CONDUCTED EMISSION .................................................................................................................. 9
     3.2        TEST PROCEDURE ..................................................................................................................................... 10
     3.3        TEST SETUP ................................................................................................................................................. 10
     3.4        EUT OPERATING CONDITIONS .............................................................................................................. 10
     3.5        TEST RESULTS ............................................................................................................................................ 11
4       RADIATED EMISSION MEASUREMENT .............................................................................................. 13
     4.1        LIMITS OF RADIATED EMISSION MEASUREMENT.......................................................................... 13
     4.2        TEST PROCEDURE ..................................................................................................................................... 13
     4.3        TEST SETUP ................................................................................................................................................. 14
     4.4        EUT OPERATING CONDITIONS .............................................................................................................. 14
     4.5        TEST RESULTS ............................................................................................................................................ 15
5       ANTENNA POWER CONDUCTION MEASUREMENT ........................................................................ 19
6       ANTENNA POWER CONDUCTION MEASUREMENT ........................................................................ 21
7       PICTURE SENSITIVITY MEASUREMENT............................................................................................ 23
8       NOISE FIGURE MEASUREMENT ........................................................................................................... 24
9       EUT TEST PHOTO ...................................................................................................................................... 25
10      ATTACHMENT PHOTOGRAPHS OF EUT ..............................................................................................27




                                                                  CTC Laboratories, Inc.
                              1-2/F., Building 2, Jiaquan Building, Guanlan High-Tech Park, Shenzhen, Guangdong, China
                                   Tel.: (86)755-27521059       Fax.: (86)755-27521011         Http://www.sz-ctc.org.cn
                                                                For anti-fake verification, please visit the official website of Certification and
                                                                Accreditation Administration of the People’s Republic of China : yz.cncaic.cn


                                                              Page 4 of 34                        Report No.: GTI20190096F



1   TEST SUMMARY

    Test procedures according to the technical standards:


             Test                                  Standard                              Class              Result          Remark

    Conducted Emission               FCC Part 15 Section 15.107                        Class B              PASS                ---

     Radiated Emission               FCC Part 15 Section 15.109                        Class B              PASS                ---
       Antenna Power
                                      FCC Part 15 Section 15.111                       Class B              PASS                ---
        Conduction
      Picture Sensitivity           FCC Part 15 Section 15.117(f)                      Class B              PASS                ---

         Noise figure              FCC Part 15 Section 15.117(g)                       Class B              PASS                ---

Both conducted and radiated emission tests were performed according to the procedures in ANSI
C63.4: 2014. Test results are in compliance with the requirements of FCC Part 15: 2017.

The EUT setup configuration please refers to the photo of test configuration in item.




                                                     CTC Laboratories, Inc.
                 1-2/F., Building 2, Jiaquan Building, Guanlan High-Tech Park, Shenzhen, Guangdong, China
                      Tel.: (86)755-27521059       Fax.: (86)755-27521011         Http://www.sz-ctc.org.cn
                                                   For anti-fake verification, please visit the official website of Certification and
                                                   Accreditation Administration of the People’s Republic of China : yz.cncaic.cn


                                                           Page 5 of 34                        Report No.: GTI20190096F



1.1   TEST FACILITY
 CTC Laboratories, Inc.
 Add. :
 1-2F., Building 2, Jiaquan Building, Guanlan High-Tech Park, Shenzhen, Guangdong, China

 ISED Registration No.: CN0029
 The 3m alternate test site of CTC Laboratories, Inc.EMC Laboratory has been registered by
 Certification and Engineer Bureau of Industry Canada for the performance of with Registration
 NO.: CN0029 on Dec, 2018.

 FCC-Registration No.: CN1208
 CTC Laboratories, Inc. EMC Laboratory has been registered and fully described in a report filed
 with the (FCC) Federal Communications Commission. The acceptance letter from the FCC is
 maintained in our files. Registration CN1208, Sep 07, 2017

 1.2 MEASUREMENT UNCERTAINTY
 The reported uncertainty of measurement y ± U,where expended uncertainty U is based on a
 standard uncertainty multiplied by a coverage factor of                    k=2,providing a level of confidence of
 approximately 95 %。

 A. Conducted Measurement :
     Test Site Method  Measurement Frequency Range                                     U,(dB)                  NOTE
     GTIC01     ANSI        150 KHz ~ 30MHz                                             3.2                      /

 B. Radiated Measurement :
    Test Site Method     Measurement Frequency Range                                   U,(dB)                  NOTE
                              30MHz ~ 1000MHz                                           3.5                      /
     GTIA01    ANSI
                                1GHz ~ 6GHz                                             5.2                      /




                                                  CTC Laboratories, Inc.
              1-2/F., Building 2, Jiaquan Building, Guanlan High-Tech Park, Shenzhen, Guangdong, China
                   Tel.: (86)755-27521059       Fax.: (86)755-27521011         Http://www.sz-ctc.org.cn
                                                For anti-fake verification, please visit the official website of Certification and
                                                Accreditation Administration of the People’s Republic of China : yz.cncaic.cn


                                                            Page 6 of 34                        Report No.: GTI20190096F



2   GENERAL INFORMATION
2.1 DESCRIPTION OF TEST MODES
       As the function of the EUT, test mode selected to test as below to conform this standard.

                test Mode                                              Description
                  Mode 1                                                   AV IN
                  Mode 2                                                   HDMI
                  Mode 3                                                   USB
                  Mode 4                                                   NTSC
                  Mode 5                                                   ATSC

Note:
Pre-scan above all test mode and voltage(120Vac/60Hz and 230Vac/50Hz), found below test mode
and voltage which it was worse case mode.

