Test Report

FCC ID: 2AHN6-OPCP200

Test Report

Download: PDF
FCCID_4107022

d
|ACCREDITED|
                                                                                                             Bay Area Compliance               Labs Corp.
TESTING LABORATORY
CERTIFICATE # 4821.01



                                                          FCC PART 15C

                                                           TEST REPORT
                                                                           For


                                                           Bytech NY Inc.
                             2585 West 13th Street,Brooklyn NY 11223, New York, United States



                                                  FCC ID: 2AHN6—OPCP200



                        Report Type:                                        Product Type:

                        Original Report                                     SW Adjust Wireless Charge Stand




                             Report Number:            RSZ181029830—00


                                  Report Date:          2018—11—19

                                                        Rocky Kang                               &1) y h\a_ k N‘Q/

                                 Reviewed By:           RF Engineer

                             Test Laboratory:           Bay Area Compliance Laboratories Corp. (Shenzhen)
                                                        6/F., West Wing, Third Phase of Wanli Industrial
                                                        Building, Shihua Road, Futian Free Trade Zone,
                                                        Shenzhen, Guangdong, China
                                                        Tel: +86—755—33320018
                                                        Fax: +86—755—33320008
                                                        www.baclcorp.com.cn




          Note: This report must not be used bythe customer to claim product certification, approval, or endorsement by A2LA* or any agencyof
          the Federal Governmerc. * This report may contain data that are not covered by the A2LA accreditation and are marked with an asteriskc
          «en


Bay Area Compliance Laboratories Corp. (Shenzhen)                                                                          Report No.: RSZ181029830-00




                                                       TABLE OF CONTENTS

GENERAL INFORMATION .......................................................................................................................................3
 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) ....................................................................................3
 OBJECTIVE ...................................................................................................................................................................3
 RELATED SUBMITTAL(S)/GRANT(S) .............................................................................................................................3
 TEST METHODOLOGY ..................................................................................................................................................3
 MEASUREMENT UNCERTAINTY ....................................................................................................................................3
 TEST FACILITY .............................................................................................................................................................4
SYSTEM TEST CONFIGURATION ..........................................................................................................................5
  JUSTIFICATION .............................................................................................................................................................5
  EUT EXERCISE SOFTWARE ..........................................................................................................................................5
  SUPPORT EQUIPMENT LIST AND DETAILS ....................................................................................................................5
  EXTERNAL I/O CABLE..................................................................................................................................................5
  BLOCK DIAGRAM OF TEST SETUP ................................................................................................................................6
SUMMARY OF TEST RESULTS ...............................................................................................................................7
FCC §1.1310, §2.1091- MAXIMUM PERMISSIBLE EXPOSURE (MPE) .............................................................8
  APPLICABLE STANDARD ..............................................................................................................................................8
  BLOCK DIAGRAM OF TEST SETUP ................................................................................................................................9
  TEST EQUIPMENT LIST AND DETAILS ...........................................................................................................................9
  TEST DATA ..................................................................................................................................................................9
FCC§15.203 - ANTENNA REQUIREMENT............................................................................................................11
  APPLICABLE STANDARD ............................................................................................................................................11
  ANTENNA CONNECTED CONSTRUCTION ....................................................................................................................11
FCC §15.207 – AC LINE CONDUCTED EMISSION .............................................................................................12
  APPLICABLE STANDARD ............................................................................................................................................12
  EUT SETUP ................................................................................................................................................................12
  EMI TEST RECEIVER SETUP .......................................................................................................................................12
  TEST EQUIPMENT LIST AND DETAILS .........................................................................................................................13
  TEST PROCEDURE ......................................................................................................................................................13
  CORRECTED FACTOR & MARGIN CALCULATION .......................................................................................................14
  TEST RESULTS SUMMARY ..........................................................................................................................................14
  TEST DATA ................................................................................................................................................................14
FCC §15.205 & §15.209 - RADIATED EMISSIONS TEST ....................................................................................17
  APPLICABLE STANDARD ............................................................................................................................................17
  EUT SETUP ................................................................................................................................................................17
  EMI TEST RECEIVER SETUP .......................................................................................................................................18
  CORRECTED AMPLITUDE & MARGIN CALCULATION .................................................................................................18
  TEST EQUIPMENT LIST AND DETAILS .........................................................................................................................18
  TEST RESULTS SUMMARY ..........................................................................................................................................19
  TEST DATA ................................................................................................................................................................19




