RF exposure

FCC ID: 2AHST-RGBW

RF Exposure Info

Download: PDF
FCCID_4283451

SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                      FCC ID: 2AHST-RGBW                 Report No.: LCS190322042AEA


                                          FCC RF Exposure Evaluation

          1. Product Information

          FCC ID                                       2AHST-RGBW
          Product name                                 LED Controllers
          Test Model                                   SR-ZG9101FA-RGBW
                                                       SR-ZG9101FA-RGBW, SR-ZG9001K12-DIM-Z5,
                                                       SR-ZG9001T-RGBW-US, SR-ZG9001T3-RGBW-US,
                                                       SR-ZG9101FA-DIM, SR-ZG2819S-RGB, SR-ZG9001K12-DIM-Z3,
                                                       SR-ZG9001K12-DIM-Z4, SR-ZG9101SAC-HP,
          Model number
                                                       SR-ZG9101SAC-SWITCH, SR-ZG9101FA-DIM, SR-ZG9101FA-CCT,
                                                       SR-ZG9101EA-5C, SR-ZG2855-CCT, SR-ZG2855-5C, SR-ZV9080-B,
                                                       SR-ZV9040B, SR-ZV9101SAC-HP, SR-ZV9101SAC-SWITCH,
                                                       SR-ZV9001K2-DIM, SR-ZV9001K2-DIM2, SR-ZV9101FA-DIM-US
                                                       PCB board, structure and internal of these model(s) are the
          Model Declaration
                                                       same, So no additional models were tested.
                                                       Input: DC 12-36V
          Power supply
                                                       Output: DC 12-36V
          Modulation Type                              GFSK
          Antenna Type                                 Internal antenna
          Antenna Gain                                 0dBi (maximum)
          Hardware version                             V1.0
          Software version                             V1.0
          Operation frequency                          2405MHz-2480MHz
          Exposure category                            General population/uncontrolled environment
          EUT Type                                     Production Unit
          Device Type                                  Mobile Device



2. Evaluation Method

Systems operating under the provisions of FCC 47 CFR section shall be operated in a manner that ensures that
the public is not exposed to radio frequency energy level in excess of the Commission’s guidelines.
In accordance with 47 CFR FCC Part 2 Subpart J, section 2.1091 this device has been defined as mobile device
whereby a distance of 0.2m normally can be maintained between the user and the device, and below RF
Permissible Exposure limit shall comply with.

In accordance with KDB447498D01 for Simultaneous transmission MPE test exclusion applies when the sum of
the MPE ratios for all simultaneous transmitting antennas incorporated in a host device, based on the
calculated/estimated, numerically modelled or measured field strengths or power density, is ≤ 1.0. The MPE ratio
of each antenna is determined at the minimum test separation distance required by the operating configurations
and exposure conditions of the host device, according to the ratio of field strengths or power density to MPE limit,
at the test frequency. Either the maximum peak or spatially averaged results from measurements or numerical
simulations may be used to determine the MPE ratios. Spatial averaging does not apply when MPE is estimated
___________________________________________________________________________
      This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                     Page 1 of 4


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                      FCC ID: 2AHST-RGBW                 Report No.: LCS190322042AEA


using simple calculations based on far-field plane-wave equivalent conditions. The antenna installation and
operating requirements for the host device must meet the minimum test separation distances required by all
antennas, in both standalone and simultaneous transmission operations, to satisfy compliance.


3. Limit

3. 1 Refer evaluation method

ANSI C95.1–1999: IEEE Standard for Safety Levels with Respect to Human Exposure to Radio Frequency
Electromagnetic Fields, 3 kHz to 300 GHz.
FCC KDB publication 447498 D01 General 1 RF Exposure Guidance v06: Mobile and Portable Devices RF
Exposure Procedures and Equipment Authorization Policies.
FCC CFR 47 part1 1.1310: Radiofrequency radiation exposure limits.
FCC CFR 47 part2 2.1091: Radiofrequency radiation exposure evaluation: mobile devices