                                         Worse case operation Test                    Worse case operation Test
              Test item
                                                  mode                                        Voltage
        Conducted emission                             Mode 2                                    120V/60Hz
         Radiated emission                             Mode 2                                    120V/60Hz
          Antenna Power
                                                 Mode 4/ Mode 5                                  120V/60Hz
            Conduction
         Picture Sensitivity                           Mode 4                                    120V/60Hz
            Noise figure                               Mode 4                                    120V/60Hz




                                                   CTC Laboratories, Inc.
               1-2/F., Building 2, Jiaquan Building, Guanlan High-Tech Park, Shenzhen, Guangdong, China
                    Tel.: (86)755-27521059       Fax.: (86)755-27521011         Http://www.sz-ctc.org.cn
                                                 For anti-fake verification, please visit the official website of Certification and
                                                 Accreditation Administration of the People’s Republic of China : yz.cncaic.cn


                                                            Page 7 of 34                        Report No.: GTI20190096F



2.2 DESCRIPTION TEST PERIPHERAL AND EUT PERIPHERAL
 The EUT has been tested as an independent unit together with other necessary accessories or
 support units. The following support units or accessories were used to form a representative test
 configuration during the tests.

  Item      Equipment                   Mfr/BrandModel/Type No.                                  Series No.                  Note
                                                MHAV2260Y-355
  E-1        LED TV               AMTC, HITACHI                                                      N/A                     EUT
                                                      3H
  E-2          PC                           HP                     P7-1035cn                  4CV125C15J                      AE
  E-3          DVD                         GIEC                      GK-901                          N/A                      AE
  E-4     TV Generator                  DTV tool                       DTV                           N/A                      AE
  E-5         Printer                       HP                       P1007                    VNFN584036                      AE
  E-6       USB Disk                    Kingston                DT101G2/8GB                        253394                     AE

  Item     Shielded Type           Ferrite Core              Length                                     Note
  C-1           NO                      NO                   120cm                                    AC Line
  C-2           NO                      NO                   150cm                                    AV Line
  C-3          YES                      YES                  150cm                                  HDMI Line
  C-4          YES                      YES                  150cm                                    TV Line

  Note:
    (1)   The support equipment was authorized by Declaration of Confirmation.
    (2)   For detachable type I/O cable should be specified the length in cm in『Length』column.
    (3)   “YES” is means “shielded” “with core”; “NO” is means “unshielded” “without core”.




                                                   CTC Laboratories, Inc.
               1-2/F., Building 2, Jiaquan Building, Guanlan High-Tech Park, Shenzhen, Guangdong, China
                    Tel.: (86)755-27521059       Fax.: (86)755-27521011         Http://www.sz-ctc.org.cn
                                                 For anti-fake verification, please visit the official website of Certification and
                                                 Accreditation Administration of the People’s Republic of China : yz.cncaic.cn


                                                             Page 8 of 34                        Report No.: GTI20190096F



2.3 MEASUREMENT INSTRUMENTS EQUIPMENTS LIST

                                          Conducted Emission
Item    Test Equipment           Manufacturer     Model No.                            Serial No.             Calibrated until
  1          LISN                   R&S            ENV216                               101112                Dec. 28, 2019
  2          LISN                   R&S            ENV216                               101113                Dec. 28, 2019
  3    EMI Test Receiver            R&S             ESCI                                100920                Dec. 28, 2019
  4       ISN CAT6               Schwarzbeck     NTFM 8158                             8158-0046              Dec. 28, 2019

                                           Radiated Emission
Item  Test Equipment             Manufacturer      Model No.                            Serial No.            Calibrated until
  1    Bilog Antenna             Schwarzbeck      CBL6141A                                4180                Dec. 28, 2019
  2  Spectrum Analyzer              R&S             FSU26                                100105               Dec. 28, 2019
  3    Horn Antenna              Schwarzbeck     BBHA 9120D                               647                 Dec. 28, 2019
        Low Noise
  4                                      HP                      8447D                1937A03050               Dec. 28, 2019
       Pre-Amplifier
        Low Noise
  5                                    EMCI                  EMC051835                    980075               Dec. 28, 2019
       Pre-Amplifier
  6    Test Receiver                    R&S                      ESCI7                    100967               Dec. 28, 2019
  7    Antenna Mast                     UC                      UC3000                     N/A                      N/A
  8     Turn Table                      UC                      UC3000                     N/A                      N/A

                   Antenna Power Conduction& Picture Sensitivity& Noise figure
Item    Test Equipment      Manufacturer     Model No.          Serial No.                                     Calibrated until
  1    EMI Test Receiver       R&S              ESCI             100920                                        Dec. 28, 2019
  2    Spectrum Analyzer       R&S             FSU26             100105                                        Dec. 28, 2019
         Digital signal
 3                             R&S             SFC-U               N/A                                         Dec. 28, 2019
           generator
         Analog signal                     YQ-70C-1052
 4                            PHILIPS                              N/A                                         Dec. 28, 2019
           generator                         (PM5418)

The Cal. Interval was one year.




