Test Report_Part II

FCC ID: 2AHU2MA110

Test Report

Download: PDF
FCCID_4270695

Dongguan Nore Testing Center Co., Ltd.
Report No.: NTC1904035FV00
FCC ID: 2AHU2MA110



                                 8DPSK Highest Channel




                                                         Page 50 of 56


Dongguan Nore Testing Center Co., Ltd.
Report No.: NTC1904035FV00
FCC ID: 2AHU2MA110



 11. Antenna Application

    11.1 Antenna requirement

         According to of FCC part 15C section 15.203 and 15.240:

         An intentional radiator shall be designed to ensure that no antenna other than that
         furnished by the responsible party shall be used with the device. The use of a
         permanently attached antenna or of an antenna that uses a unique coupling to the
         intentional radiator, the manufacturer may design the unit so that a broken antenna
         can be replaced by the user, but the use of a standard antenna jack or electrical
         connector is prohibited.
         Systems operating in the 2400-2483.5MHz band that are used exclusively for fixed,
         point-to-point operations may employ transmitting antennas with directional gain
         greater than 6dBi provided the maximum peak output power of the intentional
         radiator is reduced by 1dB for every 3dB that the directional gain of the antenna
         exceeds 6dBi.



    11.2 Measurement Results

         The antenna is PCB antenna and no consideration of replacement, and the best
         case gain of the antenna is 0 dBi. So, the antenna is consider meet the requirement.




                                                                                  Page 51 of 56


Dongguan Nore Testing Center Co., Ltd.
Report No.: NTC1904035FV00
FCC ID: 2AHU2MA110



 12. Conducted Spurious Emissions

    12.1 Measurement Procedure

         Out of Band Conducted Spurious Emissions, FCC Rule 15.247(d):

         The transmitter output is connected to spectrum analyzer. All spurious emission and
         up tp the tenth harmonic was measured and they were found to be at least 20dB
         below the highest level of the desired power in the passband.



    12.2. Measurement Results

          Please refer to following plots, the worst case (GFSK) was shown.




                                                                                 Page 52 of 56


Dongguan Nore Testing Center Co., Ltd.
Report No.: NTC1904035FV00
FCC ID: 2AHU2MA110



                                         Lowest Channel




                                                          Page 53 of 56


Dongguan Nore Testing Center Co., Ltd.
Report No.: NTC1904035FV00
FCC ID: 2AHU2MA110



                                         Middle Channel




                                                          Page 54 of 56


Dongguan Nore Testing Center Co., Ltd.
Report No.: NTC1904035FV00
FCC ID: 2AHU2MA110



                                         Highest Channel




                                  Note: Sweep points=30001pts




                                                                Page 55 of 56


  Dongguan Nore Testing Center Co., Ltd.
  Report No.: NTC1904035FV00
  FCC ID: 2AHU2MA110



    13. Test Equipment List

  Description       Manufacturer    Model Number      Serial    Characteristics    Calibration    Calibration
                                                     Number                          Date         Due Date
Test Receiver     Rohde & Schwarz      ESCI7          100837     9KHz~7GHz        Mar. 13, 2019 Mar. 12, 2020
   Antenna         Schwarzbeck       VULB9162        9162-010   30MHz~7GHz        Mar. 14, 2019 Mar. 13, 2020
    Cable          Huber+Suhner     CBL2-NN-1M      22390001     9KHz~7GHz        Mar. 13, 2019 Mar. 12, 2020
    Cable          Huber+Suhner        CIL02            N/A      9KHz~7GHz        Mar. 13, 2019 Mar. 12, 2020
  RF Cable         Huber+Suhner       SF-104        MY16559/4   9KHz~25GHz        Apr. 25, 2019 Apr. 25, 2020
Power Amplifier         HP           HP 8447D      1145A00203 100KHz~1.3GHz Mar. 13, 2019 Mar. 12, 2020
Horn Antenna       Schwarzbeck       BBHA9170        9170-242   15GHz~40GHz       Mar. 13, 2019 Mar. 12, 2020
Horn Antenna        Com-Power         AH-118          071078    1GHz~18GHz        Mar. 14, 2019 Mar. 13, 2020
  RF Cable         Huber+Suhner       SF-104            N/A     9KHz~40GHz        Apr. 25, 2019 Apr. 25, 2020
Loop antenna           Daze          ZA30900A          0708     9KHz~30MHz        Apr. 25, 2019 Apr. 25, 2020
  Spectrum
                  Rohde & Schwarz      FSU26       200409/026   20Hz~26.5GHz      Apr. 25, 2019 Apr. 25, 2020
  Analyzer
  Spectrum
                  Rohde & Schwarz      FSV40          101003    10Hz~40GHz        Apr. 06, 2019 Apr. 05, 2020
  Analyzer
 Pre-Amplifier         EMCI         EMC 184045        980102    18GHz~40GHz       Nov. 02, 2018 Nov. 01, 2019
 Pre-Amplifier        Agilent          8449B       3008A02964 1GHz~26.5GHz Apr. 25, 2019 Apr. 25, 2020
   L.I.S.N.       Rohde & Schwarz     ENV 216         101317    9KHz~30MHz        Mar. 13, 2019 Mar. 12, 2020
  Temporary
   antenna           TESCOM            SS402            N/A     9KHz-25GHz            N/A              N/A
  connector
 Power Meter          Anritsu         ML2495A        1139001     100k-65GHz       Nov. 02, 2018 Nov. 01, 2019
Power Sensor          Anritsu         MA2411B         100345    300M-40GHz        Nov. 02, 2018 Nov. 01, 2019



  Note: The temporary antenna connector is soldered on the PCB board in order to perform
  conducted tests and this temporary antenna coSnnector is listed in the equipment list.




                                                   ---End---
                                                                                             Page 56 of 56



Document Created: 2019-05-10 23:01:22
Document Modified: 2019-05-10 23:01:22

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC