User Manual

FCC ID: 2AHKM-CSN01

Users Manual

Download: PDF
FCCID_4093917

                                                                                                    CSN-01


     Signal Generator
     24MHz-1.7GHz F connector with Wi-Fi 802.11n features
     Battery included
     Manual mode for simple setting
     APP for Smartphone/Pad usage




     KEY FEATURES

     • Output frequency range 24MHz~1.7GHz                   • Wi-Fi 11b/g/n with internal antennas
     • Stepping : 1MHz                                          • 2T2R 2.4GHz with 150Mbps PHY rate
     • Output power : 40dBmv, 60dBmv                            • Frequency range : 2412~2462MHz
        Tolerance: +/-3dBmv                                  • Includes a 5V battery
     • Power: USB2.0 (+5V/2A)                                • Simple buttons setting for Hi/Lo frequency/power
     • Interface : USB2.0, F-type male 75Ω connector         • LEDs indicator for Signal output




     APP by Wi-Fi CONNECTION

     The APP designed for smartphone for related parameter setting by WiFi connection.
      - Android platform
     - Same as CGN-DP3



     Item Include

     1.   24MHz~1.7GHz signal generator x 1
     2.   USB type A to type A cable
     3.   5V/2A USB adapter




     Hitron HQ - www.hitrontech.com            USA - www.hitron-americas.com             Europe - www.hitron-europe.com
No. 1-8, Lihsin 1st Rd, Hsinchu Science Park          9000 E Nichols Ave                    Kingsfordweg 151 1043 GR
              Hsinchu, Taiwan                   Centennial CO 80112 Suite 103              Amsterdam, The Netherlands
            Tel: +886 3 5786658                      Tel: +1 303 792 3380                      Tel: +31 20 491 9995


SPECIFICATIONS


  Connectivity                                                         Environmental
  * 1 x RF F—type male 750 connector                                   * Operating temperature: 0°C (32°F) — 40°C (104°F)
  * 1 x female to female adapter                                       * Operating humidity: 10% — 90% (non—condensing)
  * 1 x Rl—45 Ethernet port 10/100 Mbps (Auto—                         * Storage temperature: —40°C (—40°F) — 80°C (176°F)
   MDI/MDIX)
  * 1x USB2.0 connector
  * 1 x Factory reset button                                           Compliance Certificates
  * 1 x Force power off button                                         * FCC, UL
                                                                       * RoHS compliant
                                                                       * IP20
  Management
  * App—based GUI for configuration and management

  Wireless
  * 802.11 b/g/n
  * 2T2R 2.4GHz (2412MHz—2462MHz) 802.11n with
    150Mbps PHY data rate
  * 20/40MHz channel bandwidth
  * Wi—Fi output power Range :
    *2.4G (.11n)        13dBm
    *2.4G (.11g)        15dBm
    *2.4G (.11b)        17dBm

  Mechanical
  * 9 Status LEDs
  * 4 Buttons
  * Dimensions: 220.3mm (L) x 32mm (W) x 42mm (H)
  * Weight: 4008 + 108

  Electrical
  * USB Power input: 5V / 2A
  * Power consumption: 5 W (typical), 6W (max.)
  * Battery with lithium battery cells
  * Surge protection:   RF input sustains at least 4KV,
                        Ethernet RJ—45 sustains at least 4KV




mm
                                                 CSN—01_2017_1A— Issued Oct. 2017
                                    Specifications subject to change without further notice
                Trademarks owned by Hitron Technologies Inc. 2016 © Hitron Technologies Inc. — All rights reserved


      Federal Communication Commission Interference
                       Statement
•
                                                                 •         Industry Canada statement:
• This device complies with Part 15 of the FCC Rules.
  Operation is subject to the following two conditions: (1)
  This device may not cause harmful interference, and (2)        •   This device complies with ISED’s licence-exempt RSSs.
  this device must accept any interference received,
  including interference that may cause undesired                    Operation is subject to the following two conditions: (1) This
  operation.                                                         device may not cause harmful interference, and (2) this device
•                                                                    must accept any interference received, including interference
                                                                     that may cause undesired operation.
• This equipment has been tested and found to comply             •   Le présent appareil est conforme aux CNR d’ ISED applicables
  with the limits for a Class B digital device, pursuant to
  Part 15 of the FCC Rules. These limits are designed to             aux appareils radio exempts de licence. L’exploitation est
  provide reasonable protection against harmful                      autorisée aux deux conditions suivantes : (1) le dispositif ne doit
  interference in a residential installation. This equipment         pas produire de brouillage préjudiciable, et (2) ce dispositif doit
  generates, uses and can radiate radio frequency energy
  and, if not installed and used in accordance with the              accepter tout brouillage reçu, y compris un brouillage
  instructions, may cause harmful interference to radio              susceptible de provoquer un fonctionnement indésirable.
  communications. However, there is no guarantee that
  interference will not occur in a particular installation. If   •   Caution :
  this equipment does cause harmful interference to radio        •   (iii) where applicable, antenna type(s), antenna models(s), and
  or television reception, which can be determined by
  turning the equipment off and on, the user is                      worst-case tilt angle(s) necessary to remain compliant with the
  encouraged to try to correct the interference by one of            e.i.r.p. elevation mask requirement set forth in section 6.2.2.3
  the following measures:                                            shall be clearly indicated.
•                                                                •   Avertissement:
                                                                 •   (iii) lorsqu’il y a lieu, les types d’antennes (s’il y en a plusieurs),
• - Reorient or relocate the receiving antenna.
                                                                     les numéros de modèle de l’antenne et les pires angles
• - Increase the separation between the equipment and                d’inclinaison nécessaires pour rester conforme à l’exigence de
  receiver.                                                          la p.i.r.e. applicable au masque d’élévation, énoncée à la
• - Connect the equipment into an outlet on a circuit                section 6.2.2.3, doivent être clairement indiqués.
  different from that to which the receiver is connected.
• - Consult the dealer or an experienced radio/TV                •          Radiation Exposure Statement:
  technician for help.                                           •          This equipment complies with ISED radiation exposure
• FCC Caution: Any changes or modifications not expressly        limits set forth for an uncontrolled environment. This equipment
  approved by the party responsible for compliance could         should be installed and operated with greater than 20 cm between
  void the user's authority to operate this equipment.           the radiator & your body.
• This transmitter must not be co-located or operating in        •          Déclaration d'exposition aux radiations:
  conjunction with any other antenna or transmitter.             Cet équipement est conforme aux limites d'exposition aux
•                                                                rayonnements ISED établies pour un environnement non contrôlé.
    Radiation Exposure Statement:                                Cet équipement doit être installé et utilisé à plus de 30 cm entre le
                                                                 radiateur et votre corps.
• This equipment complies with FCC radiation exposure
  limits set forth for an uncontrolled environment. This
  equipment should be installed and operated with
  minimum distance 20 cm between the radiator & your
  body.




                                Specifications subject to change without further notice
            Trademarks owned by Hitron Technologies Inc. 2016 © Hitron Technologies Inc. – All rights reserved



Document Created: 2018-11-29 17:45:04
Document Modified: 2018-11-29 17:45:04

© 2024 FCC.report