                                                    CTC Laboratories, Inc.
                1-2/F., Building 2, Jiaquan Building, Guanlan High-Tech Park, Shenzhen, Guangdong, China
                     Tel.: (86)755-27521059       Fax.: (86)755-27521011         Http://www.sz-ctc.org.cn
                                                  For anti-fake verification, please visit the official website of Certification and
                                                  Accreditation Administration of the People’s Republic of China : yz.cncaic.cn


                                                                 Page 9 of 34                        Report No.: GTI20190096F



3     CONDUCTED EMISSION MEASUREMENT

     3.1 Limits of Conducted Emission

                                                Class A (dBuV)                                     Class B (dBuV)
       FREQUENCY (MHz)
                                        Quasi-peak               Average               Quasi-peak                    Average
             0.15 -0.5                      79.00                  66.00                 66 - 56 *                   56 - 46 *
             0.50 -5.0                      73.00                  60.00                   56.00                       46.00
             5.0 -30.0                      73.00                  60.00                   60.00                       50.00
           Note:
             (1) The tighter limit applies at the band edges.
             (2) The limit of " * " marked band means the limitation decreases linearly with the
                 logarithm of the frequency in the range.

    The following table is the setting of the receiver
                  Receiver Parameters                                                              Setting
                       Attenuation                                                                  10 dB
                     Start Frequency                                                              0.15 MHz
                     Stop Frequency                                                                30 MHz
                      IF Bandwidth                                                                  9 kHz




                                                        CTC Laboratories, Inc.
                    1-2/F., Building 2, Jiaquan Building, Guanlan High-Tech Park, Shenzhen, Guangdong, China
                         Tel.: (86)755-27521059       Fax.: (86)755-27521011         Http://www.sz-ctc.org.cn
                                                      For anti-fake verification, please visit the official website of Certification and
                                                      Accreditation Administration of the People’s Republic of China : yz.cncaic.cn


                                                           Page 10 of 34                         Report No.: GTI20190096F



 3.2 TEST PROCEDURE
 a. The EUT was placed 0.8 meters from the horizontal ground plane with EUT being connected
    to the power mains through a line impedance stabilization network (LISN). All other support
    equipments powered from additional LISN(s). The LISN provide 50 Ohm/ 50uH of coupling
    impedance for the measuring instrument.
 b. Interconnecting cables that hang closer than 40 cm to the ground plane shall be folded back
    and forth in the center forming a bundle 30 to 40 cm long.
 c. I/O cables that are not connected to a peripheral shall be bundled in the center. The end of the
    cable may be terminated, if required, using the correct terminating impedance. The overall
    length shall not exceed 1 m.
 d. LISN at least 80 cm from nearest part of EUT chassis.
 e. For the actual test configuration, please refer to the related Item –EUT Test Photos.


 3.3 TEST SETUP




 3.4 EUT OPERATING CONDITIONS
The EUT tested system was configured as the statements of 2.1 Unless otherwise a special
operating condition is specified in the follows during the testing.




                                                  CTC Laboratories, Inc.
              1-2/F., Building 2, Jiaquan Building, Guanlan High-Tech Park, Shenzhen, Guangdong, China
                   Tel.: (86)755-27521059       Fax.: (86)755-27521011         Http://www.sz-ctc.org.cn
                                                For anti-fake verification, please visit the official website of Certification and
                                                Accreditation Administration of the People’s Republic of China : yz.cncaic.cn


 A
pclos
                                                                                                Page 11 of 34                                    Report No.: GTI20190096F




 3.5 TEST RESULTS

Temperature :                          |23°C                                                            Relative Humidity : |56%
Pressure :                              101 Kpa                                                        Test Mode :                           Mode 2
Test Voltage:                          AC 120V/60Hz                                                     Phase :                              L


            120 7


            100 +


               m 4




     %         eo \\                                                                                                       FCCPart 15 ClasslB Voltage on Mains QP

     2               PtySreak,                                                                                             ECC Part15ClasgBVoltageon MainsAV..

     § =7                                                                                                                                                                     +


             20                  1              i——————t—                               1                t             i————t—t—t—t                                    1       1
                 150k                       300 400 500                            800 1M              2M             3M 4M SM 6                 8 10M                20M     30M
                                                                                                Frequency in Hz

 Final Measurement Detector 1
   Frequency                   QuasiPeak                    Meas. Time                 Bandwidth             Filter        Line     Corr.        Margin     Limit          Comment
      (MHz)                          (dBuV)                        (ms)                     (kHz)                                    (dB)         (dB)      (dBu
                                                                                                                                                             V)
   13.202480                                 37.7                 1000.000                     9.000         Off           L1        10.2          22.3      |_60.0
   13.415200                                 37.0                 1000.000                     9.000         Off           L1        10.2          23.0      |_60.0
   29951690                                  37.6                 1000.000                     9.000         Off           L1        10.1          224       |_60.0


 Final Measurement Detector 2
   Frequency                   Average                 Meas. Time                    Bandwidth         Filter         Line        Corr.     Margin        Limit       Comment
      (MHz)                     (dBuV)                        (ms)                     (kHz)                                      (dB)       (dB)         (dBp
                                                                                                                                                           V)
    13.415200                           31.3                 1000.000                       9.000      Off            L1           10.2          18.7     50.0
    13.685940                           31.2                 1000.000                       9.000      Off            L1           10.2          18.8     50.0
    13.990060                           33.2                 1000.000                       9.000      Off            L1           10.2          16.8     50.0




                                                                                       CTC Laboratories, Inc.
                              1—2/F., Building 2, Jiaquan Building, Guanlan High—Tech Park, Shenzhen, Guangdong, China
                                      Tel.: (86)755—27521059                         Fax.: (86)755—27521011         Hittp://www.sz—ctc.org.cn
GpEaesyuircese
  Certfication and Accrediation Adrminitration of the People‘s Republic of China
                                                                                     For anti—fake verification, please visit the official website of Certification and
                                                                                     Accreditation Administration of the People‘s Republic of China : yz.cncaic.ch


Ea                                                                       Page 12 of 34                                     Report No.: GTI20190096F




Temperature :             |23°C                                                   Relative Humidity : |56%
Pressure :                 101 Kpa                                                Test Mode :                             Mode 2
Test Voltage:             AC 120V/60Hz                                            Phase :                                 N


           120 1


           100 +


            m_.




