RF Test Report-15B

FCC ID: 2AHJX-ALPHA2

Test Report

Download: PDF
FCCID_3047400

                FCC Test Report
        FCC ID: 2AHJX-ALPHA2

                Product: Alpha Intelligent Robot 2
            Trade Name: UBTECH
          Model Number: Alpha 2
            Serial Model: N/A
              Report No.: NTEK- 2016NT06166548F1




                           Prepared for

                     UBTECH ROBOTICS CORP
16th & 22nd Floor, Block C1, Nanshan I Park, No.1001 Xueyuan Road,
           Nanshan District, Shenzhen City, PR. CHINA


                           Prepared by

            Shenzhen NTEK Testing Technology Co., Ltd.
1/F, Building E, Fenda Science Park, Sanwei Community, Xixiang Street,
                   Bao’an District, Shenzhen P.R. China
           Tel.: +86-0755-61156588 Fax.: +86-0755-61156599
                        Website: www.ntek.org.cn


                                                            Page 2 of 23        Report No.: NTEK- 2016NT06166548F1



                                         TEST RESULT CERTIFICATION

Applicant’s name ................. : UBTECH ROBOTICS CORP
                                                 16th & 22nd Floor, Block C1, Nanshan I Park, No.1001 Xueyuan
Address ................................. :
                                                 Road, Nanshan District, Shenzhen City, PR. CHINA
Manufacturer's Name .......... : UBTECH ROBOTICS CORP BAOAN BRANCH
                                                 5/F,Building C,Huilongda Industry Park,Shilongzai,Shiyan
Address ................................. :
                                                 Street,Baoan District,Shenzhen City.
Product description
Product name ........................... : Alpha Intelligent Robot 2
Model and/or type reference : Alpha 2
                                          FCC Part15B:01 Oct.2015
Standards ............................. :
                                          ANSI C63.4:2014
This device described above has been tested by NTEK, and the test results show that the
equipment under test (EUT) is in compliance with Part 15 of FCC Rules. And it is applicable only to
the tested sample identified in the report.
This report shall not be reproduced except in full, without the written approval of NTEK, this
document may be altered or revised by NTEK, personnel only, and shall be noted in the revision of
the document.
Date of Test ............................................ :
Date (s) of performance of tests ............. :                16 Jun. 2016 ~18 Jun. 2016
Date of Issue ........................................... :     18 Jun. 2016
Test Result ............................................... :   Pass



                          Testing Engineer                  :

                                                                           (Eileen Liu)


                          Technical Manager                 :

                                                                           (Jason Chen)


                          Authorized Signatory :

                                                                           (Sam Chen)


                              Page 3 of 23   Report No.: NTEK- 2016NT06166548F1




                        Table of Contents                          Page


1 . TEST SUMMARY                                                          4
  1.1 TEST FACILITY                                                       5
  1.2 MEASUREMENT UNCERTAINTY                                             5
2 . GENERAL INFORMATION                                                   6
  2.1 GENERAL DESCRIPTION OF EUT                                          6
  2.2 DESCRIPTION OF TEST SETUP                                           8
  2.3 DESCRIPTION TEST PERIPHERAL AND EUT PERIPHERAL                      9
  2.4 MEASUREMENT INSTRUMENTS LIST                                     10
3 . EMC EMISSION TEST                                                  11
  3.1 CONDUCTED EMISSION MEASUREMENT                                   11
     3.1.1 POWER LINE CONDUCTED EMISSION                               11
     3.1.2 TEST PROCEDURE                                              12
     3.1.3 TEST SETUP                                                  12
     3.1.4 EUT OPERATING CONDITIONS                                    12
     3.1.5 TEST RESULTS                                                13
  3.2 RADIATED EMISSION MEASUREMENT                                    17
     3.2.1 LIMITS OF RADIATED EMISSION MEASUREMENT                     17
     3.2.2 TEST PROCEDURE                                              17
     3.2.3 TEST SETUP                                                  18
     3.2.4 TEST RESULTS                                                19
     3.2.5 TEST RESULTS(1000~12400MHz)                                 21
4 . EUT TEST PHOTO                                                     22


                                        Page 4 of 23         Report No.: NTEK- 2016NT06166548F1

1. TEST SUMMARY

Test procedures according to the technical standards:
                                         EMC Emission

          Standard                      Test Item               Limit       Judgment   Remark

                                  Conducted Emission           Class B        PASS
     FCC Part15B:2014
     ANSI C63.4: 2014
                                   Radiated Emission           Class B        PASS
NOTE:
    (1) ’N/A’ denotes test is not applicable in this Test Report
    (2) For client’s request and manual description, the test will not be executed.


                                       Page 5 of 23         Report No.: NTEK- 2016NT06166548F1


1.1 TEST FACILITY
   NTEK Testing Technology Co., Ltd
   Add. : 1/F, Building E, Fenda Science Park, Sanwei Community, Xixiang Street, Bao’an District,
  Shenzhen P.R. China.
   FCC Registration Number:238937; IC Registration Number:9270A-1
   CNAS Registration Number:L5516
1.2 MEASUREMENT UNCERTAINTY
  The reported uncertainty of measurement y ± U, where expended uncertainty U is based on a
  standard uncertainty multiplied by a coverage factor of k=2, providing a level of confidence of
  approximately 95 %.

  A. Conducted Measurement :

     Test Site Method        Measurement Frequency Range          U,(dB)         NOTE
     NTEKC01 ANSI                 150 KHz ~ 30MHz                  3.2

  B. Radiated Measurement :

     Test Site Method        Measurement Frequency Range          U,(dB)         NOTE
     NTEKA01 ANSI                 30MHz ~ 1000MHz                  4.7
                                   1GHz ~12.4GHz                   5.0


                                        Page 6 of 23        Report No.: NTEK- 2016NT06166548F1

2. GENERAL INFORMATION

2.1 GENERAL DESCRIPTION OF EUT

 Equipment             Alpha Intelligent Robot 2
 Trade Name            UBTECH
 Model Name            Alpha 2
 Serial Model          N/A
 Model Difference      N/A

                        The EUT is a Alpha Intelligent Robot 2.

                        Connecting I/O port:       USB, DC in
                        Operation Frequency:       BT:2402~2480 MHz
                                                   WIFI:802.11b/g/n(20MHz): 2412~2462MHz
 Product Description    Modulation Type:           BT(1Mbps): GFSK
                                                   BT EDR(2Mbps): π/4-DQPSK
                                                   BT EDR(3Mbps): 8-DPSK
                                                   IEEE 802.11b :
                                                   DSSS (CCK, QPSK, DBPSK)
                                                   IEEE 802.11g/n (HT20) : OFDM


 Power Source          DC Voltage
                       Model:WT1403000
 Adapter               Input: AC100-240V~, 50/60Hz,1.6A
                       Output: 14V , 3.0A
 Battery               DC 11.1V, 2150mAh


                                            Page 7 of 23          Report No.: NTEK- 2016NT06166548F1

2.1.1 DESCRIPTION OF TEST MODES

    To investigate the maximum EMI emission characteristics generates from EUT, the test
    system was pre-scanning tested base on the consideration of following EUT operation
    mode or test configuration mode which possible have effect on EMI emission level.
    Each of these EUT operation mode(s) or test configuration mode(s) mentioned above
    was evaluated respectively.

              Pretest Mode                                 Description
                 Mode 1                                   Connect to PC


                                       For Conducted Test
             Final Test Mode                               Description
                  Mode 1                                  Connect to PC


                                         For Radiated Test
             Final Test Mode                               Description
                 Mode 1                                   Connect to PC
    Note: Final Test Mode: Through Pre-scan, find the mode 1 is the worst case.
    Only the worst case mode is recorded in the report.


                                               Page 8 of 23           Report No.: NTEK- 2016NT06166548F1

2.2 DESCRIPTION OF TEST SETUP

RE
                             AC Source
                                     C-6                      C-2
               C-3
                                                  C-1

        E-2                   E-3                 E-1                  E-4
       Printer                PC                  EUT                 Monitor


0.8m                 C-4
                                           C-5

                       E-5               E-6
                       KB               Mouse

       Table

                                        1.5m



                               C-3
CE

                                         C-2
                                                    C-1

         E-2                   E-4                   E-1                   E-3       C-6
        Printer               Monitor                EUT                   PC                  LISN


0.8m
                                                                    C-4            C-5

                                                                    E-5           E-6
                                                                    KB           Mouse

       Table

                                        1.5m


                                         Page 9 of 23        Report No.: NTEK- 2016NT06166548F1

2.3 DESCRIPTION TEST PERIPHERAL AND EUT PERIPHERAL

The EUT has been tested as an independent unit together with other necessary accessories or
support units. The following support units or accessories were used to form a representative test
configuration during the tests.

Item        Equipment           Brand      Model/Type No.          Series No.              Note
         Alpha Intelligent
 E-1                          UBTECH           Alpha 2                 N/A                 EUT
             Robot 2
 E-2         Printer           Canon          L11121E              LBP2900
 E-3 Personal computer          DELL          FT4Y23X             34413561645
                                                            cn-0y6mhx-74261-11f-67e
 E-4         Monitor            DELL         IN2020MB
                                                                       s
 E-5        Keyboard            DELL          SK-8185              OY526KUS
 E-6         Mouse              DELL          MS111-P       cn-011d3v-71581-11e-1th7




 Item     Cable Type     Shielded Type   Ferrite Core         Length                Note
 C-1      USB Cable          NO              NO                1.2m
 C-2         VGA             NO              NO                1.0m
 C-3      USB Cable          NO              NO                1.2m
 C-4      USB Cable          NO              NO                1.0m
 C-5      USB Cable          NO              NO                1.0m
 C-6      Power Line         NO              NO                1.2m




 Note:
  (1)     The support equipment was authorized by Declaration of Confirmation.
  (2)     For detachable type I/O cable should be specified the length in cm in『Length』column.
  (3)     “YES” means “shielded” “with core”; “NO” means “unshielded” “without core”.


                                        Page 10 of 23          Report No.: NTEK- 2016NT06166548F1

2.4 MEASUREMENT INSTRUMENTS LIST

Radiation Test equipment
Item     Kind of    Manufacturer      Type No.    Serial No.      Last       Calibrated Calibratio
       Equipment                                               calibration     until    n period
  1    Spectrum                                   MY4510804
                      Agilent         E4407B                2015.07.06 2016.07.05         1 year
        Analyzer                                      0
  2 Test Receiver      R&S             ESPI        101318   2016.06.07 2017.06.06         1 year
 3     Bilog Antenna   TESEQ   CBL6111D     31216   2015.07.06 2016.07.05                 1 year
        50Ω Coaxial                      620026441
 4                     Anritsu  MP59B               2016.06.07 2017.06.06                 1 year
           Switch                             6
         Spectrum
 5                   ADVANTEST   R3132   150900201 2016.06.07 2017.06.06                  1 year
          Analyzer
                               EM-AH-101
 6     Horn Antenna      EM              2011071402 2015.07.06 2016.07.05                 1 year
                                  80
 7        Horn Ant Schwarzbeck BBHA 9170 9170-181 2015.07.06 2016.07.05                   1 year
 8       Amplifier        EM         EM-30180      060538      2015.07.06 2016.07.05      1 year
 9     Loop Antenna       ARA        PLA-1030/B     1029       2016.06.07 2017.06.06      1 year
 10    Power Meter        R&S          NRVS         100696   2015.07.06 2016.07.05        1 year
          Power                                   0395.1619.
 11                       R&S         URV5-Z4                2015.07.06 2016.07.05        1 year
          Sensor                                      05
 12     Test Cable        N/A          R-01          N/A     2015.07.06 2016.07.05        1 year
 13     Test Cable        N/A          R-02          N/A       2015.07.06 2016.07.05      1 year

Conduction Test equipment

Item      Kind of        Manufactu    Type No.    Serial No.      Last    Calibrated Calibratio
         Equipment          rer                                calibration   until   n period
 1      Test Receiver      R&S         ESCI        101160      2016.06.06 2017.06.05 1 year
 2          LISN           R&S        ENV216       101313      2015.08.24 2016.08.23      1 year
 3          LISN          EMCO         3816/2     00042990 2015.08.24 2016.08.23          1 year
         50Ω Coaxial                              620026441
 4                        Anritsu     MP59B                 2016.06.07 2017.06.06         1 year
           Switch                                     7
 5     Passive Voltage
                           R&S        ESH2-Z3      100196      2016.06.07 2017.06.06      1 year
           Probe
 6     Absorbing clamp     R&S        MOS-21       100423      2016.06.08 2017.06.07      1 year
 7       Test Cable        N/A          C01          N/A       2016.06.08 2017.06.07      1 year
 8       Test Cable        N/A          C02          N/A       2016.06.08 2017.06.07      1 year
 9       Test Cable        N/A          C03          N/A       2016.06.08 2017.06.07      1 year