FCC Part 15C                                                                                                                                              Page 2 of 21


Bay Area Compliance Laboratories Corp. (Shenzhen)                              Report No.: RSZ181029830-00

GENERAL INFORMATION
Product Description for Equipment Under Test (EUT)
The Bytech NY Inc.’s product, model number: BY-OP-CP-200-BK (FCC ID: 2AHN6-OPCP200,
UPC Number: 805112045204, SKU Number: 3113917) in this report is a 5W Adjust Wireless Charge
Stand, which was measured approximately: 7.9 cm (L) * 7.9 cm (W) * 11.3 cm (H), rated with input
voltage: DC 5V.

* All measurement and test data in this report was gathered from production sample serial number: 181029830
(Assigned by BACL, Shenzhen). The EUT supplied by the applicant was received on 2018-10-29.


Objective
This report is prepared on behalf of Bytech NY Inc. in accordance with Part 2, Subpart J, and Part 15,
Subparts A and C of the Federal Communications Commission’s rules.

The objective is to determine the compliance of EUT with FCC rules, section 15.203, 15.205, 15.207 and
15.209.


Related Submittal(s)/Grant(s)
No related submittal(s).


Test Methodology
All measurements contained in this report were conducted with ANSI C63.10-2013, American National
Standard of Procedures for Compliance Testing of Unlicensed Wireless Devices.

All emissions measurement was performed at Bay Area Compliance Laboratories Corp. (Shenzhen). The
radiated testing was performed at an antenna-to-EUT distance of 3 meters.


Measurement Uncertainty


                                      Item                                         Uncertainty
                     AC Power Line Conducted Emissions                               ±1.95 dB
                                                 9 kHz~30MHz                         ±4.52 dB
               Radiated emission
                                                 30MHz~1 GHz                         ±5.81 dB
                            Occupied Bandwidth                                       ±0.5 kHz
                                   Temperature                                       ±3.0 ℃
                                    Humidity                                          ±6 ℅




FCC Part 15C                                                                                       Page 3 of 21


Bay Area Compliance Laboratories Corp. (Shenzhen)                        Report No.: RSZ181029830-00

Test Facility
The Test site used by Bay Area Compliance Laboratories Corp. (Shenzhen) to collect test data is located
on the 6/F., West Wing, Third Phase of Wanli Industrial Building, Shihua Road, Futian Free Trade Zone,
Shenzhen, Guangdong, China.

The test site has been approved by the FCC under the KDB 974614 D01 and is listed in the FCC Public
Access Link (PAL) database, FCC Registration No.: 342867, the FCC Designation No. : CN1221.

The test site has been registered with ISED Canada under ISED Canada Registration Number 3062B.




FCC Part 15C                                                                                Page 4 of 21


Bay Area Compliance Laboratories Corp. (Shenzhen)                        Report No.: RSZ181029830-00


SYSTEM TEST CONFIGURATION
Justification

The system was configured for testing in a test mode

The device is a wireless charger operation on frequency 110 kHz - 205 kHz.


EUT Exercise Software

No software used in test.


Support Equipment List and Details


       Manufacturer            Description             Model                  Serial Number

               /                   Load                  /                          /
         SENWA                   Adapter            SENWAC1A                        /


External I/O Cable

                   Cable Description                Length (m)       From Port                To

          Shielded detachable USB cable                 0.3             EUT              Adapter




FCC Part 15C                                                                                  Page 5 of 21


Bay Area Compliance Laboratories Corp. (Shenzhen)                  Report No.: RSZ181029830-00

Block Diagram of Test Setup
For Conducted Emissions:


                                                                                                LISN

                                                          Load   10cm
                                                                           Socket
                                                          EUT
                                                                 Adapter




                                                                                    1.0 meter
            Non-Conductive Table
            80 cm above Ground Plane

                                             1.5 meters




FCC Part 15C                                                                                    Page 6 of 21


Bay Area Compliance Laboratories Corp. (Shenzhen)                         Report No.: RSZ181029830-00

SUMMARY OF TEST RESULTS

               FCC Rules                       Description of Test                  Result
            FCC§1.1310 &
                                      Maximum Permissible Exposure(MPE)           Compliance
              §2.1091
               FCC§15.203                     Antenna Requirement                 Compliance
               FCC§15.207                 AC Line Conducted Emission              Compliance
            §15.209 §15.205                  Radiated Emission Test               Compliance




FCC Part 15C                                                                                 Page 7 of 21


Bay Area Compliance Laboratories Corp. (Shenzhen)                          Report No.: RSZ181029830-00

FCC §1.1310, §2.1091- MAXIMUM PERMISSIBLE EXPOSURE (MPE)
Applicable Standard
According to subpart §1.1310, systems operating under the provisions of this section shall be operated in a
manner that ensures that the public is not exposed to radio frequency energy level in excess of the
Commission’s guidelines.