    ;:-L    60-5\\                                                                                  ECCPart 15 Class|B Voitage on Maihs QP

    B
    Q
                 [UYfSreuk,,
                 1|
                                                                                                    ECC Part15ClasgBVoltageon MainsAV..
                                     M P ingu a a d a uo wfi mm f m a mm o n mm un m ul um n m a ol m a i m o ms1




    5 *                                                                                                                                                    +
           m,,




             0__




           —20        1——t——————i——t——t—t——                                        :                ——t———t—t——t                                      i———I
             150k            300 400 500             800 1M                      2M             3M      4M 5M 6               8 10M                  20M   30M
                                                                         Frequency in Hz

 Final Measurement Detector 1
   Frequency          QuasiPeak       Meas. Time              Bandwidth                Filter       Line      Corr.        Margin       Limit          Comment
     (MHz)              (dBuV)             (ms)                   (kHz)                                       (dB)            (dB)      (dBu
                                                                                                                                         V)
   11.319860                 34.2        1000.000                      9.000           Off          N              9.7         25.8         60.0
   13.795750                 37.7        1000.000                      9.000           Off          N              9.7         22.3         |_60.0
   29.891910                 36.6        1000.000                      9.000           Off          N              9.7         234          60.0


 Final Measurement Detector 2
   Frequency          Average       Meas. Time            Bandwidth             Filter          Line       Corr.         Margin       Limit          Comment
     (MHz)             (dBuV)          (ms)                 (kHz)                                          (dB)           (dB)        (dBu
                                                                                                                                       V)
   11.365180               29.1       1000.000                    9.000         Off             N            9.7           20.9       |__50.0
   13.962130               33.0       1000000                     9.000         Off             N            9.7           17.0       50.0
   29.891910               30.2       1000.000                    9.000         Off             N            9.7           19.8       50.0




                                                              CTC Laboratories, Inc.
                      1—2/F., Building 2, Jiaquan Building, Guanlan High—Tech Park, Shenzhen, Guangdong, China
                          Tel.: (86)755—27521059           Fax.: (86)755—27521011         Hittp://www.sz—ctc.org.cn
GpEaesyuircese
  Mnooenee
                                                           For anti—fake verification, please visit the official website of Certification and
                                                           Accreditation Administration of the People‘s Republic of China : yz.cncaic.ch


                                                               Page 13 of 34                         Report No.: GTI20190096F



4     RADIATED EMISSION MEASUREMENT

     4.1 LIMITS OF RADIATED EMISSION MEASUREMENT
    LIMITS OF RADIATED EMISSION MEASUREMENT                                            (Below 1000MHz)

                                                          Class A (at 10m)                             Class B (at 3m)
           FREQUENCY (MHz)
                                                                dBuV/m                                      dBu /m
                  30 ~ 88                                          39.0                                        40.0
                 88 ~ 216                                          43.5                                        43.5
                216 ~ 960                                          46.5                                        46.0
                Above 960                                          49.5                                        54.0
    LIMITS OF RADIATED EMISSION MEASUREMENT                                            (Above 1000MHz)

                                          Class A (at 3m) dBuV/m                             Class B (at 3m) dBuV/m
      FREQUENCY (MHz)
                                            Peak                      Avg                     Peak                       Avg
           Above 1000                         80                       60                       74                        54
         Notes:
            (1) The limit for radiated test was performed according to as following:
                FCC PART 15B
            (2) The tighter limit applies at the band edges.
            (3) Emission level (dBuV/m)=20log Emission level (uV/m).

     4.2 TEST PROCEDURE
     a. The measuring distance of at 3 m shall be used for measurements at frequency up to 1GHz.
        For frequencies above 1GHz, any suitable measuring distance may be used.
     b. The EUT was placed on the top of a rotating table 0.8 meters above the ground at a 3 meter
        test site. The table was rotated 360 degrees to determine the position of the highest radiation.
     c. The height of the equipment or of the substitution antenna shall be 0.8 m; the height of the test
        antenna shall vary between 1 m to 4 m. Both horizontal and vertical polarizations of the
        antenna are set to make the measurement.
     d. The initial step in collecting radiated emission data is a spectrum analyzer peak detector mode
        pre-scanning the measurement frequency range. Significant peaks are then marked and then
        Quasi Peak detector mode re-measured, above 1G Average detector mode will be instead.
     e. If the Peak Mode measured value compliance with and lower than Quasi Peak Mode Limit, the
        EUT shall be deemed to meet QP(AV) Limits and then no additional QP Mode measurement
        performed.
     f. For the actual test configuration, please refer to the related Item –EUT Test Photos.