                                          Page 11 of 23      Report No.: NTEK- 2016NT06166548F1


3. EMC EMISSION TEST

3.1 CONDUCTED EMISSION MEASUREMENT

3.1.1 POWER LINE CONDUCTED EMISSION (Frequency Range 150KHz-30MHz)

                                    Class A (dBuV)                   Class B (dBuV)
   FREQUENCY (MHz)
                               Quasi-peak       Average      Quasi-peak         Average
         0.15 -0.5                79.00              66.00    66 - 56 *         56 - 46 *
         0.50 -5.0                73.00              60.00     56.00             46.00
        5.0 -30.0                73.00           60.00     60.00              50.00
       Note:
         (1) The tighter limit applies at the band edges.
         (2) The limit of " * " marked band means the limitation decreases linearly with the
             logarithm of the frequency in the range.



The following table is the setting of the receiver
               Receiver Parameters                                  Setting
                    Attenuation                                      10 dB
                 Start Frequency                                   0.15 MHz
                 Stop Frequency                                     30 MHz
                   IF Bandwidth                                      9 kHz


                                        Page 12 of 23          Report No.: NTEK- 2016NT06166548F1

3.1.2 TEST PROCEDURE
 a. The EUT was placed 0.8 meters from the horizontal ground plane with EUT being connected
    to the power mains through a line impedance stabilization network (LISN). All other support
    equipments powered from additional LISN(s). The LISN provide 50 Ohm/ 50uH of coupling
    impedance for the measuring instrument.
 b. Interconnecting cables that hang closer than 40 cm to the ground plane shall be folded back
    and forth in the center forming a bundle 30 to 40 cm long.
 c. I/O cables that are not connected to a peripheral shall be bundled in the center. The end of the
    cable may be terminated, if required, using the correct terminating impedance. The overall
    length shall not exceed 1 m.
 d. LISN at least 80 cm from nearest part of EUT chassis.
 e. For the actual test configuration, please refer to the related Item –EUT Test Photos.


3.1.3 TEST SETUP




3.1.4 EUT OPERATING CONDITIONS
The EUT tested system was configured as the statements of 2.3 Unless otherwise a special
operating condition is specified in the follows during the testing.


                                              Page 13 of 23      Report No.: NTEK- 2016NT06166548F1

3.1.5 TEST RESULTS


EUT:                 Alpha Intelligent Robot 2 Model Name. :             Alpha 2
Temperature:         26 ℃                      Relative Humidity:        54%
Pressure:            1010hPa                   Test Date:                2016-6-17
Test Mode:           Mode 1                    Phase :                   L
Test Voltage:        DC 5V From PC AC 120V/60Hz

  Frequency      Reading Level Correct Factor    Measure-ment   Limits      Margin
                                                                                         Remark
    (MHz)            (dBμV)            (dB)          (dBμV)     (dBμV)       (dB)

    0.2020           32.86            10.13          42.99      63.52       -20.53        QP

    0.2020           29.69            10.13          39.82      53.52       -13.70        AVG

    0.8020           27.00             9.80          36.80      56.00       -19.20        QP

    0.8020           24.01             9.80          33.81      46.00       -12.19        AVG

    1.1019           26.17             9.84          36.01      56.00       -19.99        QP

    1.1019           22.72             9.84          32.56      46.00       -13.44        AVG

    1.8020           26.11             9.75          35.86      56.00       -20.14        QP

    1.8020           22.17             9.75          31.92      46.00       -14.08        AVG

    15.4177          29.47             9.87          39.34      60.00       -20.66        QP

    15.4177          17.87             9.87          27.74      50.00       -22.26        AVG

    24.6418          34.70             9.98          44.68      60.00       -15.32        QP

    24.6418          21.58             9.98          31.56      50.00       -18.44        AVG
Remark:
1. All readings are Quasi-Peak and Average values.
2. Factor = Insertion Loss + Cable Loss.