Limits for Maximum Permissible Exposure (MPE) (§1.1310, §2.1091)

                         (B) Limits for General Population/Uncontrolled Exposure
Frequency Range        Electric Field       Magnetic Field        Power Density          Averaging Time
     (MHz)            Strength (V/m)        Strength (A/m)           (mW/cm2)              (minutes)
    0.3–1.34                614                     1.63               *(100)                   30
     1.34–30               824/f                    2.19/f            *(180/f²)                 30
     30–300                 27.5                    0.073                0.2                    30
    300–1500                 /                        /                 f/1500                  30
  1500–100,000               /                        /                  1.0                    30

f = frequency in MHz; * = Plane-wave equivalent power density;

According with KDB 680106 D01 RF Exposure Wireless Charging Apps v03 clause 3 c)




According to 680106 D01 RF Exposure Wireless Charging App v03 clause 5 b)




FCC Part 15C                                                                                  Page 8 of 21


Bay Area Compliance Laboratories Corp. (Shenzhen)                               Report No.: RSZ181029830-00

Block Diagram of Test Setup




                                                   15cm




Note: 20 cm for Top test.


Test Equipment List and Details

                                                                      Serial        Calibration    Calibration
     Manufacturer            Description            Model
                                                                     Number            Date         Due Date
         Narda          Exposure Level Tester       ELT-400           N-0215        2018-02-22     2019-02-21
                                                   ELT Probe
         Narda               B Field Probe                           M-0658         2018-02-22     2019-02-21
                                                     100cm2
     ETS-Lindgren           Isotropic Probe         HI-6005         00069461        2016-02-29     2019-02-28

    * Statement of Traceability: Bay Area Compliance Laboratories Corp. (Shenzhen) attests that all calibrations
     have been performed, traceable to National Primary Standards and International System of Units (SI).


Test Data
     Environmental Conditions

             Temperature:                  26C
        Relative Humidity:                 57 %
            ATM Pressure:              100.4 kPa

     The testing was performed by Hill He on 2018-11-13.

      Test mode: Transmitting




FCC Part 15C                                                                                        Page 9 of 21


Bay Area Compliance Laboratories Corp. (Shenzhen)                                   Report No.: RSZ181029830-00

H-Filed Strength
Frequency      Position    Position     Position      Position     Position       50%       Limit
  Range           A           B            C             D            E          Limit       Test
  (kHz)         (A/m)       (A/m)        (A/m)         (A/m)        (A/m)        (A/m)      (A/m)

 110-205        0.106        0.169        0.078        0.124         0.047        0.815      1.63


Note: Test with 15cm distance from the center of the probe(s) to the edge of the device, 20 cm for top test.

E-Filed Strength
Frequency      Position     Position     Position     Position      Position      50%        Limit
  Range           A            B            C            D             E         Limit        Test
  (kHz)         (V/m)        (V/m)        (V/m)        (V/m)         (V/m)       (V/m)       (V/m)

 110-205         1.16        1.35         1.37          1.27          1.31         307        614


Note: Test with 15cm distance from the center of the probe(s) to the edge of the device, 20 cm for top test.

Result: Compliance

Considerations of compliance 680106 D01 RF Exposure Wireless Charging App v03 clause 5 b:

(1) Power transfer frequency is less than 1 MHz.

Yes, the operation frequency is 110-205 kHz.

(2) Output power from each primary coil is less than or equal to 15 watts.

Yes, the maximum output power of primary coil is 5Watts, less than 15 watts.

(3) The transfer system includes only single primary and secondary coils. This includes charging systems
that may have multiple primary coils and clients that are able to detect and allow coupling only between
individual pairs of coils.

The transfer system includes only single primary coils to detect and allow coupling only between
individual pairs of coils.