    Remarks:
    1.Factor (dB/m) = Antenna Factor (dB/m)+Cable Factor (dB)-Pre-amplifier Factor
    2.Margin value = Level - Limit value




                                                      CTC Laboratories, Inc.
                  1-2/F., Building 2, Jiaquan Building, Guanlan High-Tech Park, Shenzhen, Guangdong, China
                       Tel.: (86)755-27521059       Fax.: (86)755-27521011         Http://www.sz-ctc.org.cn
                                                    For anti-fake verification, please visit the official website of Certification and
                                                    Accreditation Administration of the People’s Republic of China : yz.cncaic.cn


                                                          Page 14 of 34                         Report No.: GTI20190096F


 4.3 TEST SETUP

(A) Radiated Emission Test Set-up, Frequency Below 1000MHz




(B) Radiated Emission Test Set-up, Frequency Above 1GHz




 4.4 EUT OPERATING CONDITIONS
The EUT tested system was configured as the statements of 2.1 Unless otherwise a special
operating condition is specified in the follows during the testing.




                                                 CTC Laboratories, Inc.
             1-2/F., Building 2, Jiaquan Building, Guanlan High-Tech Park, Shenzhen, Guangdong, China
                  Tel.: (86)755-27521059       Fax.: (86)755-27521011         Http://www.sz-ctc.org.cn
                                               For anti-fake verification, please visit the official website of Certification and
                                               Accreditation Administration of the People’s Republic of China : yz.cncaic.cn


                                                             Page 15 of 34                         Report No.: GTI20190096F


 4.5 TEST RESULTS
Temperature:         24℃                                           Relative Humidity: 57%
Pressure:            101 Kpa                                       Test Mode:                    Mode 2
Polarization:        Vertical                                      Test Power:                   AC 120V/60Hz




                                                       30~1000MHz




                                                    CTC Laboratories, Inc.
                1-2/F., Building 2, Jiaquan Building, Guanlan High-Tech Park, Shenzhen, Guangdong, China
                     Tel.: (86)755-27521059       Fax.: (86)755-27521011         Http://www.sz-ctc.org.cn
                                                  For anti-fake verification, please visit the official website of Certification and
                                                  Accreditation Administration of the People’s Republic of China : yz.cncaic.cn


                                             Page 16 of 34                         Report No.: GTI20190096F




                                     1000~6000MHz




                                    CTC Laboratories, Inc.
1-2/F., Building 2, Jiaquan Building, Guanlan High-Tech Park, Shenzhen, Guangdong, China
     Tel.: (86)755-27521059       Fax.: (86)755-27521011         Http://www.sz-ctc.org.cn
                                  For anti-fake verification, please visit the official website of Certification and
                                  Accreditation Administration of the People’s Republic of China : yz.cncaic.cn


                                                             Page 17 of 34                         Report No.: GTI20190096F



Temperature:         24℃                                           Relative Humidity: 57%
Pressure:            101 Kpa                                       Test Mode:                    Mode 2
Polarization:        Horizontal                                    Test Power:                   AC 120V/60Hz




                                                       30~1000MHz




                                                    CTC Laboratories, Inc.
                1-2/F., Building 2, Jiaquan Building, Guanlan High-Tech Park, Shenzhen, Guangdong, China
                     Tel.: (86)755-27521059       Fax.: (86)755-27521011         Http://www.sz-ctc.org.cn
                                                  For anti-fake verification, please visit the official website of Certification and
                                                  Accreditation Administration of the People’s Republic of China : yz.cncaic.cn


                                             Page 18 of 34                         Report No.: GTI20190096F




                                      1000~6000MHz




                                    CTC Laboratories, Inc.
1-2/F., Building 2, Jiaquan Building, Guanlan High-Tech Park, Shenzhen, Guangdong, China
     Tel.: (86)755-27521059       Fax.: (86)755-27521011         Http://www.sz-ctc.org.cn
                                  For anti-fake verification, please visit the official website of Certification and
                                  Accreditation Administration of the People’s Republic of China : yz.cncaic.cn


                                                             Page 19 of 34                         Report No.: GTI20190096F



5    Antenna Power Conduction Measurement

    Test Mode: Mode 4
                Frequency            Measured Frequency                    Reading                Limit              Margin
     Channel
                  (MHz)                    (MHz)                           (dBµV)                (dBµV)               (dB)
                 101.000                  101.000                           <30.0                 50.0               <-20.0
         2
                 202.000                  202.000                           <30.0                 50.0               <-20.0
                 107.000                  107.000                           <30.0                 50.0               <-20.0
         3
                 214.000                  214.000                           <30.0                 50.0               <-20.0
                 113.000                  113.000                           <30.0                 50.0               <-20.0
         4
                 226.000                  226.000                           <30.0                 50.0               <-20.0
                 123.000                  123.000                           <30.0                 50.0               <-20.0
         5
                 246.000                  246.000                           <30.0                 50.0               <-20.0
                 129.000                  129.000                           <30.0                 50.0               <-20.0
         6
                 258.000                  258.000                           <30.0                 50.0               <-20.0
                 221.000                  221.000                           <30.0                 50.0               <-20.0
         7
                 442.000                  442.000                           <30.0                 50.0               <-20.0
                 227.000                  227.000                           <30.0                 50.0               <-20.0
         8
                 454.000                  454.000                           <30.0                 50.0               <-20.0
                 233.000                  233.000                           <30.0                 50.0               <-20.0
         9
                 466.000                  466.000                           <30.0                 50.0               <-20.0
                 239.000                  239.000                           <30.0                 50.0               <-20.0
        10
                 478.000                  478.000                           <30.0                 50.0               <-20.0
                 245.000                  245.000                           <30.0                 50.0               <-20.0
        11
                 490.000                  490.000                           <30.0                 50.0               <-20.0
                 251.000                  251.000                           <30.0                 50.0               <-20.0
        12
                 502.000                  502.000                           <30.0                 50.0               <-20.0

Note: Negative signs (-) in the margin column signify levels below the limit.
     Limit (50 dBµV) was converted from the limit (2nW) at the 50Ω measurement impedance.