                                              Page 14 of 23      Report No.: NTEK- 2016NT06166548F1



EUT:                 Alpha Intelligent Robot 2 Model Name. :             Alpha 2
Temperature:         26 ℃                      Relative Humidity:        54%
Pressure:            1010hPa                   Test Date:                2016-6-17
Test Mode:           Mode 1                    Phase :                   N
Test Voltage:        DC 5V From PC AC 120V/60Hz

  Frequency      Reading Level Correct Factor    Measure-ment   Limits      Margin
                                                                                         Remark
    (MHz)            (dBμV)            (dB)          (dBμV)     (dBμV)       (dB)

    0.1980           31.88            10.02          41.90      63.69       -21.79        QP

    0.1980           25.90            10.02          35.92      53.69       -17.77        AVG

    0.5020           27.00             9.82          36.82      56.00       -19.18        QP

    0.5020           23.14             9.82          32.96      46.00       -13.04        AVG

    0.8020           27.21             9.83          37.04      56.00       -18.96        QP

    0.8020           24.06             9.83          33.89      46.00       -12.11        AVG

    1.5020           26.43             9.81          36.24      56.00       -19.76        QP

    1.5020           23.15             9.81          32.96      46.00       -13.04        AVG

    16.0059          39.13             9.82          48.95      60.00       -11.05        QP

    16.0059          26.36             9.82          36.18      50.00       -13.82        AVG

    24.7139          34.13             9.97          44.10      60.00       -15.90        QP

    24.7139          21.37             9.97          31.34      50.00       -18.66        AVG
Remark:
1. All readings are Quasi-Peak and Average values.
2. Factor = Insertion Loss + Cable Loss.


                                              Page 15 of 23      Report No.: NTEK- 2016NT06166548F1

EUT:                 Alpha Intelligent Robot 2 Model Name. :             Alpha 2
Temperature:         26 ℃                      Relative Humidity:        54%
Pressure:            1010hPa                   Test Date:                2016-6-17
Test Mode:           Mode 1                    Phase :                   L
Test Voltage:        DC 5V From PC AC 240V/60Hz

  Frequency      Reading Level Correct Factor    Measure-ment   Limits      Margin
                                                                                         Remark
    (MHz)            (dBμV)            (dB)          (dBμV)     (dBμV)       (dB)

    0.2020           42.86            10.13          52.99      63.52       -10.53        QP

    0.2020           39.69            10.13          49.82      53.52        -3.70        AVG

    0.3019           36.20            10.14          46.34      60.19       -13.85        QP

    0.3019           29.32            10.14          39.46      50.19       -10.73        AVG

    0.8020           35.50             9.80          45.30      56.00       -10.70        QP

    0.8020           32.51             9.80          42.31      46.00        -3.69        AVG

    1.1019           33.17             9.84          43.01      56.00       -12.99        QP

    1.1019           29.72             9.84          39.56      46.00        -6.44        AVG

    4.4099           33.21             9.75          42.96      56.00       -13.04        QP

    4.4099           28.25             9.75          38.00      46.00        -8.00        AVG

    15.0175          34.99             9.86          44.85      60.00       -15.15        QP

    15.0175          23.58             9.86          33.44      50.00       -16.56        AVG
Remark:
1. All readings are Quasi-Peak and Average values.
2. Factor = Insertion Loss + Cable Loss.


                                              Page 16 of 23      Report No.: NTEK- 2016NT06166548F1

EUT:                 Alpha Intelligent Robot 2 Model Name. :             Alpha 2
Temperature:         26 ℃                      Relative Humidity:        54%
Pressure:            1010hPa                   Test Date:                2016-6-17
Test Mode:           Mode 1                    Phase :                   N
Test Voltage:        DC 5V From PC AC 240V/60Hz

  Frequency      Reading Level Correct Factor    Measure-ment   Limits      Margin
                                                                                         Remark
    (MHz)            (dBμV)            (dB)          (dBμV)     (dBμV)       (dB)

    0.1985           37.38            10.02          47.40      63.67       -16.27        QP

    0.1985           31.25            10.02          41.27      53.67       -12.40        AVG

    0.4020           33.34            10.05          43.39      57.81       -14.42        QP

    0.4020           28.89            10.05          38.94      47.81        -8.87        AVG

    0.8020           32.71             9.83          42.54      56.00       -13.46        QP

    0.8020           29.56             9.83          39.39      46.00        -6.61        AVG

    1.2016           32.69             9.85          42.54      56.00       -13.46        QP

    1.2016           30.39             9.85          40.24      46.00        -5.76        AVG

    1.8020           34.28             9.77          44.05      56.00       -11.95        QP

    1.8020           29.83             9.77          39.60      46.00        -6.40        AVG

    16.0059          35.13             9.82          44.95      60.00       -15.05        QP

    16.0059          22.36             9.82          32.18      50.00       -17.82        AVG
Remark:
1. All readings are Quasi-Peak and Average values.
2. Factor = Insertion Loss + Cable Loss.