(4) Client device is placed directly in contact with the transmitter.
Yes, client device is placed directly in contact with the transmitter

(5) Mobile exposure conditions only (portable exposure conditions are not covered by this exclusion).

Yes, mobile exposure conditions only

 (6) The aggregate H-field strengths at 15 cm surrounding the device and 20 cm above the top surface from
all simultaneous transmitting coils are demonstrated to be less than 50% of the MPE limit.

Yes, the test result for H and E-filed strength less than 50% of the MPE limit.




FCC Part 15C                                                                                             Page 10 of 21


Bay Area Compliance Laboratories Corp. (Shenzhen)                           Report No.: RSZ181029830-00

FCC§15.203 - ANTENNA REQUIREMENT
Applicable Standard
An intentional radiator shall be designed to ensure that no antenna other than that furnished by the
responsible party shall be used with the device. The use of a permanently attached antenna or of an
antenna that uses a unique coupling to the intentional radiator shall be considered sufficient to comply with
the provisions of this section.


Antenna Connected Construction
The EUT has a coil antenna arrangement, which was permanently attached, fulfill the requirement of this
section. Please refer to the EUT photos.

Result: Compliance.




FCC Part 15C                                                                                    Page 11 of 21


Bay Area Compliance Laboratories Corp. (Shenzhen)                           Report No.: RSZ181029830—00


FCC §15.207 — AC LINE CONDUCTED EMISSION

Applicable Standard

FCC§15.207


EUT Setup

                             ... Vertical Reference
                                     Ground Plane                            Test Receiver
                 * 10 em —                                               /
                                     EUT                                li_|e e# 0
                                                                            o pe o
                                 U
                                                        80cm


                                 uiss       P
                     >\                          1                     1
                                                                N
                             ~
                                     Eonded to Horizontal      Horizontal Reference
                                     Ground Plane              Ground Plane
                    Noto: 1. Supp ort units wore connocted to socond LISN.
                          2. Both of LISNs (AMN) 80 cm from EUT and at the least 80 cm
                             from other units and other metal planes support units.

The setup of EUT is according with per ANSI C63.10—2013 measurement procedure. The specification
used was with the FCC Part 15.207 limits.

The spacing between the peripherals was 10 cm.


EMI Test Receiver Setup

The EMI test receiver was set to investigate the spectrum from 150 kHz to 30 MHz.

During the conducted emission test, the EMI test receiver was set with thefollowing configurations:

                                     Frequency Range                IF BW

                                     150 kHz — 30 MHz               9 kHz




FCC Part 15C                                                                                  Page 12 of 21


Bay Area Compliance Laboratories Corp. (Shenzhen)                                 Report No.: RSZ181029830-00

Test Equipment List and Details

                                                                      Serial        Calibration    Calibration
      Manufacturer              Description           Model
                                                                     Number            Date         Due Date
     Rohde & Schwarz         EMI Test Receiver       ESCS30           100176         2018-07-11    2019-07-11
                                                                  3560.6650.12-
     Rohde & Schwarz               LISN              ENV216                          2017-12-21    2018-12-21
                                                                   101613-Yb
     Rohde & Schwarz         Transient Limiter       ESH3Z2          DE25985         2018-05-12    2018-11-21
     Rohde & Schwarz         CE Test software        EMC 32          V8.53.0           NCR            NCR
                            Conducted Emission                    UF A210B-1-
         Unknown                                      78652                          2018-05-12    2018-11-12
                                  Cable                           0720-504504

* Statement of Traceability: Bay Area Compliance Laboratories Corp. (Shenzhen) attests that all calibrations have
been performed, traceable to National Primary Standards and International System of Units (SI).


Test Procedure
During the conducted emission test, the adapter was connected to the outlet of the LISN.

Maximizing procedure was performed on the six (6) highest emissions of the EUT.

All final data was recorded in the Quasi-peak and average detection mode.