                                                    CTC Laboratories, Inc.
                1-2/F., Building 2, Jiaquan Building, Guanlan High-Tech Park, Shenzhen, Guangdong, China
                     Tel.: (86)755-27521059       Fax.: (86)755-27521011         Http://www.sz-ctc.org.cn
                                                  For anti-fake verification, please visit the official website of Certification and
                                                  Accreditation Administration of the People’s Republic of China : yz.cncaic.cn


                                                          Page 20 of 34                         Report No.: GTI20190096F



Test Mode: Mode 4
            Frequency                    Measured                       Reading                Limit              Margin
 Channel
               (MHz)                  Frequency(MHz)                    (dBµV)                (dBµV)               (dB)
              257.000                     257.000                        <30.0                 50.0               <-20.0
    13
              514.000                     514.000                        <30.0                 50.0               <-20.0
              517.000                     517.000                        <30.0                 50.0               <-20.0
    14
             1034.000                    1034.000                        <30.0                 50.0               <-20.0
              523.000                     523.000                        <30.0                 50.0               <-20.0
    15
             1046.000                    1046.000                        <30.0                 50.0               <-20.0
              553.000                     553.000                        <30.0                 50.0               <-20.0
    20
             1106.000                    1106.000                        <30.0                 50.0               <-20.0
              601.000                     601.000                        <30.0                 50.0               <-20.0
    28
             1202.000                    1202.000                        <30.0                 50.0               <-20.0
              649.000                     649.000                        <30.0                 50.0               <-20.0
    36
             1298.000                    1298.000                        <30.0                 50.0               <-20.0
              703.000                     703.000                        <30.0                 50.0               <-20.0
    45
             1406.000                    1406.000                        <30.0                 50.0               <-20.0
              751.000                     751.000                        <30.0                 50.0               <-20.0
    53
             1502.000                    1502.000                        <30.0                 50.0               <-20.0
              799.000                     799.000                        <30.0                 50.0               <-20.0
    61
             1598.000                    1598.000                        <30.0                 50.0               <-20.0
              847.000                     847.000                        <30.0                 50.0               <-20.0
    69
             1694.000                    1694.000                        <30.0                 50.0               <-20.0

Note: Negative signs (-) in the margin column signify levels below the limit.
    Limit (50 dBµV) was converted from the limit (2nW) at the 50Ω measurement impedance.




                                                 CTC Laboratories, Inc.
             1-2/F., Building 2, Jiaquan Building, Guanlan High-Tech Park, Shenzhen, Guangdong, China
                  Tel.: (86)755-27521059       Fax.: (86)755-27521011         Http://www.sz-ctc.org.cn
                                               For anti-fake verification, please visit the official website of Certification and
                                               Accreditation Administration of the People’s Republic of China : yz.cncaic.cn


                                                              Page 21 of 34                         Report No.: GTI20190096F



6    Antenna Power Conduction Measurement

    Test Mode: Mode 5
                Frequency                    Measured                       Reading                Limit              Margin
     Channel
                  (MHz)                   Frequency(MHz)                    (dBµV)                (dBµV)               (dB)
                 101.000                      101.000                        <30.0                 50.0               <-20.0
         2
                 202.000                      202.000                        <30.0                 50.0               <-20.0
                 107.000                      107.000                        <30.0                 50.0               <-20.0
         3
                 214.000                      214.000                        <30.0                 50.0               <-20.0
                 113.000                      113.000                        <30.0                 50.0               <-20.0
         4
                 226.000                      226.000                        <30.0                 50.0               <-20.0
                 123.000                      123.000                        <30.0                 50.0               <-20.0
         5
                 246.000                      246.000                        <30.0                 50.0               <-20.0
                 129.000                      129.000                        <30.0                 50.0               <-20.0
         6
                 258.000                      258.000                        <30.0                 50.0               <-20.0
                 221.000                      221.000                        <30.0                 50.0               <-20.0
         7
                 442.000                      442.000                        <30.0                 50.0               <-20.0
                 227.000                      227.000                        <30.0                 50.0               <-20.0
         8
                 454.000                      454.000                        <30.0                 50.0               <-20.0
                 233.000                      233.000                        <30.0                 50.0               <-20.0
         9
                 466.000                      466.000                        <30.0                 50.0               <-20.0
                 239.000                      239.000                        <30.0                 50.0               <-20.0
        10
                 478.000                      478.000                        <30.0                 50.0               <-20.0
                 245.000                      245.000                        <30.0                 50.0               <-20.0
        11
                 490.000                      490.000                        <30.0                 50.0               <-20.0
                 251.000                      251.000                        <30.0                 50.0               <-20.0
        12
                 502.000                      502.000                        <30.0                 50.0               <-20.0

    Note: Negative signs (-) in the margin column signify levels below the limit.
        Limit (50 dBµV) was converted from the limit (2nW) at the 50Ω measurement impedance.




