RF Exposure Report

FCC ID: 2AHRH-FJ500M

RF Exposure Info

Download: PDF
FCCID_4306613

          RF Exposure Evaluation Report                                          Report No. : FA941809




                   RF Exposure Evaluation Report

                APPLICANT              : Positioning Universal

                EQUIPMENT              : asset tracking device

                BRAND NAME             : FJ500M

                MODEL NAME             : FJ500M

                FCC ID                 : Contains FCC ID :2AHRH-FJ500M

                STANDARD               : 47 CFR Part 2.1091
                                         FCC KDB 447498 D01 v06

      The product was installed a module during the test: M2M DATA MODULE (Model Name:
      IMA2A, FCC ID: 2AHRH-FJ500M) during test.

      We, Sporton International (Kunshan) Inc., would like to declare that the device has been
      evaluated in accordance with 47 CFR Part 2.1091 and FCC KDB 447498 D01 v06, and pass
      the limit. Without written approval of Sporton International (Kunshan) Inc., the test report
      shall not be reproduced except in full.




        Reviewed by: Rose Wang / Supervisor




            Approved by: Kat Yin / Manager


                               Sporton International (Kunshan) Inc.
No. 1098, Pengxi North Road, Kunshan Economic Development Zone Jiangsu Province 215300
                                People’s Republic of China


Sporton International (Kunshan) Inc.                                   Page Number        : 1 of 8
TEL : +86-512-57900158                                                 Report Issued Date : May 30, 2019
FAX : +86-512-57900958                                                 Report Version     : Rev. 01
FCC ID : 2AHRH-FJ500M


            RF Exposure Evaluation Report                                                                                   Report No. : FA941809

                                                        Table of Contents
1. ADMINISTRATION DATA ........................................................................................................................... 4
     1.1.     Testing Laboratory ............................................................................................................................. 4
2. DESCRIPTION OF EQUIPMENT UNDER TEST (EUT) ............................................................................. 5
3. MAXIMUM RF AVERAGE OUTPUT POWER AMONG PRODUCTION UNITS ........................................ 6
4. RF EXPOSURE LIMIT INTRODUCTION .................................................................................................... 7
5. RADIO FREQUENCY RADIATION EXPOSURE EVALUATION ............................................................... 8
     5.1.     Standalone Power Density Calculation ............................................................................................. 8




Sporton International (Kunshan) Inc.                                                                          Page Number        : 2 of 8
TEL : +86-512-57900158                                                                                        Report Issued Date : May 30, 2019
FAX : +86-512-57900958                                                                                        Report Version     : Rev. 01
FCC ID : 2AHRH-FJ500M


          RF Exposure Evaluation Report                                             Report No. : FA941809
                                                 Revision History
   REPORT NO.           VERSION                             DESCRIPTION                    ISSUED DATE

     FA941809            Rev. 01       Initial issue of report                              May 30, 2019




Sporton International (Kunshan) Inc.                                      Page Number        : 3 of 8
TEL : +86-512-57900158                                                    Report Issued Date : May 30, 2019
FAX : +86-512-57900958                                                    Report Version     : Rev. 01
FCC ID : 2AHRH-FJ500M


          RF Exposure Evaluation Report                                               Report No. : FA941809
1. Administration Data

1.1. Testing Laboratory
Sporton International (Kunshan) Inc. is accredited to ISO/IEC 17025:2017 by American Association for
Laboratory Accreditation with Certificate Number 5145.02.

                                                Testing Laboratory

Test Firm                    Sporton International (Kunshan) Inc.

                             No. 1098, Pengxi North Road, Kunshan Economic Development Zone

                             Jiangsu Province 215300 People’s Republic of China
Test Site Location
                             TEL : +86-512-57900158
                             FAX : +86-512-57900958

                                       FCC Designation No.             FCC Test Firm Registration No.
Test Site No.
                                            CN1257                                  314309


                                                     Applicant
Company Name                     Positioning Universal
Address                          4660 La Jolla Village Dr Suite #1100, San Diego, CA92122




Sporton International (Kunshan) Inc.                                        Page Number        : 4 of 8
TEL : +86-512-57900158                                                      Report Issued Date : May 30, 2019
FAX : +86-512-57900958                                                      Report Version     : Rev. 01
FCC ID : 2AHRH-FJ500M