FCC Part 15C                                                                                         Page 13 of 21


Bay Area Compliance Laboratories Corp. (Shenzhen)                               Report No.: RSZ181029830-00

Corrected Factor & Margin Calculation
The Corrected factor is calculated by adding LISN VDF (Voltage Division Factor), Cable Loss and
Transient Limiter Attenuation. The basic equation is as follows:

      Correction Factor = LISN VDF + Cable Loss + Transient Limiter Attenuation

The “Margin” column of the following data tables indicates the degree of compliance with the applicable
limit. For example, a margin of 7 dB means the emission is 7 dB below the limit. The equation for margin
calculation is as follows:

      Margin = Limit – Corrected Amplitude


Test Results Summary
According to the recorded data in following table, the EUT complied with the FCC Part 15.207,


Refer to CISPR16-4-2:2011 and CISPR 16-4-1:2009, the measured level complies with the limit if

                                            Lm + U(Lm) ≤ Llim + Ucispr

In BACL, U(Lm) is less than Ucispr, if Lm is less than Llim, it implies that the EUT complies with the limit.


Test Data
     Environmental Conditions

                Temperature:           26C
          Relative Humidity:           57 %
               ATM Pressure:         100.4 kPa

      The testing was performed by Haiguo Li on 2018-11-09.




FCC Part 15C                                                                                        Page 14 of 21


Bay Area Compliance Laboratories Corp. (Shenzhen)                                Report No.: RSZ181029830-00

Test Mode: Transmitting

     AC 120 V/60 Hz, Line:


                         90


                         80


                         70

                                                                                                   QP
                         60
          Level in dBμ




                                                                                                     AV
                         50


                         40


                         30


                         20


                         10


                         0
                         150k   300 400 500   800 1M        2M     3M 4M 5M 6     8 10M      20M     30M
                                                        Frequency in Hz



                                Corrected     Correction
         Frequency                                                Limit     Margin          Detector
                                Amplitude      Factor
           (MHz)                                                 (dBμV)      (dB)         (PK/Ave./QP)
                                 (dBμV)         (dB)
           0.325110               40.1           19.8             59.6          19.5          QP
           0.348690               39.5           19.7             59.0          19.5          QP
           4.707830               38.4           20.1             56.0          17.6          QP
         18.856850                42.0           20.2             60.0          18            QP
         19.135110                42.5           20.2             60.0          17.5          QP
         19.420330                41.5           20.2             60.0          18.5          QP
           0.325110               33.0           19.8             49.6          16.6          Ave.
           0.348690               35.1           19.7             49.0          13.9          Ave.
           4.707830               32.5           20.1             46.0          13.5          Ave.
         18.856850                35.0           20.2             50.0          15            Ave.
         19.135110                29.1           20.2             50.0          20.9          Ave.
         19.420330                36.4           20.2             50.0          13.6          Ave.




FCC Part 15C                                                                                         Page 15 of 21


Bay Area Compliance Laboratories Corp. (Shenzhen)                                Report No.: RSZ181029830-00


     AC 120V/ 60 Hz, Neutral:



                         90


                         80


                         70

                                                                                                   QP
                         60
          Level in dBμ




                                                                                                     AV
                         50


                         40


                         30


                         20


                         10


                         0
                         150k   300 400 500   800 1M        2M     3M 4M 5M 6     8 10M      20M     30M
                                                        Frequency in Hz



                                Corrected     Correction
         Frequency                                                Limit     Margin          Detector
                                Amplitude      Factor
           (MHz)                                                 (dBμV)      (dB)         (PK/Ave./QP)
                                 (dBμV)         (dB)
           0.297470               40.3           19.8             60.3          20.0          QP
           0.340930               41.6           19.7             59.2          17.6          QP
         17.511170                39.9           20.2             60.0          20.1          QP
         19.114970                39.0           20.2             60.0          21.0          QP
         20.210070                40.4           20.2             60.0          19.6          QP
         22.199830                38.3           20.3             60.0          21.7          QP
           0.297470               34.3           19.8             50.3          16.0          Ave.
           0.340930               34.1           19.7             49.2          15.1          Ave.
         17.511170                34.2           20.2             50.0          15.8          Ave.
         19.114970                27.6           20.2             50.0          22.4          Ave.
         20.210070                33.7           20.2             50.0          16.3          Ave.
         22.199830                20.3           20.3             50.0          29.7          Ave.