                                       Page 17 of 23         Report No.: NTEK- 2016NT06166548F1

3.2 RADIATED EMISSION MEASUREMENT

3.2.1 LIMITS OF RADIATED EMISSION MEASUREMENT

                                   Class A (at 10m)                    Class B (at 3m)
  FREQUENCY (MHz)
                                       dBuV/m                             dBuV/m
        30 ~ 88                          39.0                               40.0
        88 ~ 216                         43.5                               43.5
       216 ~ 960                         46.5                               46.0
       Above 960                         49.5                               54.0

     Notes:
        (1) The limit for radiated test was performed according to as following:
            FCC PART 15B /ICES-003.
        (2) The tighter limit applies at the band edges.
        (3) Emission level (dBuV/m)=20log Emission level (uV/m).


3.2.2 TEST PROCEDURE
   Test Arrangement for Radiated Emissions up to 1 GHz
  a. The EUT was placed on the top of a rotating table 0.8 meters above the ground at an
      accredited test facility. The table was rotated 360 degrees to determine the position of the
      highest radiation.
  b. The EUT was set 3 meters away from the interference-receiving antenna, which was mounted
      on the top of a variable-height antenna tower.
  c. The antenna is a broadband antenna, and its height is varied from one meter to four meters
     above the ground to determine the maximum value of the field strength. Both horizontal and
     vertical polarizations of the antenna are set to make the measurement.
  d. For each suspected emission, the EUT was arranged to its worst case and then the antenna
     was tuned to heights from 1 meter to 4 meters and the rotatable table was turned from 0
     degrees to 360 degrees to find the maximum reading.

  Note: The resolution bandwidth and video bandwidth of test receiver/spectrum analyzer is 120kHz
   for quasi-peak detection (QP) at frequency below 1GHz.
   Test Arrangement for Radiated Emissions above 1 GHz.

  a. The EUT was placed on the top of a rotating table 0.8 meters above the ground at an
     accredited chamber room. The table was rotated 360 degrees to determine the position of the
     highest radiation.
  b. The EUT was set 3 meters away from the interference-receiving antenna, which was mounted
     on the top of a variable-height antenna tower.
  c. The height of antenna can be varied from one meter to four meters, the height of adjustment
     depends on the EUT height and the antenna 3dB beamwidth both, to detect the maximum
     value of the field strength.Both horizontal and vertical polarizations of the antenna are set to
     make the measurement.
  d. For each suspected emission, the EUT was arranged to its worst case and then the antenna
     was tuned to heights and the rotatable table was turned from 0 degrees to 360 degrees to find
     the maximum reading.

  Note:For the hand-held device, the EUT should be measured for all 3 axes and only the worst
   case is recorded in the report


                                          Page 18 of 23             Report No.: NTEK- 2016NT06166548F1

During the radiated emission test, the Spectrum Analyzer was set with the following configurations:

      Frequency Band
                               Function          Resolution bandwidth         Video Bandwidth
           (MHz)
         30 to 1000               QP                      120 kHz                 300 kHz

                                 Peak                     1 MHz                    1 MHz
        Above 1000
                                 Avg                      1 MHz                    10 Hz

 3.2.3 TEST SETUP
 For Radiated Emission 30~1000MHz




 (B) Radiated Emission Test Set-Up Frequency Above 1GHz


                                        Page 19 of 23          Report No.: NTEK- 2016NT06166548F1

 3.2.4 TEST RESULTS

TEST RESULTS (30~1000 MHz)
  EUT:          Alpha Intelligent Robot 2 Model Name:                  Alpha 2
  Temperature:  24 ℃                      Relative Humidity:           54%
  Pressure:     1010 hPa                  Test Date :                  2016-6-17
  Test Mode :   Mode 1                    Polarization :               Horizontal
  Test Power :  DC 5V From PC AC 120V/60Hz