                                                     CTC Laboratories, Inc.
                 1-2/F., Building 2, Jiaquan Building, Guanlan High-Tech Park, Shenzhen, Guangdong, China
                      Tel.: (86)755-27521059       Fax.: (86)755-27521011         Http://www.sz-ctc.org.cn
                                                   For anti-fake verification, please visit the official website of Certification and
                                                   Accreditation Administration of the People’s Republic of China : yz.cncaic.cn


                                                          Page 22 of 34                         Report No.: GTI20190096F



Test Mode: Mode 5
            Frequency                    Measured                       Reading                Limit              Margin
 Channel
               (MHz)                  Frequency(MHz)                    (dBµV)                (dBµV)               (dB)
              257.000                     257.000                        <30.0                 50.0               <-20.0
    13
              514.000                     514.000                        <30.0                 50.0               <-20.0
              517.000                     517.000                        <30.0                 50.0               <-20.0
    14
             1034.000                    1034.000                        <30.0                 50.0               <-20.0
              523.000                     523.000                        <30.0                 50.0               <-20.0
    15
             1046.000                    1046.000                        <30.0                 50.0               <-20.0
              553.000                     553.000                        <30.0                 50.0               <-20.0
    20
             1106.000                    1106.000                        <30.0                 50.0               <-20.0
              601.000                     601.000                        <30.0                 50.0               <-20.0
    28
             1202.000                    1202.000                        <30.0                 50.0               <-20.0
              649.000                     649.000                        <30.0                 50.0               <-20.0
    36
             1298.000                    1298.000                        <30.0                 50.0               <-20.0
              703.000                     703.000                        <30.0                 50.0               <-20.0
    45
             1406.000                    1406.000                        <30.0                 50.0               <-20.0
              751.000                     751.000                        <30.0                 50.0               <-20.0
    53
             1502.000                    1502.000                        <30.0                 50.0               <-20.0
              799.000                     799.000                        <30.0                 50.0               <-20.0
    61
             1598.000                    1598.000                        <30.0                 50.0               <-20.0
              847.000                     847.000                        <30.0                 50.0               <-20.0
    69
             1694.000                    1694.000                        <30.0                 50.0               <-20.0

Note: Negative signs (-) in the margin column signify levels below the limit.
    Limit (50 dBµV) was converted from the limit (2nW) at the 50Ω measurement impedance.




                                                 CTC Laboratories, Inc.
             1-2/F., Building 2, Jiaquan Building, Guanlan High-Tech Park, Shenzhen, Guangdong, China
                  Tel.: (86)755-27521059       Fax.: (86)755-27521011         Http://www.sz-ctc.org.cn
                                               For anti-fake verification, please visit the official website of Certification and
                                               Accreditation Administration of the People’s Republic of China : yz.cncaic.cn


                                                              Page 23 of 34                         Report No.: GTI20190096F



7    Picture Sensitivity Measurement

    Test Mode: Mode 4
             VHF Band                                                    UHF Band
                                           Antenna                                                                Antenna
                   Frequency                                                    Frequency
                                         Input Level                                                            Input Level
      Channel        Range                                         Channel        Range
                                           (dBµV)                                                                 (dBµV)
                     (MHz)                                                        (MHz)
           2         55.250                   23                     14          471.250                              26
           3         61.250                   25                     20          507.250                              27
           4         67.250                   27                     26          543.250                              26
           5         77.250                   28                     32          579.250                              28
           6         83.250                   24                     38          615.250                              25
           7        175.250                   27                     44          651.250                              25
           8        181.250                   25                     50          687.250                              28
           9        187.250                   26                     56          723.250                              27
          10        193.250                   22                     62          759.250                              25
          11        199.250                   27                     69          801.250                              24
          12        205.250                   28                      /             /                                  /
          13        211.250                   23                      /             /                                  /
            Average(VHF)                     25.42                      Average(UHF)                                 26.1
                           Average(UHF)-Average(VHF)= 0.68dB(Limit 8.0dB)




                                                     CTC Laboratories, Inc.
                 1-2/F., Building 2, Jiaquan Building, Guanlan High-Tech Park, Shenzhen, Guangdong, China
                      Tel.: (86)755-27521059       Fax.: (86)755-27521011         Http://www.sz-ctc.org.cn
                                                   For anti-fake verification, please visit the official website of Certification and
                                                   Accreditation Administration of the People’s Republic of China : yz.cncaic.cn


                                                             Page 24 of 34                         Report No.: GTI20190096F



8   Noise Figure Measurement

    Test Mode: Mode 4
                            Measured
                                                             Gain                  Noise Figure                    Limit
      Channel               Frequency
                                                             (dB)                      (dB)                        (dB)
                               (MHz)
         14                  471.250                        >30.0                         4.3                        14
         20                  507.250                        >30.0                         4.4                        14
         26                  543.250                        >30.0                         4.0                        14
         32                  579.250                        >30.0                         4.5                        14
         38                  615.250                        >30.0                         4.1                        14
         44                  651.250                        >30.0                         4.2                        14
         50                  687.250                        >30.0                         4.2                        14
         56                  723.250                        >30.0                         4.3                        14
         62                  759.250                        >30.0                         3.9                        14
         69                  801.250                        >30.0                         4.1                        14

    Remark: The specification was provided by tuner manufacturer.