3. 2 Limit

                         Limits for Maximum Permissible Exposure (MPE)/Controlled Exposure
                Frequency             Electric Field         Magnetic Field          Power Density          Averaging Time
               Range(MHz)             Strength(V/m)          Strength(A/m)             (mW/cm²)                (minute)
                                          Limits for Occupational/Controlled Exposure
                0.3 – 3.0                   614                     1.63                  (100) *                     6
                3.0 – 30                   1842/f                  4.89/f                (900/f2)*                    6
                30 – 300                    61.4                   0.163                     1.0                      6
               300 – 1500                    /                        /                    f/300                      6
             1500 – 100,000                  /                        /                       5                       6
                        Limits for Maximum Permissible Exposure (MPE)/Uncontrolled Exposure
                Frequency             Electric Field         Magnetic Field          Power Density          Averaging Time
               Range(MHz)             Strength(V/m)          Strength(A/m)             (mW/cm²)                (minute)
                                          Limits for Occupational/Controlled Exposure
                0.3 – 3.0                    614                    1.63                  (100) *                    30
                3.0 – 30                    824/f                  2.19/f                (180/f2)*                   30
                30 – 300                    27.5                   0.073                    0.2                      30
               300 – 1500                     /                       /                   f/1500                     30
             1500 – 100,000                   /                       /                     1.0                      30

         F=frequency in MHz
         *=Plane-wave equivalent power density




___________________________________________________________________________
      This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                     Page 2 of 4


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                      FCC ID: 2AHST-RGBW                 Report No.: LCS190322042AEA


4. MPE Calculation Method

Predication of MPE limit at a given distance
Equation from page 18 of OET Bulletin 65, Edition 97-01

S=PG/4πR²

Where: S=power density
       P=power input to antenna
       G=power gain of the antenna in the direction of interest relative to an isotropic radiator
       R=distance to the center of radiation of the antenna



5. Antenna Information

    LED Controllers can only use antennas certificated as follows provided by manufacturer;


          Internal              Antenna type and
                                                               Operate frequency band                  Maximum antenna gain
        Identification          antenna number
         Antenna 0               Internal Antenna               2405 MHz – 2480 MHz                                0 dBi


6. Conducted Power

                                                                   Frequency                Measured Peak Output Power
                 Test Mode                    Channel
                                                                     (MHz)                            (dBm)
                                                   0                   2405                                -2.909
                    FSK                            9                   2450                                -3.059
                                                  15                   2480                                -0.436


7. Manufacturing Tolerance


                                                               FSK (Peak)
                     Channel                    Channel 0                     Channel 9                     Channel 15
                  Target (dBm)                      -2.5                          -2.5                            0
                Tolerance ±(dB)                     1.0                           1.0                            1.0


8. Measurement Results

8.1 Standalone MPE

As declared by the Applicant, the EUT is a wireless device used in a fix application, at least 20 cm from any body
part of the user or nearby persons; from the maximum EUT RF output power, the minimum separation distance, r
=20cm, as well as the gain of the used antenna refer to antenna information, the RF power density can be
obtained.

___________________________________________________________________________
      This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                     Page 3 of 4


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                      FCC ID: 2AHST-RGBW                 Report No.: LCS190322042AEA



Antenna 0


                                     Output power                 Antenna          Antenna                                          MPE
                                                                                                    Duty           MPE
   Modulation Type                                                 Gain              Gain                                           Limits
                                  dBm                mW                                             Cycle        (mW/cm2)
                                                                   (dBi)           (linear)                                       (mW/cm2)
         FSK                       1.0             1.2589              0              1.0           100%           0.0003           1.0000


Remark:
1. Output power (Peak) including tune-up tolerance;
2. MPE evaluate distance is 20cm from user manual provide by manufacturer;



8.2 Simultaneous Transmission MPE

The sample only support one Zigbee modular and one antenna, no need consider simultaneous transmission;



9. Conclusion

The measurement results comply with the FCC Limit per 47 CFR 2.1091 for the uncontrolled RF Exposure of
mobile device.




                              .......................THE END OF REPORT.........................




___________________________________________________________________________
      This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                     Page 4 of 4



Document Created: 2019-05-16 07:26:47
Document Modified: 2019-05-16 07:26:47

© 2024 FCC.report