          RF Exposure Evaluation Report                                                    Report No. : FA941809
2. Description of Equipment Under Test (EUT)
                                           Product Feature & Specification
EUT Type                     asset tracking device
Brand Name                   FJ500M
Model Name                   FJ500M
FCC ID                       Contains FCC ID : 2AHRH-FJ500M
S/N                     JKP3A191000028
                        LTE Band 2: 1850 MHz ~ 1910 MHz
Wireless Technology and
                        LTE Band 4: 1710 MHz ~ 1755 MHz
Frequency Range
                        LTE Band 12: 699 MHz ~ 716 MHz
Mode                    LTE Category M1: QPSK/16QAM
HW Version                   v1.0
SW Version                   6300
EUT Stage                     Production Unit
Remark: The above EUT's information was declared by manufacturer. Please refer to the specifications or user's manual
for more detailed description.


                                           Module Feature & Specification
Equipment Name               M2M DATA MODULE
Model Name                   IMA2A
FCC ID                       2AHRH-FJ500M




Sporton International (Kunshan) Inc.                                             Page Number        : 5 of 8
TEL : +86-512-57900158                                                           Report Issued Date : May 30, 2019
FAX : +86-512-57900958                                                           Report Version     : Rev. 01
FCC ID : 2AHRH-FJ500M


          RF Exposure Evaluation Report                             Report No. : FA941809
3. Maximum RF average output power among production units

<LTE >


                            Mode                 Maximum Average power(dBm)

                                       Band 2               25.00
             LTE                       Band 4               25.00
                                       Band 12              25.00




Sporton International (Kunshan) Inc.                    Page Number        : 6 of 8
TEL : +86-512-57900158                                  Report Issued Date : May 30, 2019
FAX : +86-512-57900958                                  Report Version     : Rev. 01
FCC ID : 2AHRH-FJ500M


          RF Exposure Evaluation Report                                                     Report No. : FA941809
4. RF Exposure Limit Introduction
According to ANSI/IEEE C95.1-1992, the criteria listed in Table 1 shall be used to evaluate the environmental impact of

human exposure to radio frequency (RF) radiation as specified in §1.1310.




     The MPE was calculated at 20 cm to show compliance with the power density limit.
     The following formula was used to calculate the Power Density:


                                                           𝐏𝐆
                                                    𝐒=
                                                          𝟒𝛑𝐑𝟐
     Where:
     S = Power Density
     P = Output Power at Antenna Terminals
     G = Gain of Transmit Antenna (linear gain)
     R = Distance from Transmitting Antenna




Sporton International (Kunshan) Inc.                                              Page Number        : 7 of 8
TEL : +86-512-57900158                                                            Report Issued Date : May 30, 2019
FAX : +86-512-57900958                                                            Report Version     : Rev. 01
FCC ID : 2AHRH-FJ500M


          RF Exposure Evaluation Report                                                       Report No. : FA941809
5. Radio Frequency Radiation Exposure Evaluation

5.1. Standalone Power Density Calculation
                                                                                                    Power
                                            Antenna   Maximum   Maximum   Maximum
                                Frequency                                              Average     Density at   Limit
             Band                            Gain      Power      EIRP     EIRP
                                  (MHz)                                               EIRP (mW)     20cm      (mW/cm^2)
                                             (dBi)     (dBm)     (dBm)      (W)
                                                                                                  (mW/cm^2)
          LTE Band 2              1850.7     1.34      25.00     26.340     0.431       430.527     0.086        1.000
          LTE Band 4              1710.7     0.47      25.00     25.470     0.352       352.371     0.070        1.000
         LTE Band 12              699.7      0.63      25.00     25.630     0.366       365.595     0.073        0.466
Note: For conservativeness, the lowest frequency of each band is used to determine the MPE limit of that band.




Conclusion:

According to 47 CFR §2.1091, the RF exposure analysis concludes that the RF Exposure is FCC compliant.




Sporton International (Kunshan) Inc.                                                Page Number        : 8 of 8
TEL : +86-512-57900158                                                              Report Issued Date : May 30, 2019
FAX : +86-512-57900958                                                              Report Version     : Rev. 01
FCC ID : 2AHRH-FJ500M



Document Created: 2019-06-07 06:30:34
Document Modified: 2019-06-07 06:30:34

© 2025 FCC.report
This site is not affiliated with or endorsed by the FCC