                                                    CTC Laboratories, Inc.
                1-2/F., Building 2, Jiaquan Building, Guanlan High-Tech Park, Shenzhen, Guangdong, China
                     Tel.: (86)755-27521059       Fax.: (86)755-27521011         Http://www.sz-ctc.org.cn
                                                  For anti-fake verification, please visit the official website of Certification and
                                                  Accreditation Administration of the People’s Republic of China : yz.cncaic.cn


                                                         Page 25 of 34                         Report No.: GTI20190096F



9   EUT TEST PHOTO

                                    Conducted Measurement Photo




                            Radiated Measurement Photo 30~1000MHz




                                                CTC Laboratories, Inc.
            1-2/F., Building 2, Jiaquan Building, Guanlan High-Tech Park, Shenzhen, Guangdong, China
                 Tel.: (86)755-27521059       Fax.: (86)755-27521011         Http://www.sz-ctc.org.cn
                                              For anti-fake verification, please visit the official website of Certification and
                                              Accreditation Administration of the People’s Republic of China : yz.cncaic.cn


                                             Page 26 of 34                         Report No.: GTI20190096F



            Radiated Measurement Photo 1000~6000MHz




                                    CTC Laboratories, Inc.
1-2/F., Building 2, Jiaquan Building, Guanlan High-Tech Park, Shenzhen, Guangdong, China
     Tel.: (86)755-27521059       Fax.: (86)755-27521011         Http://www.sz-ctc.org.cn
                                  For anti-fake verification, please visit the official website of Certification and
                                  Accreditation Administration of the People’s Republic of China : yz.cncaic.cn


Ea                                                      Page 27 of 34                           Report No.: GTI20190096F




10 ATTACHMENT PHOTOGRAPHS OF EUT
           1.     Photo




           2.     Photo




                                                 CTC Laboratories, Inc.
                1—2/F., Building 2, Jiaquan Building, Guanlan High—Tech Park, Shenzhen, Guangdong, China
                    Tel.: (86)755—27521059     Fax.: (86)755—27521011        Hittp://www.sz—ctc.org.cn
EN         WEUTkEZEEz&AR                      For anti—fake verification, please visit the official website of Certification e}nd
CH   T«Eo«%%w t Tmmgwfie a>2 K                 Accreditation Administration of the People‘s Republic of China : yz.cncaic.cn


Ea                                                         Page 28 of 34                          Report No.: GTI20190096F




              3.     —Photo




              4.     Photo




                                                    CTC Laboratories, Inc.
                   1—2/F., Building 2, Jiaquan Building, Guanlan High—Tech Park, Shenzhen, Guangdong, China
                       Tel.: (86)755—27521059     Fax.: (86)755—27521011        Hittp://www.sz—ctc.org.cn
[=Mie   iss g%fiufiffigfiég§ mA P3                   For anti—fake verification, please visit the official website of Certification and
S       en «        P es                         Accreditation Administration of the People‘s Republic of China : yz.cncaic.ch


                                                  Page 29 of 34                         Report No.: GTI20190096F



5.     Photo




6.     Photo




                                         CTC Laboratories, Inc.
     1-2/F., Building 2, Jiaquan Building, Guanlan High-Tech Park, Shenzhen, Guangdong, China
          Tel.: (86)755-27521059       Fax.: (86)755-27521011         Http://www.sz-ctc.org.cn
                                       For anti-fake verification, please visit the official website of Certification and
                                       Accreditation Administration of the People’s Republic of China : yz.cncaic.cn


Ea                                                Page 30 of 34                           Report No.: GTI20190096F




     8.     Photo




                                           CTC Laboratories, Inc.
          1—2/F., Building 2, Jiaquan Building, Guanlan High—Tech Park, Shenzhen, Guangdong, China
                 :                      Fax.: (86)755—27521011         Hittp://www.sz—ctc.org.cn
                                        For anti—fake verification, please visit the official website of Certification and
                                        Accreditation Administration of the People‘s Republic of China : yz.cncaic.ch


                                                  Page 31 of 34                         Report No.: GTI20190096F



9.     Photo




10. Photo




                                         CTC Laboratories, Inc.
     1-2/F., Building 2, Jiaquan Building, Guanlan High-Tech Park, Shenzhen, Guangdong, China
          Tel.: (86)755-27521059       Fax.: (86)755-27521011         Http://www.sz-ctc.org.cn
                                       For anti-fake verification, please visit the official website of Certification and
                                       Accreditation Administration of the People’s Republic of China : yz.cncaic.cn


                                               Page 32 of 34                         Report No.: GTI20190096F



11. Photo




12. Photo




                                      CTC Laboratories, Inc.
  1-2/F., Building 2, Jiaquan Building, Guanlan High-Tech Park, Shenzhen, Guangdong, China
       Tel.: (86)755-27521059       Fax.: (86)755-27521011         Http://www.sz-ctc.org.cn
                                    For anti-fake verification, please visit the official website of Certification and
                                    Accreditation Administration of the People’s Republic of China : yz.cncaic.cn


                                               Page 33 of 34                         Report No.: GTI20190096F



13. Photo




14. Photo




                                      CTC Laboratories, Inc.
  1-2/F., Building 2, Jiaquan Building, Guanlan High-Tech Park, Shenzhen, Guangdong, China
       Tel.: (86)755-27521059       Fax.: (86)755-27521011         Http://www.sz-ctc.org.cn
                                    For anti-fake verification, please visit the official website of Certification and
                                    Accreditation Administration of the People’s Republic of China : yz.cncaic.cn


                                               Page 34 of 34                         Report No.: GTI20190096F



15. Photo




16. Photo




        ===== End of Test Report =====



                                      CTC Laboratories, Inc.
  1-2/F., Building 2, Jiaquan Building, Guanlan High-Tech Park, Shenzhen, Guangdong, China
       Tel.: (86)755-27521059       Fax.: (86)755-27521011         Http://www.sz-ctc.org.cn
                                    For anti-fake verification, please visit the official website of Certification and
                                    Accreditation Administration of the People’s Republic of China : yz.cncaic.cn



Document Created: 2019-03-25 16:21:32
Document Modified: 2019-03-25 16:21:32

© 2024 FCC.report