                            Meter                   Emission
           Frequency                    Factor                     Limits      Margin
 Polar                     Reading                   Level
 (H/V)                                                                                   Remark
              (MHz)         (dBuV)       (dB)       (dBuV/m)     (dBuV/m)       (dB)
   H         94.0979        15.63       11.04        26.67         43.50       -16.83      QP
   H        194.4534        16.54       12.69        29.23         43.50       -14.27      QP
   H        269.4284        13.84       12.80        26.64         46.00       -19.36      QP
   H        299.3158        10.38       13.82        24.20         46.00       -21.80      QP
   H        599.3211        11.28       20.60        31.88         46.00       -14.12      QP
   H        776.8777        11.96       23.26        35.22         46.00       -10.78      QP


Remark:
Factor = Antenna Factor + Cable Loss - Amplifier.


                                        Page 20 of 23          Report No.: NTEK- 2016NT06166548F1

 EUT:                 Alpha Intelligent Robot 2 Model Name :           Alpha 2
 Temperature:         24 ℃                      Relative Humidity:     54%
 Pressure:            1010 hPa                  Test Date :            2016-6-17
 Test Mode :          Mode 1                    Polarization :         Vertical
 Test Power :         DC 5V From PC AC 120V/60Hz

                             Meter                  Emission
           Frequency                    Factor                     Limits     Margin
 Polar                      Reading                  Level
 (H/V)                                                                                   Remark
              (MHz)          (dBuV)      (dB)       (dBuV/m)     (dBuV/m)      (dB)
   V         37.5479         20.03      16.67        36.70         40.00       -3.30       QP
   V         92.4624         17.69      10.91        28.60         43.50      -14.90       QP
   V        163.1818         12.41      12.67        25.08         43.50      -18.42       QP
   V        205.6751         16.28      12.77        29.05         43.50      -14.45       QP
   V        299.3158          8.20      13.82        22.02         46.00      -23.98       QP
   V        504.7062          6.54      18.67        25.21         46.00      -20.79       QP

Remark:

Factor = Antenna Factor + Cable Loss - Amplifier.


                                       Page 21 of 23           Report No.: NTEK- 2016NT06166548F1


3.2.5 TEST RESULTS(1000~25000MHz)
The Testing have been conformed to 10*2462MHz=24620MHz, and the worst result was report as below:

                           Meter                    Emission
           Frequency                     Factor                    Limits     Margin
   Polar                  Reading                    Level
                                                                                        Remark
   (H/V)
             (MHz)         (dBuV)         (dB)      (dBuV/m)      (dBuV/m)     (dB)
    V     1107.528       60.80       -12.60      48.20         74.00          -25.80     peak
    V     1107.528       44.00       -12.60      31.40         54.00          -22.60     AVG
    V     2040.348       58.27        -7.67      50.60         74.00          -23.40     peak
    V     2040.348       43.07        -7.67      35.40         54.00          -18.60     AVG
    V     3442.900       55.73        -4.53      51.20         74.00          -22.80     peak
    V     3442.900       40.13        -4.53      35.60         54.00          -18.40     AVG
    V     4856.567       48.77        1.93       50.70         74.00          -23.30     peak
    V     4856.567       34.27        1.93       36.20         54.00          -17.80     AVG
    H     1191.952       58.07       -11.37      46.70         74.00          -27.30     peak
    H     1191.952       43.57       -11.37      32.20         54.00          -21.80     AVG
    H     1451.628       60.08       -10.58      49.50         74.00          -24.50     peak
    H     1451.628       44.38       -10.58      33.80         54.00          -20.20     AVG
    H     2247.628       59.36        -7.86      51.50         74.00          -22.50     peak
    H     2247.628       44.26        -7.86      36.40         54.00          -17.60     AVG
    H     2821.952       53.18        -6.28      46.90         74.00          -27.10     peak
  Remark:
  Absolute Level= ReadingLevel+ Factor, Margin= Absolute Level - Limit


                         Page 22 of 23     Report No.: NTEK- 2016NT06166548F1

4. EUT TEST PHOTO



                    Radiated Measurement Photos


      Page 23 of 23     Report No.: NTEK- 2016NT06166548F1

Conducted Measurement Photos