     Note:
     1) Correction Factor =LISN VDF (Voltage Division Factor) + Cable Loss + Transient Limiter Attenuation
     2) Corrected Amplitude = Reading + Correction Factor
     3) Margin = Limit – Corrected Amplitude
FCC Part 15C                                                                                         Page 16 of 21


Bay Area Compliance Laboratories Corp. (Shenzhen)                                 Report No.: RSZ181029830—00


FCC §15.205 & §15.209 — RADIATED EMISSIONS TEST

Applicable Standard
As per FCC Part 15.209

 (a) Except as provided elsewhere in this subpart, the emissions from an intentional radiator shall not
exceed the field strength levels specified in the following table:

  Frequency (MHz)              Field strength (microvolts/meter)             Measurement distance (meters)
0.009—0.490              2400/F(kHz)                                                                            300]
0.490—1.705              [24000/F(kHz)                                                                               30
1.705—30.0               B0                                                                                          30
30—88                    100**                                                                                        3
ss—216                   150**                                                                                        3
216—960                  200**                                                                                        3
|Above 960               500                                                                                          3
      **Except as provided in paragraph (2), fundamental emissions from intentional radiators operating under this
section shall not be located in the frequency bands 54—72 MHz, 76—88 MHz, 174—216 MHz or 470—806 MHz.
However, operation within these frequency bands is permltted underother sections of this part, e.g., §§15.231 and
15.241.



EUT Setup

                                                                  Ant. Tow             Li4m
                                                                             \    Nariable
                   EUT&               p>—____G@m                                 /
                   Support Units
                                             Tarn Table
                       o.SmI

                                                 Ground Plane
                                                  Test Receiver

                                                                   *l MrZI o o a o
                                                                             a o a e

The radiated emission tests were performed in the 3—meter chamber test site, using the setup accordance
with the ANSI C63.10—2013. The specification used was the FCC Part Subpart C limits.

The spacing between the peripherals was 10 cm.




FCC Part 15C                                                                                          Page 17 of 21


Bay Area Compliance Laboratories Corp. (Shenzhen)                               Report No.: RSZ181029830-00


EMI Test Receiver Setup
The system was investigated from 9 kHz to 1 GHz.

During the radiated emission test, the EMI test Receiver was set with the following configurations:

                       Frequency Range              RBW          Video B/W       Measurement
                        9 kHz – 150 kHz            200 Hz           1 kHz         QP/Average
                       150 kHz – 30 MHz             9 kHz           30 kHz        QP/Average
                      30 MHz – 1000 MHz            120 kHz         300 kHz            QP

The emission limits shown in the above table are based on measurements employing a CISPR quasi-peak
detector except for the frequency bands 9-90 kHz, 110-490 kHz and above 1000 MHz. Radiated emission
limits in these three bands are based on measurements employing an average detector.

If the maximized peak measured value complies with the limit, then it is unnecessary to perform an
QP/Average measurement


Corrected Amplitude & Margin Calculation
The Corrected Amplitude is calculated by adding the Antenna Factor and Cable Loss, and subtracting the
Amplifier Gain from the Amplitude reading. The basic equation is as follows:

                  Corr. Ampl. = Meter Reading + Antenna Factor + Cable Loss - Amplifier Gain

The “Margin” column of the following data tables indicates the degree of compliance with the applicable
limit. For example, a margin of 7dB means the emission is 7dB below the limit. The equation for margin
calculation is as follows:

                                           Margin = Limit - Corr. Ampl.

Test Equipment List and Details

                                                                     Serial       Calibration     Calibration
     Manufacturer             Description             Model
                                                                    Number           Date          Due Date

   Sonoma instrument           Amplifier              310 N          186238        2018-11-12      2019-05-12

   Rohde & Schwarz         EMI Test Receiver          ESCI           101120        2018-01-11      2019-01-11
     Sunol Sciences        Broadband Antenna           JB1         A040904-1       2017-12-22      2020-12-21
          ETS            Passive Loop Antenna         6512           29604         2018-03-07      2021-03-06
          TDK                   Chamber            Chamber A              2#       2016-12-05      2019-12-05
      UTiFLEX                                       UFA147A-       MFR64639
                                RF Cable                                           2018-08-01      2019-02-01
     MICRO-C0AX                                    2362-100100     231029-003
       Ducommun
                                RF Cable             104PEA        218124002       2018-05-21      2018-11-21
      technologies

    * Statement of Traceability: Bay Area Compliance Laboratories Corp. (Shenzhen) attests that all calibrations
     have been performed, traceable to National Primary Standards and International System of Units (SI).
FCC Part 15C                                                                                        Page 18 of 21


Bay Area Compliance Laboratories Corp. (Shenzhen)                            Report No.: RSZ181029830-00

Test Results Summary
According to the data in the following table, the EUT complied with the FCC Part 15.209&15.205.


Test Data
     Environmental Conditions

            Temperature:               26 oC
       Relative Humidity:               57 %
           ATM Pressure:             100.7 kPa

     The testing was performed by Hill He on 2018-11-16.

    Test mode: Transmitting


1) 9 kHz~30MHz:

                                                                                  FCC Part
Frequency Corrected            Turntable Rx Antenna            Corrected
                      Detector                                                 15.205&15.209
          Amplitude                                             Factor                            Remark
                    (PK/QP/AV)          Height                               Limit     Margin
  (MHz) (dBμV/m)                Degree         Polar             (dB/m)
                                         (m)                               (dBμV/m)     (dB)
 0.010692   48.95       PK       175      1      H               87.3        127.02     78.07     Spurious
  0.5082       65.91        PK        203        1         H     65.7        73.48     7.57       emission

   0.150       85.27        PK        227        1         H     63.5       104.08     18.81    Fundamental




FCC Part 15C                                                                                    Page 19 of 21


Bay Area Compliance Laboratories Corp. (Shenzhen)                                                  Report No.: RSZ181029830-00

                                                             9 KHz-150 KHz
                                                                   * RBW 300 Hz   Marker 1 [T1 ]
                                                                    VBW 1 kHz               48.95 dBµV
                         Ref       129 dBµV       * Att   40 dB     SWT 1.6 s         10.692000000 kHz


                             9K-150K
                             120                                                                          A

                  1 PK
                  MAXH       110


                                                                                                         TDF
                             100


                                                                                                         PS
                             90



                             80


                                                                                                         3DB
                             70                                                                          AC



                             60


                         1
                             50



                             40


                             30

                         Start 9 kHz                          14.1 kHz/                   Stop 150 kHz




                  EUT
                  Date: 16.NOV.2018           13:46:02




                                                            150 KHz-30MHz
                                                                   * RBW 10 kHz   Marker 2 [T1 ]
                                                                    VBW 30 kHz              65.91 dBµV
                         Ref       102 dBµV       * Att   20 dB     SWT 300 ms       508.200000000 kHz
                             100                                                  Marker 1 [T1 ]
                             150K-30M                                                       85.27 dBµV
                                                                                     150.000000000 kHz    A
                             90
                         1
                  1 PK
                  MAXH
                             80

     Fundamental                                                                                         TDF
                         70
                         2
                                                                                                         PS

                             60



                             50
                                                                                                         3DB
                                                                                                         AC
                             40



                             30



                             20



                             10



                         Start 150 kHz                       2.985 MHz/                    Stop 30 MHz




                  EUT
                  Date: 16.NOV.2018           13:51:47




FCC Part 15C                                                                                                        Page 20 of 21


Bay Area Compliance Laboratories Corp. (Shenzhen)                                                   Report No.: RSZ181029830-00

2) 30 MHz ~ 1GHz



                          80



                          70



                          60



                          50                                                                  Electric Field Strength QP-3m
         Level in dBμV/




                          40



                          30



                          20



                          10



                           0
                           30M         50    60      80   100M                200      300      400    500           800       1G
                                                                     Frequency in Hz




                                 Corrected    Antenna                     Turntable    Correction
     Frequency                                              Antenna                                         Limit             Margin
                                 Amplitude     height                      position     Factor
       (MHz)                                                Polarity                                      (dBμV/m)             (dB)
                                 (dBμV/m)       (cm)                       (degree)     (dB/m)

     32.916625                     17.19          113.0          V           270.0           -9.4            40.00             22.81
     40.811375                     19.22          123.0          V           282.0           -14.3           40.00             20.78
     48.092750                     24.68          100.0          V           259.0           -18.8           40.00             15.32
     52.326500                     20.47          100.0          V           245.0           -19.8           40.00             19.53
     828.899500                    38.92          383.0          H           215.0            4.8            46.00             7.08
     925.450750                    30.96          130.0          V            64.0            7.1            46.00             15.04

Note:
Corrected Amplitude = Corrected Factor + Reading
Corrected Factor=Antenna factor (RX) + cable loss - amplifier factor
Margin = Limit- Corr. Amplitude

Result: Compliance

                                                  ***** END OF REPORT *****
FCC Part 15C                                                                                                                  Page 21 of 21



Document Created: 2019-09-06 23:08:06
Document Modified: 2019-09-06 23:08:06

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC